Workshop on Medical Device Cleanliness: How Clean is Clean Enough? Sponsored by ASTM Committee F04 on Medical and Surgical Materials and Devices

Similar documents
Water for Instrument Processing

HemoCheck TM Sample Policy. SUBJECT: Detection of blood residue on various surfaces

HemoCheck TM Sample Policy. SUBJECT: Detection of blood residue on various surfaces

Technical Data Monograph. The Instrument Protection Properties of Prolystica 2X Concentrate Neutral Detergent Versus Other Neutral Detergent Products

Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants

Guide for Cleaning, Sterilization and Storage of Reusable Introducers

3.03 Understand support services

How is Sterilization Validation Performed by the Medical Device Manufacturer?

The Power of Prolystica Cleaning Chemistries SO MUCH MORE THAN. One Integrated Approach to Healthcare.

Biofilms 101 Remediation Strategies in Meat Processing

Best Practices for Reprocessing Endoscopes

The Basics of Alkaline In-Process Cleaning. for Metal Substrates. John Sparks Oakite Products, Inc. Berkeley Heights, New Jersey

Enzyme Wizard Multi Enzyme cleaning formulations contain ingredients that are naturally occurring. They consist of four main ingredients natural

*Slides updated to include newer guidelines in February 2016 by Shelby Lassiter, BSN, RN, CPHQ, CIC

Professional instrument reprocessing in CSSD

DISCOVER INNOVATION DRIVING INCREASED EFFICIENCY

Monitoring Flexible Endoscope Channels to Assure Cleaning

One such problem is blood residual inside the channels of a robotic arm.

Lotus. Reprocessing instructions for reusable instrumentation

Lotus. Reprocessing instructions for reusable instrumentation. French/Swiss protocol

Manner of Assessment Code (check all that apply) & Surveyor Notes. Yes N/A. Yes. Yes N/A N/A. Yes N/A. N/A Yes N/A

SUBJECT: Detection of Blood residue inside the biopsy channel of a scope

3.03 Understand support services

Appendix 2. Revised 510(k) Summary

Validation of cleaning and sterilization of reusable medical devices

Sterilization, disinfection and reprocessing

Products made in Switzerland

Principles of Preservation

The Role of Detergents and Disinfectants in Instrument Cleaning and Reprocessing

MEMBRANE PRODUCTS PLEASE CONTACT YOUR LOCAL NORLEX CHEMICALS PARTNER FOR MORE INFORMATION ON THESE TYPES OF PRODUCTS.

Technical Data Monograph. Stainless Steel Instrument Maintenance Using Prolystica Restore Descaler & Neutralizing Detergent

6/12/2016. Objectives. Manufacturers Instructions for Use: Impact on Patient Safety. Background

Antiseptic and Disinfectant Product Group

Amalgatome SD Sterilization Tray User Guide

Getinge da Vinci Solution

What Does Validation Involve?

Sterilization of Schweickhardt Instruments

CAUTION: FEDERAL LAW (USA) RESTRICTS THESE DEVICES TO SALE BY OR ON THE ORDER OF A PHYSICIAN.

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes Webinar FAQ

HISTORY OF CHLORINE DIOXIDE

CDWA3 / CDWA4 CDWAH. Page 4. BASKET ZONE: water pressure, spray system performance, detergent chemistry and concentration, temperature.

Why wait until catastrophe strikes? Prevent the Chain Reaction of Equipment Wear, Maximize Heat Transfer, Protect Equipment Life

Cleaning and Sanitizing Products BRU-R-EZ CELL-R-MASTR DIACTOLATE. Features:

Applied Sanitation in Home. Rick Theiner LOGIC, Inc.

Guide to Optimal Steam Generation

Technical Data Monograph

THE EXPERTS IN INDUSTRIAL CLEANING

Recommendation

CLEANING IN THE AGE OF MAGNESIUM AND CALCIUM CHLORIDE

SUBJECT: Detection of Blood (hemoglobin) residue inside the biopsy channel of an endoendoscope

stain Benefits Premium Professional Clean

A Case Study from EP3: Pollution Prevention Assessment from a Cattle Hide Tannery. HBI Pub. 10/31/94

Human Alanine Aminotransferase (ALT) ELISA Kit. For Reference Only

Endoscope Decontamination. A Tube in a Hole??

Administrative Policies and Procedures. Cross Reference: Date Issued: 2/14 Date Reviewed: 9/14 Date: Revised: 12/14 Attachment: None Page of 1 of 6

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

Guidelines for Selection and Use of Disinfectants

protect public health protect the most sensitive among us protect the environment prevent the spread of antibiotic resistant bacteria

RBS detergents for laboratories

Loaner Program Guidance

INSTRUMENT CLEANING & STERILISATION FOAMING BATH FORMULATION. Surgistain. Rapid Multi-Enzyme Cleaner. Kimguard Sterile Wrap. Instrument brushes $32.

Daraclean Selection. Finding the right formulation MAGNAFLUX SOURCE

CLEANING AND HANDLING OF MICROPORT INSTRUMENTS The following languages are included in this packet:

Validation Strategy for an Automated Endoscope Reprocessor

Cleaning and Sanitizing

ProGarda. Natural chlorine, chlorate, QAC and sythetic free process washing aids for the food industry

Bio-Burden Reduction in Biological Laboratories

Designing an effective cleaning procedure for medical devices through laboratory studies

catalyst substrate active site

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

Module 7B DNA Collection, Extraction, and Analysis. Forensic Science Teacher Professional Development

Stripol NI Ultra Product Code: Revised Date: 12/11/2012. Stripol NI Ultra

Principles of Chlorine Dioxide Gas as a Decontamination Method

A Better Way to a Healthier Environment ENHANCING BRAND CONTROLLING COSTS & PROTECTING HUMAN HEALTH

AFFINITY HIS-TAG PURIFICATION

511 ULTRAKOOL SS DESCRIPTION:

SEASTROM Manufacturing Co., Inc Seastrom Street Twin Falls, Idaho Fax (208)

TEXTILE INDUSTRY AND ENVIRONMENT. W.J.K.Dushyanthi Ranpatige Research Officer Industrial Technology Institute

The stainless steels used in the manufacture of surgical instruments can be divided into two main classes.

LIQUID PENETRANTS USER S MANUAL in accordance to specifications: EN 571, ASTME 1417, AMS 2644, MIL, ASME, DIN, UNI, BS, AFNOR, etc..

Water The Universal Solvent

Ideal Sterilization Method. Sterilization. Sterilization Practices in Healthcare Facilities

Endoscope Washer Disinfector Cleaning Process Challenge Devices Research & Validation

Low Temperature Processing. An Update on Guidelines, Standards and Requirements

Loaner Programme Guidance

Loaner Programme Guidance

Monitoring your decontamination and reprocessing cycle

ENDOSCOPE REPROCESSING AND INFECTION CONTROL FOR ENDOSCOPY

: Focus MP 11 Multi-Purpose Cleaner

ABCs of Validation. Ruth L. Petran. Corporate Scientist, Food Safety 03 April 2012

March 28, 2019 Maintaining a Clean Brewery Presenter: Richard Rench Q&A Session

0 50 Very soft Soft Medium Hard

SANITIZING OF MILK CASE WASHERS AND TRANSPORT CONVEYORS: AN OVERVIEW OF CURRENT PRACTICES AND ADVANTAGES OF CHLORINE DIOXIDE USE

PowerMax Soil DNA Isolation Kit

Decontamination of Reusable Medical Devices: A Risk Management Perspective. By Paul Holland

We combine enzymes and chemistry to enable the next level of low temperature washing with Lavergy Pro 104 L

Introduction. Kit components. 50 Preps GF-PC-050. Product Catalog No. 200 Preps GF-PC Preps GF-PC Preps SAMPLE

BREW. Protect Your Brand! Craft Brewery Sanitation Program. Complete Line of Cleaners/Sanitizers SSOP Support GHS Training Local Deliveries/Support

3034 Owen Drive Antioch, TN USA Fax: Maybachstraße 10. Revised 01/17

Responses to Questions for SYSTEM 1E Process Monitoring and Validation Webinar

Transcription:

Breaking the Myth Case Medical Page 1 Our Position Caustic cleaners are unnecessary for instrument processing and present significant hazards to health and safety Properly formulated ph neutral instrument chemistries with excellent surfactants and synergistic enzymes can offer a safe and proven alternative The need to provide validated cleaning protocols for reusable medical devices has become a focal point in medical device reprocessing. Page 2 page 1

Sustainability Meeting the needs of our current generation without impacting the needs of future generations to meet their own needs Social responsibility to protect the public from exposure to harm All manufacturers are obligated to design instrument chemistries to control measures which may lead to possible harm. Page 3 Precautionary Principle Ethical responsibility to maintaining the integrity of natural systems Willingness to take action in advance of definitive scientific proof when a delay could prove costly to society and nature as well as selfish to future generations Page 4 page 2

Breaking the Chain Cleaning, decontamination and subsequent sterilization are essential steps in breaking the chain of infection. Page 5 Cleaning The removal, usually with detergent and water, of adherent visible soil such as blood, protein substances and other debris from the surfaces, crevices, serrations, joints and lumens of instruments, devices and equipment by a manual or mechanical process that prepares the items for safe handling and further decontamination. Page 6 page 3

Ineffective Cleaning Can affect the ability of medical devices To function properly Decreases the useful life of the device Increases costs for repair and replacement Can interfere with the effectiveness of subsequent sterilization or disinfection Increases the risk of nosocomial infection Page 7 Green Chemistry Chemical products and processes designed to reduce or eliminate hazardous substances Pollution prevention focus of EPA s Green Chemistry program Page 8 page 4

Caustic Cleaners Alkaline detergents followed by acid neutralizers Present hazards to waste water stream Cause pitting and corrosion of surgical devices May result in safety issues for patients and staff Page 9 Warning The use of elevated temperatures in a cleaning process will cause denaturation and precipitation of soil components (blood) and make them more difficult to remove. Page 10 page 5

Ideal Cleaning Agents Non-corrosive Free-rinsing Non-abrasive Low-foaming Biodegradable Environmentally Friendly Nontoxic in specified use dilution Provide for rapid soil dispersion or suspension May be used in all water types Page 11 Cleaning Reusable Devices The critical first step in the decontamination process Multi-step process including manual and automated cleaning Followed by a thorough rinse with high purity water Manual cleaning dependent on individual s performance. Mechanical reproducible. Page 12 page 6

Validation The FDA places primary responsibility for developing and validating methods for effective processing of the medical device on the manufacturer of the device. Device manufacturers must provide procedures that must be easily replicated and verified by users Page 13 The Validation Enzymatic detergents are often recommended for cleaning reusable devices. Yet, there was little data to confirm the efficacy of enzymatic detergents for effective soil removal from patient-used medical devices Validation: Simulated-use evaluation of enzymatic cleaning Evaluated static soak, manual cleaning, automated cleaning, and the recommended process Inoculated devices Organic soil reduction Bioburden reduction Page 14 page 7

Validation of Process Pre-cleaning using a ph neutral multienzymatic foam Brief rinse with tap water Ultra sonic cleaning with ph neutral detergent Manual cleaning with ph neutral multienzymatic cleaner Final rinse with tap water Page 15 Results Hemostats soiled with ATS and microorganisms processed by the manufacturer s products and method resulted in a 6 Log 10 reduction bioburden and > 99.9% reduction in organic material post processing. Conclusion The protocol of cleaning that is recommended by the manufacturer provides efficient cleaning of medical devices by providing soil and bioburden reduction. Page 16 page 8

The ph Effect To determine if an increase in ph (alkalinity level) will improve or change the outcome of the cleaning protocol Two parallel studies were conducted of the entire cleaning protocol One using neutral ph detergent One using the same ingredients but with a ph of 9 (alkaline) Page 17 ph Effect Results There was no significant difference in outcome between the ph neutral and the alkaline detergents In fact, there was a slight improvement in efficacy with the ph neutral detergent in replicate studies. Page 18 page 9

Why Use Enzymatic Cleaners? Each enzyme is a catalyst working on a particular substrate much as a lock and key. If one enzyme is used only one type of organic soil will be broken down. Protease breaks down protein Lipase breaks down lipids (fats). Amylase breaks down starch and carbohydrates. Multiple enzymes are needed to attack organic soils, so that they may be washed away. Hot water is not recommended nor needed. Page 19 Why are Detergents Needed? Detergents are required for a thorough cleaning and removal of organic and inorganic soils, detergent residue, including enzymes. They may be used in hot water wash cycles for thermal disinfection. Detergents with chelating and sequestering agents are required for removal of salts, minerals and other hard water ions. In automated systems, when filtered, deionized or RO water systems are used lower concentrations of detergents may be used. Page 20 page 10

What Instrument Manufacturers Say Chemicals used in cleaning and decontamination processes should be able to remove the type of soil found on the item while, at the same time, preserving the integrity of the item. Such cleaning agents should have the following properties: Ability to remove organic and inorganic soil. Ability to prevent deposits from hard water ions. Low foaming. Free rinsing. Neutral ph (range 7-8) Very acid or alkaline solutions can damage the inert layer that keeps stainless steel instruments from corroding. Anodized aluminum containers require ph neutral products for decontamination and to maintain their corrosion resistance and useful life. Page 21 Why Green Products? Environmentally friendly products are safe for the patient, staff, and the community. Color, dye, fragrance mask the degradation of the product (fading, sediment, mold!) and the odor of denatured enzymes. Most water systems in each of our cities limit the level of alkalinity in the water supply to a ph of 8.5, yet the alkaline detergents used may reach a ph of 14, the highest level possible and are dumped in our water supply, destroy medical devices, and if used on patients without rinsing, will cause injury or death. Page 22 page 11

Summary Medical devices are critical for patient care. No instrument company recommends caustic detergents, because of the potential damage to the device. Breaking the myth means that there are instrument chemistries that are ph neutral, validated in independent studies, that are environmentally friendly, safe and effective, and demonstrate efficacy and sustainability. Page 23 page 12