THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

Similar documents
SECTION : FIRE WALL AND FIRE SUPPRESSION REGULATIONS FOR R1-Z, R-2, R-3 ZONING AND PDD CATEGORIES

Updated references to SEI/ASCE 7 to the 2016 edition once it is available.

2018 IBC Chapter 6 Types of Construction

IRC Fire Protection of Floors Code Language 2012 IRC R IRC R302.13

CHAPTER 6 TYPES OF CONSTRUCTION

Interior FRT Wood. References of Previous Model Building Codes

The Lexington Division of Fire and Emergency Services. Fire Chief Robert G. Hendricks

General Building Information

G59 12: Final Decision AMPC1

Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION

[Third Reprint] ASSEMBLY, No. 266 STATE OF NEW JERSEY. 215th LEGISLATURE PRE-FILED FOR INTRODUCTION IN THE 2012 SESSION

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

CHAPTER 6 INTERNATIONAL RESIDENTIAL CODE

Learning Objectives. Copyright Materials MULTI STORY WOOD FRAMED BUILDINGS. Prepared for Wood Products Council. Presented by James E. Churchill, P.E.

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code.

2006 to 2012 IBC. Significant Changes

Rescinds Ordinance Number (CM) EFFECTIVE JANUARY 1, Table of Contents

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

FIRE AND SMOKE PROTECTION FEATURES

* RESIDENTIAL PLAN REVIEW *

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE

SECTION 702 DEFINITIONS

ORDINANCE NO * * * THE BOARD OF SUPERVISORS OF THE COUNTY OF SAN JOAQUIN, STATE OF CALIFORNIA, DOES ORDAIN AS FOLLOWS:

International Building Code Essentials for Wood Construction

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

CODE 101 How To Read The California Building Code

Pg. xiv, xv Definitions. Pg. 2 A brief history pg. 12 Codes definition. Pg. 13 The principal purpose of code. Pg. 16 IBC. PG. 27 PG.

WORKSHOP Progressive Multi- Family Design: New Opportunities for Light Frame Mid-Rise Structures

A BILL FOR AN ORDINANCE

2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Learning Objectives. Copyright Materials NONSTRUCTURAL PROVISIONS FOR MULTI STORY WOOD FRAMED BUILDINGS 2009 WASHINGTON STATE BUILDING CODE (WSBC )

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

Plan Check No. Checked by: An Appointment Is Required for Verification

2012 IBC Inspection of Fire-resistance Rated Walls

Department of Public Safety and Corrections Uniform Construction Code Council. Uniform Construction Code (LAC 55:VI.301)

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

ORDINANCE NO. 16- The City Council of the City of West Hollywood does hereby ordain as follows:

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

Fire Retardants and Truss Design. Overview

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

VERTICAL OPENINGS STUDY GROUP REPORT TO CTC MEETNG CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES

Introduction. This Part One will address; Type 1 Fire Resistive and Type 2 Noncombustible buildings.

Interior FRT Wood. References to ICC Building Codes

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

California Residential Code (CRC) Summary of Town of Tiburon Amendments

UNDERSTANDING THE MASS TIMBER CODE PROPOSALS. A Guide for Building Officials

INTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004

BOARD OF COUNTY COMMISSIONERS SARPY COUNTY, NEBRASKA

The Building Code for Rookies

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD BUILDING ADDRESSING

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

PLASTIC CHAPTER 26. SECTION 2602 DEFINITIONS Definitions. The following terms are defined in Chapter

Administrative Changes

CODE ACTION AMENDMENTS

CALIFORNIA BUILDING AND SAFETY COMMISSIONERS BUILDING AND SAFETY 201 NORTH FIGUEROA STREET LOS ANGELES, CA 90012

Chapter 4 Test. Directions: Write the correct letter on the blank before each question.

Copyright Materials. Learning Objectives. Design is in the Details: Solutions to Common to Mid Rise Design. Challenges

FS , 712, 713, 714

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1

PERMIT SUBMITTAL GUIDE FOR COMMERCIAL PROJECTS

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 301

The International Building Code (IBC ) is a model code that provides minimum requirements to safeguard the public health, safety and general welfare

HALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE

Module 8: Ontario Building Code Fire and Spatial Separations

635 BUREAU OF BUILDING CODES AND STANDARDS MAINE UNIFORM BUILDING AND ENERGY CODE - COMMERCIAL BUILDING CODE OF MAINE

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

Prescriptive and Engineered Design Provisions of the Massachusetts One- and Two-Family Dwelling Code

UCC Permit Application Procedures

MVRTA Newburyport Intermodal Parking Facility Newburyport, Massachusetts

CITY SECTION 701A 702A. of this chapter. Protection

FIRE AND SMOKE PROTECTION FEATURES

Outcomes of ICC Tall Wood Ad Hoc Committee: Proposals and Discussion

City of Bemidji Building Office City Hall 317 4th Street NW Bemidji, Minnesota Phone Fax emi mn s

Knowledge Objectives (3 of 3)

Permit and Application Fee Schedule Plan Review Fees are in addition to permit application fees.

STAFF REPORT CITY OF SOLANA BEACH

WoodWorks. Learning Objective. Presentation Overview. Fire Protection II Requirements for rated assemblies and common detailing

Los Angeles Planning and Zoning. The following regulations shall apply to the RE Residential Estate Zone:

AN ORDINANCE AMENDING TITLE 10 (BUILDING REGULATIONS)

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

CODE ANALYSIS REPORT SECOND FLOOR

PRESCRIPTIVE COMPLIANCE METHOD

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

FIRE AND SMOKE PROTECTION FEATURES

INTERIOR FINISHES CHAPTER 8

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

2012 NC Building Code Table Required Separation of Occupancies. ( Item B-1)

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board.

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

ADMINISTRATIVE BULLETIN. TITLE : Procedures for Implementation of SFBC Chapter 34B

ONE AND TWO FAMILY DWELLING PERMIT APPLICATION REQUIREMENTS

ORDINANCE NO. 7,577 N.S.

DRAFT ORDINANCE NO. RD:JAC:CER 9/1/2016

2009 IBC/IFC Photoluminescent Signs & Pathway Marking Systems Frequently Asked Questions

[HCD] This symbol within a section identifies which State agency(s), by its acronym, has amended a section of the model code.

FIRE-RESISTANCE-RATED CONSTRUCTION

Transcription:

DRAFT ORDINANCE FIRE SAFETY V3 06-26-2017 An ordinance amending Subsections SEC. 91.703 of Article I of Chapter IX of the Los Angeles Municipal Code to address FIRE SAFETY of residential use structures with habitable space more than 2 dwelling units. (Also referenced by this ordinance is Section 91.104.2.6. Alternate Materials, Alternate Design and Methods of Construction. New or alternate materials and methods of construction may be approved by the department in accordance with the provisions of Article 8, Chapter IX of the Los Angeles Municipal Code.) THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Subsections SEC. 91.703 of Article I of Chapter IX of the Los Angeles Municipal Code is amended to read as follows: XX.XXXX.XX. Time Limits for Compliance. The owner of land with planned construction after the date of the enactment of this ordinance within the scope of this division shall comply with its requirements. Sec. 2. Subsection XX.XXXX.XX of Section XX.XXXX of Article 1, Chapter IX of the Los Angeles Municipal Code is amended to read as follows: (1)! The following fire resistance standards shall apply to any new proposed building of Residential Group R Occupancies containing sleeping units of more than two dwelling units where the occupants are transient or permanent in nature,. a.! Height and areas limitations if using light-framed, combustible construction: i.! The structure shall not have more than four (4) stories per revised Table 504.4 (Appendix I) ii.! shall not exceed 70 feet above grade plane per Table 504.3 (Appendix II),.

. iii.! shall not exceed allowable area in square feet in area per revised Table Table 506.2 (Appendix III) iv.! shall not have exposed, unprotected framing members b.! An automatic sprinkler system shall be installed throughout the structure in accordance with the requirements of National Fire Protection Association (NFPA) 13, Standard for the Installation of Sprinkler System per Appendix I, II, III.` c.! The number of stories used in determining the minimum type of construction for buildings, including pedestal or podium construction is measured from the grade plane (Delete CaBC Section 510.4 Parking Beneath Group R). d.! Fire Walls serving to create separate buildings for height and area limitations: i.! shall be constructed of noncombustible materials (In CaBC 602.3 FRTW is permitted as (noncombustible) 2-hour rating or less already) ; ii.! shall be constructed with a fire-resistance rating of at least two (2) hours (In Table CaBC 706.4 already); iii.! shall be extended from the foundation to the roof with sufficient structural stability under fire conditions to allow collapse of construction on either side without collapse of the wall, and in accordance with all other requirements for vertical continuity under the code (In CaBC 706.6 Vertical Continuity and CaBC 707.5 Fire Barrier Continuity of Fire Wall section already); e.! Fire Partition Walls serving to separate tenant spaces: i.! shall have a fire resistance rating of not less than two (2) hours (Revise CaBC 708.3 Fire Partitions, Fire resistance rating); ii.! serving as corridor walls as a means of egress shall have a fire resistance rating of not less than one (1) hour (Revise CaBC 708.3.1). f.! Each horizontal separation, installed between floors separating dwelling units, shall be constructed of noncombustible materials, and shall be constructed as a horizontal assembly with a fire-resistance rating of at least two (2) hours and in accordance with all other requirements for horizontal assemblies under the code (in Table 707.3.10 Fire Barriers Assemblies or Horizontal Assemblies already). g.! Fire Watch Guard. A project under construction utilizing light frame, combustible construction shall not proceed unless an approved fire watch guard is present 24 hours a day until the final sprinkler inspection has been completed and a certificate of occupancy is issued (already in California Fire Code Section 202, 901.7).

i.! ii.! iii.! iv.! v.! vi.! The Fire watch guards shall not be assigned any other responsibilities as this would interfere or prevent them from carrying out their required duties. The fire watch guard shall maintain a record of activities performed in connection with the construction project that serve as a potential threat to fire safety. The records shall be submitted to the Division of Fire Safety in the department on a weekly basis and the division may, in its discretion, take action appropriate to abate any fire safety issues, including, but not limited to, requesting that the local construction code official revoke the construction permit for the project. Certificate of Fitness. An applicant shall be eligible to be a Fire watch if the person holds a Certificate of Fitness and is trained in and responsible for maintaining a fire watch and performing such fire safety duties as may be prescribed by the commissioner. A developer or owner of a project under construction utilizing fire watch guard pursuant to this subsection shall be responsible for hiring, training, and compensating the fire watch and any expense to ensure they are on site, including inspection by Local Officials. The Fire Department (or Fire Marshal) may assess a developer or owner of a multiple dwelling, utilizing a fire watch pursuant to this subsection, reasonable administrative fees incurred by the department in performing its duties as set forth in this subsection. h.! Identifying Emblem. The City shall promulgate rules and regulations to require that an identifying emblem be affixed to the front of each exterior entrance of structures that utilize light frame, combustible construction and/or truss construction to clearly communicate that the combustible structure in the affected area is known to the state to pose a fire hazard or threat. i.! The emblem shall be of a bright and reflective color, or made of reflective material. ii.! Placards delineating the primary structural system of the building in accordance with the following shall be installed in an approved location adjacent to the fire alarm control panel and mounted on an exterior wall within 10 feet of the main entrance to the building. Building placards shall be at least

8 inches high by 11 inches long (203 mm by 610 mm) in size with a white background, black letters and a black border. The letters and border shall be visible and readable at 10 feet (3048 mm) and letters shall be in boldface font and not less than 72 point font type size. i.! The placard shall state one of the following descriptions:! Load-bearing concrete walls! Load-bearing masonry walls! Load-bearing steel stud walls! Load-bearing light-framed combustible walls! Structural concrete frame! Structural steel frame, or! Timber/cross laminated timber! And continue with the following text on subsequent lines: serve(s) as the primary structural system of this building. Where the primary structural system is not one of the systems listed, the description shall be approved by the building code official (2) The California Building Standards Commission shall pursuant to Section (1) above adopt revisions to the 2016 California Building Code, Part 2, Volume 1 for the purpose of regulating the structural design, construction, maintenance and use of new lightweight, combustible buildings or structures to be erected in the City of Los Anges. Prior to the revision of said code, the commission shall consult with the code advisory board and other departments, divisions, bureaus, boards, councils or other agencies of city government heretofore authorized to establish or administer construction regulations.

Definitions: Dwelling unit means a single unit providing complete, independent living facilities for one or more persons living as a single housekeeping unit, including permanent provisions for living, sleeping, eating, cooking, and sanitation. Fire barrier means a fire-resistance rated wall assembly of materials designed to restrict the spread of fire in which continuity is maintained. Fire wall means a fire-resistance rated wall having protected openings, which restricts the spread of fire and extends continuously from the foundation to or through the roof, with sufficient structural stability under fire conditions to allow collapse of construction on either side without collapse of the wall. Horizontal assembly means a fire-resistance rated floor or roof assembly of materials designed to restrict the spread of fire in which continuity is maintained. Horizontal separation means a floor assembly separating dwelling units in the same structure, a floor assembly separating sleeping units in the same structure, and a floor assembly separating dwelling or sleeping units from other occupancies contiguous to them in the same structure. Light-frame, combustible construction means a type or construction the vertical and horizontal structural elements of which are primarily formed by a system of repetitive wood framing members or that utilizes metal-plate-connected wood trusses, metal-plate-connected metal-web wood trusses, pin-end connected steel-web wood trusses, wooden I-joists, solid-sawn wood joists, composite wood joists as floor or roof system structural elements, or load bearing elements made of combustible materials, including fire retardant treated wood. Residential use structure means a hotel or multiple dwelling, as those terms are defined in Los Angeles Building Code, Section XX.XXXX. Separation wall means a wall separating dwelling units in the same structure, a wall separating sleeping units in the same structure, and a wall separating dwelling or sleeping units from other occupancies contiguous to them in the same structure. Sleeping unit means a room or space in which people sleep, which can also include permanent provisions for living, eating, and either sanitation or kitchen facilities but not both, but does not include such a room or space that is also part of a dwelling unit.

! APPENDIX(I( REVISED!2016!CALIFORNIA!BUILDING!CODE!FOR!CITY!OF!LOS!ANGELES! TABLE(504.4(ALLOWABLE(NUMBER(OF(STORIES(ABOVE(GRADE(PLANE(! TYPE(OF(CONSTRUCTION( OCCUPANY( TYPE(I( TYPE(II( TYPE(III( TYPE(IV( TYPE(V( CLASSIFICATION( (( A( B( A( B( A( B( HT( A( B(!!!!!!!!!!!!!!!!!!!!!! NS 1! UL! 11! 4! 4! 4! 3! 2! 4! 4! 4! 4! 4! 4! 4! 3! 2! R71! S!(without!area!increase)! UL! 12! 5! 5! 5!4! 5!4! 5!4! 4! 3! R72! R72.1! R73,!R3.1! R74! S!(with!area!increase)! UL! 11! 4! 4! 4! 4! 4! 3! 2! NS 1! UL! 11! 4! 4! 4! 4! 3! 2! 4! 4! 4! 4! 4! 4! 4! 3! 4! S!(without!area!increase)! UL! 12! 5! 5! 5!4! 5!4! 5!4! 4! 3! S!(with!area!increase)! UL! 11! 4! 4! 4! 4! 4! 4! 2! NS 1! UL! 6! 3! 3! 3! UL! 4! 3! 3! 3! S! UL! 6! 3! 3! 3! NS 1! UL! 11! 4! 4! 4! 3! 3! S13D! 4! 4! 4! 4! 4! 4! 4! 3! 3! 4! 4! 4! 4! 4! 4! 4! S! UL! 12! 5! 5! 5!4! 5! 5!4! 4! 4! NS 1! UL! 11! 4! 4! 4! 3! 2! S13D! 4! 4! 4! 4! 4! 3! 2! 4! 4! 4! 4! 4! 4! 4! 3! 2! S! UL! 11! 4! 4! 4! 3! 2! 1.! New!Group!R!required!to!have!sprinklers;!NS!only!used!for!existing!buildings!! 2.! NS!=!Buildings!not!equipped!throughout!with!an!automatic!sprinkler!system;!=!Not!Permitted;!UL!=!Unlimited! 3.! =!Buildings!a!maximum!of!one!story!above!grade!plane!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.1!(NFPA!13);!! 4.! SM!=!Buildings!two!or!more!stories!above!grade!plane!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.1!!(NFPA!13);!! 5.! S!=!Buildings!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.1!(!(NFPA!13).!! 6.! =!Buildings!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.2!(!(NFPA!13R).!! 7.! S13D!=!Buildings!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.3!(!(NFPA!13D).!! 8.! R72.1!=!R72!with!24!hour!supervision!;!R73.1!=!R73!with!24!hour!supervision!!!

APPENDIX(II( REVISED!2016!CALIFORNIA!BUILDING!CODE!FOR!CITY!OF!LOS!ANGELES! TABLE(504.3(ALLOWABLE(BUILDING(HEIGHT(IN(FEET(GRADE(PLANE( TYPE(OF(CONSTRUCTION( OCCUPANY( TYPE(I( TYPE(II( TYPE(III( TYPE(IV( TYPE(V( CLASSIFICATION( (( A( B( A( B( A( B( HT( A( B(!!!!!!!!!!!!!!!!!!!!!! NS i! UL! 160! 65! 55! 65! 55! 65! 50! 40! R71! 60! 60! 60! 55! 60! 55! 60! 50! 40! S!(without!area!increase)! UL! 180! 85! 75! 85!70! 75!70! 85!70! 70!60! 60! R72! R73,!R3.1! R2.1,!R74! S!(with!area!increase)! UL! 160! 65! 55! 65! 55! 65! 50! 40! NS i! UL! 160! 65! 55! 65! 55! 65! 50! 40! 60! 160! 60! 55! 60! 55! 60! 50! 40! S!(without!area!increase)! UL! 60! 85! 75! 85!70! 75!70! 85!70! 70!60! 60! S!(with!area!increase)! UL! 180! 65! 55! 65! 55! 65! 60! 40! NS i! UL! 160! 65! 55! 65! 55! 65! 50! 40! 60! 60! 60! 60! 60! 60! 60! 50! 40! 60! 60! 60! 60! 60! 60! 60! 60! 60! SM! UL! 180! 85! 75! 85!70! 75!70! 85!70! 70! 60! NS i! UL! 160! 65! 55! 65! 55! 65! 50! 40! 60! 60! 60! 55! 60! 60! 60! 50! 40! 60! 60! 60! 55! 60! 55! 60! 50! 40! SM! UL! 160! 65! 55! 65! 55! 65! 50! 40!! 1.! New!Group!R!required!to!have!sprinklers;!NS!only!used!for!existing!buildings!! 2.! NS!=!Buildings!not!equipped!throughout!with!an!automatic!sprinkler!system;!=!Not!Permitted;!UL!=!Unlimited! 3.! =!Buildings!a!maximum!of!one!story!above!grade!plane!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.1!(NFPA!13);!! 4.! SM!=!Buildings!two!or!more!stories!above!grade!plane!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.1!!(NFPA!13);!! 5.! S!=!Buildings!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.1!(!(NFPA!13).!! 6.! =!Buildings!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.2!(!(NFPA!13R).!! 7.! S13D!=!Buildings!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.3!(!(NFPA!13D).!! 8.! R72.1!=!R72!with!24!hour!supervision!;!R73.1!=!R73!with!24!hour!supervision!!!

APPENDIX(III( REVISED!2016!CALIFORNIA!BUILDING!CODE!FOR!CITY!OF!LOS!ANGELES! TABLE(506.2(ALLOWABLE(AREA(FACTOR((AT=NS,(S1,(S13R,(SM,(as(applicable)(IN(SQUARE(FEET( TYPE(OF(CONSTRUCTION( OCCUPANY( TYPE(I( TYPE(II( TYPE(III( TYPE(IV( TYPE(V( CLASSIFICATION( (( A( B( A( B( A( B( HT( A( B(!!!!!!!!!!!!!!!!!!!!!! R71! R72! R72!Type!VA! construction! NS i! UL! UL! 24,000! 16,000! UL! UL! 96,000! 64,000! UL! UL! 72,000! 48,000! 24,000! 16,000! 20,500! 12,000! 7,000! 24,000! 96,000!! 72,000!! 16,000! 64,000!! 20,500! 82,000!! 61,500!! 12,000! 48,000!! 7,000! SM!(with!height!increase)! UL! UL! 24,000! 16,000! 24,000! 16,000! 20,500! 12,000! 7,000! NS i! UL! UL! 24,000! 16,000! UL! UL! 96,000! 64,000! UL! UL! 72,000! 48,000! 28,000! 21,000! 24,000! 16,000! 20,500! 12,000! 7,000! 24,000! 96,000!! 72,000!! 16,000! 64,000!! 48,000! 20,500! 82,000!! 61,500!! 12,000! 48,000!! 7,000! 28,000!! SM!(with!height!increase)! UL! UL! 24,000! 16,000! 24,000! 16,000! 20,500! 12,000! 7,000! NS i! 12,000! SM!(with!height!increase)! 12,000! 48,000!! 21,000!

R72.1! R73,!R3.1! R74! NS i! UL! 55,000! 19,000! 16,500! 16,500! UL! 55,000! 19,000! UL! 220,000! 76,000! 40,000! UL! 165,000! 57,000! 30,000! 16,500! 66,000!! 49,500!! 40,000! 30,000! 72,000!! 54,000!! 16,500! 42,000!! SM!(with!height!increase)! UL! 55,000! 19,000! 16,500! 16,500! NS i! S13D! SM! NS i! 18,000! 13,500! UL! UL! UL! UL! UL! UL! UL! UL! UL! UL! UL! 24,000! 16,000! UL! UL! 96,000! 64,000! UL! UL! 72,000! 48,000! 24,000! 16,000! 20,500! 12,000! 7,000! 24,000! 96,000!! 16,000! 64,000!! 20,500! 82,000!! 12,000! 48,000!! 7,000! SM!(with!height!increase)! UL! UL! 24,000! 16,000! 24,000! 16,000! 20,500! 12,000! 7,000! 1.! New!Group!R!required!to!have!sprinklers;!NS!only!used!for!existing!buildings!! 2.! NS!=!Buildings!not!equipped!throughout!with!an!automatic!sprinkler!system;!=!Not!Permitted;!UL!=!Unlimited! 3.! =!Buildings!a!maximum!of!one!story!above!grade!plane!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.1!(NFPA!13);!! 4.! SM!=!Buildings!two!or!more!stories!above!grade!plane!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.1!!(NFPA!13);!! 5.! S!=!Buildings!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.1!(!(NFPA!13).!! 6.! =!Buildings!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.2!(!(NFPA!13R).!! 7.! S13D!=!Buildings!equipped!throughout!with!an!automatic!sprinkler!system!installed!in!accordance!with!Section!903.3.1.3!(!(NFPA!13D).!! 8.! R72.1!=!R72!with!24!hour!supervision!;!R73.1!=!R73!with!24!hour!supervision! 72,000!! 48,000! 61,500!! 28,000!! 21,000!!