Seismic Diagnosis and Structural Performance Evaluation of Existing Timber Houses in Tokyo Part 3 Case Study on Low-Rise Apartment Houses

Similar documents
E-DEFENSE EXPERIMENTS ON FULL-SCALE WOODEN HOUSES

EXPERIMENTAL STUDY ON THE PERFORMANCE OF THE RC FRAME INFILLED CAST-IN-PLACE NON- STRUCTURAL RC WALLS RETROFITTED BY USING CARBON FIBER SHEETS

Damage ratio functions of buildings using damage data of the 1995 Hyogo-Ken Nanbu earthquake

The Evaluation for the Structural Performance of Traditional Townhouses with Timber Through Columns in Japan

Reference 2. Seismic Retrofitting Promotion Plan and its Implementation of TMG CONTENTS. Now

Guidelines for Assessing Seismic Resistance of Important Cultural Properties (Buildings)

THE DESIGN AND INSTALLATION OF A FIVE-STORY NEW TIMBER BUILDING IN JAPAN

JCI Activity on ISO Standard for Seismic Evaluation of Concrete Structures. Masaomi Teshigawara 1

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

STRUCTURAL IMPROVEMENT OF UN-REINFORCED MASONRY HOUSES IN EARTHQUAKE PRONE REGIONS: PROPOSAL OF AN EFFECTIVE AND AFFORDABLE REINFORCEMENT

SEISMIC STRENGTHENING OF A SCHOOL BUILDING DAMAGED BY THE 2004 NIIGATA-CHUETSU EARTHQUAKE

GUIDELINE FOR POST-EARTHQUAKE DAMAGE EVALUATION OF RC BUILDINGS IN JAPAN

Home Not Anchored to Foundation

Japanese Lessons on RC building collapse and importance of beam-column joint

Project Seismic Vulnerability Assessment For SFCC District Building 33 Gough Street San Francisco, California 94103

FULL SCALE STATIC LOADING TESTS FOR TWO STORIED PLANE FRAME OF TRADITIONAL TOWN HOUSE IN KYOTO, JAPAN

Seismic Diagnosis and Structural Performance Evaluation of Existing Timber Houses in Tokyo Part 5 Application of Microtremor Measurement

RESULTS OF FIRST RECONNAISSANCE ON DAMAGE TO REINFORCED MASONRY BUILDINGS AND GARDEN WALLS CAUSED BY THE GREAT EAST JAPAN EARTHQUAKE IN 2011

EXPRIMENTAL AND ANALYTICAL STUDY ON SEISMIC BEHAVIOR OF TRADITIONAL WOODEN FRAMES CONSIDERING HORIZONTAL DIAPHRAGM DEFORMATION AND COLUMN SLIPPAGE

EXPERIMENTAL STUDY ON DYNAMIC BEHAVIOR OF WOODEN FRAMES WITH PASSIVE CONTROL SYSTEM AND INNER-AND-OUTER WALLS USING SHAKING TABLE

SEISMIC RETROFITTING OF EXISTING BUILDINGS

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

STUDY ON HORIZONTAL STRENGTH OF TRADITIONAL WOODEN HOUSES BY TESTS IN SITES

ENG.ACA.0001F Madras. New Zealand significant. (a) spandrel 2010) were solid

Gravity Load Collapse of Reinforced Concrete Columns with Brittle Failure Modes

SEISMIC EVALUATION AND RETROFIT PLAN OF EXISTING REINFORCED CONCRETE BUILDINGS OF ALGIERS IN ALGERIA

VERIFICATION OF SEISMIC REINFORCEMENT ON OLD WOOD HOUSES BY USE OF E-DEFENSE

4. BUILDINGS, DWELLINGS AND BRIDGE

13.4 FOUNDATIONS FOR SINGLE-FAMILY HOUSES

Miss. Sayli S Kamble. 1, Prof. Dr. D. N. Shinde 2 1 Department of civil Engineering, PVPIT Budhgaon, Shivaji university, Maharashtra, India.

Professor Masato Motosaka, Tohoku University (Translated by Shunsuke Otani, University of Tokyo)

SEISMIC PERFORMANCE EVALUATION OF A TYPICAL LOW-RISE REINFORCED CONCRETE BUILDING IN THE PHILIPPINES

Guidelines for Ensuring Safety of Cultural Properties (Buildings) During Earthquakes

Note on the assessment:

Quantification and Interregional Comparison of Structural Characteristics of Traditional Wooden Houses in Japan

7 NON-STRUCTURAL ELEMENTS

INSTRUCTORS GUIDE. FEMA P-593 CD, Seismic Rehabilitation Training for One- and Two-Family Wood-Frame Dwellings

DECONSTRUCTION PROJECT TO EVALUATE THE RECYCLABILITY/REUSABILITY OF THE COMPONENTS AND MATERIALS IN WOODEN HOUSES

Development of Cylindrical Passive Damper using High Damping Rubber

PRINCIPLES FOR THE CONSERVATION OF WOODEN BUILT HERITAGE

DYNAMIC LOADING TEST ON RC FRAME RETROFITTED BY OUTER CES FRAME

Seismic Response of RC Frame Buildings with Soft Storeys

Research on seismic behavior of Wood-Concrete Hybrid Structure

Strengthening or Retrofitting

Structural Inspection

SUMMARY 1. INTRODUCTION LEARNING FROM THE HYOGOKEN-NANBU EARTHQUAKE

Comparative Cost Analysis of Possible Seismic Retrofitting Schemes for Multi-Story Unreinforced Masonry Building

A Study on Vibration Performances of Japanese Traditional Timber Buildings based on Microtremor Measurements

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

Engineering Geology and Seismology. Structural Geology

Proposed Damage Function for Existing RC Residential Buildings in Almaty, Republic of Kazakhstan

STRUCTURAL EVALUATION OF DOVER ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

Post-Frame Construction and the International Building Code By Amanda Stauffer

KEEP YOUR FAMILY SAFER FROM EARTHQUAKES AND TYPHOONS BY MAKING SURE YOUR HOUSE FOLLOWS THESE 6 BASIC PRINCIPLES

Assist. Prof., Faculty of Engineering, Hokkaido University, Japan 3

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

Shaking Table Test of Two-Story Masonry House Model Retrofitted by PP-band Mesh

Strengthened and rehabilitation of Transylvanian saxon house

Report on Building Damage in Central Ibaraki Prefecture by The 2011 off the Pacific Coast of Tohoku Earthquake Released on April 3, 2011

Seismic Collapsing Analysis of Two-Story Wooden House, Kyo-machiya, against Strong Earthquake Ground Motion

Earthquake resistance of a historical brick building in Akita Prefecture, Japan

Shaking table test on seismic response behavior of 2-story masonry house model with PP-band mesh retrofitting

STRUCTURAL EVALUATION OF WASHINGTON ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

SEISMIC RETROFIT OF RC SCHOOL BUILDINGS USING POST-INSTALLED WALLS WITH OPENINGS

Council on Tall Buildings. and Urban Habitat BACKGROUND SECTION STEEL REINFORCED CONCRETE SHEAR WALL STEEL PLATE COMPOSITE SHEAR WALL

RESIDENTIAL SEISMIC RETROFITS

Plan Check No. Checked by: An Appointment Is Required for Verification

A proposal on the simplified structural evaluation method for existing reinforced concrete buildings in Bangladesh

Report on Building Damage in Northern Ibaraki Prefecture by The 2011 off the Pacific Coast of Tohoku Earthquake Released on March 30, 2011

SHEAR BEHAVIOR OF MULTI-STORY RC STRUCTURAL WALLS WITH ECCENTRIC OPENINGS

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING

Commercial Structures

SEISMIC SAFETY IMPROVEMENT OF HOUSING SECTOR IN THE HISTORICAL CENTER OF THE CITY OF SANTA TECLA IN EL SALVADOR

STRUCTURAL EVALUATION OF TARA HILLS ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

Pushover Analysis Of RCC Building With Soft Storey At Different Levels.

STRENGTH AND DUCTILITY OF RETROFITTED R/C BUILDING BY MULTI-STORY STEEL-BRACED FRAME SUBJECTED TO TRI-LATERAL EARTHQUAKE LOADING

Civil Engineering. Civil Engineering Civil engineering is considered to be the oldest field in engineering. still the same: Civil engineering is the.

SEISMIC-FORCE-RESISTING MECHANISMS OF MULTI-STORY STRUCTURAL WALLS SUPPORTED ON PILES ABSTRACT

Earthquake resistance of a historical brick building in Akita Prefecture, Japan

EXPERIMENTAL STUDY OF THE DEFORMATION CAPACITY OF STRUCTURAL MASONRY

Structural Design of Super High Rise Buildings in High Seismic Intensity Area

The 2007 Noto Peninsula, Japan Earthquake (M w 6.7): Damage to Wooden Structures

STRUCTURAL PERFORMANCE OF MIXED MEMBER COMPOSED OF STEEL REINFORCED CONCRETE AND REINFORCED CONCRETE

A Study on Structural Timber Bearing Wall with Additional Performances

Seismic Collapsing Process Analysis of One-story Thatched Roof Wooden Structure under Strong Earthquake Ground Motion

SEISMIC REHABILITATION OF TRADITIONAL UN-REINFORCED MASONRY BUILDINGS IN IRAN

Distribution of Forces in Lateral Load Resisting Systems

Detailed Assessment of St. Patrick Church, Paraparaumu, NZ. 09 January 2013 MIL Phase 05

UNREINFORCED MASONRY STRUCTURES -PART I - DEFINITIONS AND PROBLEMS UNDER LATERAL LOADS

EXPLORATION OF DIFFERENT RETROFITTING OPTIONS FOR RC FRAME BUILDINGS IN KATHMANDU

Study Trip Report on TOHOKU UNIVERSITY: INSPECTION OF DAMAGED BUILDING By: Sergio Sunley (E-Course)

Question 8 of 55. y 24' 45 kips. 30 kips. 39 kips. 15 kips x 14' 26 kips 14' 13 kips 14' 20' Practice Exam II 77

Seismic Performance Evaluation of Traditional Wooden House by Alternate Cyclic Loading Test

NSET EXPERIENCE ON SEISMIC RETROFITTING OF MASONRY AND RC FRAME BUILDINGS IN NEPAL

SEISMIC PERFORMANCE EVALUATION OF RETROFITTED WOODEN-HOUSE BY COLLAPSING PROCESS ANALYSIS

Burbank Municipal Code A300: ADOPTION OF CODE: Page 8 of 13

STUDY ON SEISMIC PERFORMANCE OF LOW EARTHQUAKE RESISTANT MASONRY BUILDINGS RETROFITTED BY PP-BAND MESH

FULL-SCALE DYNAMIC COLLAPSE TESTS OF THREE-STORY REINFORCED CONCRETE BUILDINGS ON FLEXIBLE FOUNDATION AT E-DEFENSE

RESEARCH AND DEVELOPMENT PROGRAMS ON TIMBER STRUCTURES IN JAPAN

Transcription:

Session B-5: Detached Houses Seismic Diagnosis and Structural Performance Evaluation of Existing Timber Houses in Tokyo Part 3 Case Study on Low-Rise Apartment Houses Takamasa Sasaki 1 Kaori Fujita, Dr. Eng 2 Eiko Ishikawa, M. Eng 3 Hiromi Sato, M. Eng 4 1 2 3 4 Graduate Student, Department of Architecture, Graduate School of Engineering, Tokyo Metropolitan University, 1-1 Minamiosawa Hachioji, Tokyo 192-0397 JAPAN, tkms-a-1224@m6.gyao.ne.jp Associate Professor, Department of Architecture, Graduate School of Engineering, the University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656 JAPAN, fujita@arch.t.u-tokyo.ac.jp PhD Candidate, Graduate School of Urban Science, Tokyo Metropolitan University, 1-1 Minamiosawa Hachioji, Tokyo 192-0397 JAPAN, eyureto@cd5.so-net.ne.jp PhD Candidate, Department of Architecture, Graduate School of Engineering, Tokyo Metropolitan University, 1-1 Minamiosawa Hachioji, Tokyo 192-0397 JAPAN, sato-hiromi@ed.tmu.ac.jp Keywords: Seismic Retrofit, Timber Frame Construction, Kyojima Abstract This paper presents the case study of seismic diagnosis and structural strengthening repair work conducted on low-rise timber apartment houses in the downtown district of Tokyo (Sumida Ward, Kyojima). The investigated timber apartment houses are one- to two-story low-rise timber apartment houses built in the middle of the 20 th century. The investigated area is known for its densely populated small timber houses and is estimated to be one of the most vulnerable regions against earthquakes in Tokyo. The results of on-site investigations and a seismic diagnosis of three timber apartment houses revealed that the horizontal load carrying capacity of these houses was far below the required values in Japan s Building Standard Law. The authors conducted structural reinforcement repair work on two of the apartment houses in collaboration with the Center for Urban Development of Kyojima. The structural repair under financial and technological restrictions is discussed together with the need of preserving the cultural background of downtown Tokyo. 1. Introduction Studies of the structural performance and structural reinforcement repair work of existing timber houses has been increasing slowly. Although the existing timber apartment houses suffered heavy damage by earthquakes, no study has yet been conducted. In a previous investigation, the evaluation of structural performance was a seismic diagnosis based on the result of investigations; however, it was difficult to determine the detailed specifications of the foundations and walls and to confirm the deterioration of a structure. Most of the existing timber apartment houses are old; therefore, their specifications are different from those of today and deterioration of hidden members probably exists. There are numerous timber apartment houses in areas with densely packed wooden housing. The Kyojima area is one of these areas. The map of 3-chome, Kyojima is shown in Fig.1. There are low-rise timber apartment houses shown as Photo 1. Useful information is obtained through investigations and reinforcement repair work. By examining this information, the structural characteristics of existing timber apartment houses can then be estimated in other areas. This paper presents the results of the investigation and reinforcement work on the structural problems of three existing apartment houses, and discusses the financial and technological problems of the reinforcement work. 471

Fig.1. 3-Chome, Kyojima Photo 1. The Existing Apartment Houses in Kyojima 2. Methods of Study (1) On-site Investigation To detect the materials and deterioration of the walls and roofs, a non-destructive investigation by measurement and observation was conducted. In addition, another investigation was conducted by interviews with the landlords and residents. (2) Seismic Diagnosis Based on the results of the investigations, a seismic diagnosis was conducted. House N was evaluated by a general diagnosis. Conversely, houses K1 and K2 were evaluated by a general diagnosis and a detailed diagnosis. The two diagnoses have different ways of calculating the horizontal load carrying capacity of the building. The two calculations for horizontal load carrying capacities P d (Q d ) are given in Eq. (1) and (2). General diagnosis: P d = P " E " D (1) where P is the strength, E is the reduction by the arrangement of structural elements, and D is the reduction by deterioration. Detailed diagnosis: Q d = (Q wn + Q ww ) " F s " F e (2) where Q wn is the strength of the walls, Q ww is the strength of the walls with openings, F s is the reduction by the stiffness ratio, F e is the reduction by the eccentricity. In the detailed diagnosis, Q wn and Q ww include the reduction by deterioration. (3) Reinforcement Repair Work Reinforcement repair work was conducted on two of the apartment houses. Detailed investigations accompanied by partial destruction of the members were conducted. 3. Results of Investigation and Seismic Diagnosis Table 1 shows an outline of the apartment houses investigated. The north part of house K2 was not investigated because the resident was very old. House K1 is a popular two-story timber apartment house in Kyojima. House K2 is also a typical one-story timber apartment house in Kyojima. House N is not in the same area. However, the floor space and the specifications of the roof and walls are the same as those of house K1. In some places in Kyojima, tinplate roofing is used instead of tile. The specification of the walls is mainly mud in all three houses. Therefore, this structural element is mainly mud wall. The plans and results of the general diagnosis are shown in Fig. 2. Each result of the general diagnosis is described as follows. 472

Session B-5: Detached Houses Table 1. Investigated Timber Apartment Houses in Tokyo House K1 House K2 House N Reduction of Reduction of Reduction of Reduction of Reduction of Reduction of Evaluation Evaluation Eccentricity Deterioration Eccentricity Deterioration Eccentricity Deterioration Evaluation X 0.45 0.70 0.13 1.00 0.70 0.55 1.00 0.70 0.32 Y 0.80 0.70 0.50 1.00 0.70 0.81 1.00 0.70 0.94 Fig.2. Plans and Evaluations of Seismic Diagnosis (The General Diagnosis) Table 2. The Judgment of Structural Performance Evaluation Judgment 1.5 ~ Safe 1.0 ~ 1.5 Low Possibility of Collapse 0.7 ~ 1.0 Possibility of Collapse ~ 0.7 High Possibility of Collapse (1) House K1: The evaluation in both directions was under 0.7, and the judgment was High Possibility of Collapse. (Table 2) The evaluation was low because the shear walls were not adequate in both directions. Because the reduction of eccentricity was 0.45 in the X direction, the evaluation was 0.13. It is far below the other direction. There was an earthen floor along the road on the east side. The earthen floor did not have a wall in the X direction at all and all the facades along the road were openings. Therefore, the shear walls of the east side did not add enough support and the eccentricity occurred. Also, the strength of the walls had the reduction of connections because the connections had no metal fastener (Photo 2). 473

(2) House K2: The foundation is categorized into three classes according to the specifications. Table 3 shows the three classes of the foundation. The specification of the foundation of house K2 was not clear; therefore, a diagnosis was made by the specifications for Foundation 2 and Foundation 3. Figure 2 shows the evaluation for Foundation 3. The evaluation in the X direction was 0.55, and the judgment was High Possibility of Collapse. The evaluation in the Y direction was 0.81, and the judgment was Possibility of Collapse. The evaluation in the X direction was low because the shear walls were not adequate in the X direction. The Y direction has the reduction by eccentricity. The strength of the walls had the reduction of connections because the specification of the foundations was stone and the connections had no joint metal (Photo 3). (3) House N: The evaluation in the X direction was 0.32, and the judgment was High Possibility of Collapse. The evaluation was low because the shear walls in the X direction were not adequate. The evaluation in the Y direction was 0.94, and the judgment was Possibility of Collapse. The evaluation was nearly 1.0 because the outer walls and the walls on the boundary of the dwelling unit were adequate. Because the rot of the column and the damage of the wall were found by on-site investigation, a reduction by deterioration occurred. Table 3. Specification of Foundation Foundation 1 Foundation 2 Foundation 3 Reinforcement Concrete or Mat Foundation Reinforcement Concrete with a Crack or Mat Foundation with a Crack. Concrete and Stone with Fix The Others Photo 2. Column Base (K1) Photo 3. Column-Beam Connection (K2) 4. Results of Reinforcement Repair Works We conducted two reinforcement repairs. This section reports the plan and a description of the work on house K2. 4.1 Plan There is a resident in the dwelling unit on the north side. The dwelling unit on the south side is used as a nursing care center several times per month. We made a plan to conduct the repair work on only the unit on the south side as the first step of step-by-step repair work. The places of reinforcement were determined with attention to the following points: 1) the Japanese-style room in which a senior citizen resides was reinforced, 2) the places of reinforcement are arranged equally in a plane. Figure 3 shows the places of reinforcement. During the planning of the reinforcement repair work, the landlord hoped to leave the atmosphere as it was and avoid darkening the Japanese-style room. Therefore, No. 2 and No. 4 in Fig. 3 were reinforced by structural plywood with uncovered columns and No. 5 was reinforced by a brace of stainless steel. We conducted the reinforcement on the openings where the sliding door was not usually used (No. 1, No. 3, No. 5). After the reinforcement repair work, the existing foundation was not able to resist the pull-out force of the columns. Therefore, it was replaced with a new reinforced concrete foundation (Fig. 4). 474

Session B-5: Detached Houses Fig.3. Plan of the Reinforcement in House K2 Fig.4. Arrangement of Foundation 4.2 Detailed investigation We dismantled the floor of house K2 and investigated underneath prior to the reinforcement repair work. We found that the foundation was concrete. But, it was too old; therefore, it was removed and a new foundation was added. Also, the sill was decayed intensely; therefore, it was also replaced with a new one. 4.3 The enforcement of the reinforcement work The main work projects are as follows. (1) Foundation work: After the existing foundation and sill were removed, a foundation of reinforced concrete and sill, to which a disinfectant was applied, was added. (2) Reinforcement by structural plywood: In No. 1 and No. 6, structural plywood was nailed on the columns and horizontal members. Whereas, in No. 2, No. 3 and No. 4, structural plywood was fixed on the columns and horizontal members through the member nailed them. A column would show on the surface of the wall by doing this. In addition, work was conducted to maintain Nageshi, horizontal pieces of timber in the frame of Japanese-style houses. For example, opening was replaced with structural plywood in No.1 and mud wall was replaced with structural plywood with uncovered column in No.2 (Fig. 5, Photo 4). Consequently, the atmospheres did not change. Fig.5. Structural Plywood With Uncovered Column (No.2) Before Reinforcement After Reinforcement Photo 4. Reinforcement on No.1 and No.2 475

(3) Openings of reinforcement by brace: In No. 5 the reinforcement was a brace! 9 mm of stainless steel, which does not darken a room. After cutting only the reinforced part of the spandrel wall and locating the column, the brace was installed. The brace touched the existing sash; therefore, the sash was removed. It was fixed on the frame, which was nailed on the column from the outside again (Fig. 6). In addition, the paper sliding door, which became unnecessary by the reinforcement in No.1, was nailed from the inside (Photo 5). (4) Reinforcement by wooden brace: In No. 7 the wooden brace was added (Photo 6). The finish of the outer wall was the wood siding using calcium silicate board. Fig.6. Detailed Section of Stainless Steel Brace Photo 5. Paper Sliding Door (No.5) Photo 6. Reinforcement by Wooden Brace (No.7) 4.4 The evaluation after the reinforcement work Table 4 shows the evaluation of the detailed diagnosis after the reinforcement repair work. The evaluation did not change due to the result of the detailed investigation. However, by using structural plywood for the repair of the external wall on which there was intense damage, the evaluation in the Y direction rose. Table 4. The Evaluation in Each Step Before After Plan Reinforcement Reinforcement X 0.52 0.86 0.86 Y 0.70 0.98 1.13 5. Discussion 5.1 The characteristics of the building Compared with the evaluations of the span direction (Y), the evaluations of the ridge direction (X) were low for all three apartment houses from the result of the seismic diagnosis of each building. The apartment houses have openings in the ridge direction and did not have partitions (Photos. 7 and 8). The evaluation of the span direction (Y) will change depending on whether there is an opening or not in the external wall. In other words, the ridge direction (X) needs to be reinforced in these apartment houses. However, because there are few existing walls, there will be many cases in which there are not enough strength if they are reinforced. Therefore, it is necessary that new structural elements are built in openings which have not been used and on the earthen floors. 476

Session B-5: Detached Houses Photo 7. The Openings in the Ridge Direction (N) Photo 8. Continuous Room (K2) 5.2 Deterioration of the member Detailed investigations by partial destruction of the members were conducted. The surface of the column bases visible on the outside had deteriorated. Most sections of some column bases had termite damage and decay (Photo 9). In addition, the sills decayed in houses K1 and K2 (Photo 10). The height of the beam for the foundation was low; therefore, the sills were decayed from ground moisture. In contrast, the column tops and the horizontal members were not decayed. In a building similar to these, the partial loss of sections by deterioration, which influences the structural performance, may occur in the hidden members. Therefore, the investigation by breaking part into a floor and a wall or using a fiberscope has to be conducted to evaluate their seismic performance correctly. Photo 9. Decayed Column Base Photo 10. Decayed Sill 5.3 The existing foundation Table 5 shows the foundation of the investigated houses. In cases in which the surface of foundation deteriorated and is buried underground, it is difficult to investigate their material. The specification of the foundation is important to make the reinforcement plan. Therefore, it was investigated carefully. Table 5. Foundation of Investigated Houses House K1 House K2 House N Specification of Foundation Stone (oyaishi) Concrete Concrete Method of Investigation Observation and Partial destruction Observation and Partial destruction Observation 5.4 The reinforcement repair work To show the effect of the reinforcement on which there is no foundation means building a new foundation. However, the foundation work greatly influences the time and work cost. The reinforcement to the earthen floor for where there is no floor and no place needs to jack up the building was easy to carry out. Namely, it would reduce time and cost. Therefore, it is necessary to consider the simple reinforcement techniques. The 477

frames were reinforced by structural plywood mainly. Most structural plywood touched the orthogonal walls and beams; therefore, it was nailed through the members or part of the plywood was cut. The horizontal strength of the reinforcement by structural plywood in this case should be evaluated in detail. In the reinforcement by structural plywood with uncovered columns where mud walls were removed, a large quantity of dust resulted. Therefore, it was necessary to devise how to do the work if a resident was living there. In the case that new structural elements were built, e.g., as reinforcement to the earthen floor in K1 (Photos 11 and 12) and reinforcement by brace to the opening in K2 (Photo 13), the designer should determine the place of reinforcement in consultation with the resident about directions for use. These reinforcements are effective for apartment houses that have a long frontage. Photo 11. New Foundation on Earthen Floor (K1) Photo 12. New Structural Element on Earthen Floor (K1) Photo 13. Reinforcement by Stainless Steel Brace on Openings (K2) 6.Conclusion We conducted investigations on three timber apartment houses. In addition, we conducted detailed investigations and structural reinforcement repair work on two of these houses. The seismic performance in the ridge direction of the existing timber apartment houses was generally below the required values in the Building Standard Law. The deterioration of structural members was found by detailed investigation. We needed to evaluate the seismic performance to evaluate the degree of deterioration. The foundation work was conducted with reinforcement of the frames. The reinforcement in the ridge direction was conducted by reinforcement of the openings and earthen floors. The financial and technological problems were understood. In the future, we need to quantify the deterioration found by our detailed investigations and verify the seismic performance and the reinforcement in the ridge direction in these cases. Acknowledgement This study was supported by The 21 st Century COE Program of Tokyo Metropolitan University, Development of Technologies for Activation and Renewal of Building Stocks in Megalopolis. The authors gratefully acknowledge their support. References Bureau of Urban Development, Tokyo Metropolitan Government, The Fifth Result of Measurement of the Area Degree of Risk Committee on Report on the Hanshin-Awaji Earthquake, AIJ, 1998, Report on the Hanshin-Awaji Earthquake Disaster Building Series, Volume 4, Wooden Structure Damage to Building Foundations The Japan Building Disaster Prevention Association, 2004 revised edition, Detailed Seismic Evaluation and Retrofit of Wooden Houses Sasaki, T., Fujita, K., 2006, Study on the Application of Seismic Diagnosis to Existing Wood Apartment Houses, Case Study of Timber Buildings Located in the Metropolitan District. Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, C-1, 267-268 478