P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3.

Similar documents
Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Regency Horizon HZ30E Gas Fireplace

Contemporary Collection

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw)

B36XTCE Gas Fireplace

B41XTCE Gas Fireplace

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection

Gas Fireplaces. B36XTE Gas Fireplace. Unit Dimensions with Vignette: Model B36XTE-NG10 B36XTE-LP10 M O S S. V Opening for gas connection

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

Please consult the manufacturer s installation manual for all details and requirements before making a final design layout decision.

CHIMNEYS AND FIREPLACES


PORTRAIT WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 569 Ledge Front

Builder's Manual for Ortal Fireplaces

CHIMNEYS AND FIREPLACES

Installation Instructions

Technical and Dimensional Data. Saf-T Vent SC

SI T T FST

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

Architect & Builder s Guide. ORTAL Heating Systems Ltd.

FEATURES AND SPECIFICATIONS...2 Installation Choices...2

TC54. for architects & designers. Dimensions Clearances Venting

Installation Manual Installation and Fireplace Setup

SI T T FSS/FSTT Open Fire

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

DirectVent Pro. Simpson Dura-Vent Engineered Excellence

Chimney Lining Systems

Nouveau BBQ Single Flue

Installation Manual Installation and Fireplace Setup

Installation and Operation Manual. Safety tested according to ULC-S610 and UL 127 Standards by an accredited laboratory.

APPLICATION FOR FINISHED BASEMENT PERMIT

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Installation Manual Installation and Appliance Setup

Installation Manual Installation and Fireplace Setup

Residential Building Plans

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Installation Manual Installation and Fireplace Setup

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

GCI60 Hampton Cast Iron Pellet Insert

Installation Manual Installation and Fireplace Setup

Installation Manual Installation and Appliance Setup

Installation Manual Installation and Appliance Setup

APPLICATION AND LISTING

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Installation Manual Installation and Fireplace Setup

TCWS54 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

Installation Manual Installation and Appliance Setup

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

Installation Manual Installation and Fireplace Setup

Regency Bellerive & Berwick Zero Clearance Box and Flue Kit Part No Assembly Instructions

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

Simpson Dura-Vent Engineered Excellence

Kiva Fireplace GAS BURNING INSTALLATION MANUAL

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: EARTHCORE INDUSTRIES, LLC

Installation Manual Installation and Fireplace Setup

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.

Dur aflex stainless steel

Installation Manual Installation and Fireplace Setup

DuraLiner. Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640.

Vent Termination Chart. horizontal Termination Kit A. horizontal Termination Kit C. Chimney Liner Termination Kit. DirectVent Pro Direct Vent

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems)

ENGLISH INSTALLATION INSTRUCTION MANUAL. N550 Bakers Oven. CERTIFIED for USA & CANADA SAFETY TESTED to UL & ULC-S

Installation Manual Installation and Fireplace Setup

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

Block-In Fireplace Masonry Fireplace 36 ELITE-BI INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & November,

Installation Manual Installation and Fireplace Setup

Chimney and Fireplace Inspection Report

170MM 360MM Specifications

DIRECT-TEMP METALBESTOS DIRECT VENT SYSTEM

Wood Designer Series Woodburning Fireplaces

Installation Manual Installation and Appliance Setup

TC30 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

Installation Manual Installation and Fireplace Setup

Fireplaces and Chimneys

Installation Manual Installation and Fireplace Setup

Installation and Operation Manual

Installation Manual Installation and Fireplace Setup

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

the heart of a warm home

pellet stoves & inserts woo

Installation Manual Installation and Fireplace Setup

Installation Manual Installation and Fireplace Setup

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

Administrative Changes

Installation Manual Installation and Fireplace Setup

TC42 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

Z-Vent Model SVE Series III

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7

ATTENTION INSTALLING PERSONNEL

Linear Gas Fireplaces

MASPORT I5000 INSERT FIRE, AUSTRALIAN MODEL

GD Specifications

Standard practice for installing cellulose building insulation

Owner's Manual Residential Factory Built Fireplace. Operation Maintenance Installation FOCUS 250

Transcription:

P36 - P36D Zero Clearance Direct Vent Gas Fireplace Model P36-NG4 P36-LP4 P36D-NG1 P36D-LP1 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3. kpa) 5 W.C. (1.25 kpa) 12 W.C. (3. kpa) Manifold Pressure - High 3.8 W.C. (.95 kpa) 11 W.C. (2.74 kpa) 3.8 W.C. (.95 kpa) 11 W.C. (2.74 kpa) Manifold Pressure - Low 1.1 W.C. (.27 kpa) 2.9 W.C. (.72 kpa) 1.1 W.C. (.27 kpa) 2.9 W.C. (.72 kpa) Orifi ce Size #37 DMS #52 DMS #37 DMS #52 DMS Minimum Input 15,5 BTU/h (4.54 kw) 15, BTU/h (3.96 kw) 15,5 BTU/h (4.54 kw) 15, BTU/h (3.96 kw) Maximum Input 3, BTU/h (8.79 kw) 3, BTU/h (8.79 kw) 3, BTU/h (8.79 kw) 3, BTU/h (8.79 kw) Vent Sizing 4 Inner / 6 5/8 4 Inner / 6 5/8 4 Inner / 6 5/8 4 Inner / 6 5/8 Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent Systems: FPI AstroCap Flex Vent Simpson Dura-Vent Direct Vent GS American Metal Products Ameri Vent Security Secure Vent Selkirk Direct-Temp. B A L Top Header C D F H Drywall (or other facing) 1" (254mm) dia. Hole through wall Vent. A E Unit Dimensions Description P36 P36D A Front Face Width 36 (914mm) 36 (914mm) G I M B Rear Firebox Width 33-1/4 (838mm) 33-1/4 (838mm) C Front Face Height 3-1/2 (775mm) 3-1/2 (775mm) D Height w/ Standoff 36 (914mm) 37 (94mm) E Unit Depth 12-3/4 (324mm) 17-1/8 (435mm) J F Height to Vent 32-1/2 (826mm) 32-1/2 (826mm) Framing Dimensions Description P36 P36D G Framing Width* 36-1/4 (921mm) 36-1/4 (921mm) H*** Framing Height* *** 36-1/4 (921mm)*** 37-1/4 (946mm)*** I Framing Depth* 12-3/4 (324mm) 17-1/8 (435mm) J Corner Wall Length 42-7/16 (178mm) 48 (1219mm) K Corner Facing Wall Width 6 (1524mm) 68 (1727mm) L Framed Chase Ceiling 46 (1168mm) 46-1/2 (1181mm) M Vent Centerline Height 4-1/2 (129mm) 4-1/2 (129mm) N Gas Connection Height 2 (51mm) 2 (51mm) O Gas Connection Inset 3-1/2 (89mm) 3-1/2 (89mm) P Gas Connection Width 4 (12mm) 4 (12mm) *** Important: Framing height requires consideration of the hearth depth. Dimension H = H + the thickness of installed hearth. K N O P Opening for gas connection * If using the Barcelona Surround, Kensington, Balmoral, or Tripoli Screen Door please note that framing and facing must be non combustible (12 on top and 6 on both sides) and that the Barcelona is only approved for installation with a single sidewall. Please refer to Page 11 (Exterior Vent Terminations) for additional guidelines on vent locations. June 27 Regency Product Specifications Book 35

Framing and Finishing 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2 (13mm) to 1-1/4 (32mm) thick. 2) Frame in the enclosure for the unit with framing material. Note: Header for the P36 must be installed vertically to maintain clearances to combustible materials. Non combustible header may be installed horizontally. 3) For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapor barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.) 4) The top of the unit must not be closer than 32 (813mm) to the ceiling. 5) Combustible material may be brought up to the top and sides of the unit and be covered with ceramic tiles, bricks, rock or other suitable combustible fi nishing materials. If using the Barcelona Surround, Kensington, Balmoral, or Tripoli Screen Door please note that framing and facing must be non combustible (12 on top and 6 on both sides) and that the Barcelona is only approved for installation with a single sidewall. Note: The unit does not have to be completely enclosed in a chase. The clearance on top of the unit is to the standoffs so combustible building materials can be laid directly on top of the standoffs. You must maintain proper clearances from the vent to combustible materials (See Below). 6) Use metal studs for framing where the minimum clearance from the vent to combustible material cannot be maintained. Clearance Requirements Vent Clearances Horizontal - Top Horizontal - Side Horizontal - Bottom Vertical (Flex or Rigid) Combustible Mantels Mantel Clearances 12 1 8 6 4 2 B 12" (35mm) A To base of Unit 7-1/2"(191mm) C Top of Unit 3-1/2" (89mm) D Clearance Dimension Drywall Standoff Side View 2 (51mm) 1-1/2 (38mm) 1-1/2 (38mm) 1-1/4 (32mm) WARNING Failure to maintain required clearances is a major cause of chimney related fires. Installation of this fireplace must comply with these clearances. Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher. Mantel Clearances A B C D C A D F with Flush Glass or Hampton Cast with Bay Option with Flush Glass and Barcelona Surround with Tripoli Screen Door, Kensington, or Balmoral Front 3-1/2 (778mm) 3-1/2 (778mm) 3-1/2 (778mm) 3-1/2 (778mm) 14 (356mm) 1 (254mm) 7 (178mm) 13 (33mm) 1 (254mm) 7 (178mm) 17 (432mm) 12 (35mm) 8 (23mm) 2 (58mm) N/A 12 (35mm) B B Note: If desired a non-combustible mantel may be installed at a lower height. Note: Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour. Mantel Leg Clearances E Combustible mantel leg clearances as per diagram below: Clearances are from the fi nished edge of the unit or an installed front. Clearance: Dimension Measured From: A: Mantel Height 7 (178mm) Minimum (Additional on this page) B: Sidewall 6 (152mm) Side of installed front Sidewall: Barcelona Only 8 (23mm) Approved for single sidewall only C: Ceiling 32 (813mm) Top of installed unit D: Mantel Depth 12 (35mm) Maximum (Additional on this page) E: Alcove Width 48 (1219mm) Sidewall to Sidewall (Minimum) F: Alcove Depth 36 (914mm) Front to back wall (Maximum) Top of Hearth must not be higher than the base of the fi rebox. Maximum 1-1/2 projection at 2 minimum clearance. P36 - P36D 2" Mantel leg 6" Side Wall 8" Single Sidewall when using the Barcelona Surrround 1-1/2" Mantel leg 5" Allowable mantel leg projection. 3" 36 June 27 Regency Product Specifications Book

FPI Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P36 / P36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram. FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the P36 / P36D using a flexible vent. FPI Kit # Length Contains: #946-515 4 Feet 1) 6-5/8 fl exible liner (Kit length) 2) 4 fl exible liner (Kit length) 3) spring spacers (3) 4) thimble (2) #946-516 1 Feet 5) AstroCap termination cap (1) 6) screws (12) 7) tube of Mill Pac (1) 8) plated screws (8) 9) S.S. screws #8 x 1-1/2 drill point, (4) 4" (12mm) dia. flue pipe 6-7/8" (173mm) dia. Flue pipe Wall Thimble (2 pc) spring spacer Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Horizontal sections must be supported every 3 feet. AstroCap Termination Cap Part #946-523/P Alternate Horizontal Termination Caps Snorkel Terminations Snorkel Terminations: For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Snorkel Terminations and the Riser Vent are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down. Below Grade Snorkel Installation (Dura-Vent Only) If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure. Alternate: Horizontal Riser Vent Terminal Part# 64-53/P If required by the external termination location the listed alternate termination caps may be used. (Refer to Page 11) June 27 Regency Product Specifications Book 37

Rigid Pipe Venting Horizontal or Vertical Terminations Vertical Terminal Storm Collar Part # 953 Flashing 943 or 943S Ceiling Firestop (Part # 963) Pipe Length o 9 Elbow Pipe Length Vinyl Siding Standoff (Optional) Part #95 Adj.Pipe Length 11" - 14-5/8" Wall Thimble Part # 942 Horizontal Termination Cap (Part #946-523/P) Alternate Horizontal Termination Caps 4 38 36 34 32 3 2 4 6 8 1 12 14 Maximum: 4 ft. (12.2m) Rigid Pipe Adapter (Part# 51-994) 28 26 Alternate: Horizontal Riser Vent Terminal Part# 64-53/P 24 22 If required by the external termination location the listed alternate termination caps may be used. (Refer to Page 11) Venting Arrangements - Vertical Terminations Rigid Pipe System (Propane & Natural Gas) Vertical Height (Feet) 2 18 16 14 Maximum: 27 ft. (8.2m) The P36 / P36D is approved for a maximum 4 ft. straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas. 12 The lightly shaded area,, in the diagram shows allowable venting confi gurations with a maximum of two 45 elbows allowed. The darker shaded area,, in the diagram shows allowable venting confi gurations using two 9 elbows. Vent must be supported at offsets. Horizontal sections must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall. Maintain clearances to combustible materials. Minimum of 1 pipe section between elbows. 1 8 6 4 Minimum 8 6 (2.6m) Minimum 1 6 (3.2m) Note: Must use optional flue adapter when using Rigid Pipe (Part # 51-994). 2 Minimum 12 (35mm) Max. 1 (3m)(centerline to centerline) 38 June 27 Regency Product Specifications Book

Vertical Venting with Two (2) 9 Elbows Two 45 elbows = One 9 elbow Option V H V+ V1 Maximum total pipe: length, of A) Min. 2 Max. 1 Min. all sections, must not exceed 3 feet. B) 1 Min. 4 Max. 3 Min. Total horizontal sections must C) 2 Min. 5 Max. 4 Min. not exceed 8 feet. Minimum of 1 foot between D) 3 Min. 6 Max. 5 Min. 9 elbows is required. E) 4 Min. 7 Max. 6 Min. F) 5 Min. 8 Max. 7 Min. Vertical Venting with Three (3) 9 Elbows Two 45 elbows = One 9 elbow Option V H + H1 V+ V1 Maximum total pipe: length, of A) Min. 2 Max. 2 Min. all sections, must not exceed 3 feet. B) 1 Min. 2 Max. 3 Min. Total horizontal sections must C) 2 Min. 3 Max. 4 Min. not exceed 8 feet. Minimum of 1 foot between D) 3 Min. 4 Max. 6 Min. 9 elbows is required. E) 4 Min. 5 Max. 7 Min. F) 5 Min. 6 Max. 8 Min. G) 6 Min. 7 Max. 9 Min. H) 7 Min. 8 Max. 1 Min. June 27 Regency Product Specifications Book 39

Venting Arrangements - Horizontal Terminations This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 9º elbow (two 45º elbows equal one 9º elbow). The lightly shaded area,, in the diagram shows allowable combinations when installing a P36 The darker shaded area,, in the diagram shows additional allowable combinations when installing a P36D. Note: Must use optional flue adapter (Part # 51-994) when using Rigid Pipe. Maintain clearances to combustibles. Horizontal vent must be supported every 3 feet. Firestops are required at each fl oor level and whenever passing through a wall. A vent guard may be required as per local codes, refer to page 11 for Exterior Vent Termination Locations. Note: FPI Direct Vent System (Flex) is only approved for horizontal terminations. Horizontal (Feet) 2 4 6 8 1 12 14 16 18 2 18 16 14 Vertical Height (Feet) 12 1 8 P36D ONLY 6 4 2 4-1/2" (129mm) Minimum Height Requirement Please refer to Page 11 (Exterior Vent Terminations) for additional guidelines on vent locations. 4 June 27 Regency Product Specifications Book

Horizontal Venting with Two (2) 9 Elbows Two 45 elbows = One 9 elbow Option V H+ H1 Maximum total pipe: length, of A) Min. 2 Max. all sections, must not exceed 3 feet. B) 1 Min. 3 Max. Total horizontal sections must C) 2 Min. 4 Max. not exceed 8 feet. Minimum of 1 foot between D) 3 Min. 5 Max. 9 elbows is required. E) 4 Min. 6 Max. F) 5 Min. 7 Max. F) 6 Min. 8 Max. Horizontal Venting with Three (3) 9 Elbows Two 45 elbows = One 9 elbow Option V H V+ V1 H + H1 Maximum total A) Min. 1 Max. 1 Min. 2 Max. pipe: length, of all sections, must B) 1 Min. 2 Max. 3 Min. 3 Max. not exceed 3 C) 2 Min. 2 Max. 5 Min. 4 Max. feet. Total horizontal D) 3 Min. 2 Max. 7 Min. 5 Max. sections must not E) 4 Min. 3 Max. 9 Min. 6 Max. exceed 8 feet. Minimum of 1 F) 5 Min. 4 Max. 1 Min. 7 Max. foot between 9 elbows is G) 6 Min. 5 Max. 11 Min. 8 Max. required. H) 7 Min. 6 Max. 12 Min. 9 Max. June 27 Regency Product Specifications Book 41

4-1/2 Vertical termination with co-linear flex system The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance. Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending. The Air Intake pipe must be attached to the inlet air collar of the termination cap. This appliance is designed to be attached to two 3 (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements for minimum and maximum heights. Required Parts: Part # Description 946-529 Co-linear DV Vertical Termination Cap 948-35 3 Flex - 35 ft. 946-563 Coaxial to Co-linear Adapter Kit which contains the following: Co-linear Flex Adapter Pipe Inner Pipe Adapter 51-994 Flue Adapter 945 45º Elbow Alternate Approved Caps 98 Vertical Termination Cap 991 High Wind Cap 923GK 3 Co-linear Adapter with fl ashing Co-linear DV Vertical Termination Cap # 946-529 3 A maximum of two certified joiner kits may be used per length. #948-35 (35 ft) Flex Liner Exhaust Flue Vertical Height (feet) 3' Max. Pipe with Kit# 946-563 Pipe Length Rigid Pipe Adapter # 51-994 9 Degree Elbow Inner Pipe Adapter with Kit# 946-563 Air Intake Co-Linear Flex Adapter with Kit# 946-563 2 max. 8' Min. Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. Please refer to Page 11 (Exterior Vent Terminations) for additional guidelines on vent locations. 42 June 27 Regency Product Specifications Book