INSTALLATION INSTRUCTIONS AS 2.1 CORRUGATED ETERNIT ROOF

Similar documents
TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

Conergy SolarFamulus II

TRAPEZOIDAL SHEET METAL RAIL

ST-AK 1/12. Photovoltaic Mounting Systems. Assembly Instructions. Mounting system for roofing with trapezoidal sheet metal

Mounting instructions. novotegra for trapezoidal metal - roof parallel

Mounting systems for solar technology

On-roof system Tau Installation manual

installation instructions English

Mounting instructions

PITCHED ROOF. Photovoltaic Mounting Systems. Assembly Instructions. for roofing tiles, plain tiles and slate

00MK-MA0160-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Little Plan and Little Plan Light systems, for corrugated sheet metal roof

INSTALLATION MANUAL AEROCOMPACT+ east/west

Radiant PV-RoofTopRac System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT

Mounting systems for solar technology

INSTALLATION INSTRUCTION AEROCOMPACT S5

Installation Instruction for DMEGC Photovoltaic Module

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR

Mounting System MCG 3.0 Membrane-Connected Glass. System description

INSTALLATION INSTRUCTIONS ENGLISH

Mounting System MCG 3.0 Membrane-Connected Glass. System description

HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION

YINGLI SOLAR TWINMAX MODULES Installation and User Manual

Radiant PV-Solar Tripod System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT

HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION

Installation instructions

installation instructions English

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev

Mounting System MCG 1.1 Membrane-Connected Glass. System description

Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2

Mounting instructions. novotegra for folded seam roof

ifix INSTALLATION MANUAL PV flat roof installation system Version

Installation instructions

Mounting systems for solar technology

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

Mounting systems for solar technology

SoliTek PV Modules INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS TRI-STAND East-West. energy for a better world. Mounting system for PV systems with east-west orientation on flat roofs

Mounting systems for solar technology

Tindo Karra. Installation and Specifications Manual. Introduction

INSTALLATION INSTRUCTIONS ENGLISH

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. SpeedRail System.

LEICHTmount TM EU 2.0 S 5 /10 /15

a-si/μcsi Tandem Module Installation Manual Macsun Solar Energy Technology Co., Limited Applied to MS-SDXX

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM

PRR. Flush Mount Racking System. Installation Manual

Flat roof for the loading-optimized elevation (adhesive system)

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

MOUNTING SYSTEM FOR SOLAR POWER SYSTEMS PLANNING AND DESIGN

Infix ProLine Installation manual

Mounting systems for solar technology

MRac Tile Roof Installation Guide

Installers Guide. Item

PV-ezRack Trapezoidal Installation Guide V2.0

Installation Guide EcoFoot5D High Density 5-Degree Ballasted Racking System Document No. ES10560

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

User instructions for photovoltaic modules 60Pxxx-V 60Mxxx-V 72Pxxx-V 72Mxxx-V 60Pxxx 60Mxxx 72Pxxx 72Mxxx

Aurora Genmounts Install LT Installation Manual

MOUNTING SYSTEMS APPLICATIONS OVERVIEW

Installation and Users Manual

PV-ezRack SolarMatrix Pro

IEC Installation Guide for SERAPHIM Photovoltaic Module

EJOT Solar Fastenings. Installation Manual

EASY ROOF FLAT PV FIXING SYSTEM FOR FLAT ROOF

SystemFS. SystemFS product sheet. Generation 6

ifix Installation Manual PV flat roof mounting system english Version May 1st, 2018

mounting systems applications overview

GROUND MOUNT INSTALLATION MANUAL

Installation and Operation Manual

SystemFS. SystemFS product sheet. Generation 6

KRIWAN Wind Sensors. Operating Instructions Accessories and Application Information

SECURE. UNIVERSAL. MOUNTING. Tilt Kit Installation Manual

PV-ezRack SolarTerrace III-A Installation Guide V1.2

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Installation manual ValkTriple EN-UK

Architectural Roof and Wall Products Guide Specifications

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

USER MANUAL FOR MOLDS MOLDS FOR THE PRODUCTION OF CONCRETE ELEMENTS

moment Engineering + Design Warwick Avenue, Suite #C5 Fairfax, VA Phone: Web:

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. S-Dome 2.0 System.

Festoon Manual Heavy Duty C-Track

MANUAL. portrait set-up. landscape set-up. ClickFit Evo mounting system for sloping roofs with roof tiles for solar panels

TallSlateTM Grandee Installation Manual

ValkPitched - Bitumen

SolarStyl BIPV New Building Integrated Photovoltaic System August V13 Page 0

INTERSOL MOUNTING SYSTEMS

Installation Instruction photovoltaic modules E-PV 250W on the flat roof or fundation 10/2013 Get acquainted before the installation.

PV-ezRack SolarTerrace II

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. D-Dome System.

Industrial flue gas probes. Instruction manual

2019 V1 SERAPHIM DG PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG

Benefits in Speed and Logistics using the RL System. snapnrack.com

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. D-Dome 2.0 System.

Platform stair lift PLG7

Solcellspaket - Poly (4.2 kwp Jinko 265W Poly) System Plan. Created with Solar-Planit by Mikael Johansson Futura Energi AB in Simrishamn.

ValkPitched - Clamp. Installation manual. Van der Valk Solar Systems. Solar Mounting Systems. Version 17 EN

Installation instructions for. Wall Mounting Frame C M298 - M311 - M313 - M314 - M316. Version: 1.0 Date:

PRB. Flush Mount Racking System. Installation Manual

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. S-Dome System.

Transcription:

INSTALLATION INSTRUCTIONS AS 2.1 CORRUGATED ETERNIT ROOF

ALUMERO GROUP YOUR BIG ADVANTAGE! + in-house consulting and design office + competent and reliable staff + aluminium mounting profiles and custom-drawn special profiles + professional machining + overall production, up to the complete assembly from a single source + mounting systems for outdoor and rooftop application + clamp techniques, laminate and module clamp solutions + customized solutions - from design to fabrication and implementation + short response times, fast and flexible processing times + on time and flexible delivery and logistics concepts

Please read the safety instructions carefully before beginning installation work. Corrugated eternit roofs are usually implemented as slightly sloping purlin roofs. You should provide a point of anchorage to the substructure at every purlin. Each of these anchoring points is always on a wave crest of the corrugated eternit panel. Generally, the spacing is approximately 1,15 m. As the corrugation runs at 90 to the purlins, you have to insert a hanger bolt at every point of intersection between purlin and wave. The mounting profiles are normally mounted from the ridge to the eaves. The modules are thus installed landscape. This does not apply to rafter roofs, as the rafters do not always run beneath a wave. In such cases, you should add an auxiliary rafter to the side of the existing rafter in the proper manner, so as to be able to position the hanger bolt. You can benefit from ALUMERO s professional and comprehensive consulting service for any further questions. Our experienced engineers and technicians would be glad to be of assistance. The following torques are to be adhered to: 15 Nm M8 (A2-70 or A4-70) 30 Nm M10 (A2-70 or A4-70) Required tools: Electric screwdriver Hexagonal socket wrench (Allen key) 6mm ring / open-ended wrenches (openended spanners) 15mm, 17mm 3

Fig. A Fig. B 1 Fig. A: At the fastening point, drill a hole into the corrugated eternit roofing and the wooden structure beneath. Make sure that you always select a wave crest as the installation point. For the M10 hanger bolt, you require a ø 7 mm drill bit for the wooden structure, and ø 13 mm for the eternit panel. For the M12 hanger bolt, use a ø 8 mm drill bit for the wooden structure, and ø 15 mm for the eternit panel. Then screw in the full threaded length of the hanger bolt. Please ensure that you adhere to the minimum anchoring depth of 8 cm (M10) or 10 cm (M12) respectively. For anchoring to the support structure, you should provide a distance between the hanger bolt and the edge of the purlin of at least 3 cm (M10) or 3,6 cm (M12) respectively. Once you have placed the hanger bolt, affix the EPDM sealing over the drilled hole with an M10/M12 fixing nut. Then, install the fast mounting plate between 2 additional nuts in such a manner, that a plane bearing surface for the mounting profiles is created, on which the mounting profiles can be placed stressless. Now fix the fast mounting plate by adjusting the two nuts at the head of the hanger bolt connection. Hint: It is strictly forbidden to install a PV system on an asbestos cement roof. 4 2 Fig. B: Insert the mounting profile in the preassembled fast mounting plate on the hanger bolt and align the mounting profiles. Afterwards tighten the allen screw to fix the connection. Please note:» Each mounting profile has to be fixed on minimum two roof fixation elements (e.g. hanger bolt).» The maximum mounting profile length should not exceed 15,0 m.» After 15,0 m, install an expansion joint of at least 5 cm.» The mounting profiles should have a maximum cantilever of 30 cm beyond the last roof fixation element.

3 Fig. C: To connect the mounting profiles insert the profile connector into the profiles. The mounting profiles should not be plugged together before they are at the installation site (e.g. the roof). Fig. C Please note: The connected mounting profiles should not be transported in vertical. 4 Fig. D Fig. E: End caps can be applied to the mounting profiles as optical finishing. Press them by hand in the end of the mounting profile at the required profile. Fig. E 5

5 Additional information for double-layer systems: Mount the basis layer profiles according to the before mentioned installation steps on the roof fixation elements (e.g. hanger bolts). The orientation of the profiles could be horizontal (parallel to the ridge) as well as vertical (parallel to the rafter). Fig. F: Screw in the cross connector in the upper slot of the basis layer profile and screw in also the allen screw with the threaded plate in the upper slot. Fig. G: Align the cross connector and tighten the allen screw to fix it. ) ĀF ) ĀG 6 Fig. H: Insert the mounting profile in the cross connector and align the mounting profiles. Afterwards tighten the allen screw to fix the connection. Please note: The screw of the cross connector to fix the mounting profile should always be aligned in direction to the top (in direction to the ridge). ) ĀH 6

7 8 Fig. I: Place the first module with an edge distance of miniumum 3 cm on the mounting profiles. Insert the preassembled end clamps and tighten the allen screws. Fig. I Fig. J: For the fixation of the module on the other side, place another module on the mounting profiles beside the first and insert the preassembled middle clamps in between of the two modules. Align the modules and tighten the allen screws to fix them. Proceed in this manner until you have placed the last module of the row. Fix it with end clamps as described before. Fig. J Please note: The mounting areas prescribed by the manufacturer of your module can be found in the module data sheet. 7

PLEASE PAY ATTENTION TO THE FOLLOWING NOTES! We recommend, that you read the following information carefully, as it is of great importance when handling the product. Please also inform yourself of the safety regulations which pertain to the other system components. 8

SAFETY INFORMATION AND WARNINGS You should adhere to these instructions precisely, whenever working on the PV system. Installation, commissioning, maintenance and repairs may only be performed by appropriately qualified and authorized persons. Please observe the applicable regulations and safety instructions. You must observe the following accident prevention regulations:» BGV A 1 General regulations» BGV A 2 Electrical systems and equipment» BGV C 22 Construction work (personal fall protection equipment)» The trade association health and safety at work rules (BGR 203 Working on roofs) and DIN EN 516 Equipment for accessing roofs» The trade association regulations regarding work clothing and work safety You must adhere to the following DIN standards:» DIN 18299 General rules for all kinds of building works» DIN 18338 Roof covering and roof sealing works» DIN 18360 Metal construction and locksmith works» DIN 4102 Fire behaviour of building materials and building components Only authorized personnel may carry out work on systems of Alumero Systematic Solutions GmbH. The operator of the system has the following safety-related obligations:» Performance of regular annual maintenance work, e.g. inspection of cabling, bolt connections, and the roof skin.» The mounting system may only be installed by persons with suitable qualifications, technical skills, and knowledge of the fundamentals of mechanics.» It must be ensured that the assigned persons can assess the work allocated to them, and can identify possible dangers.» The installation instructions are part of the product, and must be available during installation.» It must be guaranteed that the installation instructions, and particularly the safety instructions, have been read and understood by the assigned personnel before installation.» The trade association regulations, the local work safety regulations and the technical regulations must be adhered to.» Suitable hoisting equipment and ladders are to be used for the installation work. No leaning ladders may be used.» It is necessary to arrange for a qualified construction engineer to assess the building s existing static loading characteristics with regard to the additional loads of a PV system.» Any general load reduction measures specified by Alumero Systematic Solutions GmbH (e.g. the need to clear snow, so as to limit the snow load) are to be observed. 9

WARRANTY / PRODUCT LIABILITY (EXCLUSION) The dimensioning information included in these instructions merely represents information gathered in practice. Binding structural calculations for the mounting system can be calculated with the software Alumero.Solar.Pro.Tool. As the installation company, you are responsible for correct execution of installation work. Alumero Systematic Solutions GmbH is not liable for the dimensioning information included in commercial system proposals. As installer, you are responsible for the mechanical durability of the interface connections mounted on the building s structure. In particular, this includes that these are leak-tight. The components of Alumero Systematic Solutions GmbH are designed for the expected loads and they are in compliance with the effective state of the art. For this purpose, you have to specify in writing all general technical framework conditions in the project documentation form (information on the support structure, snow load zone, building heights, wind loads, etc. ) when requesting information/ordering from Alumero Systematic Solutions GmbH. Alumero Systematic Solutions GmbH is not liable for incorrect handling of the installed parts. Any use close to the sea is excluded because of the increased risk of corrosion. NOTES ON ELECTRICAL INSTALLATION WORK Only if you are a qualified electrician, you may perform any electrical work. The applicable DIN standards, VDE regulations, VDEW guidelines, VDN guidelines, accident prevention regulations and the regulations of the local utility company are authoritative in this regard.» DIN VDE 0100 (Installation of high voltage systems with nominal voltages up to 1000 V)» VDEW guideline for parallel operation of domestic power-generation systems with the low voltage grid of the utility company» VDI 6012 sheet 2, guideline for decentralized energy systems in buildings: Photovoltaics» Leaflet for VDEW guideline Domestic power-generation systems on the low voltage grid» VDN guideline Domestic power-generation systems on the low voltage grid» DIN/VDEregulations, DIN/VDE 0100 Installing high voltage systems with grid voltages up to 1000 V, in particular VDE 0100, Part 410, Protection against direct and indirect contact (Direct current > 120 V, < 1000 V direct current) and the Accident prevention regulations of the commercial trade associations VBG4 Electrical systems and equipment» DIN VDE 0100-540 Selection and installation Earthing, protective conductors and equipotential bonding conductors» DIN 57185 VDE 0185 Installation of a lightning protection system and VDS 2010 Alumero Systematic Solutions GmbH grants a 2-year product guarantee on the service life and stability of the mounting systems, subject to correct handling, dimensioning in accordance with the static loading conditions, normal environmental conditions, and normal ambient conditions. This applies within the generally prevalent weather conditions and environmental conditions. Material and workmanship guarantee: Alumero Systematic Solutions GmbH grants a 10-year material and workmanship guarantee on the materials used. Consult the specific guarantee conditions for more detailed information. 10

IMPORTANT WARNINGS Solar modules generate electricity as soon as they are exposed to light. There is always a voltage present. The fully insulated plug contacts provide a level of contact protection but when dealing with solar modules, the following points must be observed:» Do not insert electrically conductive parts into the plugs or sockets.» Do not install solar modules and wiring using wet plugs or sockets.» Perform any work on cabling with extreme caution.» Do not carry out any electrical installation work in damp conditions.» Also with low lighting, very high direct voltages arise at the series connection of modules, which can be life-threatening upon contact. In particular, note the possibility of secondary damage in the event of electric shocks. Even when the unit is switched off, high contact voltages may still be present inside the inverter:» Be particularly careful when working on the inverter and the cables.» After switching off the inverter, it is essential to wait for the time interval specified by the manufacturer before beginning any further work to allow the high voltage components to discharge.» Please also observe the installation guidelines provided by the inverter manufacturer.» Check to see if all screw connections are tightened correctly.» Adhere to the specified torques.» Regardeless a verifiable static equilibrium, it is your responsibility to ensure before every installation that the product meets the local static requirements pursuant to DIN 1055.» DIN standard 1055 Actions on structures Part 1: Densities and weights of building materials, structural elements, stored materials Part 4: Wind loads Part 5: Snow load and ice load Part 100: Basis of structural design Safety concept and design rules» The mounting system is designed in accordance with DIN 4113 Aluminum constructions under predominantly static loading and DIN 18800 Steel structures; design and construction or the corresponding Eurocode EC1, EC3, EC9.» Ensure that the substructure, support structure and other affected layers (such as an insulation layer) have adequate load capacity (based on dimensions, condition and suitable material properties).» Make sure that the rainwater runoff is not impeded.» Pay attention to the physical construction aspects (e.g. possible condensation problems caused by penetration of insulating layers). When breaking a connected string of modules (e.g. when disconnecting the DC line from the inverter under load), a lethally strong electric arc can occur:» Never disconnect the solar generator from the inverter as long as it is connected to the mains. STANDARDS AND GUIDELINES All of the standards and guidelines listed here are published for and applicable to Germany. They are to be complied with in their current version. Outside of Germany, please also observe the corresponding national standards and guidelines. NOTES ON THE INSTALLATION OF MOUNTING SYSTEMS For installation in roof areas, you must adhere to the currently applicable structural engineering regulations, especially the requirements set out in the DIN standards and in the Regulations of the German Roofing Industry ( Regelwerk des Deutschen Dachdeckerhandwerks ). PRODUCT LIABILITY The technical documentation constitutes part of the product. Alumero Systematic Solutions GmbH is not liable for damages caused by noncompliance with the installation instructions, particularly the safety instructions, or caused by inappropriate use of the products. 11

CONGRATULATIONS, WELL DONE! WWW.ALUMERO.AT Alumero Systematic Solutions GmbH Sonnenweg 1-2 5164 Seeham - Österreich T +43 6217 / 68 41-0 F +43 6217 / 68 41-41 alumero@alumero.at www.alumero.at January 2013 CONTACT HEADQUARTER