FATIGUE AND CORROSION FATIGUE OF 8090 Al-Li-Cu-Mg ALLOY

Similar documents
Effects of temperature on monotonic and fatigue properties of carbon fibre epoxy cross ply laminates

ATOM PROBE ANALYSIS OF β PRECIPITATION IN A MODEL IRON-BASED Fe-Ni-Al-Mo SUPERALLOY

STRAIN RATE DEPENDENCE ON MECHANICAL PROPERTIES IN SOME COMMERCIAL ALUMINUM ALLOYS

High Purity Chromium Metal Oxygen Distribution (Determined by XPS and EPMA)

Effect of the Hydrogen Induced Degradation of Steel on the Internal Friction Spectra

Fatigue of High Purity Copper Wire

Ductility of Ultra High Purity Copper

Powder metallurgical processing of a SiC particle reinforced Al-6wt.%Fe alloy

STRUCTURE AND PROPERTIES OF RAPIDLY SOLIDIFIED ALUMINUM-LITHIUM ALLOYS

Heat line formation during roll-casting of aluminium alloys at thin gauges

Structure/property relationships in HSLA steel with low carbon and manganese and increased silicon content

Pressure effects on the solubility and crystal growth of α-quartz

KPY 12 - A PRESSURE TRANSDUCER SUITABLE FOR LOW TEMPERATURE USE

The Effect of Nitrogen on Martensite Formation in a Cr-Mn-Ni Stainless Steel

Selecting the components of composites

PROPERTIES OF Fe-Cr-Ni-Mn-Si (-Co) SHAPE MEMORY ALLOYS

A new method of making metal matrix fibre reinforced materials

Grain growth and Ostwald ripening in chromia-doped uranium dioxide

FATIGUE CRACK PROPAGATION BEHAVIOUR OF THE Al-Li ALLOY 8090 COMPARED TO 2024

CVD COATING OF CERAMIC LAYERS ON CERAMIC CUTTING TOOL MATERIALS

Physical properties of epoxy and free volume evaluated by positron annihilation spectroscopy

HYDROGEN SEGREGATION AND DIFFUSION AT GRAIN BOUNDARIES

DIFFICULTIES IN GRAIN REFINING ALUMINUM LITHIUM ALLOYS USING COMMERCIAL Al-Ti AND Al-Ti-Bor MASTER ALLOYS

ATOM-PROBE ANALYSIS OF ZIRCALOY

CHEMICAL VAPOR DEPOSITION OF IR-TRANSMITTING ZINC SULPHIDE

LASER PROCESSING OF METAL-CERAMIC COMPOSITE MULTILAYERS

RECYCLING OF ALUMINIUM-LITHIUM PROCESS SCRAP

APFIM AND FEM STUDY OF Mo-La ALLOY WIRE

DISLOCATION RELAXATION IN HIGH PURITY POLYCRYSTALLINE ALUMINUM AT MEGAHERTZ FREQUENCIES

Secondary recrystallization of oxide dispersion strengthened ferritic alloys

Laser cladding of copper base alloys onto Al Si7 Mg0.3

Strength of 10CR-N martensitic steels

Mechanism of two Way Shape Memory Effect Obtained by Stabilised Stress Induced Martensite

Simulation of Dislocation Dynamics in FCC Metals

ELLIPSOMETRY OF NICKEL-OXIDES AND -HYDROXIDES IN ALKALINE ELECTROLYTE

BALLISTIC PERFORATION OF POLYCARBONATE SHEET AND ITS HIGH STRAIN RATE RESPONSE

Computerized simulation of thermal behaviour during forging sequences

Strain hardening of aluminium alloy 3004 in the deep drawing and ironing processes

MECHANICAL AND ELECTRICAL PROPERTIES OF A NiTi SHAPE MEMORY ALLOY

Non destructive observation by X-ray diffraction on a berlinite crystal

THE INTERPRETATION OF ELECTRON DIFFRACTION PATTERNS FROM Ni-Al MARTENSITE

EFFECT OF STRESS AND STRAIN ON MARTENSITIC TRANSFORMATION IN A Fe-Ni-Mo-C ALLOY WITH A HIGH Ms TEMPERATURE

Characterising the impact of surface integrity on the fatigue behaviour of a shot-peened connecting rod

Precipitation mechanisms and subsequent hardening kinetics in the β-cez alloy

INTERDIFFUSION OF Au/Ni/Cr ON SILICON SUBSTRATE

Real-Time Control of Resonance in Smart Shape-Memory Alloy Hybrid Laminates

HIGH DAMPING IN GREY CAST IRON

Drum- and -Disc-Engine with Shape Memory Wires

Bonding of aluminium matrix composites for application in the transport industry

THE EFFECT OF DYNAMIC LOADING ON THE STRUCTURE AND PROPERTIES OF 18G2A AND 14HNMBCu STEELS

STRUCTURAL RELAXATION AND CRYSTALLIZATION OF FeB AND NiP METALLIC GLASSES FOLLOWED BY INTERNAL FRICTION AND MODULUS MEASUREMENTS

Densification superficielle de matériaux poreux par choc laser

Magnetic pulse deformation of tubes made of partially polymerised carbon fibre reinforced plastic

PHOTOCONDUCTIVITY IN a-si : H AND a-sixc1-x : H, CORRELATION WITH PHOTOLUMINESCENCE RESULTS

Safety Information Bulletin Airworthiness SIB No.: R1 Issued: 13 September 2018

THERMAL PULSE ANNEALING OF TITANIUM AND TANTALUM SILICIDES

Comparison of fracture toughness measuring methods applied on silicon nitride ceramics

High temperature mechanical properties of AlMgZn alloys with copper and zirconium additions

EPITAXIAL GROWTH AND SOME PROPERTIES OF SAMARIUM CRYSTALS ON TUNGSTEN

ELECTRONIC PROPERTIES OF SILICON INTERFACES PREPARED BY DIRECT BONDING

Continuous Casting of Aluminum and Copper Clad Ingots under Electromagnetic Fields

The Effect of Stress Ageing on the Properties of Shape Memory Alloys

CHARACTERIZATION OF POLYCRYSTALLINE SILICON BY EBIC

NANOINDENTATION-INDUCED PHASE TRANSFORMATION IN SILICON

HYSTERETIC DAMPERS FOR PROTECTING STRUCTURES DURING EARTHQUAKES

Incoloy alloy MA956. Strain rate and temperature effects on the microstructure and ductility

Electrodeposition of Thin Film Cu-Zn Shape Memory Alloys

Interaction between mechanosorptive and viscoelastic response of wood at high humidity level

CASTABILITY OF Al-Li-Mg AND Al-Li-Cu-Mg ALLOYS

Plasticity criterion for hot forming of Aluminum-Lithium alloy

The Effect of Magnetic Field on Metal Anodizing Behaviour

THE EFFECT OF SILICA ON THE MICROSTRUCTURE OF MnZn FERRITES

CHARACTERISTICS OF FERRITE ELECTRODES

Stabilization of Austenite Associated with Prior Formation of Martensite

RESPONSE OF AISI TYPE 316 STAINLESS STEEL TO INTERRUPTED QUASI-STATIC TO IMPACT TENSION AT ELEVATED TEMPERATURES

BRIDGMAN GROWTH AND PROPERTIES OF LuAlO3-Nd3+ LASER CRYSTALS

POSSIBILITIES AND LIMITATIONS OF LASER SURFACE ALLOYING BY MELTING OF PREDEPOSITED LAYERS

Evolution of the porous volume during the aerogel-glass transformation

On the relation between the Luders deformation and grain boundary structure in aluminium alloy

Influence of cold rolling and fatigue on the residual stress state of a metal matrix composite

FATIGUE BEHAVIOR OF PEARLITIC S.G. CAST IRONS AFTER LASER SURFACE HEAT TREATMENTS

Finite Element Model of Gear Induction Hardening

Atom-probe study Ti Al based alloy

Time decay of the excited states of Eu+2 in europium-doped LMA

Progress of some techniques on electromagnetic metallurgy

THE QUANTITATIVE ANALYSIS OF COPPER IN IRON BASED ALLOYS

SURFACE ACOUSTIC WAVE ATTENUATION IN THIN FERROMAGNETIC FILMS

Cr3+-SENSITIZATION OF THE 3µm Er3+: YAG LASER

Competition between surface defects and residual stresses on fatigue behaviour of shot peened forged components

THE EFFECT OF MANGANESE ON INTERGRANULAR FRACTURE IN LOW ALLOY STEELS

IDENTIFICATION OF AN ORDERED HEXAGONAL BeFe PHASE

ON STRAIN RATE SENSITIVITY OF BETA-TITANIUM ALLOYS

LONG-RANGE ICOSOHEDRAL SYMMETRY IN A METALLIC PHASE OBSERVED BY FIELD ION MICROSCOPY

Impact of cutting fluids on surface topography and integrity in flat grinding

The microstructure evolution of Fe-Si alloys solidified in a high static magnetic field

SPECTROSCOPIC PROPERTIES AND OPERATION OF PULSED HOLMIUM LASER

LOW CARBON AND SILICON STEEL QUADRUPOLE MAGNETS

Electrical properties of interlevel deposited oxides related to polysilicon preparation

PARTIAL HYSTERESIS CYCLES IN SHAPE-MEMORY ALLOYS : EXPERIMENTS AND MODELLING

Metal-ceramic joining by laser

Transcription:

FTIGUE ND CORROSION FTIGUE OF 8090 l-li-cu-mg LLOY F. Haddleton, S. Murphy, T. Griffin To cite this version: F. Haddleton, S. Murphy, T. Griffin. FTIGUE ND CORROSION FTIGUE OF 8090 l-li-cu-mg LLOY. Journal de Physique Colloques, 1987, 48 (C3), pp.c3-809-c3-815. <10.1051/jphyscol:1987395>. <jpa-00226627> HL Id: jpa-00226627 https://hal.archives-ouvertes.fr/jpa-00226627 Submitted on 1 Jan 1987 HL is a multi-disciplinary open access archive for the deposit and dissemination of scientific research documents, whether they are published or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers. L archive ouverte pluridisciplinaire HL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

JOURNL DE PHYSIQUE Colloque C3, supplbment au n09, Tome 48, septembre 1987 FTIGUE ND CORROSION FTIGUE OF 8090 l-li-cu-mg LLOY F.L. HDDLETON, S. MURPHY and T.J. GRIFFIN" Department of Mechanical and Production Engineering, ston University, ston Triangle, Gosta Green, GB-Birmingham B4 7ET Great-Bri tain "~unlop Ltd., viation Division, GB-Coventry, Great-Britain &$@&t The fatigue - resistance of metals can be ~rofoundlv affected bv the environmental reactions that change - crack initiation and propagation processes. These corrosion fatigue processes can occur in high strength aluminium alloys in aircraft, which frequently encounter salt spray and high humidity environments. For this reason, the fatigue behaviour of 8090-T6 alloy in the form of 25mm thick plate has been investigated in both air and an aerated 2.5% NaCl solution. Results are compared to a conventional high strength aluminium alloy, 2014-T6. Fatigue crack initiation and propagation data are presented for different crack orientations and mean stress levels. The slightly lower fatigue strength of 8090-T6 in air is attributed to earlier crack initiation. The fatigue crack propagation behaviour of 8090-T6 is shown to be superior to that of 2014-T6 at low to intermediate levels of K, under both environmental conditions. The mechanisms associated with fatigue crack initiation and propagation, and environmental effects, are discussed. e - Introduction The replacement of conventional high strength aluminium alloys in airframe applications with recently developed aluminium-lithium based alloys has been shown to offer weight savings, due to the increase in specific properties that result from the decrease in density and increase in modulus (1). Work has concentrated on the development of alloys to meet the property levels of conventional high strength aluminium alloys. series of three l-li-cu-mg alloys has been developed to meet these requirements (2,3). Improved alloy chemistry and manufacturing techniques in the last few years have made this possible. The combination of these properties and the resultant 10% lower density and 10% higher modulus than conventional aluminium alloys make these I-Li-Cu-Mg alloys attractive for airframe applications. The fatigue performances of aluminium-lithium based alloys have been shown to be superior to conventional alloys, with crack growth resistance far better at low levels of K (2,4). lthough fatigue, corrosion and SCC properties of l-li-cu-mg alloys have been investigated (4,5,6), little attention has been given to their corrosion fatigue properties The aim of this work was to investigate the fatigue and corrosion fatigue properties of one of these alloys, and compare with a conventional 2XXX series aluminium alloy. E The material under investigation was alloy 8090 (2,3), in the form of 25mm thick rolled plate supplied by lcan International Ltd. and RE. The chemical composition of the alloy was (wt.%): 2.50Li - 1.19Cu - 0.67Mg - O.1OZr. The material was supplied in the T8 condition, where a 2.5% cold stretch was given in between solution treatment and artificial ageing. However, for the applications that the authors are concerned with a stretching treatment was impracticable. further heat treatment was therefore carried out to provide a T6 temper, a solution treated and artificially aged condition. Solution heat treatment was carried out at 530 C for one hour, followed by a cold water quench. The ageing treatment was carried out at 190 C for 24 hours. Comparative tests were performed on BS L168, conforming to 2014-T6. rticle published online by EDP Sciences and available at http://dx.doi.org/10.1051/jphyscol:1987395

C3-8 10 JOURNL DE PHYSIQUE Tensile tests were performed on 2014-T6 and 8090 in both the T6 and T8 conditions in order to quantify the reduction in tensile properties resulting from the lack of a cold stretch. Tests were carried out in both the longitudinal (L) and transverse (T) directions, with at least two tests performed for each condition. Fatigue testing was carried out on two different types of specimen. For fatigue Iife testing, rotating beam specimens were used, where R=-1.0 (R is the ratio of minimum to maximum stress). The notched specimens were longitudinally oriented with relation to the rolling direction in the case of both 8090 and 2014, with a stress concentration factor, Kt, of 1.02. n very Dynamic fatigue testing machine was used, with a frequency of 50Hz. For corrosion fatigue Iife testing, a weeping wick arrangement was used to create a salt water environment from a 3.5% NaCl solution supply. Fatigue crack initiation testing was performed on notched 4-point bend specimens with a Kt of 1.50, using a Servotest 50kN electrohydraulic machine. The 8090 alloy was tested in three directions, L-S, L-T and T-L, with 2014 in the L-S direction, and an R-value of 0.45 was used throughout. Fatigue crack propagation tests were carried out on three-point bend specimens, on the same machine. The same crack orientations, L-S, L-T and T-L, were investigated, with R-values of 0.1 and 0.45.8090 specimens tested in the L-S direction had to be side-grooved in order to produce propagation data. 5% side-grooving was sufficient to stop the crack branching off perpendicular to the intended direction, as shown in Figure 1. For corrosion fatigue initiation and propagation testing the specimens were immersed in an aerated 3.5% NaCl solution, and a frequency of lohz was used. The initiation and propagation of fatigue cracks were monitored by the potential drop technique. Optical and SEM techniques were used to characterize the microstructures of the fracture surfaces. Results The results of the tensile testing are shown in Table I, along with typical values for 8090-T8 for comparison (7). The T8 condition was shown to be typical of 8090 in plate form. In general, the T8 condition gave superior tensile properties when compared to the T6 condition, although the ductility appeared unchanged. The results of the fatigue life tests are shown in Figure 2, for both 8090-T6 and 2014-T6. They are presented in the form of S-N curves, peak stress plotted versus cycles to failure, Nf, for both laboratory air and a 3.5% NaCl solution environment. In general the fatigue life of 2014-T6 exceeded that of 8090-T6 at all stresses except close to the fatigue limit in both air and salt water. Fatigue crack initiation results are presented in Figure 3, for both laboratory air and 3.5% NaCl solution, in the form of S-N curves where peak stress is plotted against cycles to initiation, Ni. gain, the fatigue crack initiation life of 2014-T6 in air exceeded that of 8090-T6 at high stresses, with similar fatigue lives close to the fatigue limit. This effect was not as pronounced in a salt water environment, where 8090-T6 was superior to 2014-T6 at stresses close to the fatigue limit. Fatigue crack propagation data is presented in Test 0.2% PS UTS El Figure 4, plotted as fatigue crack propagation rate, Direction (MPa) (MPa) (%) da/dn, versus cyclic stress intensity factor, K. Results are presented for 8090-T6 and 2014-T6 in 8090-T8 L 450 500 5.5 both laboratory air and 3.5% NaCl solution. In air (typical) (7) T 425 485 6.5 the fatigue crack propagation resistance for 8090-T6 was superior to that of 2014-T6, markedly so at low 8090-T8 L 450 519 5.4 levels of K. t high levels of K, fatigue crack T 426 497 6.6 growth rates were similar for both materials. In a salt water environment fatigue crack growth resistance 8090-T6 L 345 442 6.0 T 369 458 6.5 was more dependent upon crack orientation for 8090-T6. Specimens orientated in the L-S direction showed similar trends to those for laboratory air 2014-T6 481 526 10.0 environments when compared to 2014-T6, with Table I: Tensile properties of 2014 and 8090 superior fatigue crack growth resistance at low levels in different temper conditions. of K and similar propagation rates at high levels.

However, specimens orientated in the T-L direction showed inferior fatigue crack growth resistance to in salt water at high levels of K and only similar propagation rates at low levels of stress. The response of specimens orientated in the L-T direction in salt water was superior to 2014-T6 at low levels of K but inferior at high levels, the cross-over point depending upon the R-ratio. Fracture surfaces of the rotating beam specimens are shown in Figure 5, where crack growth directions are seen to be different with 2014, Figure 5a, and 8090, Figure 5b. SEM examination, Figure 6, shows the types of failure involved with 8090, a combination of delamination of longitudinal grain boundaries, Figure 6a, and transgranular failure, Figure 6b. typical fracture surface for crack propagation specimens can be seen in Figure 7, showing a highly faceted crack path. Discussion and Conclusions The fatigue life tests, Figure 2, show that 2014-T6 offered better fatigue resistance than 8090-T6 at all but low levels of stress, close to the fatigue limit. Similar trends were shown with the fatigue crack initiation results in air, Figure 3a, with superiority being more pronounced at higher stresses. However, fatigue crack propagation rates in air were slower in 8090 than 2014, especially at low levels of K, Figure 4. The lower levels of fatigue resistance in air could therefore be partly atmbuted to poorer fatigue crack initiation properties. Similar observations have been made (4), suggesting that the combination of planar slip and a strong crystallographic texture would lead to early crack nucleation. The fatigue crack initiation resistance of 8090 was better than or equivalent to 2014 in salt water, Figure 3b, so early initiation is not the cause of the lower fatigue life of 8090 in this corrosive environment. The fatigue crack propagation resistance of 8090 was only clearly superior in the L-S direction in salt water, Figure 4. In the L-T orientation, the fatigue crack propagation resistance of 8090 was only superior to 2014 at low levels of & and the T-L orientation had only equivalent crack growth rates at low levels of stress intensity. It would therefore seem that the poorer corrosion fatigue crack propagation resistance of 8090 plays a part in the reduction of fatigue resistance in salt water. The difference in crack growth direction also seems to have affected the fatigue lives of the two materials in rotary bending. Early testing indicated that fatigue cracks preferred to propagate along longitudinally aligned grain boundaries in L-S specimens, Figure 1, which may give rise to inferior fatigue crack growth performance if gross delamination occurs. The results of the fatigue life tests, Figure 2, would appear to support this obsewation.figure 5 shows the transversely oriented crack growth in 2014, Figure Sa, and the mixture of longitudinal and short transverse crack propagation directions in 8090, Figure 5b, in these longitudinally-oriented specimens. The failure in the 8090 specimens was a combination of delamination of longitudinal grain boundaries, Figure 6a, and transgranular failure, Figure 6b. The faster crack propagation associated with this longitudinal delamination would reduce the fatigue life of 8090 when compared to 2014. Whereas the fatigue crack initiation resistance of 8090 was inferior to 2014 in air, it was shown to be superior in salt water, Figure 3a and 3b. The most likely reason for the higher drop in fatigue crack initiation resistance of 2014 due to the corrosive environment is the greater amount of pitting corrosion found with this alloy when compared to 8090. Similar obsewations on the pitting corrosion of 2014 and 8090 have been made (5). Corrosion pits can reduce fatigue crack initiation resistance, and so fatigue life, by introducing stress concentrations at their base. The crack propagation data for 8090 and 2014 in air, Figure 4, are comparable with published data (2,4),with 8090 being superior at all but high levels of K. The slightly better fatigue crack propagation resistance of the 8090 alloy in this investigation with most published data (2,4) may be due to the larger grain size. Similar results have been obtained (8), showing that the improvement in fatigue properties with increasing grain size can be atmbuted to a highly faceted crack path, as shown in Figure 7 for the alloy under investigation. Crack closure effects or crack deflection are therefore the possible cause of increased crack growth resistance. The fatigue crack propagation rates for 8090 did not show the same superiority over 2014 in a salt water environment as they did in air, Figure 4. There are several possible explanations for this. It has been

C3-8 12 JOURNL DE PHYSIQUE shown that planar bands of intense slip, caused in aluminium-lithium alloys by the coherent shearable 6' precipitates, are more sensitive to localised corrosion (9). However, positive evidence of this could not be found during electron microscopy studies. nother possible explanation is the occurrence of hydrogen embrittlement ahead of the crack tip, which has been shown to occur in 8090 (6), and was suggested as a possible stress corrosion mechanism. However, this mechanism would only be seen at low frequencies, and the stress corrosion resistance of 8090 has also been shown to be equivalent to or better than 2014 (5,6). The build-up of lithium-ion concentration in the electrolyte within the crack is another possibility for the reduction of fatigue crack resistance of 8090 in a salt water environment, and would also explain the absence of a corresponding reduction in corrosion fatigue crack initiation resistance. Dissolution processes are accelerated by an increase in lithium ion concentration (6), as may occur in the salt water solution close to the tip of a fatigue crack. Lithium ion concentration would not increase noticeably in the aerated bulk solution, so fatigue crack initiation would not be affected. The propagation of fatigue cracks in aluminium-lithium alloys is clearly complex. Detailed examination of the mechanisms of propagation in air and a corrosive environment is beyond the scope of this paper and requires further study. cknowledeements This work has been canied out with the financial support of the Science and Engineering Research Council (SERC) and Dunlop viation Ltd. Thanks are also extended to Prof.J.T.Barnby for his supervision of the project. References 1. D.Little, in "3rd Int. Conf. on 1-Li lloys", Inst. of Metals (1986), pp.15-21. 2. C.J.Pee1, B.Evans, C..Baker, D..Bennett, P.J.Gregson, H.M.Flower, in "2nd Int. Conf. on I-Li lloys", IME (1984), pp.363-392. 3. C.J.Pee1, B.Evans, D.McDarmaid, in "3rd Int. Conf. on 1-Li lloys", Inst. of Metals (1986), pp.26-36. 4.. M.Peters, K.Welpmann, W.Zink, T.H.Sanders Jr., in "3rd Int. Conf. on l-li lloys", Inst. of Metals (1986), pp.239-246. 5. P.L.Lane, J..Gray, C.J.E.Smith, in "3rd Int. Conf. on 1-Li lloys", Inst. of Metals (1986), pp.273-281. 6. N.J.H.Holroyd,.Gray, G.M.Scamans, R.Hermann, in "3rd Int. Conf. on I-Li lloys", Inst. of Metals (1986), pp.310-320. 7. M..Reynolds,.Gray, E.Creed, R.M.Jordan,.P.Titchener, in "3rd Int. Conf. on l-li lloys", Inst. of Metals (1986), pp.57-65. 8. S.J.Hanis, B.Noble, K-Dinsdale, in "luminium Technology '86", Inst. of Metals (1986), pp.451-458. 9. E..Starke, Jr., G.Lutjering, in "Fatigue and Microstructure", SM (1979), pp.205-243.

400 3 24 8 100 &I - 2014 (IR) + 2014 (SW) 8090(SW) Kt = 1.02 +, * + 4 * + *+ + **+ 0 0 103 1 o4 I 05 1 o6 1 o7 108 Cycles to Failure (Nf) Figure 2: Fatigue life curves for 8090-T6 and 2014-T6 in laboratory air and 3.5% NaCl solution. Cycles to Initiation mi) Figure 3: Fatigue crack initiation curves for 8090-T6 and 2014-T6 in laboratory air (a) and 3.5% NaCl solution (b).

JOURNL DE PHYSIQUE t 8090(L-S) 8090(L-1) - ++f P ;+ $ I B M a& P R=0.1 IR lo-.!.... 10 ' IR 50 R=0.45 SLT WTER Figure 4: Fatigue crack propagation curves for 8090-T6 and 2014-T6.

Figure 1: Delamination in 8090 (L-S) specimens without side-grooves. a Figure 6: Fracture surfaces of 8090 rotating beam specimens. Figure 5: Crack growth directions in rotating beam specimens, for 2014 (a) and 8090 (b). Figure 7: Fracture surface of 8090 fatigue crack propagation specimens.