VaproFlashing PRODUCT DATA SHEET

Similar documents
PART 1 - GENERAL PROJECT NAME SECTION VAPOR PERMEABLE AIR BARRIER

Air and Vapor Barrier 3015

SECTION WATER-RESISTIVE AIR BARRIER MEMBRANE

SECTION SELF-ADHERING WATER-RESISTIVE AIR BARRIER MEMBRANE

SECTION WATER-RESISTIVE AIR BARRIER MEMBRANE

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

SECTION SELF-ADHERING WATER-RESISTIVE AIR BARRIER MEMBRANE

Guide Specification for the OSI QUAD Window and Door Flashing System

Single Component 100% Silicone Sealant INSTALLATION INSTRUCTIONS

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane

Perm-A-Barrier NPS (Non Permeable Sheet)

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Perm-A-Barrier VPS (Vapor Permeable Sheet)

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

SRP-AirOutshield UV Issued:

SECTION FLUID APPLIED VAPOR PERMEABLE AIR BARRIER MEMBRANE

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

A. Section includes fluid applied, vapor permeable membrane air barriers.

WrapShield SA Brick Tie Penetration

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

SECTION Self-adhered sheet membrane water resistive air barriers, vapor permeable

Product and System Specifications DuPont Flashing Systems

JOHNS MANVILLE CONTINUOUS INSULATION WALL SYSTEM MASTER SPECIFICATION June 2014 CSI FORMAT SECTION FOIL-FACED RIGID INSULATION

SECTION FIRE RESIST 705 VP FULLY-ADHERED SHEET AIR & WATER RESISTIVE BARRIER

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

breathability to prevent the potential for moisture condensation within exterior walls...

80648 StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Henry Blueskin VP160 Air Barrier System Installation Manual

PlyDry is specified by builders who need a perforated housewrap that meets code requirements at a very affordable price...

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

Section Pre-Applied Sheet Membrane Waterproofing

3M Canada Weather Barriers Section Master Guide Specification Page 1 April 2012

SECTION AIR / MOISTURE / VAPOR BARRIERS 1

3M Canada Air Barriers Section Master Guide Specification Page 1 April 2012

BENJAMIN OBDYKE INCORPORATED

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

PERM-A-BARRIER NPS Detail Membrane

80230 StoColor Coat Sand Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

ROOFING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR SELF-ADHERED UNDERLAYMENTS FOR USE IN DISCONTINUOUS ROOF SYSTEMS

80201 StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

SuperiorFlash. masterwall.com PO Box 397 Fortson GA Tech:

Proof positive. The Science Behind the System.

Note to Specifier: Use this product for coated glass-mat faced polyisocyanurate insulation boards such as Rboard.

RevealShield SA Penetrations

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

SECTION SELF-ADHERING SHEET FLASHING

SECTION VAPOR IMPERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

SECTION CONCRETE AND MASONRY COATINGS

Tensile ASTM D1970 MD = 939 psi / CD = 1252 psi Self Sealability / water penetration resistance around nails. ASTM D1970 Section 7.

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

AIR BARRIERS & WATER-RESISTIVE BARRIERS

SECTION FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS

BREATHABLE MEMBRANES. Canada Inc. Water Vapour Permeable, Air Barriers for Sloped Roofs & Rain Screen Wall Systems

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

1/2 in. (12.7 mm) and 5/8 in. (15.9 mm) glass mesh. It has an exceptionally hard, durable surface that can withstand prolonged exposure to moisture.

80657 StoColor Texture - Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

Proof positive. The Science Behind the System.

SECTION MANUFACTURED ROOF EXPANSION JOINTS

PER See all Pei ES Listings at:

Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS Specifications

SECTION Blown Insulation THERMAL INSULATION

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION SPRAY FOAM INSULATION

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS. A. Section Includes: 1. Fluid-applied, vapor-impermeable, water-resistive membrane air barriers.

SECTION FLUID-APPLIED WEATHER AND AIR BARRIER SYSTEM FOR VENTILATED CAVITY

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

SECTION THERMAL INSULATION

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

Pacific Polymers Elasto-Deck BT Guide Specification

R Guard AIR & WATER BARRIER. FastFlash

WRAP. Housewrap is the best practice for protecting a home from wind and water while allowing it to breathe. Norandex makes it easy!

DUPONT TYVEK COMMERCIAL SOLUTIONS

SECTION SHEET MEMBRANE WATERPROOFING

SECTION FOIL FACED POLYISOCYANURATE FOAM BOARD INSULATION. A. Rigid polyisocyanurate foam board insulation with aluminum facers.

UltraPly TPO SA. Product Information. Description: Membrane Preparation: Method of Application: Item Description

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Architectural Roof Products Guide Specifications

Delivery, Storage, and Handling

80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

(Project Location) (your firm's name)

Section COATING RESTORATION

Architectural Roof Products Guide Specifications

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Student Services & Classroom Addition

Transcription:

WrapShield IT Integrated Tape a mechanically attached, water resistive vapor permeable air barrier membrane with integrated tape at the horizontal seams: Product No: 16109000 VaproFlashing Product No.: 40105500 / 40108000 Product Description WrapShield IT Integrated Tape WRB/Air Barrier membrane protects the building envelope by allowing vapor pass through (breathable) but not air or liquid water mitigating costly moisture damage and saving energy for the life of the building. BASIC USE WrapShield IT Integrated Tape is installed above grade behind rain screen wall cladding assemblies. MATERIALS WrapShield IT Integrated Tape consists of multiple layers of spun-bonded polypropylene fabric with clear integrated horizontal tape and pre-marked lap template ensuring accurate horizontal seams. BENEFITS Superior building envelope protection high drying capacity (59 perms) allows building materials to dry-out, reducing the risk of damage from moisture infiltration, mold, mildew and rot for the life of the building. Factory installed clear integrated tape seals horizontal seams ensuring the upper layer shingles over the lower layer creating the 6 shingled effect. Pre-marked shingle template increases installation accuracy. Air tight barrier stops air infiltration as per the ASTM 2357 Air Barrier assembly test. Consistent millage thickness factory made rolled good ensures consistent properties and performance. Fully tested building envelope system rough opening flashing accessories eliminate the need for untested outside components. Mechanically attaches to multiple substrates using VaproCaps. Compatible Substrates OSB Exterior Gypsum Sheathing Rigid Insulation Precast Concrete Concrete Block Cast-in-place Concrete Plywood Pre-painted Steel Galvanized Metal Aluminum (Painted/Mill Finish) Anodized Aluminum Vinyl Window and Door Frames Fiberglass Window and Door Frames Simple installation requires only basic tools, no specialized mobilizations or protection gear are required. Apply to clean and dry-to-the-touch as new substrates, no additional preparation is required. Spans substrate joint gaps up to 7/8 (22.2mm), eliminates need for tapes and fillers. Phase construction ready, install in all temperatures sustains up to 180 days UV and climate exposure prior to cladding installation. Emits zero VOCs, no primer required, ensuring crew safety and a healthy building. Technical Data & Environmental Passed and tested to industry standards for Weather Resistive Barriers. WrapShield IT Integrated tape emits zero VOCs, making the membrane safe for work crews and occupants for the life of the building. Color Thickness PROPERTY PHYSICAL PROPERTIES RESULT Orange (top), White (back) 0.5581 mm (21.97 mil) Membrane Weight 193.7 g/m 2 ( 0.635 oz/ft 2 ) Roll Weight 32 lbs (14 kg) Roll Dimensions 59" x 164' (1.5m x 50m) Roll Coverage Skid VOCs Ultra Violet Light Exposure Minimum Application Temperature Service Temperature Warranty 807 sq. ft. (75 sq. m.) 25 Rolls None 180 days maximum None minus 40 F (-40 C) - 225 F (107 C) 20 year material warranty Contact VaproShield Technical if you have additional substrate questions. 1 of 5

Complete Building Envelope System WRB/AIR BARRIER WrapShield IT Integrated Tape BEST PRACTICE INSTALLATION ROUGH OPENING FLASHING OPTIONS Self-adhered air barrier transition and flashing shall be: VaproFlashing SA Self-Adhered in conjunction with: VaproLiqui-Flash, Vapro-SS Flashing and/or VaproBond for rough opening and penetration flashings. Reference individual data sheets for comprehensive information. Secure membrane with stainless steel stapes above integrated tape. Align the bottom of the upper course with the dotted line for proper 6 (15 cm) overlap. Join horizontal seams by peeling back both release films. Tape seals horizontal seams. Rough Opening Flashing Membranes Product Part No. Roll Sizes VaproFlashing SA Self-Adhered Roll VaproFlashing Roll (Mechanically Attached) 46105590 46108090 40105500 40108000 Roll Size: 11 3/4 x 164 (298mm x 50m) 161 S/F (15 S/M) Roll Size: 19 2/3 x 164 (500mm x 50m) 269 S/F (25 S/M) Roll Size: 11 3/4 x 164 (298mm x 50m) 161 S/F (15 S/M) Roll Size: 19 2/3 x 164 (500mm x 50m) (25 S/M) Weight: 9.5lbs (4.3kg) Upper course is now properly shingled over the lower course, eliminating water concerns at the horizontal joints. Roll the integrated tape seam with floor roller to ensure full contact In conjunction with: Window and Rough Openings Flashing VaproLiqui-Flash Vapro-SS Flashing VaproBond BEST PRACTICE VERTICAL SEAMS Application Temperature 35 F to100 F (2 C to 38 C) 20 F to 170 F (-6 C to 77 C) -50 F to 300 F (-45 to 149 C) Drying Capacity Breathable Permeability High None Low Application Method Sausage Gun / Putty Knife or Brush Utility Knife / J-Roller Sausage Gun / Putty Knife Overlap vertical seams by min. 12. Apply ¼ (6.4 mm) bead of VaproBond adhesive sealant to ensure water and air barrier seal. Peel back release films to finish horizontal seam. For complete installation instructions, visit VaproShield.com. 2 of 5

Commercial Window Rough Opening Flashing System with VaproFlashing SA Field membrane cut flush with edge of R.O. 9 11.75 - Membrane is left unattached until window and head flashing are installed VaproLiqui-Flash full coverage inside rough opening + 1 on face VaproFlashing Self-Adhered properly shingled; applied directly to field membrane + folded 2.75 inside of rough opening WrapShield IT field membrane installed horizontally Visit VaproShield.com to view full installation sequence RELATED LEED CREDITS WrapShield IT Integrated tape WRB/Air Barrier contributes to Environmental Quality ( EQ ) credit 4.1: Low Emitting Materials: Adhesives & Sealants, under United States Green Building Council s Rating System for New Construction and Major Renovations (LEED-NC), version 2.2, core and shell (LEED-CS), version 2.0. Installation STORAGE AND HANDLING Store material rolls on end in original packaging. Protect rolls from direct sunlight and inclement weather until ready for use. SAFETY Work crews are safe around VaproShield membranes. WrapShield IT Integrated Tape contains zero VOCs or toxins. PREPARATION All surfaces must be dry, sound, clean, as new condition, and free of oil, grease, dirt, excess mortar or other contaminants detrimental to the adhesion of the water resistive air barrier membrane and flashings. Fill voids and gaps in substrate greater than 7/8 inch (22.2 mm) in width to provide an even surface. Strike masonry joints full-flush. BEST PRACTICE INSTALLATION Install WrapShield IT with approved fasteners in a horizontal, shingle fashion. Horizontal overlaps must be 6 (15 cm) to properly seal the integrated tape joint. Vertical overlaps must be minimum 12 (30 cm) and require VaproBond adhesive sealant, to provide an air barrier seal. Vertical overlaps are to be staggered a minimum of 24 (61 cm) and should not occur directly above or below windows or doors. Inside and outside corners can be continuous, or if a vertical joint occurs within 24 horizontally, an overlap of 12 minimum in both directions is required, providing a double layer at the corner. Visit www.vaproshield.com for complete installation instructions and instructional videos. LIMITATIONS WrapShield IT Integrated Tape should be covered within 180 days of installation. Do not contaminate WrapShield IT Integrated Tape WRB/ Air Barrier with building site chemicals which make it more wettable (e.g., surfactants), This will adversely affect its water resistance and therefore its contribution to the water resistance of the overall wall system. WrapShield IT Integrated Tape WRB/Air Barrier should not be subjected to asphaltic materials, chemicals, surfactants, or cleaning compounds that could affect the water resistance of the membrane surface; if exposed, replace effected membrane. Availability VaproShield products are available throughout North America, Central and South America, and New Zealand. Warranty A 20-year material warranty is available. 3 of 5

Strength TESTING DATA PROPERTY STANDARD RESULT Dry Tensile Strength 20 lbf/in ASTM D828 Standard Test Method for Tensile Properties of Paper and Paperboard Using Constant-Rate-of-Elongation Apparatus MD - 171 N (38.6 lbf) XMD - 104 N (23.3 lbf) Dry Tensile Strength ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic Sheeting Control - 8.89 N/mm (50.8 lbf/inch) UV Exposure - 8.16 N/mm (46.6 lbf/inch) UV + Heat Exposure - 8.16 N/mm (46.6 lbf/inch) Dry Breaking Force (Grab method) MD 40 XMD 35 ASTM D5034 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test) MD 445.3 N (100.1 lbf) CD 383.0 N (86.1 lbf) Cold Mandrel Bend Test AC38 Section 3.3.4 Warp (Machine) Direction - No cracking Filling (Cross) Direction - No cracking Weathering Tests Water Vapor Transmittance Desiccant Method 24.4 C (76.0 F) 50 %RH Water Method 24.4 C (76.0 F) 50 %RH Dynamic Relative Humidity Measurement (23 C 50 %RH) Air Resistance Testing AC38 Section 4.1.2 UV Exposure AC38 Section 4.1.3 Accelerated Aging ASTM E96 Standard Test Methods for of Materials ASTM E96 Standard Test Methods for of Materials ASTM E398 Standard Test Method for Rate of Sheet Materials Using Dynamic Relative Humidity Measurement UV - No visual change UV & Accelerated - visibly lighter, no visible deterioration 21 Perm (grain/h ft 2 inchhg) 1201 ng/pa s m 2 66.9 Perm (grains/hr ft 2 inchhg) 3828 ng/pa s m 2 71.91 Perm (grain/h ft 2 inchhg) 4114 ng/pa s m 2 Air Permeance ASTM E2178 @75 Pa Standard Test Method for Air Permeance of Building Materials 0.0004 L/s m 2 @ 75 Pa (0.0001 cfm/ft 2 @ 1.57 psf) Air Barrier ASTM E2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies <0.01 L/s m 2 @ 75 Pa (<0.01 cfm/ft 2 @ 1.57 psf) Air Barrier Water Resistance Testing Nail Sealability ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen ASTM D1970/ section 7.9 Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection <0.01 L/s m 2 @ 75 Pa (<0.01 cfm/ft 2 @ 1.57 psf) Pass - Review Fastener Penetrations Technical Bulletin at VaproShield.com Water Resistance (Boat Test) Water Resistance (Control after Weathering) Static Water Penetration Test Fire Testing ASTM D779 Standard Test Method for Water Resistance of Paper, Paperboard, and Other Sheet Materials by the Dry Indicator Method (Withdrawn 2011) AATCC 127 Hydrostatic pressure test (550 mm water column for 5 hours), American Association of Textile Chemists and Colorists ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference" Control - No leakage Weathered - No Leakage Control - No leakage Weathered - No Leakage Mockup tested at 15 psf for 15 minutes, No leaks Flame Spread Smoke Developed ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials Flame Spread 0 Smoke Developed 55 Cone Calorimeter Testing Data NFPA 285 Compliant ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter ASTM E1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter Time to ignition: 20 sec Flame Duration: 62 sec Ave. Effective Heat of Combustion: 11.0 MJ/kg Ave. HRR at 60 sec: 74 kw/m 2 Ave. HRR at 180 sec: 0 Peak HRR: 125 kw/m 2 Time of Peak: 26 Total HRR/A: 4.6 MJ/m 2 View over 50 compliant assemblies with various manufacturers at VaproShield.com or Contact VaproShield Technical Team, 1-866-731-7663 opt. 5 4 of 5

TESTING DATA PROPERTY STANDARD RESULT CANADIAN STANDARDS Air Leakage Rate CAN/CGSB 51.32 Classification A1 - PASS Multiple CAN/ULC-S742-11 Sheathing Membrane, Breather Type PASS 5 of 5