California Groundwater Association An NGWA Affiliate State 700 R Street Suite 200 Sacramento, CA

Similar documents
(this page left intentionally blank)

General Groundwater Concepts

CHAPTER 32 - WELL ABANDONMENT ORDINANCE OF DUBUQUE COUNTY, IOWA. Adopted September 5, Part 1 Introduction...2

SECTION GRAVEL PACKED WATER WELL

CHAPTER 39 REQUIREMENTS FOR PROPERLY PLUGGING ABANDONED WELLS

Module 3 Design and Construction of Water Wells. For more information refer to the Water Wells That Last video (Part I Planning and Construction).

Appendix VIII. Guidelines for groundwater bores and wells

MUD ROTARY TECHNIQUES. MUD Rotary Drilling Method 12/11/2017. Roger E. Renner, MGWC MUD ROTARY DRILLING. Rotary Well Rig

Part 4 CONSTRUCTION OF WELLS AND THE WITHDRAWAL OF GROUNDWATER Purpose. [Ord , -/-/2002, 1]

INVESTIGATION RESULTS

Assisting Energy Savings While Protecting 2009 REVISIONS TO GUIDELINES FOR THE CONSTRUCTION OF VERTICAL BOREHOLES

Water Wells for Florida Irrigation Systems 1

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

Article 495 WELL YIELD PUMPING FOR RESIDENTIAL PROPERTY TRANSFERS Adopted by the CGA Board of Directors on October 14, 2006

Lagoon Pumping and Irrigating Equipment

SECTION WASTEWATER FORCE MAINS

1. All underground utilities under railroad tracks shall be encased in a larger pipe or conduit called the casing pipe.

SECTION WASTEWATER FORCE MAINS

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 652. UNDERGROUND INJECTION CONTROL

Environmental Management Chapter

GRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS

REQUEST FOR BIDS WELL DRILLING & TESTING SERVICES I-77 EXIT 1 WATER SYSTEM PROJECT DESCRIPTION

AWWA CA NV Section Spring Conference Sacramento March 24, :30 AM 9:00 AM Session 22 Water Well Technology

9. Equipment Installation

Water Well Drilling Agreements

Background. AEM Tier 2 Worksheet Farmstead Water Supply Evaluation. AEM Principle: Glossary

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

NGWA s Water Well Construction Standard: ANSI/NGWA 01-14

Identification. Module 4 Water Well Drilling Agreements

FLOWING ARTESIAN WELLS

PROPOSED REGULATION OF THE STATE ENGINEER. LCB File No. R May 1, 2012

ITEM 416 DRILLED SHAFT FOUNDATIONS Materials. All materials shall conform to the requirements of the pertinent items as follows:

15A NCAC 02C.0225 GROUNDWATER REMEDIATION WELLS (a) Groundwater Remediation Wells are used to inject additives, treated groundwater, or ambient air

15A NCAC 02C.0219 AQUIFER STORAGE AND RECOVERY WELLS (a) Aquifer Storage and Recovery Wells are used to inject potable water for the purposes of

GRAYWATER STANDARD PLAN For Simple Residential System

PROJECT MANUAL PART 2

Ground Water and Wells. Basic (Geo)Science for Sustainable a Future. Dr. David Boutt. UMass Amherst, Geosciences Department

Troubleshooting Water Well Problems

Subject: Aquifer Test Observation Well Installation Work Plan Hilmar Cheese Company, Hilmar, Merced County, CA

SECTION MONITORING WELL ABANDONMENT

Section WATER LINE IN TUNNELS

SECTION 920 SANITARY AND STORM SEWER MANHOLES

PROVINCE OF BRITISH COLUMBIA ORDER OF THE LIEUTENANT GOVERNOR IN COUNCIL

D.G.S.W. Pitakumbura Manager (Groundwater Studies) Groundwater Section NWS&DB. Groundwater recharge or deep drainage or

Wastewater Capital Projects Management Standard Construction Specification

Soil Improvement by Compaction Grouting

Flowing Artesian Wells

SUBSIDIARY LEGISLATION BOREHOLE DRILLING AND EXCAVATION WORKS WITHIN THE SATURATED ZONE REGULATIONS

POINT OF SALE INSPECTION SEWAGE TREATMENT SYSTEM (STS) AND/OR PRIVATE WATER SYSTEM (PWS)

Flowing Artesian Wells

F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it.

BROWARD COUNTY ENVIRONMENTAL PROTECTION DEPARTMENT (EPD) MINIMUM CRITERIA FOR MONITORING WELL INSTALLATION AND SAMPLING

SECTION SLUDGE HOLDING TANK DEWATERING

SOUTHERN NEVADA AMENDMENTS TO THE 2012 UNIFORM MECHANICAL CODE

SEPTIC TANK CONSTRUCTION GUIDELINES

True False Click and Drag Artesian wells are naturally under pressure and require no additional pumps to get the water out of the ground.

Wellhead Protection General Guidelines for New Private Domestic Wells

DIVISION 33 - UTILITIES SECTION UTILITY PIPE BORING AND JACKING DIVISION 33 UTILITIES SECTION UTILITY PIPE BORING AND JACKING

CITY OF BLOOMINGDALE WELL DRILLING APPLICATION. Estimated depth in feet & method of construction: Purpose of Well & Desired Yield:

HALIFAX BOARD OF HEALTH REGULATIONS FOR PRIVATE WELLS

SPECIAL CONDITIONS FOR PIPE JACKING (PJ) October, 2006

Wellhead Protection General Guidelines for Existing Private Domestic Wells. Wellhead Protection Recommendations for Well Owners:

BELOW-GRADE INJECTION WATERPROOFING

Publication No. 26: Private Drinking Water Wells Types of Construction

WATER LINE IN TUNNELS

5.0 - WATER SUPPLY WELLS

SECTION 820 PUMP STATION DEMOLITION AND SITE RESTORATION

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

Except as otherwise noted, the definitions in rule of the Administrative Code shall apply to this chapter.

SPECIFICATION : BORING AND JACKING

Student s Guide Lesson 3- Installation Process Version 1-1/

CHANGES IN 2006 SPECIFICATIONS SECTION 804 DRIVEN PILES SECTION 814 DRILLED SHAFTS

WATERLINK LIMITED COMPANY PROFILE

CHAPTER 49 NONPUBLIC WATER SUPPLY WELLS [Prior to 7/1/83, Health Dept. Ch 45] [Prior to 12/3/86, Water, Air and Waste Management[900]]

Hydrologic Cycle. Rain Shadow:

STANDARD SPECIFICATIONS

GRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS

Water Well Decommissioning Guidelines

ITEM 432 TUNNEL CONSTRUCTION

TOWNSHIP OF FRANKLIN YORK COUNTY, PENNSYLVANIA ORDINANCE NO

SPECIAL CONDITIONS FOR HORIZONTAL AUGER BORING (HAB) October, 2006

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

SECTION CS-2. TRENCH EXCAVATION CONSTRUCTION STANDARDS

REPORT OF GEOTECHNICAL EXPLORATION WEST MARJORY AVENUE TAMPA, FLORIDA

BUTTE COUNTY WELL CONSTRUCTION MANUAL

DEFINITIONS. A shallow bored hole under the derrick substructure in which the kelly is temporarily stored during tripping operations.

HENRY COUNTY WATER ORDINANCE

703 - DRILLED SHAFTS SECTION 703 DRILLED SHAFTS

Worksheet #1 Assessing the Risk of Groundwater Contamination from Drinking Water Well Condition

Water Wells and Ground Source Heat Exchange Systems

#47 CASE STUDY INSTALLATION OF A SOIL-BENTONITE CUTOFF WALL THROUGH AN ABANDONED COAL MINE (GROVE CITY, PA)

Case Study Casing Path Well An Effective Method to Deal with Cascading Water

SPECIFICATIONS - DETAILED PROVISIONS Section Water Well Drilling, Casing & Testing TABLE OF CONTENTS

HORIZONTAL BORING HORIZONTAL BORING. Underground Electric Distribution Standards I. GENERAL

Healthy Drinking Waters

SUBSURFACE ROTARY DRILLING INVESTIGATION SPECIFICATIONS

Water Safety Plan Guide Groundwater Abstraction Bores and Wells Version 1, Ref P1.3

STANDARD OPERATING PROCEDURES

Suitable Applications Where concentrated flow of surface runoff must be conveyed down a slope in order to prevent erosion.

SECTION IRRIGATION WATER WELL

Transcription:

California Groundwater Association An NGWA Affiliate State 700 R Street Suite 200 Sacramento, CA 95811 cga@groundh2o.org 916-231-2134 CGA STANDARD PRACTICE SERIES ARTICLE 550 MANAGEMENT OF SURFACE ARTESIAN FLOWS DURING VERTICAL WELL CONSTRUCTION BACKGROUND Flowing artesian wells are the result of water percolating into an aquifer, which is confined or semi-confined beneath an impermeable layer that is in turn penetrated by a well boring. When the surface of the water charging the aquifer is higher than the ground level of the well, water flows at the well head onto the ground. For purposes of this standard, the term flowing artesian well applies to vertical wells where water flows at the well head onto the ground. The California Water Code addresses flowing artesian wells in Division 1, Chapter 2.5, Article 4, Sections 300-311. These sections define a flowing artesian well; what constitutes waste; beneficial use of water flowing from an artesian well; and the maximum annual accumulated flow that can be used. In section 305 the Article states that an artesian well which is not capped or equipped with a mechanical controlling device is a public nuisance. Further, the article provides that any person who permits such a public nuisance to exist or permits water to flow unnecessarily to waste is punishable by a fine, or imprisonment, or both. Containment of flowing water on the land is allowed, provided the California Water Code s usage and volume restrictions are met. However, if containment on the land is not possible, or if allowable usage is exceeded, the only solutions described in the Article for preventing flow to waste are by capping the well and/or equipping it with a controlling device such as a valve. While this is a reasonable solution for undeveloped wells without installed pumping equipment, there are potential problems once submersible pumps are installed or when periodic access to the well is required. Problems also arise during the well construction process if artesian flows are not properly managed. The purpose of this standard is to define these potential problems as well as provide basic guidelines and solutions that will make compliance with Article 4 possible and yet still allow intended usage of the well. Page 1 of 4

DISCUSSION The California Water Code does not make a distinction between artesian and flowing artesian wells. According to the definition found in Section 300 of the California Water Code an artesian hole is any penetration of the surface through which water flows to the surface for any length of time. Section 301 of the California Water Code defines as waste any water flowing from an artesian well that runs into natural water courses, streets, highways, or upon land, unless it is used for irrigation, domestic purposes, or the propagation of fish. Water from an artesian well may be contained by means of an artificial pond or reservoir if the water is used thereafter for a beneficial use. Even if the artesian water is used for a beneficial use, Section 304 limits the amount of water used to one tenth of one miner s inch of water per acre, perpetual flow, with the ability to accumulate that amount within any period of each year. In 1901, the California legislature dictated that a miner s inch is to be equal to 1.5 cubic feet of water per minute (11 gallons per minute), while in southern California, regardless of the legal definition, a miner s inch is considered equal to 1.2 cubic feet of water per minute (9 gallons per minute). Furthermore, Section 305 requires that artesian wells be capped or equipped with a mechanical appliance which will readily and effectively arrest and prevent the flow of any water from the well. California Water Code Sections 306 and 307 place liability upon any person owning, possessing, or occupying any land with an artesian well that fails to control and fails contain the water and to comply with the other conditions of the California Water Code. The consequences of not complying with the provisions of the California Water Code are potentially large fines, imprisonment, and civil liability for aquifer and environmental damage. Flowing artesian wells occur in confined aquifers where the potentiometric pressure is sufficient to push water above the ground surface once the confined aquifer is tapped. Since the static water level is above the ground surface in an artesian condition, the water flows out of the borehole. The amount of pressure the flowing artesian condition creates is dependent upon how high the static water level is above the ground level; for every 2.31 feet of hydrostatic head one pound per square inch (psi) of hydrostatic pressure is generated. The amount of flow and total flow volume is related to aquifer volume, soil porosity, and recharge rates. Depending on the source of the artesian flow, flowing artesian wells may be permanent, intermittent, or may discharge seasonally variable volumes and pressures. In certain instances, the artesian pressure may only occasionally be high enough to cause surface flow, such as during an unusually wet winter or following a heavy rainfall. Additionally, pumping a flowing artesian well may result in a temporary, or even permanent, loss of hydrostatic pressure and/or flow due to drawdown in the confined aquifer. Any method that is employed to contain an artesian flow should be able to withstand the lifting pressure that the artesian condition may exert. The artesian pressure will exert a lifting force on the top of the well, well casing, and annular seal. Therefore, the downward force exerted by casing weight, pump and pipe weight, and friction on the pipe due to the Page 2 of 4

annular seal must be greater than the upward force exerted by the artesian condition. Thus, it is oftentimes better to rely on overbuilding a flowing artesian well; methods such as, but not limited to, heavier well casing material, deeper annular seal, and stronger grout in the annular seal can be utilized to control the artesian flow. During well completion, the artesian flow will also cause problems when trying to work on the well head unless provisions are made to temporarily reroute the water away from the well head. Putting a diversion pipe and valve mechanism below the well head, but above the ground surface, will provide a mechanism to reroute the water away from the well head while work is being performed in this area. Once the artesian flow is temporarily rerouted, it is easier to control artesian flows and pressures in artesian wells. In wells that are to be permanently capped, watertight modifications can now be made easier, e.g. welding or other means of permanently placing a cap. In wells that may require periodic access or wells with pumps installed, containment of artesian flows is more difficult. Oftentimes, the well top will be equipped with a mechanical appliance such as a pump sanitary seal through which the pump column pipe, pump electrical cable, and other appurtenances pass. Typically, this seal consists of rubber sandwiched between two plates made of steel or composite material. As the steel plates are compressed, the rubber expands, forming a watertight seal. To be effective, the well casing, annular seal, pump sanitary seal and other appurtenances must also be watertight and able to overcome any upward force that may be imposed when artesian pressures are permanently or intermittently elevated. During well drilling operations, well construction, and for the life of the flowing artesian well, flowing artesian water can create a myriad of problems for the well drilling contractor and property owner. For the mud rotary driller, the increased water tends to reduce the weight of the drilling fluid, which can cause problems with borehole stability and surface water runoff. For the air rotary driller, the water can lead to borehole collapse, ground surface instability, as well as water runoff issues. For the pump installer, the artesian flow causes waterproofing and containment issues. The property owner faces liability issues for waste of water as well as the potential for increased well construction costs. For all parties involved, the problems associated with flowing artesian wells will have to be mitigated or the borehole may have to be abandoned in entirety. RECOMMENDATIONS 1. The owner, occupant, or tenant of a property with a flowing artesian well should be informed of their responsibilities to control the artesian flow and to review California Water Code, Division 1, Chapter 2.5, Article 4, Sections 300-311. The URL is <http://www.leginfo.ca.gov/calaw.html>. 2. Components used by the well drilling contractor during construction of an artesian well should be capable of withstanding anticipated artesian flows and pressures. Page 3 of 4

3. The well drilling contractor should, whenever possible, learn about the area and anticipate artesian flow. 4. The well drilling contractor who anticipates the possibility of artesian flow should exercise locally and regionally established best management practices (BMPs). 5. If an artesian flow is anticipated, the drilling contractor should plan to install a conductor casing prior to reaching the anticipated artesian condition. The conductor casing and sealing material should have sufficient structural strength and depth to withstand anticipated forces exerted by the artesian pressure. 6. Where artesian flow is not anticipated and an annular seal must be installed after artesian flow is encountered, the drilling contractor may need to install a pump in the well that can pump at a higher rate than the artesian flow to allow the annular seal to be placed. All annular seals should be placed via tremie pipe. 7. When mud rotary drilling, the best way to deal with artesian flow is to increase the weight of the drilling mud by using weight adding products, such as barite. 8. Steel cased wells may be capped with a solidly welded plate, pump sanitary seal, or other appropriate flow arresting device. Plastic cased wells may be capped with a solvent welded cap, pump sanitary seal, or other appropriate flow arresting device. Pump sanitary seals should be tightened against the casing sufficiently to prevent leakage. Strapping or other methods can also be used to help the pump sanitary seal withstand the potential upward force from the artesian condition. Additionally, a flange and blind flange sanitary seal may be considered. 9. Cased artesian wells should be outfitted with a diversion pipe and valve of sufficient size and pressure rating to allow maximum artesian flow to exit the well below the top of the well head. This discharge pipe eases well head service and acts as a controlled discharge of artesian water in accordance with the California Water Code. Discharge piping from the controlling valve should terminate with a screened covering or cap when not in use. 10. For wells with installed pumping equipment, electrical conduits should be sealed to prevent water flow and should be capable of withstanding the potential artesian pressure. Conduit connections through the pump sanitary seal should be plugged with a suitable sealing agent, such as resin epoxy. If a well vent is installed, the well vent should be capable of stopping water flow or installed with a check valve. 11. In cases where the quantity of the artesian flow is of immediate concern, or where drilling operations must cease temporarily, adequate means to control the artesian condition should be utilized. * * * * Page 4 of 4

Adopted by the CGA Board of Directors on October 13, 2007 Page 5 of 4