RETROFIT-SD-AB INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS BRAVO FIBERGLASS SD-AB SERIES FOR DOUBLE WALL FRP SUMPS ONLY FOR RETROFITTING ALL FLEXIBLE ENTRY BOOTS

INSTALLATION INSTRUCTIONS BRAVO FIBERGLASS RETROFIT-S SERIES FOR SINGLE WALL FRP SUMPS ONLY FOR RETROFITTING ALL FLEXIBLE ENTRY BOOTS

FPE-SERIES RETROFIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS F-SERIES D-INR-S SPLIT RETROFIT FOR REPLACING BOLTED FLEXIBLE ENTRY FITTINGS FOR FIBERGLASS PIPE AND STEEL CONDUIT ONLY

BRAVO F-SERIES AMERON LCX

BRAVO F-SERIES AMERON LCX

INSTALLATION INSTRUCTIONS B-407-RB SERIES SINGLEWALL RETROFIT TANK SUMP

INSTALLATION INSTRUCTIONS B407-PP SERIES SINGLEWALL TANK SUMP

B-500 / B-600 SERIES

B500-VRC / B600-VRC SERIES INSTRUCTIONS DETAILS RS-500-VRC INSTALLATION

INSTALLATION MANUAL. B-710/760 H20 SERIES MODULAR UST to AST TRANSITION SUMP

INSTALLATION INSTRUCTIONS RC-SERIES SNAP-LOCK RETROFIT FOR FIBERGLASS CONTAINMENT SUMPS

B-600 Commercial Series

Acetone is flammable; refer to the manufacturer s instructions for complete safety information.

Warning. Warning. (2) Bondo knives one 4 and one 6 (can be purchased locally at automotive stores) 4 putty knife Acetone

INSTALLATION INSTRUCTIONS FOR SOLID DOUBLEWALL TANK SUMPS

INSTRUCTIONS FOR ABOVE GROUND RETROFIT RS-VRC-R

Flexible Entry Boot Manual Product Manual * Publication Number: EBM-0001 * Issue Date: 07/29/11 Supercedes: 05/27/09

Installation Instructions

Perry Fiberglass Products, Inc. LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

Fiberglass Dispenser Sump

SECTION RESILIENT SHEET FLOORING

Royal Corinthian, Inc. FRP COLUMN COVER INSTALLATION INSTRUCTIONS

Installation Instructions

Perry Fiberglass Products, Inc. LEADERS IN FIBERGLASS REINFORCED PLASTIC PIPE PRODUCTS

1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets

Protective Industrial Polymers - USA Manufacturer s Specification February 11, 2015

Maintenance of Wood, Plastics and Composites. Wood Restoration

Double Wall Fiberglass Sumps

SINGLE-WALL TANK SUMPS INSTALLATION INSTRUCTIONS & OPERATING GUIDELINES

INSTALLATION INSTRUCTIONS

FIVE STAR PRODUCTS, INC. (800)

Installation Instructions

Strength Max User Guide

ENGINEERING SPECIFICATION. PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC. October 25, 2004 Revision 1

ReflectiClean Acrylic/Urethane

Acrylic/Urethane. Metal Roof Restoration Sample Design Guideline

Multi-Piece Shower with Trench Drain

Armor Plate 360 MP ( Multi-Purpose ) Pipe Wrap For External Corrosion and Mechanical Damage

Multi-Piece Shower with Trench Drain

SECTION 39 - MANHOLES TABLE OF CONTENTS

ACRYLIC SPA GRANITE/QUARITE REPAIR

POLYMER CONCRETE 800 NON-SHRINK VINYL ESTER POLYMER CONCRETE, CONCENTRATED HYDROFLUORIC ACID RESISTANCE

Infinity - Century Combination Installation Instructions Gelcoat & Solid Surface Bathware

The World s Leading UST and AST Containment Leak Repair Products

Wabo FireShield Model: FSH

GROUND MOUNT INSTALLATION MANUAL

Application Guide GARAGE & COMMERCIAL FLOORS

Proposed specification - For review by qualified architects and engineers.

IMTECH ADHESIVE SYSTEMS

Dutchman Repair For Limestone. Proposed Specification For Review by Qualified Architects and Engineers

Instructions for On-Site Coating of Vinyl Windows

DUAL-MIX STRUCTURAL IMPACT RESISTANT ADHESIVE TECHNICAL DATA SHEET

ENGINEERING SPECIFICATION

CIRRUS AIRPLANE MAINTENANCE MANUAL

SINK SPECIFICATIONS. SINGLE BOWL Farmhouse Model VGRA3618CS

ENGINEERING SPECIFICATION FIBERGRATE 1 INCH DEEP MICRO-MESH MOLDED GRATING SECTION 06610

INSTALLATION MANUAL RECTANGULAR COLUMN

The World s Leading UST and AST Containment Leak Repair Products

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION PENETRATION FIRESTOPPING PART 1- GENERAL PART 2- PRODUCTS 1.1 RELATED DOCUMENTS

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS

Application Guidelines for PPC Coatings Flooring

LAHAINA. Lahaina Showerspa Model #1030 Installation Instructions

3 Scotch-Weld. Control Joint Sealant DP-5106, Self-Leveling, Gray. Technical Data July, 2006

SHEP POXY ROADS & HIGHWAYS FAST SET HIGH MODULUS, STRUCTURAL, EPOXY GEL

Fast Gel Epoxy. Product Description. General Uses & Applications. Advantages & Features

FIBERGLASS TANK SUMPS

To Contact PS DOORS:

Installation Manual SELT6032-WH SERT6032-WH SELC6032-WH SERC6032-WH

INSTALLATION INSTRUCTIONS

VHB Tapes. Design Guide for Sign Assembly. Proven worldwide. Now even more versatile for more sign applications, more surfaces.

Filament Wound Architectural Columns: Blending Tradition with Technology

APPENDIX A MEASUREMENT AND PAYMENT

COMPOSITES LAB MANUAL

Multiport Spill Containment

Armor Plate Pipe Wrap

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )

Shower Waterproofing Membrane Under tile and wet area waterproofing membrane.

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware

DLB-23 Shower Enclosure Installation and User s guide

Installation Instructions

Elavo White Ceramic Round Vessel Bathroom Sink

SINGLE SWING DOOR PAIRED SWING DOOR

STERI-FLAKE 470 HYBRID ESTER POLYMER, LIGHT-MEDIUM TRAFFIC, FLAKE FILLED FLOOR SYSTEM LOW ODOR MMA ALTERNATIVE FEATURES

S8-390 & S INSTALLATION INSTRUCTIONS

***************************************************************************************************************

Construction. Sikadur 31, Hi-Mod Gel. Application Instructions. Sika Corporation

Low-Profile Multi-Piece Shower with blue, high-density polyurethane bottom

Installation Instructions

Technical Data Sheet EpoGlass PU Code: 65

Tank Sump Manual. Product Manual * Publication Number: TSM-0001 * Issue Date: 05/27/09 Supercedes: 11/01/07

Epoxy & Pebblestone Fax: We ship all over the USA U.V.

POLYMER CONCRETE 100 EPOXY POLYMER CONCRETE DILUTE ACIDS RESISTANCE

Multi-Piece Shower with Trench Drain

Distributed by: BEST MATERIALS Ph: , Fax:

SECTION 07530CP EPDM MEMBRANE ROOFING

BROADCAST KITCHEN FLOORING SYSTEM

Transcription:

RETROFIT-SD-AB INSTALLATION INSTRUCTIONS BRAVO FIBERGLASS RETROFIT-SD-AB SERIES FOR DOUBLE WALL FRP SUMPS FOR RETROFITTING DOUBLEWALL ENTRY BOOTS FIBERGLASS PIPE OR GALVANIZED CONDUIT ONLY For Conduit F-05 / 07 / 10-Retrofit-SD-AB For Fiberglass Pipe - Flat Wall F-20 / 30 / 40-Retrofit-SD-AB For Fiberglass Pipe - Round Wall F-20 / 30 / 40-Retrofit-SD-AB-RND For LCX Fiberglass Pipe - Flat Wall F-20 / 30 / 40-Retrofit-SD-AB-LCX For LCX Fiberglass Pipe - Round Wall F-20 / 30 / 40-Retrofit-SD-AB-LCX-RND BUILT LIKE A TANK High-end materials match UST spec UL1316 to ensure longevity and fuel compatibility WWW.SBRAVO.COM/FS READ THIS MANUAL FRONT TO BACK Note: Actual products may vary in appearance from illustrations in this manual 1 ii-f-series-retrofit-sd-ab-12a S. Bravo Systems, Inc. - The Leader in Secondary Containment 2929 Vail Ave. Commerce, CA 323-888-4133 FAX: 323-888-4123 www.sbravo.com 12A

The F-Series Doublewall Retrofit-S AB-2481 Fittings from S. Bravo Systems, Inc. MUST be installed by a Bravo Retrofit-Certified Installer. The Retrofit Test must be completed at www.sbravo.com/cert You must also be Confined-Space Certified when working within Tank Sumps. KEEP TRACK of your job by taking advantage of the Complete checkboxes paired with each major step. OUTSIDE INSIDE TABLE OF CONTENTS Fitting Warnings, Requirements & Warranty Terms... p. 3 Fitting / Wedge Specifications and part numbers... p. 4 Fitting Components and Tools... p. 5 INSTALLATION SUMMARY... p. 6 Step 1 Excavating and sump preparation...p. 7 Step 2 Removing the existing boot... p. 8 Step 3 Wrapping pipe with rubber strip and surface preparation... p. 8 Step 4 Dry-Fitting and marking for alignment... p. 8 PREPARING YOUR PIPE BY HAND SANDING... p. 9 MIXING YOUR ADHESIVE - CRITICAL STEP... p. 10 Step 5 Gluing and Installing angle flange to wall on OUTSIDE... p. 11 Step 6 Gluing and Installing fitting body to angle flange... p. 12 Step 7 Gluing, Aligning and clamping fitting body halves together...p. 13 Step 8 Securing fitting to wall via clamp and beading adhesive... p. 13 Step 9 Gluing and Installing angle flange to wall on INSIDE...p. 14 Step 10 Gluing and Installing fitting body to angle flange... p. 15 Step 11 Gluing, Aligning and clamping fitting body halves together... p. 16 Step 12 Securing fitting to wall via clamp and beading adhesive... p. 16 Step 13 FINAL MANDATORY TESTING DIRECTIONS... p. 17 OUTSIDE INSIDE If you have any problems with Bravo Systems components or accessories, Contact Bravo Systems Immediately: 1-800-28-BRAVO 1-323-888-4133 support@sbravo.com LIMITED WARRANTY Products sold by S. Bravo Systems, Inc. are warranted to be free from defects in material and workmanship for a period of one year from date of purchase. This warranty will be limited to the repair and replacement of Bravo parts only and will exclude all claims for labor or consequential damage. No other express warranties are given and no affirmation of S. Bravo Systems, Inc., or its agents and/or representatives, by words or action, will constitute a warranty. IT IS EXPRESSLY AGREED THAT THIS WARRANTY WILL BE IN LIEU OF ALL WARRANTIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY. This warranty is void if there is any evidence of modification, abuse, negligence, or improper installation - including but not limited to installation or maintenance by a Non-Specialist Certified individual. If any fittings or components, other than S. Bravo Systems approved fittings or components, are used in conjunction with any S. Bravo Systems product, the warranty pertaining to these products is immediately void. 2 ii-f-series-retrofit-sd-ab-12a

VENTILATE YOUR AREA WEAR MASK, SAFETY GLASSES, GLOVES AND OTHER PROTECTION NO > > ELECTRIC TOOLS IGNITION SOURCES Ensure that the workspace is operating below the LEL (lower explosive limit). Test regularly or monitor continuously. WARRANTY IS VOID OR YOUR CERTIFIED STATUS WILL BE REVOKED: IF ANY OF THE FOLLOWING OCCUR A) NOT Installing an F-Series Retrofit-SD-AB fitting with Bravo ADHESIVE-RETROFIT-EPOXY-KIT. B) Installing an F-Series Retrofit-SD-AB fitting with adhesives that are not specified in this manual. C) F-Series Retrofit-SD-AB Fittings are NOT installed by a Bravo Certified Contractor. D) Installing an F-Series Retrofit-SD-AB fitting on Polyethylene sumps or flex pipe. E) Installing an F-Series Retrofit-SD-AB fitting without monitoring lower explosive limit. 3 ii-f-series-retrofit-sd-ab-12a

FITTING SPECS Model Number Wall type Pipe type and size O.D. Length Bravo Adhesive Kits Included F-05-Retrofit-SD-AB Flat 1/2 Conduit 7 ø 6 2 F-07-Retrofit-SD-AB Flat 3/4 Conduit 7 ø 6 2 F-10-Retrofit-SD-AB Flat 1 Conduit 7 ø 6 2 F-20-Retrofit-SD-AB Flat 2 Fiberglass 7-1/2 ø 6 2 F-30-Retrofit-SD-AB Flat 3 Fiberglass 7-1/2 ø 6 2 F-40-Retrofit-SD-AB Flat 4 Fiberglass 9 ø 9 2 F-05-Retrofit-SD-AB-RND Round 1/2 Conduit 7 ø 8 3 F-07-Retrofit-SD-AB-RND Round 3/4 Conduit 7 ø 8 3 F-10-Retrofit-SD-AB-RND Round 1 Conduit 7 ø 8 3 F-20-Retrofit-SD-AB-RND Round 2 Fiberglass 8 ø 8 3 F-30-Retrofit-SD-AB-RND Round 3 Fiberglass 8 ø 8 3 F-40-Retrofit-SD-AB-RND Round 4 Fiberglass 11 ø 11 3 F-20-Retrofit-SD-AB-LCX Flat 2 Ameron LCX 8 ø 6 2 F-30-Retrofit-SD-AB-LCX Flat 3 Ameron LCX 8 ø 6 2 F-20-Retrofit-SD-AB-LCX-RND Round 2 Ameron LCX 8 ø 8 3 F-30-Retrofit-SD-AB-LCX-RND Round 3 Ameron LCX 8 ø 8 3 ADD-ON WEDGE SPECS EACH ADD-ON WEDGE REQUIRES ONE (1) BRAVO ADHESIVE-EPOXY-RETROFIT-KIT TO BE ORDERED Model Number Angle Gain Designed for Wedge O.D. Wedge Length F-10-Retrofit-5wedge-D 5 Deg. 1/2 thru 1 Conduit 5 ø 1 F-10-Retrofit-10wedge-D 10 Deg. 1/2 thru 1 Conduit 5 ø 1-1/2 F-30-Retrofit-5wedge-D 5 Deg. 2 and 3 Fiberglass 7-1/2 ø 1-1/4 F-30-Retrofit-10wedge-D 10 Deg. 2 and 3 Fiberglass 7-1/2 ø 1-3/4 F-40-Retrofit-5wedge-D 5 Deg. 4 Fiberglass & LCX 8-1/2 ø 1-1/4 F-40-Retrofit-10wedge-D 10 Deg. 4 Fiberglass & LCX 8-1/2 ø 1-3/4 4 ii-f-series-retrofit-sd-ab-12a

F-Series Retrofit-SD-AB COMPONENTS Included Parts (Per fitting) A) 2x Fiberglass Retrofit-S Body (two halves) with SS Pipe Clamp B) 2x Loose Fiberglass Angle Flange (two halves) with 2 Zip-Ties C) Bravo ADHESIVE-RETROFIT-EPOXY-KIT: (quantity chart on page 4) 1x Bravo Epoxy Adhesive Can 6oz 1x Bravo Epoxy Catalyst bottle 1oz 2x Pair of Industrial Nitrile gloves (Large) 1x Stir stick 1x 1 chip brush D) 1x 60 grit emery cloth strip E) 1x 80 grit sheet of sandpaper F) 2x 3-bolt compression clamp G) 1x 15 long Rubber Strip H) 1x Angle measuring tool (Protractor) REQUIRED TOOLS (NOT PROVIDED) Air Sander and Air Drill Steel Stator Mixer Eye protection Respiratory protection Approved Bonding Adhesive: Bravo ADHESIVE-RETROFIT-EPOXY-KIT A Confined-space Certification is required when installing this fitting inside Tank Sumps USE ONLY BRAVO SYSTEMS ADHESIVE WHEN INSTALLING THIS FITTING TO FIBERGLASS PIPE OR CONDUIT DO NOT SUBSTITUTE ADHESIVES, MIX THEM OR ADD LIQUIDS SUCH AS WATER OR ANOTHER RESIN. DO NOT USE ANOTHER CATALYST OTHER THAN WHAT IS PROVIDED. 5 ii-f-series-retrofit-sd-ab-12a

Summary of Installation These steps are not a substitute for the detailed installation steps contained in the following pages. DO NOT ATTEMPT TO INSTALL THIS PRODUCT BASED ONLY ON THE SUMMARIZED STEPS LISTED ON THIS PAGE 1) Remove any necessary components that will obstruct your access to the sump wall. Excavate adequate area on outside of all fittings you will install. 2) Clean each sump. Remove all contaminants, water and debris. 3) Ensure each sump will be completely dry during all installation steps. 4) Drain all fluid from the sump interstice. 5) Flush interstice with water and dry out completely. 6) Remove the entire boot and all of it s components or sealants from the wall. 7) Protect the pipe or conduit with the provided rubber strip. 8) Clean, dry and abrade sump walls around hole until bare fiberglass is shown. 9) Clean, dry and rough up pipe or conduit surface in preparation for gluing. 10) Secure conduits by bracing to the riser or other conduits. 11) Dry-fit fittings for correct fit and mark an alignment stripe across all parts. 12) Mix adhesive thoroughly first until color is visibly mixed. Then catalyze. 13) Glue angle flange to outside of sump, keeping marked stripe aligned. 14) Glue and assemble fitting body to flange, keeping marked stripe aligned. 15) Clamp full fitting assembly firmly to the sump with provided 3-prong clamp. 16) Shape a heavy bead of adhesive on every joint and seam. 17) Repeat steps 7-15 to install fitting to the inside of the sump. 18) Mandatory Pressure/soap test to verify the Fitting installation is good. 19) Mandatory Extended Vacuum test to verify the sump itself is not leaking. 6 ii-f-series-retrofit-sd-ab-12a

VENTILATE YOUR AREA WEAR MASK, SAFETY GLASSES, GLOVES AND OTHER PROTECTION NO > > ELECTRIC TOOLS IGNITION SOURCES Ensure that the workspace is operating below the LEL (lower explosive limit) before starting work. Test regularly or monitor continuously A Confined-space Certification is required when installing this fitting inside Tank Sumps STEP 1 FOLLOW THESE STEPS IN ORDER DONE DONE DONE DONE DONE DONE DONE DONE A) Excavate to gain access to all fittings on each sump. B) Remove any components that will obstruct access to the fittings. C) Clean interior and bottom of each sump. Remove contaminants, water and debris. Dispose of HAZMAT per local codes. D) Ensure each sump will be completely dry during installation. E) Drain fluid from the interstice and dispose. DO NOT REUSE. F) Flush interstice with plain water. G) Air-dry the interstice so that no water or moisture is present near the hole-saw area. No water may interfere with the glue. H) After sump has been drained, flushed with water and dried out, proceed to Step 2. 7 ii-f-series-retrofit-sd-ab-12a

STEP 2 EXTERIOR BOOT DOUBLE WALL INTERIOR BOOT Remove boot from the wall with all components, bolts and sealants. DO NOT USE TOOLS THAT CAN DAMAGE THE PIPE OR CONDUIT. Use the Bravo Angle Measurement tool if you need to check pipe angles STEP 3 ABRADE pipe wrapped with provided rubber strip Before starting work, ensure all fuels and flammbles have been removed. Test/monitor your LEL s and ventilate. STARTING ON THE OUTSIDE OF SUMP Wrap the provided rubber strip around your pipe or conduit. Secure with zip-tie or strong tape. Proceed to grind your walls clean of any paint, gel-coat, adhesives or sealants until open fiberglass is clearly visible 3 INCHES AWAY FROM THE HOLE. STEP 4 STRIPE MARK mark across the wall and all components DRY FIT ONLY STABILIZE YOUR CONDUITS BY BRACKETING OR SECURING TO EITHER THE RISER OR OTHER CONDUITS. DO NOT SECURE TO ANY OTHER COMPONENTS Dry fit both the angled flange and the body to the pipe to determine the best orientation that will evenly contact the pipe and the wall with the least amount of play. Use a permanent marker to mark a large stripe across the sump wall and all of the assembled parts in one place. 8 ii-f-series-retrofit-sd-ab-12a

ROUGHING-UP YOUR FRP PIPE WITH SAND STRIP DO NOT USE ANY POWER TOOLS ON PIPE, EVER! Your pipe must be hand roughed in preparation for Gluing DO NOT USE ANY POWER TOOLS ON PIPE, EVER! 9 ii-f-series-retrofit-sd-ab-12a

MIXING YOUR ADHESIVE Your adhesive should be stored in a cool place until ready to be mixed. You should warm your adhesive and fiberglass fitting components if the ambient temperature is below 70 F. DO NOT MIX MORE THAN ONE CAN AT A TIME DO NOT ATTEMPT TO MIX HALF A CAN ONLY USE 1 BOTTLE OF CATALYST PER ADHESIVE CAN USE ONLY BRAVO SYSTEMS ADHESIVE WHEN INSTALLING THIS FITTING TO FIBERGLASS PIPE OR CONDUIT DO NOT SUBSTITUTE ADHESIVES, MIX THEM OR ADD LIQUIDS SUCH AS WATER OR ANOTHER RESIN. DO NOT USE ANOTHER CATALYST OTHER THAN WHAT IS PROVIDED. ADHESIVE HAS AN ACTIVE COLORANT ADD CATALYST TO ADHESIVE AND MIX THOROUGHLY UNTIL THE COLOR IS EVEN AND CONSISTENT WITH NO SWIRLS - NOT MIXED - NOT MIXED NOT MIXED - NOT MIXED - NOT MIXED - - THOROUGHLY MIXED THOROUGHLY MIXED THOROUGHLY MIXED - 10 ii-f-series-retrofit-sd-ab-12a -

CAUTION WINTER WARNING FOR COLD WEATHER AT 50 F DEGREES OR LESS: OBSERVE AND FOLLOW THE WARNINGS BELOW BRAVO SYSTEMS FF-SERIES FLANGE FITTINGS AND F-SERIES FITTINGS ARE THICKER THAN THE TYPICAL FIBERGLASS CLAMSHELLS COMMONLY INSTALLED IN FIBERGLASS PIPING APPLICATIONS. YOU MUST APPLY ADEQUATE HEAT TO THE PARTS AND BONDING ADHESIVES TO ALLOW A FULL CURE TIME DURING EXTREME COLD TEMPERATURES. FAILING TO ALLOW THE INSTALLATION TO FULLY CURE MAY CAUSE THE ADHESIVE BOND TO THE FITTING TO FAIL. JUST BEFORE EACH ADHESIVE APPLICATION DRY FIT YOUR COMPONENTS ONE LAST TIME 1) PRE-HEAT THE SUMP TO NO MORE THAN 150 F TO ELIMINATE MOISTURE. 2) PRE-HEATING COMPONENTS IN EXTREME COLD WEATHER IS CRITICAL: > PRE-HEAT THE FIBERGLASS FITTING THOROUGHLY TO ~100 F > PRE-HEAT THE ADHESIVE TO ~80 F. DO NOT HEAT CATALYST!! 3) DO NOT ASSUME THE ADHESIVE IS CURED BECAUSE IT HAS HARDENED ON THE EXTERIOR. IT MAY ONLY BE A CURED CRUST IN THIS TEMPERATURE AND ANY MOVEMENT OR WATER TESTING MAY CAUSE DELAMINATION AND TOTAL FAILURE OF THE BOND. 4) DO NOT ADJUST, MOVE, SHIFT OR OTHERWISE DISTURB THE SUMP, FITTINGS OR PIPING DURING THE CURING PROCESS. 5) YOU MUST ENSURE A FULL CURE BEFORE WATER TESTING. FOLLOW YOUR ADHESIVE INSTRUCTIONS FOR TEMPERATURE GUIDELINES.

STEP 5 ADHESIVE APPLIED TO ALL CONTACT SURFACES ZIP-TIE ANGLE FLANGE MARKED STRIPE INTERIOR OF SUMP DO NOT FORGET TO BOND THE CONTACT SURFACES BETWEEN ANGLE HALVES GLUE ANGLE FLANGE TO THE OUTSIDE FIRST Apply your mixed Bravo adhesive to all Contact Surfaces; between both halves of the first angle flange where they contact each other, the pipe, the wall, and the face of the angle flange that will contact the wall. Use provided zip-tie to lock these halves together tightly. Stick this assembly to the wall by applying a slight pressure. You must also align the marked stripe in this step. In weather below 90 F this should remain in place without any assistance while you prepare the body for gluing. USE ONLY BRAVO SYSTEMS ADHESIVE WHEN INSTALLING THIS FITTING TO FIBERGLASS PIPE OR CONDUIT DO NOT SUBSTITUTE ADHESIVES, MIX THEM OR ADD LIQUIDS SUCH AS WATER OR ANOTHER RESIN. DO NOT USE ANOTHER CATALYST OTHER THAN WHAT IS PROVIDED. 11 ii-f-series-retrofit-sd-ab-12a

STEP 6 ADHESIVE APPLIED TO ALL CONTACT SURFACES FITTING BODY With the same paste, apply generously to all contact surfaces; the flange on the wall, pipe, interior of the fitting body, the surfaces of the fitting halves that will meet each other, and the face of the body that will contact the angle flange already on the wall. Be generous on the interior, this is an area where a large amount of adhesive is critical. ADHESIVE SHOULD BE APPLIED TO ALL CONTACT SURFACES! USE ONLY BRAVO SYSTEMS ADHESIVE WHEN INSTALLING THIS FITTING TO FIBERGLASS PIPE OR CONDUIT DO NOT SUBSTITUTE ADHESIVES, MIX THEM OR ADD LIQUIDS SUCH AS WATER OR ANOTHER RESIN. DO NOT USE ANOTHER CATALYST OTHER THAN WHAT IS PROVIDED. 12 ii-f-series-retrofit-sd-ab-12a

STEP 7 STRIPE MARK ROTATE YOUR FITTING COMPONENTS TO ALIGN THE STRIPE Assemble the two halves of the body -aligning the marked stripewith the stainless steel pipe clamp provided for the body. Tighten well and make sure the marked stripe is aligned correctly. PIPE CLAMP SEAL YOUR FITTING BODY TOGETHER Adhesive should ooze from the seams between the two halves. DO NOT REMOVE EXCESS ADHESIVE KEEP IT ON THE FITTING STEP 8 BEAD ADHESIVE USE ALL EXCESS ADHESIVE BY BEADING IT ON ALL SEAMS Use provided clamp to hold the assembly against the wall while it cures. First clamp to the pipe, then turn each bolt until they press against the fitting evenly. Bead adhesive generously so it is visibly built up on all joints. Do not use a paint brush to brush seams clean. CLAMP THE FITTING SECURELY TO THE WALL WHILE THE ADHESIVE CURES It is OK to coat the zip-tie(s) and the SS Pipe Clamp. Make sure that the seams between all halves are coated generously. CURE IT After a full cure, remove the 3-bolt clamp that holds the fitting to the wall.!! DO NOT REMOVE EXCESS ADHESIVE!! Continue to build up the adhesive around every seam. The goal is to not remove any adhesive or allow it to fall. 13 ii-f-series-retrofit-sd-ab-12a

STEP 9 AFTER ALL GLUED FITTINGS HAVE CURED NOW REPEAT OPERATIONS ON THE INSIDE EXTERIOR OF SUMP ADHESIVE APPLIED TO ALL CONTACT SURFACES ZIP-TIE ANGLE FLANGE MARKED STRIPE DO NOT FORGET TO BOND THE CONTACT SURFACES BETWEEN ANGLE HALVES Apply your mixed Bravo adhesive to all Contact Surfaces; between both halves of the first angle flange where they contact each other, the pipe, the wall, and the face of the angle flange that will contact the wall. Use provided zip-tie to lock these halves together tightly. Stick this assembly to the wall by applying a slight pressure. You must also align the marked stripe in this step. In weather below 90 F this should remain in place without any assistance while you prepare the body for gluing. USE ONLY BRAVO SYSTEMS ADHESIVE WHEN INSTALLING THIS FITTING TO FIBERGLASS PIPE OR CONDUIT DO NOT SUBSTITUTE ADHESIVES, MIX THEM OR ADD LIQUIDS SUCH AS WATER OR ANOTHER RESIN. DO NOT USE ANOTHER CATALYST OTHER THAN WHAT IS PROVIDED. 14 ii-f-series-retrofit-sd-ab-12a

STEP 10 ADHESIVE APPLIED TO ALL CONTACT SURFACES FITTING BODY With the same paste, apply generously to all contact surfaces; the flange on the wall, pipe, interior of the fitting body, the surfaces of the fitting halves that will meet each other, and the face of the body that will contact the angle flange already on the wall. Be generous on the interior, this is an area where a large amount of adhesive is critical. ADHESIVE SHOULD BE APPLIED TO ALL CONTACT SURFACES! USE ONLY BRAVO SYSTEMS ADHESIVE WHEN INSTALLING THIS FITTING TO FIBERGLASS PIPE OR CONDUIT DO NOT SUBSTITUTE ADHESIVES, MIX THEM OR ADD LIQUIDS SUCH AS WATER OR ANOTHER RESIN. DO NOT USE ANOTHER CATALYST OTHER THAN WHAT IS PROVIDED. 15 ii-f-series-retrofit-sd-ab-12a

STEP 11 STRIPE MARK ROTATE YOUR FITTING COMPONENTS TO MAINTAIN THE STRIPE Assemble the two halves of the body -aligning the marked stripe with the stainless steel pipe clamp provided for the body. Tighten well and make sure the marked stripe is aligned correctly. PIPE CLAMP SEAL YOUR FITTING BODY TOGETHER Adhesive should ooze from the seams between the two halves. DO NOT REMOVE EXCESS ADHESIVE KEEP IT ON THE FITTING STEP 12 BEAD ADHESIVE USE ALL EXCESS ADHESIVE BY BEADING IT ON ALL SEAMS CLAMP THE FITTING SECURELY TO THE WALL WHILE THE ADHESIVE CURES Use provided clamp to hold the assembly against the wall while it cures. First clamp to the pipe, then turn each bolt until they press against the fitting evenly. Bead adhesive generously so it is visibly built up on all joints. Do not use a paint brush to brush seams clean. It is OK to coat the zip-tie(s) and the SS Pipe Clamp. Make sure that the seams between all halves are coated generously. CLEAN UP: You can use acetone to clean up the adhesive while it is wet to create a clean and picture perfect install. ALLOW A FULL CURE PER THE INSTRUCTIONS ON THE ADHESIVE CAN. After a full cure, remove the 3-bolt clamp and re-apply adhesive where necessary. 16 ii-f-series-retrofit-sd-ab-12a

FINAL STEP - STEP 13 MANDATORY PRESSURE TESTING: To test your complete fitting installation after a full adhesive cure time of 4 hours minimum at 75 F or greater, conduct a pressure/soap test on all fittings, inside and outside at all critical joints. Bravo Systems DoubleWall Containment Sump: Maximum 4 PSI and minimum 20 hg Vacuum. Other Manufacturer s Containment Sump & fittings: Follow manufacturers guidelines RECOMMENDED EXTENDED VACUUM TESTING: The ALDP Test is highly recommended only on Bravo Systems DoubleWall Tank Sumps. You can find this procedure outlined in any Bravo DoubleWall manual. Visit www.sbravo.com/install for a list of instruction manuals to choose from. This testing procedure should be used when a sump leak is suspected or cannot be found by pressure/soap testing. The ALDP test can help you pinpoint any leaks you may have so you can quickly address them. For Bravo Systems DoubleWall Sumps which are gel-coated white on the interior (pre-2006): A vacuum test is not recommended. Follow the mandatory pressure testing guidelines above. FOR OTHER MANUFACTURERS SUMPS: A vacuum test is not recommended, as no other manufacturer has transparent sump walls, making the ALDP procedure and subsequent visual inspection nearly impossible. If you would like to attempt a vacuum test, consult your sump manufacturers installation/maintenance manual for directions on vacuum and pressure testing. The final installation might not look pretty, but it will not fail you Install with Confidecnce Compatible when submerged in fuels, biofuels and alcohol blends up to E100 and B100 WWW. SBRAVO. COM/ FS 17 ii-f-series-retrofit-sd-ab-12a