EURL-SRM - Analytical Observations Report

Similar documents
Analytical Method of Limit Test for Hexachlorobenzene. in Picloram TC and Method Validation Data*

DETERMINATION OF ORGANIC PRIORITY POLLUTANTS AND EMERGING COMPOUNDS IN WASTEWATER BY MICRO SOLID PHASE EXTRACTION COUPLED TO GCMS

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

2.1 This procedure provides steps and conditions for the determination of Vapor Space Organic Compounds in ground waters, and industrial waste waters.

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE.

Corn Syrup Analysis E-1a- 1. ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Application Note: Multi-Residue Pesticides in Fruit and Vegetables (9/16/08)

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

ACETALDEHYDE. The procedure is applicable to corn syrups including those containing fructose, and to most other starch hydrolyzates (Note 1).

ANILINE, o-toluidine, AND NITROBENZENE 2017

Method of determination of phthalates by gas chromatography / mass spectrometry in wines

CHROMATOGRAPHY/MASS SPECTROMETRY

Validation Data for the Analysis of Chlorotalonil in Leek Using Mini-Luke Method Followed by GC-QqQ-MS/MS

CORESTA Recommended Method No. 57

Capillary GC Troubleshooting: a Practical Approach

AppNote 6/2000 KEYWORDS ABSTRACT. Headspace, Solid Phase Microextraction, SPME, Thermal Desorption, Herbs, Coffee, Tea, Polyethylene

Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing

Test Sampling Matrix Location Treatment Samples

CryoTrap. For Agilent Technologies 7890/6890/6850 GC Systems. CryoTrap

Formulas: See Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1. METHOD: 2555, Issue 1 EVALUATION: PARTIAL Issue 1: 15 March 2003

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Determination of Table 3 Compounds by LC/MS/MS Chemours Fluoroproducts Analytical Method Revision date: 4/26/2018

Analysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool

C146-E096 TD-20. Shimadzu Thermal Desorption System

Evaluation by Competent Authorities

Two Headspace Solutions for the Analysis of Dissolved Gases in Water by Method RSKSOP-175

Determination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Atlantic HLB SPE Disks

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

MERCAPTANS, METHYL-, ETHYL-, and n-butyl- 2542

Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP1 and DB-CLP2

Agilent Consumables Improve Performance with Shimadzu GC/MS

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

NWTPH-Gx. Volatile Petroleum Products Method for Soil and Water

JAI RESEARCH FOUNDATION A Global Contract Research Organisation

Analysis of styrene leached from polystyrene cups using GCMS coupled with Headspace (HS) sampler

Determination of 1,4-Dioxane in Drinking Water by Gas Chromatography/Mass Spectrometry (GC/MS) with Selected Ion Monitoring (SIM)

Field Analytical Method Development for C 6 -C 9 Range Hydrocarbon Measurement

Nitrosamines Analysis in Drinking Water Using GC/MS/MS Meeting Equivalence to EPA Method 521

Standard Operation Procedure (SOP) for the Extraction and Instrument Analysis of Siloxanes from Cartridges

Volatile Organic Carbon Contaminated Site Assessment

Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene

METHOD TRANSLATION OF HJ FOR INTUVO

Pesticide Analysis in a Complex Matrix using a 2D GC/MS System

Methods for determination of mercury in LP gas

TurboMatrix Headspace and Headspace Trap Samplers

METHOD 310A - DETERMINATION OF RESIDUAL HEXANE THROUGH GAS CHROMATOGRAPHY

Partly O-(2-hydroxyethylated) cellulose. It may contain suitable ph-stabilisers such as phosphates.

Certified Reference Material - Certificate of Analysis

Reduced carryover and increased reproducibility in the analysis of cold pressed pink grapefruit essential oil

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Analytical Method for aldrin, endrin and dieldrin (Targeted to Agricultural, Animal and Fishery Products)

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

HYDROCARBONS, BP C 1500

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

Low-level Detection of Ethanol, 1,4-Dioxane, and Other Oxygenates Using the Eclipse Purge-and-Trap Sample Concentrator

Multiresidue Pesticide Analysis with the Agilent Intuvo 9000 GC and Agilent 7000 Series Mass Spectrometer

Ghost Peaks in Gas Chromatography Part 2: The Injection Port

Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD. Application. Author. Abstract. Instrument Operating Parameters.

Gas Chromatography Assignment Chem 543/443

Methods for Increased Sample Throughput with Dirty Samples

Updating Solid Phase Extraction Methods: Tips and Tricks for Improving Existing and New SPE Methods using Method Development

INTERDISCIPLINARY INVESTIGATION (IDI)-LAB LABORATORY HANDOUT

Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing. Application. Author.

CORESTA Recommended Method No. 63

Validated Multi-Residue Method for Extraction and Analysis of Trace-Level Pesticides in Surface Water Application

A New Horizon of Performance Agilent G1888 Network Headspace Sampler

Certified Reference Material - Certificate of Analysis

SpeedExtractor E-916 Determination of Total Petroleum Hydrocarbons in Soil, Sediment, and Waste Samples using the SpeedExtractor E /2009

CTC automated sample injectors for gas chromatography, distributed by Agilent Technologies

Sample Matrix Influence on GC/MS/MS Multiresidue Pesticide Analysis

HYDROGEN AS A CARRIER GAS. Gas Chromatography new frontiers: can Hydrogen substitute Helium?

When optimization is discussed throughout this talk, it s in terms of performing more samples, in less time, while minimizing investment in capital

GC Method Development

Application Note. Abstract. Authors. Food Safety

Certified Reference Material - Certificate of Analysis

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace

US EPA Method Atomx XYZ and Agilent 7890B GC/5977A MS

Certified Reference Material - Certificate of Analysis

Interlaboratory Validation Study for the Analysis of Nitrosamines in Drinking Water using GC-MS/MS

Certified Reference Material - Certificate of Analysis

Course Outline. in Soil/Sediment&WasteSediment&Waste by. Overview of VOCs Analysis Sample Collection VOCs Analysis

Large Volume Injection of Organochlorine Pesticide Extracts Using a Programmable Temperature Vaporizer in the Solvent Split Mode

The Use Of Automated Backflush on the 7890A/5975A GC-MS System. Application. Setup Example Using Biomarkers. Authors. Abstract.

Evaluating Inert Flow Path Components and Entire Flow Path for GC/MS/MS Pesticide Analysis

Improving Chromatographic Performance of Underivatised Anionic Polar Pesticides in Food to Overcome Renowned Analytical Challenges

THIOPHANATE-METHYL in air 5606

ITSP Extraction of Cortisol from Plasma

Certified Reference Material - Certificate of Analysis

ENVIRONMENTAL CHEMICAL ANALYSIS III

Certified Reference Material - Certificate of Analysis

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

Validation Report 19

Method Development for Rapid Extraction of Volatile Organic Compounds from Rock Samples Using Microwave Assisted Extraction

Automated Solid Phase Extraction of PAH Compounds Utilizing the SPE-DEX 5000

An Examination of the Presence, Formation, and Transformation of Volatile Halogenated Organic Species in Wastewater Extracts Using GC-ICP-MS

Transcription:

concerning the following EURL-SRM - Analytical Observations Report o Compound(s): Sulfuryl fluoride o Commodities: cereals, nuts, pulses and other dry materials o Extraction Method(s): none o Instrumental analysis: Headspace-GC/MS Analysis of the Fumigant Sulfuryl Fluoride Applying Headspace-GC-MSD Version 1 (last update: March 2018) Background information / Initial Observations: Sulfuryl fluoride was introduced in the 1950s as a fumigant for the control of insect pests in wood especially termites. It has also been used to control rodents. Following the Montreal agreement and the resulting decrease in the use of methyl bromide sulfurid fluorid has become more important substitute. Sulfurid fluorid is furthermore considered as an alternative to phosphine, which is more critical in terms of acute toxicity. It is mainly used to fumigate buildings, shipping containers, ships and wood products. Food applications of sulfuryl fluoride include the fumigation of dried fruit, tree nuts, dry pulses as well as cereals. It is also used to treat empty storage rooms, silos and grain processing facilities. In the EU residues resulting from applications of sulfuryl fluoride are regulated either via an MRL for sulfuryl fluoride as well as via an MRL for fluoride, which is formed when sulfluryl fluoride decomposes. Fluoride is thought to be the actual active component as it inhibits the breakdown of fatty acids within the target organisms. Compound details: Sulfuryl Fluoride (CAS: 2699-79-8), IUPAC name: sulfuryl fluoride Parameter Value Molecular Mass Exact mass Form Solubility LogP 102.06 g/mol 101.958708 Da Colorless, odorless gas 1.04 g/l (at 20 C) in water 71 g/l in acetone 0.14 (at 20 C) Hydrolysis (DT50) 6.7 h (ph 7), 4.0 min (ph 9); @ 20 C Boiling point Vapor pressure Residue definition EU Sulfuryl fluoride is approved in ADI ARfD -54 C 1.61 10 6 Pa (20 C) 1) Sulfuryl fluoride: MRLs, e.g. 10 mg/kg in tree nuts, 0.05 mg/kg in herbal infusions, MRL*s = 0.01mg/kg in most commodities and 0.02 in teas, coffee etc. 2) Fluoride ion: MRLs, e.g. 350 mg/kg in teas, 25 mg/kg in tree nuts, 10 mg/kg in herbal infusions and hops as well as 5 mg/kg in coffee beans and spices, MRL* = 2 mg/kg for all commodities of plant origin BE, DE, ES, FR, IE, IT, NL, PT, UK 0.014 mg/kg bw per day (Reg. (EU) 2017/270) / 0.7 mg/kg bw (Reg. (EU) 2017/270) 0.01 mg/kg bw per day / 0.3 mg/kg bw (JMPR 2005) [1]

Chemicals 1 : Substance Purity CAS Source Sulfuryl fluoride in N 2 100 ppm >99.9% 2699-79-8 Linde AG München, Germany Sulfuryl fluoride in N 2 10 ppm >99.9% 2699-79-8 Linde AG München, Germany Sulfuric acid (concentrated) analysis grade Merck, Darmstadt, Germany Aqueous solutions thereof 5% (v/v) and 10% (v/v) are prepared Apparatus Grindomix GM 200 knife mill (Retsch Haan, Germany) Tedlar gas sampling bags (Nr. 24633 Supelco #, Germany) gas tight syringes (PN 1710 100 µl and PN 1001 1000 µl from Hamilton #, Germany) analytical balances capable of weighing to 0.1 mg or to 0.01 g (Mettler-Toledo Greifensee, Switzerland). GC-MSD: Agilent 6890 GC coupled to 5973 MSD (Waldbronn, Germany) manually tuned to achieve high sensitivity in the low mass area, Autosampler: MPS2 sampler (Gerstel Mülheim/Ruhr, Germany) with a head space agitator unit and a 2.5 ml syringe Injection system: KAS 4 PTV with a cryo system at -80 C (liquid nitrogen) Liners: filled with Tenax (Gerstel Mülheim/Ruhr, Germany). Column: Rt-Q-Bond PLOT column (30 m 0.32 mm 10 µm) (Restek Bad Homburg, Germany) connected to a restriction capillary (5 m 0.25 mm) (Agilent Waldbronn, Germany), to prevent single loose particles of the stationary phase from entering the ion source of the MSD Sample Preparation Cereals, pulses or tree nuts are ground with a knife mill. Granular samples: 3g of granular samples (e.g. whole or coarsely milled grains) are weighed in a headspace vial and sulfuric acid 5 % is speedily added up to a level of 15 ml into the vial. Powdery samples: 1 g of the powdery sample is weighed into a head space vial and 7 ml of water are added. Then the vial is closed with a rubber plug and vigorously shaken to ensure that the material is entirely wetted. Subsequently, the vial is opened again, quickly filled up to a 15 ml level with sulfuric acid 10 % by pouring from a small beaker and immediately closed again with a screw cap. In case of a standard addition approach make sure to weigh the same amount of sample in each vial and to add the same amount of sulfuric acid (e.g. 10 ml or 12 ml). In this case there is no need to fillup the vial to a pre-defined level. 1 Disclaimer: Names of companies are given for the convenience of the reader and do not indicate any preference by the EURL-SRM towards these companies and their products [2]

Headspace GC-MS analysis Table 1: Instrumentation details Headspace conditions Agitator temperature 80 C Incubation time 10 min Shaking speed 500 rotations per min Shaking interval 5 s followed by a 2 s break Syringe temperature 85 C Injection volume 2000 µl Draw speed 200 µl/s Injection speed 500 µl/s PTV conditions Initial temperature -110 C with 0.1. min initial time Heating ramp 150 C with a rate of 12 C/min Hold time 2 min Oven Carrier gas flow (Hydrogen) 2.2 ml/min (constant flow mode) Split ratio 5:1 Oven temperature 35 C for 3 min Heating ramps 10 C/min to 100 C, then 35 C/min to 200 C Final time 4 min Total run time 16.4 min MSD Transfer line temperature 240 C Solvent delay 4 min SIM mode recording m/z 83 Dwell time 100 ms for each ion Tune mode Manual tune for very low masses Experiments conducted and observations: The first experiments were performed applying the previously developed headspace GC-MS method for phosphine 2. Sulfurylfluorid has a boiling point of -55 C and a lower vapor pressure than phosphine with a boiling point of -87.7 C. The compound should, therefore, in theory, be easier to trap. Unfortunately, however, when using the instrument settings for phosphine the peak shape became very poor with a clearly visible fronting (see figure 1). This behavior may be related to a better affinity of phosphine towards the Tenax sorbent material within the liner. To achieve a better chromatographic peak, several parameters were varied. Finally a reduction of the trap temperature to -110 C was necessary to obtain a well-defined peak. 2 http://ejournal.cvuas.de/docs/cvuas_ejournal_201402.pdf [3]

Figure 1: Peak shape of Sulfuryl fluoride at varying trapping temperature -80 C, -100 C and -110 C, injection volume 2000 µl a) -80 C b) -100 C a) c) -100 C [4]

Calibration: Calibrations are linear up to 50 µg/kg at least. As matrix-effects may occur matrix-matched calibration or preferably calibration via standard additions is recommended. The sensitivity of the method is very good and the MRL* of 0.01 mg/kg can thus be easily monitored using this method. Exemplary validation experiment: To validate the method a calibration curve was conducted by injecting the same matrix 4 times but spiked with increasing amounts of sulfuryl fluoride. Cosnidering the lowest spiking level (corresponding to 0.021 mg/kg) as the unknown level to be quantified, the calculated recovery rate was 94%. The different pressure increase caused by the addition of different volume of gaseous sulfuryl fluoride standard did not seem to have any major impact on the linearity of the method and was not taken into account. Figure 3: Standard addition of SO 2 F 2 to soy flour containing 0,021 mg/kg, portion size 1 g, injection volume 1 ml, and spiking volume was 150µl = unknown, 300µl, 450µl and 600µl of gaseous sulfuryl fluoride standard (100 ppm in N2) Discussion and conclusions: A method was developed allowing the sensitive and accurate analysis of sulfuryl fluoride residues in dry food commodities. History Action When Document Version Observation document placed on-line April 2018 V1 [5]