ANALYSIS OF LIFE CYCLE ENERGY CONSUMPTION AND ENVIRONMENTAL LOAD OF INSULATION DESIGN FOR RESIDENTIAL BUILDINGS IN CHINA

Similar documents
LIFE CYCLE ASSESSMENT FOR COOLING AND HEATING SOURCES OF BUILDING

AN LCA FRAMEWORK FOR BUILDINGS IN CHINA

Analysis on the influence of occupant behavior patterns to building envelope's performance on space heating in residential buildings in Shanghai Siyue

Xiaofen Xu, Liang Zhang, Huajing Sha, Ying Ji, Peng Xu. Tongji University, Shanghai, China

affects the credibility of the analysis results. Construction site data is mainly collected from the records of specific case and directly influenced

Energy consumption simulation of the prototypical building for optimizing the orientation of building model in the simulated environment

Effect of insulation ground on anti-condensation in rural residence

The Economic Benefits Analysis on Rural Energy-Saving Housing of Northern China-A Case Study of Woniuhe New Rural Construction, Zhalantun City, China

Simulation and Energy Analysis of Thermal Environment of Unassisted Passive Solar House

Deep energy retrofit An Analysis of Energy Efficient Retrofit Strategies for Office Buildings in China

Influence of Retro-reflective Material on Public Buildings Energy Consumption in Different Climate Regions

Energy-saving Potential Study on Telecommunication Base Station Free Cooling With a Thermosyphon Heat Exchanger in China

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Design of Sunshade Board with South External Window of Residential Building in Hangzhou Based on Software Simulation Analysis of Energy Saving

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Thermal Environment of Chinese Residential Buildings with Different Thermal Insulation Materials in Hot-Summer-and-Cold-Winter Zone of China

The research and simulation on passive solar house with the attached. sunspace in Beijing

ANALYSIS OF ENVELOPE THERMAL BEHAVIOUR THROUGH PARAMETRIC STUDIES. Civil Engineer, PhD, Assistant Professor, Civil Engineering Department (3)

Evaluating Energy Savings Retrofits for Residential Buildings in China

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

EFFECTS OF WEATHERS AND INDOOR TEMPERATURES ON PERFORMANCE OF ENERGY RECOVERY VENTILATOR. Yanping Zhou, Jingyi Wu, Ruzhu Wang

ENERGY EFFICIENT TECHNIQUES AND SIMULATION OF ENERGY CONSUMPTION FOR THE SHANGHAI ECOLOGICAL BUILDING

Systematic Analysis on Sustainable Retrofit of Typical High-rise Community Based on Building Performance Simulation Model Yang Hongwei 1,*, Liu Congho

Discussion on Energy-Efficient Technology for the Reconstruction of Residential. Buildings in Cold Areas

A survey on energy consumption status and characteristics of hotel buildings in Guangzhou

Energy Analysis of Using Thermal Mass in a Hot Humid climate

The Study on Thermal Performance and Applicability of Energy-saving. Wall Materials in Hot Summer and Cold Winter Zones

ASSESSMENT PRACTICES OF GOBAS IN CHINA

A Study on the Evaluation of Heating and Cooling Energy Efficiency in Residential Buildings for Climatic Zones of Turkey

Optimal design for a dual-airflow window for different climate regions in China

RETRACTED ARTICLE. Energy Saving Measures and Strengthening Thermal Insulation Construction Technology in Residential Building Design.

GENERALIZED CRITERIA OF ENERGY PERFORMANCE EVALUATION IN EARLY DESIGN STAGES OF NEARLY ZERO-ENERGY BUILDINGS

Climate Change and Its Impact on Building Energy Consumption in Office Building of Different Climate Zones in China. Methodology

Effects of external window form on residential building energy consumption

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

A Solar Wall System Utilized in Rural Houses of Northeast China

ENERGY SAVING INNOVATION IN CHINESE TRADITIONAL BUILDINGS. L. Zhu Nanjing University of Technology China

China s Building Energy Efficiency Policy and Passive Building Development

THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING AND ENERGY PERFORMANCE FOR AN OFFICE BUILDING IN CANBERRA

The effects of future climate change on energy consumption in residential buildings in China and retrofitting measures to counteract

Influence of Degradation and Service Life of Construction Materials on the Embodied Energy and the Energy Requirements of Buildings

Op#miza#on on Economic Efficiency of a Typical Nearly Zero Energy Residen#al Building Based on Life Cycle Cost Method

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Market size and energy consumption of Korean building sector

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

THE ROAD TO NEARLY ZERO-ENERGY BUILDINGS

caused by subjective factors such as oversimplified modeling for simulation, nonuniform calculation methods, casual input parameters and boundary cond

Energy Consumption Measurement of Energy-saving Buildings and Analysis of Simulation Example

RoboRater. Jim Woolcock Director, Sustainability House

2000 Antwerp, terraced house

EXPERIMENTAL STUDY ON CLAY CERAMISITE THERMAL INSULATION MORTAR

Considerations of Sustainable High-rise Building Design in Different Climate Zones of China

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Analysis of different shading strategies on energy demand and operating cost of office building

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

GREEN BUILDING CONGRESS 2011 NEW DELHI

SKYLIGHT DESIGN PERFORMANCE EVALUATION METHOD DEVELOPMENT WITH THERMAL AND DAYLIGHT SIMULATION

THE THERMAL PERFORMANCE EVALUATION OF A FUTURE CHINESE LOWENERGY APARTMENT WITHIN CHANGING CLIMATE IN HOT SUMMER AND COLD WINTER ZONE IN CHINA

Evaluating Energy Performance and Improvement Potential of China Office Buildings in the Hot Humid Climate against US Reference Buildings

Using phase change materials to reduce overheating issues in UK residential buildings

TOP TEN 2018 O P T E. N s ENERGY EFFICIENCY PRACTICES FOR THE CHINA BUILDINGS SECTOR

International Workshop Mainstreaming Building Energy Efficiency Codes in Developing Countries November 19/20, 2009 The World Bank Washington, DC

Ventilation and Airtightness, different relationship for different quality of buildings

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

Open Access The Impact of Cool Roofs on Energy Consumption of Office Buildings in Chongqing of China

Koniklecová 4, Brno-Nový Lískovec

Assessment of Building Energy Performance for EEMs A Case Study in Mumbai

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

Passivhaus Project Documentation Wrexham Passivhaus

Economical Analysis of the Cold Air Distribution System: A Case Study

Modeling the Housing Energy Efficiency Optimisation in EnergyPlus: The Study of Current Two-storey and New Three-storey Rural Housing in Hong Kong

CASE STUDY HOW COULD WE OPTIMIZE THE ENERGY-EFFICIENT DESIGN FOR AN EXTRA-LARGE RAILWAY STATION WITH A COMPREHENSIVE SIMULATION?

THE PERFORMANCE ANALYSIS OF NATURAL VENTILATION FOR BUILDING COOLING IN CHANGSHA CITY, CHINA 1. Jiasheng Wu, Yan Xu, Junli Zhou, Guoqiang Zhang

BEEP Guidelines for Energy Efficient Design of Multi-Storey Residential Buildings

The Influence of Operation Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner

Classic Competition Weiting Residence

Facade Design for Super High- Rise Building in Subtropic Region in China

Energy study of a non-residential and historic building in transient conditions

LARGE-SCALE IMPLEMENTATION OF ENERGY EFFICIENCY IN BUILDINGS

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Thermal Characteristics of a Vernacular Building Envelope

Study on the heat transfer model and the application of the underground pipe system

Energy Consumption Analysis and Energy Conservation Evaluation of a. Commercial Building in Shanghai

Government Office Buildings Energy Consumption Index Research - by Means of Comparing Simulation and Real Energy Consumption WANG Yichao 1, YAN Da, 1

Application of Low Cost Active and Passive Energy Saving Technologies in an Ultra-low Energy Consumption Building

Annex 66 Definition and Simulation of Occupant Behavior in Buildings

Song Pan et al. / Energy Procedia 142 (2017)

Low energy buildings

Reducing energy demand in non-domestic buildings: integrating smart facades, ventilation, and surface heating and cooling

Energy System Design and Optimization of a Solar Decathlon House

Analysis of the Window Side Thermal Environment Formed by Air Barrier. Technique in Winter Conditions and Its Economy

INTEGRAL BUILDING AND ENERGY DESIGN OF AN OFFICE BUILDING COMPARISON OF INITIAL DESIGN IDEAS WITH MONITORED RESULTS

The Importance of Slab Edge & Balcony Thermal Bridges

Balta Eco Project. group 1

Embodied energy of windows in buildings: impact of architectural and technical choices part 2

Available online at ScienceDirect. Procedia Engineering 146 (2016 )

Minimum Energy Consumption 84% energy heating savings*

Summer season temperature control in Finnish apartment buildings

targeted guiding significance to the methodology making of Beijing carbon trading mechanism in building sector. RESEARCH METHODS In the first and seco

Transcription:

Eleventh International IBPSA Conference Glasgow, Scotland July 27-3, 29 ANALYSIS OF LIFE CYCLE ENERGY CONSUMPTION AND ENVIRONMENTAL LOAD OF INSULATION DESIGN FOR RESIDENTIAL BUILDINGS IN CHINA Lijing Gu 1,a, Borong Lin 1,b, Xiaoru Zhou 1,c, Yingxin Zhu 1,d 1 Department of Building Science, School of Architecture, Tsinghua University, Beijing, China a gulj4@mails.tsinghua.edu.cn, b linbr@tsinghua.edu.cn, c zxr6@mails.tsinghua.edu.cn, d zhuyx@tsinghua.edu.cn ABSTRACT Increasing insulation thickness may reduce the energy consumption and environmental load in building operation phase, but may also increase those in insulation production phase. Therefore, the life cycle energy consumption and environmental load of insulation design for a typical residential building were analyzed in this paper. Cases in four typical cities -Harbin, Beijing, Shanghai and Guangzhou- in four different climate zones in China were compared. The results indicate that increasing insulation thickness based on the active design standards for buildings in Harbin, Beijing and Shanghai, is helpful to reduce building life cycle energy consumption and environmental load. But for buildings in Guangzhou, the insulation thickness should not be increased any more. KEY WORDS insulation, life cycle assessment, energy conservation, environmental load, residential building INTRODUCTION Currently, building operating energy consumption accounts for nearly 25% of the total energy consumption in China (Building Energy Research Center of Tsinghua University, 28). The energy consumption of building materials production, transportation and building construction has also been close to 2% of the total social energy consumption (Jiang, 26). Therefore, building energy saving plays a vital role in the realization of sustainable development in China. The current energy saving work only focuses on reducing building operating energy consumption. One of the main measures for energy saving of building envelope is to improve the thermal performance of insulation and windows. However, the production and transportation of these building materials also consume a lot of energy and resources and produce pollutants. Improving the performance of building envelope often causes the increase in the energy consumption and environmental load of building material production. From the perspective of building s life cycle, the increase of energy consumption and environmental load in building material production phase may balance out those saved in building operation phase. This will be more likely to occur for the area where the heating period is not long and the effects of energy-saving by using insulation are not obvious. In order to take energy-saving measures in accordance with local conditions and to avoid hypercorrectness of energy-saving work, the life cycle assessment (LCA) methodology was adopted in this paper. The life cycle energy consumption and environmental load of different insulation designs for a typical residential building in China were studied, and cases for buildings in different climate zones were analyzed and compared. METHODOLOGY Case Introduction In this paper, a typical high-rise residential building was selected as a study case. It is a 12-storey building, with a total floor area of 6 m 2 and a height of each floor of 2.9 m. There are four houses on each floor. Its layout is shown in Figure 1. The total area of its external walls is 3654 m 2 and the total area of its roof is 5m 2. Figure 1 Layout of building standard floor China is a country with a vast territory and various climates. For different climate zones, there are great difference of building cooling and heating load, so the insulation strategies to be taken should also be different. In this paper, four representative cities, Harbin, Beijing, Shanghai and Guangzhou, respectively in four different climate zones of China were selected, and the effect of increasing insulation thickness on the life cycle energy consumption and environmental load of the above typical residential building in these four cities were analyzed respectively. The climate zones and the locations of the cities are shown in Figure 2. - 1842 -

Figure 2 Climate zones and cities locations The difference of the shape of the residential buildings throughout the country is not large, but there are some differences on the area ratio of window over wall. Therefore when the above typical building was placed in different zones, its area ratio of window over wall was set according to the active local design standard for energy efficiency (China Building Science Research Institute, 1997, 21; Beijing Institute of Architecture Design, 24; Guangdong Construction Department, 26), as shown in Table 1. The thermal performance of external windows required in the energy efficiency design standards of different zones are also different, so it was set differently as shown in Table 1. The mode of heating and cooling and the energy used in different cities are shown in Table 2. For intermittent heating and cooling, the air-conditioners will be turned on only when there is someone in the room. The operation schedules of air conditioners for different types of rooms are shown in Figure 3. The heating temperature of living room and bedroom was set as 18 and cooling temperature was set as 26. The turn-on temperature was 16 for intermittent heating and 29 for intermittent cooling. The inner heat gain from the equipment of living room and bedroom was set as 4.3 W/m 2, their schedules are shown in Figure 4. There were no heating and cooling for kitchens and bathrooms. In addition, considering that the ventilation mode has bigger influence on the energy consumption of the residential building, cases for two ventilation modes, variable and invariable ventilation, were calculated respectively. The ventilation time ranged from.5 to 5 per hour for variable ventilation and was.5 per hour for the whole year for invariable ventilation. The case with the lower limit of insulation thickness that can meet the requirement of the active building design standards was taken as the base case. Table 1 Area ratio of window over wall and window thermal performance AREA RATIO OF WINDOW OVER WALL EAST SOUTH WEST NORTH K a SC b Harbin.1.35.1.25 2.5.75 Beijing.1.45.1.3 2.8.75 Shanghai.1.45.1.4 2.5.6 Guangzhou.1.45.1.4 5.7.6 a: K is the thermal transfer coefficient of window, W/(m 2 K), b: SC is the shading coefficient of window. Table 2 the mode of heating and cooling and the energy used HEATING COOLING Harbin Central heating, continuous, coal Room air conditioner, intermittent, electricity Beijing Central heating, continuous, natural gas Room air conditioner, intermittent, electricity Shanghai Room air conditioner, intermittent, electricity Room air conditioner, intermittent, electricity Guangzhou Room air conditioner, intermittent, electricity Room air conditioner, intermittent, electricity Figure 3 Operation schedules of air conditioners for intermittent heating and cooling - 1843 -

Figure 4 Schedules of inner heat gain Energy Payback Time The energy consumption of building s life cycle contains the energy consumed for building material production and transportation, building construction and operation, building material replacement and maintenance and building demolishment. This paper mainly studied the changes of energy consumption in each phase of building s life cycle when different insulation schemes were used for the same building. Therefore, the differences of energy consumption for different schemes mainly came from the insulation production phase (here and in the following text, production phase also includes the transportation and demolishment phase of the insulation) and building operation phase. The difference of energy consumption in construction phases for different schemes were also mainly caused by the difference of insulation thickness, but was much less than that in insulation production phase, so they were neglected in this study. The energy consumption of building material production can be described by embodied energy. A product s embodied energy refers to the sum of energy consumption of all relevant processes before the product leaves factory, including processes of raw material extraction, transportation, processing, and assembly and so on (Laoson, 1996). In calculation, the consumption of different types of energy is all converted into the consumption of primary energy. Generally, the embodied energy per unit mass of the product is used to represent its energy consumption density. Expended polystyrene (EPS) board is a kind of commonly used insulation in China currently, so it was chosen for study in this paper. According to Chen s study (Chen et al., 24; Hong et al., 21), the embodied energy of EPS in China was 173 MJ/kg, among which about 9MJ is production energy consumption and the rest is the energy contained in raw material, oil. The density of EPS used for building insulation is about 22 kg/m 3. The heat conduction coefficient of EPS is.42 W/(m K). The lifespan of EPS was considered as 15 years in this paper. Firstly, building loads were simulated hour by hour by an energy simulation tool, DeST (Yan, 24). Then the annual building operating energy consumption can be calculated, and the electricity consumption was converted into primary energy consumption according to the coal consumption of power generation. Here, the efficiency of coal-fired boiler was assumed as.78; the efficiency of gas-fired boiler was assumed as.89; the coefficient of performance (COP) of air-conditioner was assumed as 2.4 in summer in Harbin (Li, 27), 2.3in summer in Beijing (Li, 27), 1.9 in winter and 2.3 in summer in Shanghai (China Building Science Research Institute, 21), and 2.7 in summer in Guangzhou (Guangdong Construction Department, 26); the efficiency of the central heating net was assumed as.9; and the coal consumption of power generation was.35 kgce/kwh according to the statistical data in 25. For residential buildings, the increase of insulation thickness may reduce the energy consumption of building operation, but at the same time will increase the energy consumption of insulation production. This study analyzed how long the energy consumption increased in insulation production phase can be paid back by that reduced in building operation phase, and called this time the energy payback time (EPT) of the insulation, which can be calculated with equation (1): OECb OEC EPT = (1) EE EEb Where EPT is the EPT of insulation, a; OEC is the annual operating energy consumption per unit floor area, MJ/(m 2 a); EE is the total embodied energy of all the insulation of building envelope per unit floor area, MJ/m 2 ; subscript "b" refers to the corresponding variables of the base case. If the EPT is shorter than the insulation s lifespan, it means that increasing insulation thickness based on the base case is helpful to reduce the energy consumption throughout the building s life cycle. Environmental Load Payback Time Building activities consume not only energy but also a lot of mineral resources. In addition, the process such as energy production and use, building material production, product transportation and so on, also produce various pollutants. Therefore the impact building has on the environment is various and complicated. LCA is a method to quantifying the comprehensive environmental impact of a product or activity s life cycle. Some Chinese scholars have put forward the LCA systems to analyze the environmental impact of buildings in China. In this paper, the system, Building Environmental Load Evaluation System (BELES), founded by Dr. Gu (Gu, 26), was adopted to analyze the comprehensive environmental impact of the study case. The evaluating indicator in BELES is the Environmental - 1844 -

Load with unit point and pt for short. In this study, only insulation thickness differs among different cases in the same city, so only the environmental load of the insulation production was considered when calculating the environmental load in building material production phase. The environmental load in building operation phase mainly comes from the process of energy production and use. The life cycle inventory of insulation and energy were all from the database of BELES. The calculation with BELES showed: the environmental load of EPS production is 8.55 1-3 pt/kg, the environmental load of coal-fired heating is 5.1 1-5 pt/mj of boiler heat consumption, the environmental load of gas-fired heating is 5.69 1-5 pt/mj of boiler heat consumption, and the environmental load of power generation and distribution is 6.5 1-4 pt/kwh. The increase of insulation thickness may reduce the energy consumption of building operation, and accordingly reduce the environmental load of building operation, but at the same time will increase the environmental load of insulation production. This study analyzed how long the environmental load increased in insulation production phase can be paid back by that reduced in building operation phase, and called this time the environmental load payback time (ELPT) of the insulation, which can be calculated with equation (2): OELb OEL ELPT = IEL IELb (2) Where ELPT is the ELPT of insulation, a; OEL is the annual operating environmental load per unit floor area, pt/(m 2 a); IEL is the total environmental load of all the insulation of building envelope per unit floor area, pt/m 2 ; subscript "b" refers to the corresponding variables of the base case. If the ELPT is shorter than the insulation s lifespan, it means that increasing insulation thickness based on the base case is helpful to reduce the environmental load throughout the building s life cycle. RESULTS Harbin Harbin locates in the Severe Cold Zone of China. For the base case in Harbin, the insulation thickness of wall and roof were both 8 mm, and the corresponding heat transfer coefficient of wall and roof were.52 W/(m 2 K) and.5 W/(m 2 K) respectively. With the increase of insulation thickness, the energy consumption and environmental load in building operation phase and the two kinds of payback times changed, which are shown in Figure 5. Operating energy consumption Operating environmental load payback time (a) (MJ/(m 2 a)) (pt/(m 2 a)) 5. 4. 3. 2. 1.. 35 3 25 2 15 1 5 variable vent. winter invariable vent. winter variable vent. summer invariable vent. summer 8/8 9/9 1/1 11/11 12/12 13/13 14/14 15/15 Insulation thickness of wall/roof ( 1 mm) Figure 5-a operating energy consumption.2.15.1.5. viriable ventilation inviriable ventilation 8/8 9/9 1/1 11/11 12/12 13/13 14/14 15/15 Insulation thickness of wall/roof ( 1 mm) Figure 5-b operating environmental load EPT variable vent. ELPT variable vent. EPT invariable vent. ELPT invariable vent. 8/8 9/9 1/1 11/11 12/12 13/13 14/14 15/15 Insulation thickness of wall/roof ( 1 mm) Figure 5-c payback time Figure 5 Results of Harbin The residential building in Harbin has almost no cooling energy consumption. Invariable ventilation will obviously increase the energy consumption of cooling in summer, and accordingly increase building s operating energy consumption and environmental load. The energy consumption and environmental load of building operation reduced with the increase of insulation thickness. The two kinds of payback times of insulation are short. Within the range of the insulation thickness that has been analyzed, the energy consumption increased in insulation production can be paid back within 2.6-4.1 years and the environmental load can be paid back within 2.5-4.1 years. Beijing Beijing locates in the Cold Zone of China. For the base case in Beijing, the insulation thickness of wall - 1845 -

and roof were 3 mm and 45 mm respectively, and the corresponding heat transfer coefficient of wall and roof were 1.13 W/(m 2 K) and.77 W/(m 2 K) respectively. The change of the energy consumption and environmental load in building operation phase and the two kinds of payback times with the increase of insulation thickness are shown in Figure 6. Operating energy consumption (MJ/(m2 a)) Operating environmental load payback time (a) (pt/(m 2 a)) 5. 4. 3. 2. 1.. 14 12 1 8 6 4 2 variable vent. winter variable vent. summer invariable vent. winter invariable vent. summer 3/45 4/5 5/55 6/6 7/65 9/85 11/15 Figure 6-a operating energy consumption.12.1.8.6.4.2. variable ventilation invariable ventilation 3/45 4/5 5/55 6/6 7/65 9/85 11/15 Figure 6-b operating environmental load EPT variable vent. ELPT variable vent. EPT invariable vent. ELPT invariable vent. 3/45 4/5 5/55 6/6 7/65 9/85 11/15 Insulation thickness of wall/roof ( mm) Figure 6-c payback time Figure 6 Results of Beijing The energy consumption of the residential building in Beijing mainly comes from heating. Invariable ventilation will obviously increase the energy consumption of cooling in summer, and accordingly increase building s operating energy consumption and environmental load. The energy consumption and environmental load of building operation reduced with the increase of insulation thickness. Within the range of the insulation thickness that has been analyzed, the energy consumption increased in insulation production can be paid back within 2.-4.9 years and the environmental load can be paid back within 1.7-4.2 years. Shanghai Shanghai locates in the Hot Summer & Cold Winter zone of China. For the base case in Shanghai, the insulation thickness of wall and roof were both 25 mm, and the corresponding heat transfer coefficient of wall and roof were 1.2 W/(m 2 K) and 1.1 W/(m 2 K) respectively. Figure 7 shows the changes of the energy consumption and environmental load in building operation phase and the two kinds of payback times with the increase of insulation thickness. Operating electricity consumpiton Operating environmental load payback time (a) (kwh/(m 2 a)) (pt/(m 2 a)) 2. 15. 1. 5.. 9 8 7 6 5 4 3 2 1 variable vent. winter invariable vent. winter variable vent. summer invariable vent. summer 25/25 35/35 45/45 55/55 65/65 75/75 Figure 7-a operating energy consumption.8.6.4.2. variable ventilation invariable ventilation 25/25 35/35 45/45 55/55 65/65 75/75 Figure 7-b operating environmental load EPT variable vent. ELPT variable vent. EPT invariable vent. ELPT invariable vent. 25/25 35/35 45/45 55/55 65/65 75/75 Insulation thickness of wall/roof ( mm) Figure 7-c payback time Figure 7 Results of Shanghai When ventilation times are variable, the heating - 1846 -

energy consumption of the residential building in Shanghai is more or less the same as the cooling energy consumption. Invariable ventilation will obviously increase the energy consumption of cooling in summer, and accordingly increase building s operating energy consumption and environmental load. Except case 75/75 with invariable ventilation, the increase of insulation thickness is helpful to reduce the energy consumption and environmental load of building operation. Within the range of the insulation thickness that has been analyzed, the energy consumption increased in insulation production can be paid back within 5.6-14.2 years and the environmental load can be paid back within 4.7-13.4 years. payback time (a) 2 18 16 14 12 1 8 6 4 2 EPT variable vent. EPT invariable vent. ELPT variable vent. ELPT invariable vent. 3/3 4/4 5/5 6/6 7/7 Insulation thickness of wall/roof ( mm) Figure 8-c payback time Figure 8 Results of Guangzhou Guangzhou Guangzhou locates in the Hot Summer & Warm Winter Zone of China. For the base case in Guangzhou, the insulation thickness of wall and roof were 3 mm and 3 mm respectively, the corresponding heat transfer coefficient of wall and roof were both 1. W/(m 2 K). With the increase of insulation thickness, the energy consumption and environmental load in building operation phase and the two kinds of payback times changed, which are shown in Figure 8. Operating electricity consumption Operating environmental load (kwh/(m 2 a)) (pt/(m 2 a)) 14 12 1 8 6 4 2 variable vent. invariable vent. 3/3 4/4 5/5 6/6 7/7 Figure 8-a operating energy consumption.8.6.4.2. variable ventilation invariable ventilation 3/3 4/4 5/5 6/6 7/7 Figure 8-b operating environmental load The residential building in Guangzhou only has cooling energy consumption. Invariable ventilation will double the energy consumption of cooling in summer, and accordingly double building s operating energy consumption and environmental load. The increase of insulation thickness has very slight effect on the energy consumption and environmental load of building operation. The two kinds of payback times for all the options are longer than the insulation s lifespan, the payback times for some cases with invariable ventilation mode are even longer than one hundred years. This means the energy consumption and environmental load increased in insulation production can not be paid back for any case of Guangzhou. ANALYSIS From the above results, the following conclusions can be drawn: 1. For all these cities, the operating energy consumption and environmental load of buildings reduce with the increase of insulation thickness, but the reduction becomes less and less. In addition, the lower the latitude of the city, the less obvious the reduction is. There is only very slight reduction for cases in Guangzhou. 2. For all the cities, the cooling energy consumption in summer under invariable ventilation mode are higher than those under variable ventilation mode, and the lower the latitude of the city, the more obviously the cooling energy consumption increased by invariable ventilation. 3. The lower the latitude of the city, the longer two kinds of the payback times. Within the range of insulation thickness that has been analyzed, the payback times of cases in Harbin and Beijing are shorter than 5 a. The payback times of cases in Shanghai is 4.7 a at least, but the longest one exceeds the insulation s lifespan. The payback times of cases in Guangzhou are all longer than the insulation s lifespan, which means the increased energy consumption and environmental load in insulation production can not be paid back for any case in Guangzhou. 4. No matter in which area, the two kinds of - 1847 -

payback times will become longer and longer with the increase of insulation thickness. This is because the increase of energy consumption and environmental load of insulation production has a direct ratio with the increase of insulation thickness, but the reduction of operating energy consumption and environmental load decrease with the increase of insulation thickness. Thus it becomes more and more difficult to pay back the increased energy consumption and environmental load for insulation production when the insulation getting thicker and thicker. 5. As for a specific insulation scheme, the EPT is longer than the ELPT. This is because the energy consumption as raw material of insulation only has impact of energy exhaustion, but other energy consumption for insulation production or for building operation also has the impact of pollutant emission from energy combustion. Thus when only energy consumption is considered, the raw material energy consumption will has more contribution and make the EPT longer than the ELPT. 6. For a specific insulation scheme, the payback times of invariable ventilation mode is longer than that of variable ventilation mode. The lower the latitude of the city, the more effect the invariable ventilation has on the payback times. In the south part of China, it can be concluded that good natural ventilation design in residential building has much better effect on energy saving than increasing insulation s thickness. CONCLUSIONS In this paper the effect of increasing insulation thickness on the life cycle energy consumption and environmental load of a typical residential building were analyzed. The case with the lower limit of insulation thickness that can meet the requirement of active building design standards was taken as the base case. The insulation thickness was increased gradually from the lower limit and the EPT and ELPT were calculated for each case. Cases for buildings in the representative cities, Harbin, Beijing, Shanghai and Guangzhou, respectively from the four climate zones in China were analyzed and compared. In addition, two scenarios, variable and invariable ventilation, were calculated respectively. Within the range of the insulation thickness that has been analyzed, the energy consumption and environmental load increased in insulation production can be paid back in short time in Harbin and Beijing. The payback times in Shanghai are relatively long, but all the cases with variable ventilation can be paid back. However in Guangzhou, the two kinds of payback times are longer than the insulation s lifespan for all the cases. These indicate that increasing insulation s thickness is helpful to reduce the life cycle energy consumption and environmental load for residential buildings in Harbin and Beijing. But in Shanghai, the insulation s thickness should be controlled to avoid being too thick. However, for cities in Hot Summer & Warm Winter Zone, like Guangzhou, the insulation s thickness should not be increased any more based on the active design standard. In addition, proper ventilation can reduce the operating energy consumption and environmental load for the residential building in all the cities and meanwhile proper ventilation may not increase environmental impact in production phase. As for Hot Summer & Warm Winter Zone and Hot Summer & Cold Winter Zone, the benefit of proper ventilation is more obvious and much better than the benefit of insulation. Therefore, it should be encouraged in priority to make good ventilation design for buildings in the south part of China. When the payback time of a case is shorter than the insulation s life span, it only means the insulation scheme for this case is better than the base case. But which scheme has the best life cycle environmental performance should be judged by the total amount of the environmental load it has throughout building s life cycle. This will be studied in the future to find the optimal insulation thickness for residential buildings in different climate zones. What should be stated is that the specific value of the result are obtained based on the specific setting in this paper, including indoor heat gain, the way and the schedule of heating and cooling, energy type, insulation type and its physical performance, et al. When these parameters change, the result value may accordingly change. So the specific problem needs specific analysis. But the conclusions about the changing trend or relative magnitude of the payback times are universal. REFERENCE Building Energy Research Center of Tsinghua University. 28. 28 Annual Report on China building energy efficiency. Beijing: China Architecture & Building Press. Beijing Institute of Architecture Design. 24. DBJ 1-62-24 Design Standard for Energy Efficiency of Residential Building. Beijing: Beijing Construction Committee. Chen H, Hao W.C., Shi F, et al. 24. Life cycle assessment of several typical macromolecular materials. ACTA Scientiae Circumstantiae, 24(3):545-549. China Building Science Research Institute. 1997. JGJ 26-95 Design Standard for Energy Efficiency of Civil Building (heating of residential building). Beijing: China Architecture & Building Press. China Building Science Research Institute. 21. JGJ 134-21 Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Cold Winter Zone. Beijing: China Architecture&Building Press. - 1848 -

Gu D.J. 26. Life cycle assessment of building environmental load. Beijing: Tsinghua University. Guangdong Construction Department. 26. DBJ 15-5-26 Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Warm Winter Zone (detailed implementing rules). Beijing: China Association for Engineering Construction Standardization. Jiang Y. Control construction scale and build resource-saving society. 26. China Construction, 13(6): 12-15. Li Z.J. 27. Study on the life cycle consumption of energy and resource of air conditioning in urban residential buildings in China. Beijing: Tsinghua University. Laoson B. 1996. Building materials, energy and the environment: towards ecologically sustainable development. Australia: Royal Australian Institute of Architects. Yan D, Xie X.N., Song F.T., et al. 24. Building environment design simulation software DeST (1): an overview of developments and information of building simulation and DeST. HV&AC, 34(7):48-56. - 1849 -