FOR THE PURECELL 200 FUEL CELL. Draft. July 5, Submitted to: United Technologies Power 195 Governor s Hwy South Windsor, CT

Similar documents
MONITORING PLAN FOR THE PURECELL 400

MONITORING PLAN FOR THE PURECELL 400 FUEL CELL

M&V Plan for DG/CHP System

300 Central Park West. Site Contact. Overview. Monitoring Notes. M&V Instrumentation Installation. 300 Central Park West Site Information

Avalon Fort Greene. Site Contact. Summary. Avalon Fort Greene Site Information. 343 Gold St Brooklyn, NY 11201

Times Square Apartments. Site Contact. Overview. M&V Instrumentation Installation. Times Square Apartments Site Information

MONITORING PLAN FOR THE PURECELL 400 FUEL CELL

FOR THE PURECELL 400 FUEL CELL. Draft. July 9, Submitted to: United Technologies Power 195 Governor s Hwy South Windsor, CT

FOR THE PURECELL 400 FUEL CELL IN WILLIMANTIC, CT. Draft. June 22, Submitted to:

MEASUREMENT AND VERIFICATION PLAN

Adjustments To Aegis CHP Thermal Data at The Schwab House

MEASUREMENT AND VERIFICATION PLAN

FOR. Burrstone Energy Center LLC. August Submitted to:

MONITORING AND DATA COLLECTION STANDARD FOR DISTRIBUTED ENERGY RESOURCE (DER) SYSTEMS. Submitted to:

SAMPLE MEASUREMENT AND VERIFICATION (M&V) PLAN

MEASUREMENT AND VERIFICATION PLAN

Monitoring and Analysis Plan for Aegis AGEN-75 CHP System at the 250 West 50 th Street Manhattan, NY Archstone Midtown

Metering Fundamentals for Demand Response

Rochester Airport Data Integrator Notes

MEASUREMENT AND VERIFICATION PLAN

Addendum Gateway CHP Verification and Commissioning

East Rochester School District East Rochester, NY

Monitoring and Analysis Plan for Aegis AGEN-75 CHP System at the 300 E 40 th St Manhattan, NY The Churchill

Burrstone Energy Center, LLC, St. Lukes Hospital, Home, and Utica College Data Integrator Notes

Monitoring and Analysis Plan for Aegis AGEN-75 CHP System at the Trump Towers City Center

Energy metering is required to comply with the requirements of the Building Regulations.

Meters Performance Guide

4C Foods Data Integrator Notes

MEASUREMENT AND VERIFICATION (M&V) PLAN

Monitoring and Analysis Plan for Aegis AGEN-75 CHP System at the th Avenue The Chelsea Mercantile

Meters Installation Guidelines

MEASUREMENT AND VERIFICATION PLAN

Hazel Towers Data Integrator Notes

CLARKSON UNIVERSITY, DG/CHP SYSTEM NOTES

MEASUREMENT AND VERIFICATION PLAN

Control Products & Systems OEM siemens.com/buildingtechnologies-oem

Monitoring and Analysis Plan for Aegis AGEN-75 CHP System at the th Ave Manhattan, NY Archstone Chelsea

THE INTREPID MUSEUM PIER 86, NEW YORK, NY COMBINED HEAT, COOLING AND POWER INSTALLATION

MEASUREMENT AND VERIFICATION (M&V) PLAN

Allied Frozen Storage Site - Data Integrator Notes

1. Scope. 2. Metering Scenarios

MEASUREMENT AND VERIFICATION PLAN

NORTH AMERICAN MONITORING OF A HOTEL WITH ROOM SIZE GSHPS

MPM 100 Monitor Product Description Guide

Ultraflex MV2 Final Data Summary

602VFM MULTIVARIABLE VORTEX MASS FLOWMETER

602VFM MULTIVARIABLE VORTEX MASS FLOWMETER

POWER TO PROFIT INTRODUCTION TO COMBINED HEAT & POWER

Fuel Cells: The Clean Energy You Count On Gas Policy Conference APGA/SGA

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

MEASUREMENT AND VERIFICATION (M&V) PLAN FOR ROACH DAIRY FARM ANAEROBIC DIGESTER GAS (ADG) SYSTEM

United Technologies Corporation

Ground-Coupled Heat Pump And Energy Storage

Estimating energy consumption by purpose and analyse standby power in non-residential buildings in Japan

Measurement and. Verification, Best Practices in Design and Implementation. Tom Martin CMVP, LEED AP. Homay Khatami CEM, LEED AP PMP, CMC

ALTRONIC RESEARCH, INC.

FMI ENERGY CONFERENCE. Orlando September 2008

MEASUREMENT AND VERIFICATION PLAN

Energy Management System Application Datasheet

Energy Management System Application Datasheet

PQ04. Understanding Power Monitoring

MONITORING AND DATA COLLECTION FOR DISTRIBUTED GENERATION/ COMBINED HEAT AND POWER (DG/CHP) SYSTEMS AT ALLIED FROZEN FOODS BROCKPORT, NEW YORK.

Microturbine Energy Solutions in the CHP Industry

CASE STUDY. Combined Heat and Power System Installation at Atrium II Condominium, 65 Spring Garden Avenue, Toronto

MEASUREMENT AND VERIFICATION (M&V) PLAN

Heat Recovery. Integrated CHP Systems Corp.

Monitoring Plan for the. Cornell Combined Heat and Power Project (CCHPP) October 2008

Monitoring and Analysis Plan for UTC Power Fuel Cell at the Hilton Towers

Southern California Gas Company Customer Programs Department

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Portable Ultrasonic Flow Meters Ultrasonic Flow Meters Handheld Ultrasonic Flowmeter Wallmounted Ultrasonic Flow Meter Explosion Proof Ultrasonic

NYSERDA s s DG/CHP Integrated Data System. chp.nyserda.org

CREATIVE ENERGY NES Building Compatibility Design Guide October 15

Cabrini Terrace Combined Heat and Power

Design and development of a residential gas-fired heat pump

Noblehurst Dairy Linwood, NY

WT Model Water-to-Water Heat Pump

University of Bath Generic Metering Specification (Rev6)

Industrial Metering Energy Concepts and Best Practices

Mechanical Project Proposal

Portable Ultrasonic Flowmeter

Adam Alaica, M.A.Sc., E.I.T.

Southern California Gas Company Customer Programs Department

Series TUF Ultrasonic Energy Meter with BACnet Communication. Specifications - Installation and Operating Instructions 4-1/4 [108.

Building Operator Certification Level I

VLM10 In-line Vortex Mass Flow Meter

The U.S. Department of Energy Federal Energy Technology Center. Climate Change Fuel Cell Program. The Richard Stockton College of New Jersey Fuel Cell

Higher Value Commissioning

INFOCAL 6 Heat calculator

REVENUE METERING REQUIREMENTS MANUAL (REDLINE VERSION)

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

High Impact Hotel Projects

United Technologies Corporation

ULTRAHEAT / ULTRACOLD T550 (UH50...) The Professional: High-precision, modularity, reliable technology for all applications

Arrow Linen: CHP Washes Away Energy Costs of Commercial Laundry

ETV Joint Verification Statement

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Helping Building Services Engineers Apply Low Carbon Technologies

NYSERDA CHP Assessment Report A S S E S S I N G T H E C H P P L A N T A T T O R E N C O N D O M I N I U M S

NYSERDA CHP Assessment Report A S S E S S I N G T H E C H P P L A N T A T C L A R K S O N U N I V E R S I T Y

Transcription:

MONITORING PLAN FOR THE PURECELL 200 FUEL CELL AT PRICE CHOPPER IN GLENVILLE, NY Draft July 5, 2011 Submitted to: United Technologies Power 195 Governor s Hwy South Windsor, CT 06074 Submitted by: CDH Energy Corp. PO Box 641 2695 Bingley Rd. Cazenovia, NY 13035 (315) 655-1063

TABLE OF CONTENTS Introduction... 1 System Description... 1 Heat Recovery Monitoring System... 1 Calculated Quantities... 5 Project Web Site... 7 Appendix A Monitoring System Details

Introduction This plan describes our approach to monitoring the performance of the fuel cell systems installed at the Price Chopper supermarket in Glenville, NY. The UTC Power PureCell Model 200 fuel cell provides clean and efficient electric power and thermal output to the facility. This fuel cell is expected to supply electricity in addition to standby power in the event of a power grid failure. The facility will also recover heat from the fuel cells to use for space and Domestic Hot Water (DHW) heating. System Description The PureCell Model 200 unit is installed behind the facility. The fuel cell (FC) has separate electrical feeds for parallel operation with the utility or to provide backup power when isolated from the grid. The fuel cell is able to provide 200 kw of electrical power and up to 900,000 Btu/h of heat. If fully utilized, the fuel cell can obtain a thermal efficiency near 90%. Power Output: 200 kw 480V, 3ph Figure 1. PureCell 200 Unit Most of the thermal output from the FC is used to provide space conditioning and water heating for the facility. The low temperature hot water loop supplies 130ºF water to meet space heating loads including hot water coils and radiant floor heating circuits (see Figure 2). Heat Recovery Monitoring System The heat recovery monitoring system (HRM) has been designed to capture the electrical and thermal performance of the system. Table 1 summarizes the measurements that will be captured at the site. CDH Energy 1 July 2011

Figure 2 shows where the measurements will be made in the thermal loops. Figure 3 and Figure 4 show the locations for the temperature measurements and flow meters in thermal circuits. Flow and temperature sensors are installed for two thermal loops: low temperature and cooling water. Data are extracted from the Shark Power Meter via MODBUS RTU. The Obvius AcquiSuite datalogger logs the required data. Table 1. Summary of Measured and Collected Data at the Site Channel / Source Data Pt Description Instrument / Meter Signal / Register Eng Units Wire Notes Main-1 FG Instantaneous Fuel Flow Roots Series B3 Gas Meter Pulse lb/h Temperature Compensated Main-2 FL Low Temp Water Flow Onicon Flow Meter 4-20 ma gpm 6 2" Type L Copper Main-3 FCW Cooling Water Flow Onicon Flow Meter 4-20 ma gpm 5 2" Type L Copper Main-4 TLS Low Temp Supply Temp (from FC) 10k Thermistor, Type 2 ohm F 3 Main-5 TLR Low Temp Return Temp (to FC) 10k Thermistor, Type 2 ohm F 4 Main-6 TCWS Cooling Water Supply Temp (from FC) 10k Thermistor, Type 2 ohm F 1 Main-7 TCWR Cooling Water Return Temp (to FC) 10k Thermistor, Type 2 ohm F 2 Modbus Dev 1 WREC_pos Energy Imported (RECs meter) Shark 100 Double kwh RS-485 Modbus Dev 1 WREC_neg Energy Produced (RECs meter) Shark 100 Double -kwh RS-485 Modbus Dev 1 WDREC Power through RECs meter Shark 100 Float Watts RS-485 Note: Main = Obvius main board, device 250 Low Temp Loop Building Loads TLS FL TLR Cooling Module TCWS TCWR FCW Fuel Cell Figure 2. Schematic of Heat Transfer Loops in Fuel Cell System CDH Energy 2 July 2011

FL TLS TLR Figure 3. Locations of Low Grade Loop Temperature and Flow Sensors in Rear of the Facility CDH Energy 3 July 2011

TCWS FCW TCWR Figure 4. Locations of Cooling Module Loop Temperature and Flow Sensors in Rear of the Facility The monitoring system is based around the Obvius AcquiSuite data logger. The layout of the HRM and the connections with other network components of the Fuel Cell system are shown in Figure 5. CDH Energy 4 July 2011

Analog inputs Thermistors 4-20 ma HRM Box Ethernet Switch AcquiSuite 192.168.0.220 Digi 192.168.0.100 to Internet MODBUS RS485/RTU Shark Meter Modbus Dev #1 Figure 5. Layout of HRM Network Calculated Quantities Heat Recovery Rates The data to determine the delivered heat recovery energy and the delivered cooling will be collected by the datalogger at each scan interval and then averaged for each 15-minute recording interval. The calculations listed below will be completed before the data are displayed on the web site: Q lo 1 n n i1 k lo FL ( TLS i i TLR ) i Q cw 1 n n i1 k cw FCW ( TCWS i i TCWR ) i where: Q xx - Delivered heat recovery for loop xx (Btu/h) (xx :: lo = low temp, cw = cooling water) k xx - density specific heat product constant for fluid in loop xx i - i th scan (or read) n - number of scans in the averaging period CDH Energy 5 July 2011

The loop fluid is expected to be water with ethylene glycol (e.g., DowFrost). The factor k is equal to: Low Temp Loop: k lo = 456.6 Btu/h gpm F for 40% glycol at 130ºF Cooling Water: k cw = 459.3 Btu/h gpm F for 40% glycol at 180ºF The Useful and and Unused heat recoveries will be: Q useful = Q lo Q unused = Q cw Power and Energy Generally power meters can provide a host of data points, many of them redundant. Our approach, where possible, is to grab the register value associated with energy (kwh) and from that value determine the average power for each 15-minute interval. This average power value is defined as: kw kwh avg t This average Power over a short time interval (15 minutes) is usually indistinguishable from the demand or instantaneous power data reported by most meters (most utilities use a sliding 15- minute interval). The fuel cell PPC is given as instantaneous kw. Cumulative reads are in kwh. Efficiency Calculations The electrical and total efficiency of the Fuel Cell, based on the lower heating value of the fuel, will be calculated using: electrical LHV WFC FG 1 3600 total 1 WFC QL 3412.8 1 LHV FG 3600 where: QL - Useful heat recovery low temperature loop (Btu/h) WFC - Power output (kw) FG - Generator gas input (kg/h) LHV - Lower heating value for natural gas (~48,667 kj/kg) CDH Energy 6 July 2011

Greenhouse Gas Calculations To determine the reductions in greenhouse gas emissions for the fuel cell system, we need to measure or estimate the emissions from the fuel cell itself and then also estimate the emissions that would have occurred without the fuel cell meeting these loads. The displaced emissions include the CO 2 not emitted at the utility power plant because of lower electrical consumption and the CO 2 not emitted by an on-site furnace or boiler to meet the thermal output. Table 2 lists the emissions factors we will use for the displaced emissions. Table 2. Displaced Emissions Factors Natural Gas Electricity from Power Plant CO 2 emissions 12.06 lb per CCF 1.28 lb per kwh Massachusetts 0.98 lb per kwh Connecticut 0.86 lb per kwh New York NOx emissions 0.1 lb per CCF 2.45 lb per MWh Massachusetts 2.45 lb per MWh Connecticut 2.45 lb per MWh New York Notes: CCF ~ 100 MBtu CO 2 data from EIA state-by-state summary, 1998-2000. NOx data based on NY State. The equations to calculate actual and displaced emissions are listed below: Displaced emissions = (kwh produced) (lb/kwh) + (thermal output, MBtu) (lb/ccf) / 100 0.80 Actual emissions = (Natural gas input, therms) (lb/ccf) Reduced Emissions = (Displaced emissions, lbs) (Actual Emissions, lbs) Project Web Site CDH will create a web site for Price Chopper that provides access to all the historic data collected at the site. The website will provide custom, detailed plots and tables of the collected data from the site that will be updated once a day. CDH Energy 7 July 2011

Appendix A - Fuel Cell HRM at Price Chopper, Glenville Internet address: 166.141.147.129 Table 3. Summary of Major HRM Components Obvius AcquiSuite A8812 This datalogger includes thermistors and flow meters to measure thermal loads. All data are stored in the AcquiSuite memory and transferred to the CDH Energy servers from this device. The AcquiSuite can also create a file every few minutes that is used to generate the real-time screen. PC Glenville System Details A-1 July 5, 2011

Analog inputs Thermistors 4-20 ma HRM Box Ethernet Switch AcquiSuite 192.168.0.220 Digi 192.168.0.100 to Internet MODBUS RS485/RTU Shark Meter Modbus Dev #1 Figure 6. Layout of HRM Network The AcquiSuite performs all communications with devices on the network. It reads data from the temperature and flow sensors and from the Shark power meter, and then logs all the data. Table 4. Network Devices and Addresses Network Layout IP Address MODBUS RTU MODBUS RTU Label Device Protocol Mode Address AcquiSuite Obvius AcquiSuite Modbus TCP 192.168.0.220 Modbus RTU Master Shark Shark 100 - REC Power Transducer Modbus RTU Slave 1 PC Glenville System Details A-2 July 5, 2011

Table 5. Listing of Data Points Collected from all Devices Source CDH Name UTC / Obvius Variable Name Description Native Units Source Data Wire Notes Main-1 FG FG Ave Fuel flow rate lb/h Pulse Roots Gas Meter Main-2 FL FL Ave Flow rate low grade heat gpm 4-20 ma (0-??) 6 Onicon Meter Main-3 FCW FCW Ave Flow rate cooling water gpm 4-20 ma (0-85) 5 Onicon Meter Main-4 TLS TLS Ave Temperature low grade heat supply F ohm 3 10k, Type 2 Main-5 TLR TLR Ave Temperature low grade heat return F ohm 4 10k, Type 2 Main-6 TCWS TCWS Ave Temperature cooling water supply F ohm 1 10k, Type 2 Main-7 TCWR TCWR Ave Temperature cooling water return F ohm 2 10k, Type 2 Address Type SHARK WREC_pos W-hours, Received Energy Imported (RECs meter) kwh 1100 Double RS-485 Modbus RTU SHARK WREC_neg W-hours, Delivered Energy Produced (RECs meter) -kwh 1102 Double RS-485 Modbus RTU SHARK WDREC Watts, 3-Ph total Power through RECs meter Watts 900 Float RS-485 Modbus RTU = Data from sensors on Obvius AcquiSuite = Data from Shark Meter via MODBUS RTU Table 6. Sensor and Wiring Details for AcquiSuite Channel / Source Data Pt Description Instrument / Meter Signal / Register Eng Units Wire Notes Main-1 FG Instantaneous Fuel Flow Roots Series B3 Gas Meter Pulse lb/h Temperature Compensated Main-2 FL Low Temp Water Flow Onicon Flow Meter 4-20 ma gpm 6 2" Type L Copper Main-3 FCW Cooling Water Flow Onicon Flow Meter 4-20 ma gpm 5 2" Type L Copper Main-4 TLS Low Temp Supply Temp (from FC) 10k Thermistor, Type 2 ohm F 3 Main-5 TLR Low Temp Return Temp (to FC) 10k Thermistor, Type 2 ohm F 4 Main-6 TCWS Cooling Water Supply Temp (from FC) 10k Thermistor, Type 2 ohm F 1 Main-7 TCWR Cooling Water Return Temp (to FC) 10k Thermistor, Type 2 ohm F 2 Modbus Dev 1 WREC_pos Energy Imported (RECs meter) Shark 100 Double kwh RS-485 Modbus Dev 1 WREC_neg Energy Produced (RECs meter) Shark 100 Double -kwh RS-485 Modbus Dev 1 WDREC Power through RECs meter Shark 100 Float Watts RS-485 PC Glenville System Details A-3 July 5, 2011

Table 7. Forwarded Addresses on Digi Modem Obvius AcquiSuite The AcquiSuite data logger produces a separate file of 15-minute data for each device. The read map for the data logger is given below. Device 001 (SHARK Meter): Column WREC_pos...16 WREC_neg...15 WDREC...9 Device 250 (AcquiSuite Main Board): FG...1 FL...6 FCW...11 TLS...16 TLR...21 TCWS...26 TCWR...31 Sensor Calibrations: Thermistor # Name Wire Input Channel Offset 4-26 TLS 3 Main-4-2.1 4-25 TLR 4 Main-5-1.7 4-24 TCWS 1 Main-6-1.3 4-23 TCWR 2 Main-7-1.2 PC Glenville System Details A-4 July 5, 2011