CARES Technical Approval Report TA1C

Similar documents
CARES Technical Approval Report TA1-B 5040

CARES Technical Approval Report TA1-B 5053

CARES Technical Approval Report TA1-B 5054

CARES Technical Approval Report TA1-B 5058

CARES Technical Approval Report TA1-B 5065

CARES Technical Approval Report TA1-B&C 5039

CARES Technical Approval Report TA1-B 5064

CARES Technical Approval Report TA1-B 5061

CARES Technical Approval Report TA7 5028

CARES Technical Approval Report TA

CARES Technical Approval Report TA2 5007

Originally Issued: 02/02/2009 Revised: 11/09/2017 Valid Through:02/28/2019

CARES Technical Approval Report TA2 5056

CARES Technical Approval Report TA2 5034

ANCON PRODUCTS FOR STRUCTURAL CONCRETE ANCON (MBT) ET-TYPE COUPLERS

ANCON (MBT) ET-TYPE COUPLERS Raccords pour armatures Verbindung für Armatur. Highways Agency Requirements. 1 Requirements.

-165 C / -265 F CRYOGENIC REBAR SPLICING SYSTEMS

Contents. Company description. Company description 1 Product description 2 Reinforcement rebar Couplers 3

Originally Issued: 02/02/2009 Revised: 07/27/2018 Valid Through: 02/28/2019

Properties of Reinforcing Steels

TERWA REBAR CONNECTION COUPLERS

TERWA REBAR CONNECTION COUPLERS. CARES Technical Approval 5058 TA1B

TAPER THREADED GRIP-TWIST

CITY OF LOS ANGELES CALIFORNIA

HRC 400 Series High Performance Reinforcement Couplers:

ISO Steels for the reinforcement of concrete Reinforcement couplers for mechanical splices of bars Requirements

Reinforcement Couplers As An Alternative To Lap Splices: A Case Study

BUILDING STRENGTH TAPER-LOCK REBAR THREADING SYSTEM CONCRETE CONSTRUCTION SOLUTIONS BROCHURE

PERFORM WITH PRECISION TAPER-LOCK REBAR THREADING SYSTEM CONCRETE CONSTRUCTION SOLUTIONS BROCHURE

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

TECHNICAL MANUAL. MODIX Rebar Coupler Safe and Flexible Rebar Coupling System

HAPAS Certificate Tel: Fax: /H271 website: Product Sheet 2

HIGH PERFORMANCE REINFORCEMENT PRODUCTS. Product Catalogue.

ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE

TCB ANTI-CORROSION PROTECTIVE COATING GREENKOTE

Building Regulations

3.1 General. 3.2 Materials. 4.1 General. Page 1 of 6

Regulations Detail Sheet 1

REINFORCING STEEL. Delete every occurrence of ASTM A 706 and replace with AASHTO M 31, Type W.

MAYER STAINLESS STEEL PRESS-FIT PIPING SYSTEM. Product. Scope. Building Regulations. Appraisal No [2018] Appraisal No.

INSTARMAC PERMANENT COLD LAY SURFACING MATERIALS ULTRACRETE INSTANT ROAD REPAIR 6 MM

Originally Issued: 04/18/2014 Revised: 05/02/2018 Valid Through: 04/30/2019

Evolution trend of reinforcement connections in concrete structures

National technical approval Coupler

Prequalification of Mechanical Splices for Reinforcing Bars in Seismic Conditions

Mechanical Rebar Splice Solutions

TRESPA WALL CLADDING SYSTEMS SYSTEM 700 ALUMINIUM SUB-FRAME SYSTEM

SIMPSON STRONG-TIE BOTTOM PLATE ANCHOR SOLUTIONS. Product. Scope. Building Regulations. Appraisal No. 983 [2018] Appraisal No.

SCHÖCK ISOKORB RANGE OF THERMAL INSULATION COMPONENTS SCHÖCK ISOKORB CONNECTORS TYPE KST MODULES

Features Advantages Benefits

International Version CI/SfB (29) Et6. June CXL Parallel Thread Couplers for the Construction Industry

Originally Issued: 09/16/2010 Revised: 05/17/2018 Valid Through: 09/30/2019. ACI , -08, or -05, the head is considered part of the bar.

Design Guide. Original version of the design guide

TECHNICAL DESIGN AND INSTALLATION GUIDE THE COMPLETE ENGINEERED SOLUTION FOR TEMPORARY MOVEMENT JOINTS

CI/SfB (29) Et6. October Starter Bar System for the Construction Industry

Features Advantages Benefits

CONSTRUCTION SPECIFICATION FOR STEEL REINFORCEMENT FOR CONCRETE

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: BARSPLICE PRODUCTS INC WEBSTER STREET DAYTON, OHIO

AS/NZS :2016. High-strength steel fastener assemblies for structural engineering Bolts, nuts and washers AS/NZS :2016

Originally Issued: 08/22/2014 Revised 03/10/2017 Valid Through: 08/31/2017

HAPAS APPROVAL INSPECTION TESTING CERTIFICATION

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SPLICE SLEEVE JAPAN, LTD.

KINGSPAN FRAME SYSTEMS KINGSPAN STEEL FRAMING SYSTEM

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110)

Regulations. Requirement: A1 Loading Comment: Requirement: B3(1) Internal fire spread (structure) Comment:

TECHNICAL MANUAL. HPKM Column Shoe Reliable Bolted Column Connections. Version: PEIKKO GROUP ACI-M 01/2017 Designed according to ACI 318M-11

R-STEEL. RPK-N2, RPK-E2 Column shoes USER GUIDE

HAPAS Certificate 18/H276 website: Product Sheet 1

RONACRETE RENDER PRODUCTS RONAFIX CONCRETE RENDER ADMIXTURE

SANDTOFT FLASHINGS KORAFLEX FLASHING SYSTEM

WYKAMOL CHEMICAL DAMP-PROOFING SYSTEMS HYDRADRY

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP SECRET JOINING STRIP (GJS 1)

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD. EVALUATION SUBJECT:

CAPITAL VALLEY PLASTICS MEMBRANES CAPITAL VALLEY PLASTICS DAMP-PROOF MEMBRANE

SECTION 552 HELICAL ANCHORS AND HELICAL PILES

NPS/002/001 Technical Specification for Earthing Materials

DAVID BALL HYDROPHILIC WATERSTOPS HDBR WATERBAR

Originally Issued: 09/16/2010 Revised: 09/15/2017 Valid Through: 09/30/ Design:

TUFFPAVE THIN SURFACING SYSTEMS FOR HIGHWAYS TUFFPAVE 10 MM THIN SURFACING SYSTEM

Premier Coatings Ltd Marley Farm Smarden Ashford Kent TN27 8PJ Tel: Fax:

TRAY-DEC FLOORING SYSTEM. Product. Scope. Building Regulations. Appraisal No. 841 [2014] Appraisal No. 841 (2014) BRANZ Appraisals

Certificate of Compliance

INGLEBEAMS. Our Inglebeam range is available in either solid aggregate versions or hollow light weight version.

1222 Moonshine Rd, RD1, Porirua 5381 Private Bag Porirua 5240, New Zealand Tel: branz.co.nz. Important Notice

INGLEBEAMS. Our Inglebeam range is available in either solid aggregate versions or hollow light weight version.

TAPER THREADED REBAR SPLICING SYSTEMS

Agrément Certificate 17/5466 website: Product Sheet 1 LEADAX FLASHINGS LEADAX

KENYA STANDARD KS 574:2017. Steel fabric for reinforcement of concrete Specification

D & B INJECTION MOULDERS LTD

Pipe Joints. Requirements and Test Methods. VdS-Guidelines for water extinguishing systems. VdS en. VdS en : (01)

Mechanical Splicing Couplers for Reinforcement

INGLEBEAMS. Our Inglebeam range is available in either solid aggregate versions or hollow light weight version.

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP ABUTMENT SECRET GUTTER/SOAKER (GAS 1)

G-FIRE GROOVED COUPLINGS

SUPERPLUS M8-M16. The undercut fixing system that does not require a special setting tool. FUNCTION BENEFITS

FERNCO PIPE CONNECTORS AND COUPLINGS FERNCO FLEXIBLE COUPLINGS

SINTEF Building and Infrastructure confirms that. HRC 700 cast-in connection system

TARMAC THIN SURFACING SYSTEMS FOR HIGHWAYS ULTIPAVE 10 D THIN SURFACING SYSTEM

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SAS STRESSTEEL INC. 100 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004

Agrément Certificate 18/5477 website: Product Sheet 1

Transcription:

CARES Technical Approval Report TA1C - 5003 Issue 3 January 2010 ERICO LENTON Mechanical Rebar Splicing System Assessment of the ERICO LENTON Taper Threaded Coupler Product, Sellafield Ltd type B Couplers and Quality System for Production 5003

Product ERICO LENTON A12, P13 and P14 mechanical couplers for reinforcing steel 1 Product Summary The products are for the mechanical connection of deformed high-yield carbon steel bars for the reinforcement of concrete complying with the requirements of BS4449 grade B500B and grade B500C. Produced by: ERICO Jules Verneweg 75, 5015 BG, Tilburg, The Netherlands 1.1 Scope of Application ERICO LENTON A12, P13 and P14 taper threaded couplers, in the size range 12mm-40mm, have been evaluated for use as follows: Static tension applications in accordance with Type B Sellafield Ltd Specification for Couplers and CARES Appendix TA1-C using B500C reinforcement only. 1.2 Design Considerations BS 8110 Clause 3.12.8.9 gives guidance on the positioning of couplers. The specified cover for fire resistance and durability should be provided to the coupler sleeve. All couplers have been designed with controlled mechanical properties to be compatible with reinforcing bars to BS4449. 1

CARES Technical Approval Report TA1C - 5003 1.3 Conclusion It is the opinion of UK CARES that ERICO LENTON A12, P13 and P14 taper threaded couplers are satisfactory for use within the stated limits when applied and used in accordance with the manufacturer s instructions and the requirements of this certificate. B. Bowsher Executive Director January 2010, Issue 3. 5003 2

2 Technical Specification 2.1 General ERICO LENTON A12, P13 and P14 taper threaded couplers are for joining deformed Grade B500B and Grade B500C steel reinforcing bars complying with BS 4449. 2.2 LENTON Type A12 The standard A12 couplers are designed for use where one of the bars to be coupled can be rotated. The 12 mm to 20 mm couplers are a one-piece hexagonal section coupler with a tapered thread machined in each end. The 25 mm to 40 mm diameter couplers are a one-piece circular section with a tapered thread machined in each end. 2.3 Types P13 and P14 The P13 and P14 three-piece positional couplers are for use where neither of the bars to be coupled can be rotated. The P13 coupler is specifically used when the bar to be coupled are also restricted in their axial movement. The three components comprise male and female ends with internal taper threads, connected by a female and male parallel threads and locknut. The male section is hexagonal in cross section for12 mm to 20 mm couplers. The female section is circular in cross section for 25 to 40 mm. The female section is hexagonal in cross section for 12 to 16 mm couplers and circular in cross section for 20 to 40 mm. Positional P13 Coupler D Standard A12 Coupler D B KEY A = diameter B = length of coupler body D = bar engagement Fc = connector and jam nut (closed position) length Max. Fo = connector and jam nut (fully open position installed) length A A B F c Max. Fo 3

CARES Technical Approval Report TA1C TA1-B-5012-5003 The dimensions for the A12 coupler are as follows: Size Part Art A B D Weight mm No No mm mm mm kg 12 EL12A12 150010 17* 49 19 0.06 16 EL16A12 150030 22* 61 24 0.12 20 EL20A12 150050 27* 88 36 0.26 25 EL25A12 150070 33 96 41 0.35 32 EL32A12 150100 42 107 46 0.60 40 EL40A12 150140 52 131 58 1.12 *Use hexagonal material (measured across the flats), others use round material The dimensions for the P13 coupler are as follows: Size Part Art A B Fc Fo D Weight mm No No mm mm mm mm mm kg 12 EL12P13 150190 22* 77 42 85 19 0.29 16 EL16P13 150210 27* 88 48 93 24 0.50 20 EL20P13 150230 33 112 63 116 36 0.87 25 EL25P13 150250 41 127 68 128 41 1.31 32 EL32P13 150280 52 144 79 144 46 2.38 40 EL40P13 150320 64 179 91 172 58 4.34 *Use hexagonal material (measured across the flats), others use round material The dimensions for the P14 coupler are as follows: Size Part Art A B Fc Fo D Weight mm No No mm mm mm mm mm kg 12 EL12P14 150370 22* 45 42 53 19 0.20 16 EL16P14 150390 27* 54 48 59 24 0.35 20 EL20P14 150410 33 75 63 79 36 0.64 25 EL25P14 150430 41 83 68 84 41 0.96 32 EL32P14 150460 52 95 79 95 46 1.77 40 EL40P14 150500 64 114 91 107 58 3.07 *Use hexagonal material (measured across the flats), others use round material 5003 4

3 Product Performance and Characteristics Full destructive tests have been carried out to demonstrate compliance with performance requirements defined in CARES Appendix TA1-C including the performance requirements of BS8110 and the Sellafield Ltd Specification for Couplers when used with reinforcing bars to BS4449: CARES APPENDIX TA1-C Permanent deformation is less than 0.1mm at 300 MPa in tension. Tensile strength is greater than 575 MPa for Grade B500C and greater than the load required to produce 2% strain in the reference bars. Cyclic loading of 100 cycles between 5% and 90% fy. Reduced temperature performance at -7 C. Mechanical splicing provides the assurance of maintaining load path continuity of the structural reinforcement independent of the condition or existence of the concrete Lap splices rely on bond with the concrete for effective continuity of reinforcement, which can result in localised areas of increased concrete stress that must be considered by the designer 5

CARES Technical Approval Report TA1C TA1-B-5012-5003 4 Installation The bars to be threaded must be cut square and threaded, using ERICO LENTON equipment and suitably trained and experienced operatives in accordance with LENTON operating instructions. These operators will have an ERICO LENTON Training Certificate. It is essential that the joints be tightened to the correct torque mentioned in the installation manual, using the appropriate LENTON torque wrench. 4.1 Type A12 Coupler A12 Couplers are for connecting reinforcing bars where one of the bars forming the splice is free to turn. The parts are screwed together by hand and tightened to the correct torque. Where the coupler forms a stop end, it must be torque tightened to the reinforcing bar. When the joint is to be made the continuation bar is screwed into the coupler by hand and tightened to the correct torque. The continuation bar must be able to rotate freely. A12 Coupler 5003 6

4.2 Type P13 Coupler P13 Couplers are for connecting cages, crowns of arches, or bars positioned and essentially unable to move. The P13 coupler can be adjusted in length to connect to the second bar. It must be ensured that the coupler is fully screwed together and tightened onto the first bar. The cage or other bar is brought into its final position ensuring that the gap between it and the coupler is not greater than 10-25 mm depending on the used size of rebar. The male part is screwed out to engage the tapered thread of the ongoing bar and then fully tightened. The lock-nut is spun back and fully tightened against the body of coupler. It must be ensured that the limit groove on the male section is not fully visible above the lock-nut. P13 & P14 Couplers 4.3 Type P14 Coupler Limit groove P14 Couplers are for connecting onto a bent bar or a bar that cannot be rotated. It must be ensured that the male part is fully screwed into the female part and the female part is tightened onto the first bar. The taper-threaded bent bar is inserted into the mouth of the coupler as far as possible. The male part is screwed out of the female part to engage the taper-threaded bar and is tightened. The lock-nut is spun back to coupler body and fully tightened against the coupler body after setting the bent bar to the required position. It must be ensured that the limit groove is not fully visible above the lock-nut. 7

CARES Technical Approval Report TA1C TA1-B-5012-5003 5 Safety Considerations Care must be taken in handling and installing couplers. Couplers are supplied in containers that have a maximum weight of 25kg. It is advisable to wear protective gloves during handling the containers, threaded bars and installing the couplers. 6 Product Testing and Evaluation ERICO LENTON taper threaded couplers have been tested to satisfy the requirements of BS8110 and Sellafield Ltd Specification for Couplers, when used with reinforcing bars to BS4449. The testing comprised the following elements: Sellafield Ltd Specification for Couplers Tensile Strength* Permanent Deformation* Cyclic Loading *Low temperature testing at -7 C was included Testing has been undertaken at Bureau Veritas. The products are subject to a programme of periodic testing to ensure that they remain within the performance limits of this technical approval. 7 Quality Assurance ERICO LENTON taper thread couplers are produced under an ISO9001 quality management system certified by an independent certification body. The quality assurance scheme monitors the production of the couplers and ensures that materials and geometry remain within the limits of this technical approval. 5003 8

8 Building Regulations 8.1 The Building Regulations (England and Wales) Structure, Approved Document A ERICO LENTON A12, P13 and P14 taper threaded couplers, when used in BS8110 based designs using the data contained within this technical approval, satisfy the relevant requirements of The Building Regulations (England and Wales), Approved Document A. Materials and Workmanship, Approved Document, to support regulation 7 This technical approval gives assurance that the ERICO LENTON taper threaded couplers comply with the material requirements of BS8110. 8.2 The Building Regulations (Northern Ireland) Part B, Materials and Workmanship This technical approval gives assurance that ERICO LENTON taper threaded couplers comply with the material requirements of BS8110 by virtue of regulation B3, Deemed to satisfy provisions regarding the fitness of materials and workmanship. 8.3 The Building Standards (Scotland) Regulations Part B, Fitness of Materials This technical approval gives assurance that ERICO LENTON taper threaded couplers comply with the material requirements of BS8110 by virtue of Clause B2.1. Part C, Structure ERICO LENTON taper threaded couplers, when used in BS8110 based designs using the data contained within this technical approval, satisfy the requirements of The Building Standards (Scotland) Regulations 1990, Part C, C2.1 clause b. construction,ii. 9

CARES Technical Approval Report TA1C TA1-B-5012-5003 9 References BS 4449: 2005: Steel for the reinforcement of concrete - Weldable reinforcing steel - Bar, coil and decoiled product - Specification BS 8110: Part 1: 1997 (Revised 2005): Structural Use of Concrete, Code of Practice for Design and Construction BS EN ISO 9001: 2000: Quality management systems - Requirements Sellafield Ltd Technical Standard: A.0391_1: Mechanical Splices to Reinforcement for Concrete TA1-C Quality and Operations Schedule for the Technical Approval of Tension Couplers for Reinforcing Steel for Sellafield Ltd Standard Applications 5003 10

10 Conditions 1. The quality of the materials and method of manufacture have been examined by CARES and found to be satisfactory. This technical approval will remain valid provided that: a The product design and specification is unchanged. b The materials and method of manufacture are unchanged. c The manufacturer complies with CARES regulations for technical approvals. d The manufacturer holds a valid CARES Certificate of Product Assessment. e The product is installed and used as described in this report. 2. CARES make no representation as to the presence or absence of patent rights subsisting in the product and/or the legal right of ERICO to market the product. 3. Any references to standards, codes or legislation are those which are in force at the date of this certificate. 4. Any recommendations relating to the safe use of this product are the minimum standards required when the product is used. These requirements do not purport to satisfy the requirements of the Health and Safety at Work act 1974 or any other relevant safety legislation. 5. CARES does not accept any responsibility for any loss or injury arising as a direct or indirect result of the use of this product. 6. This Technical Approval Report should be read in conjunction with CARES Certificate of Product Assessment No 5003. Confirmation that this technical approval is current can be obtained from UK CARES. 11

UK CARES Pembroke House 21 Pembroke Road Sevenoaks Kent TN13 1XR Phone: +44(0)1732 450000 Fax: +44(0)1732 455917 E-mail: general@ukcares.com URL: www.ukcares.com Independent Product Assessments for the Construction Industry Copyright UK CARES