Addendum # 6. Date: March 16, 2017 RFT Construction of New Building Addition to the Town of Caledon Yard 1 Garage Building

Similar documents
LUX Specifications. Section S - Preformed Steel Siding

A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

Architectural Wall Products Guide Specifications

SECTION ROOF SPECIALTIES

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

Specifications for FL-100 Soffit Panel

SECTION COPPER STANDING SEAM ROOFING

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Architectural Roof and Wall Products Guide Specifications

Architectural Roof Products Guide Specifications

DISVISON 8: DOORS, WINDOWS AND GLASS SECTION 07600: SHEET METAL FLASHING AND TRIM

SSL-175. Specifications

Architectural Roof and Wall Products Guide Specifications

DL-200. Specifications

SECTION METAL ROOF AND SOFFIT PANELS

DIVISION 7 THERMAL AND MOISTURE PROTECTION

Architectural Roof Products Guide Specifications

Sheet Metal Flashing and Trim

SECTION SHOWER AND DRESSING COMPARTMENTS

Hawthorne Fire Station Repairs Section Page 1 of 8

Distributed by: BEST MATERIALS LLC Ph: , Fax:

This specification is based on recognized manufacturer s specifications and guidelines for prefinished steel wall systems.

SECTION ALUMINUM WINDOWS

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

CR# August 20, 2015

SECTION COILING COUNTER DOORS

SECTION FLASHING AND SHEET METAL

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

SECTION MISCELLANEOUS METALS THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION MISCELLANEOUS AND ORNAMENTAL IRON

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

Corium Brick Rainscreen System Specifications

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

This Addendum forms part of the Tender Documents and amends the Tender Documents as described below.

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

HOTEL SPECIFICATION SECTION 08100

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Section Bituminous Dampproofing Page Whapmagoostui Warehouse Addition New Design August General

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

The better way to build TM. Installation Manual NAILBASE PANELS

Project No: Pakenham Branch Library, Pakenham, Ontario Section January, 2017 Page 1 of 7

1. Rough Carpentry for wood nailers, cants, curbs, and blocking and for wood-based, structural-use roof deck and walls: Division 6.

Light-Metal Roof Edge, Raised

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION METAL LOCKERS

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

SECTION FLASHING AND SHEET METAL

SPECIFICATION GUIDELINE

SECTION MISCELLANEOUS METALS

Architectural Roof and Wall Products Guide Specifications

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

1. SPECIFICATIONS SECTION FLASHING AND SHEET METAL

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS

SECTION ROOF SPECIALTIES

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY)

SECTION BLAST RESISTANT WINDOWS

SECTION DETAILS (MECHANICALLY ASSEMBLY)

SPECIFICATION GUIDELINE

SECTION METAL ATHLETIC LOCKERS

1. Standard two tier metal lockers and metal base.

SECTION METAL WALL PANEL SYSTEM

The City of Winnipeg SECTION ST. VITAL LIBRARY RENOVATION PROJECT 6 FERMOR AVE. Page 1 of 5

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION ROUGH CARPENTRY. B. AWPA (American Wood Preservers Association) Book of Standards. C. WCLIB (West Coast Lumber Inspection Bureau)

SECTION HVAC GRAVITY VENTILATORS

Product Guide Specification

SECTION ASPHALT SHINGLE ROOFING SYSTEMS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

NOTICE TO BIDDERS OF RECORD

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Project No: Pakenham Branch Library, Pakenham, Ontario Section

SECTION EXTERIOR METAL WALL PANELS SERIES PF

Octaform Quick Liner Wall & Ceiling Panels Guide Specification CAN Page 1

Bid Opportunity Wilkes Reservoir North Cell Rehabilitation

.1 Section Documents and samples to be submitted..2 Section Construction and demolition waste management and disposal.

Omniplate Barrier Wall System

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

SECTION ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.


Transcription:

Addendum # 6 Date: March 16, 2017 RFT 2017-08 Construction of New Building Addition to the Town of Caledon Yard 1 Garage Building Closing Date: Friday, March 17, 2017 2:00 PM This addendum refers to additions, deletions, modifications and clarifications which hereby become an integral part of the original Bid Documents and Contract Documents and shall be read in conjunction with the same. No consideration will be allowed for extras to the contract due to the Bidder not being familiar with this Addendum. Question and Responses Question 1: Response 1: Addenda 3, 4 and 5 still do not indicate eight of exterior (OUTSIDE) chain link fence. Please provide material to use, height and if a gate is required to access the enclosed area which holds heat pumps and cistern. Exterior chain link fence to comply to enclosed details OPSD972.102, OPSD972.130 and OPSD972.132. Fence to be manufactured by Acculink Fence & Wire Inc. or approved similar. Provide 6ft high fence with overhead bracing and a 4ft wide gate. Provide 4ft deep concrete foundation at post locations and ensure the post doesn t heave. Question 2: Response 2: Gauge of 7/8" corrugated metal panel by Westman still not provided. Please provide. Do we use 24, 26, 29, is it galvanized or is it colour finish? There was a typo in specification header. Specification pages #187-190 are titled Section 10 21 13.19 Plastic Toilet and Shower Compartments, and shall be replaced with enclosed Section 07 62 00 Sheet Metal Flashing and Trim. Corrugated metal fascia shall be 24ga and painted to color finish from manufacturer s standard colors. RFT 2017-08 Addendum 6 Page 1 of 2

Question 3: Response 3: Please provide material, gauge, supplier and finish for vented metal soffit at overhang location. Please confirm if we are to match adjacent Westman metal siding as indicated in question 2 above? Vented metal soffit to match Westman siding, gauge and color. Please acknowledge receipt of Addendum #6 on the Form of Offer. Irene Shepherd Buyer Finance & Infrastructure Services Department RFT 2017-08 Addendum 6 Page 2 of 2

Town of Caledon Architectural Specifications Specifications CALEDON YARD #1 Section 07 62 00 Paul Didur Architect 8820 Castlederg Side Road, Bolton, ON, L7E 0S1 Sheet Metal Flashing and Trim 1. GENERAL Summary Work of this section consists of sheet metal flashing and trim for new building s fascia and soffit. 1.1 Related Sections 1.1.1 Section 01 33 00 Submittal Procedures 1.1.2 Section 06 10 00 Rough Carpentry. 1.1.3 Section 07 52 00 SBS Modified Bituminous Membrane Roofing. 1.1.4 Section 07 92 00 Joint Sealants 1.1.5 Section 08 11 10 Metal Doors and Frames 1.1.6 Section 08 11 16 Aluminum Doors and Frames 1.1.8 Section 08 44 13 Glazed Aluminum Curtain Walls 1.1.8 Section 08 50 00 Aluminum Windows 1.1.9 Structural Specifications 1.1.10 Mechanical Specifications 1.2 References 1.2.1 The Aluminum Association Inc. (AAI):.1 AAI-Aluminum Sheet Metal Work in Building Construction-2002..2 AAI DAF45-03, Designation System for Aluminum Finishes. 1.2.2 American Society for Testing and Materials International (ASTM):.1 ASTM A 167-99 (2004), Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet and Strip..2 ASTM A 240/A 240M-07e1, Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications..3 ASTM A 606-04, Standard Specification for Steel, Sheet and Strip, High- Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, with Improved Atmospheric Corrosion Resistance..4 ASTM A 653/A 653M-07, Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process..5 ASTM A 792/A 792M-06a, Standard Specification for Steel Sheet, 55 per cent Aluminum-Zinc Alloy-Coated by the Hot-Dip Process..6 ASTM B 32-04, Standard Specification for Solder Metal..7 ASTM B 370-03, Standard Specification for Copper Sheet and Strip for Building Construction..8 ASTM D 523-89 (1999), Standard Test Method for Specular Gloss..9 ASTM D 822-01 (2006), Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of Paint and Related Coatings. 1.2.3 Canadian Roofing Contractors Association (CRCA):.1 Roofing Specifications Manual 1997. 1.2.4 Canadian General Standards Board (CGSB):.1 CAN/CGSB-51.32-M77, Sheathing, Membrane, Breather Type..2 CAN/CGSB-93.1-M85, Sheet Aluminum Alloy, Pre-finished, Residential. 1.2.5 Canadian Standards Association (CSA International):.1 CSA A123.3-05, Asphalt Saturated Organic Roofing Felt..2 AAMA/WDMA/CSA 101/I.S.2/A440-2008, Standard/Specification for Windows, Doors and Unit Skylights..3 CSA B111-1974 (R2003), Wire Nails, Spikes and Staples. 1.2.6 Health Canada/Workplace Hazardous Materials Information System (WHMIS):.1 Material Safety Data Sheets (MSDS). 1.3 Action and Informational Submittals 1.3.1 Provide submittals in accordance with Section 01 33 00 Submittal Procedures. 1.3.2 Product Data: 1

Town of Caledon Architectural Specifications Specifications CALEDON YARD #1 Section 07 62 00 Paul Didur Architect 8820 Castlederg Side Road, Bolton, ON, L7E 0S1 Sheet Metal Flashing and Trim.1 Submit manufacturer's printed product literature for sheet metal flashing systems materials, specifications and datasheet and include product characteristics, performance criteria, physical size, finish and limitations..2 Submit two copies WHMIS MSDS Material Safety Data Sheets. 1.3.3 Samples: Submit two 100mm x 100mm samples of each type of sheet metal material, finishes and colours. 1.4 Delivery, Storage and Handling Deliver, store and handle materials in accordance with Section 01 61 00 Common Product Requirements. 2. PRODUCTS 2.1 Pre-Finished Aluminum Sheet 2.1.1 Finish: Factory applied coating to CAN/CGSB-93.1 supplemented and amended as follows:.1 Type 1..2 Class F1S..3 Colour from manufacturer's standard range to later selection by Architect..4 Specular gloss: 30 units..5 Coating thickness: not less than 22 micrometres..6 Outdoor exposure period: 2500 hours..7 Exposure period for humidity resistance: 5000 hours..8 Exposure period for salt spray resistance: 1000 hours. 2.1.2 Thickness specified for pre-finished aluminum sheet applies to base metal. 2.2 Metal Flashings, Copings and Fascias 2.2.1 Form factory pre-painted flashings, copings and fascias to profiles indicated of 0.80mm (0.032 ) thick pre-finished aluminum. 2.2.2 Fascias to be:.1 24ga, 7/8 corrugated panel by Westman Steel or approved equal. Contact Rep: Tracy Thibideau, 1-519-620-6001 ext 1530, tthibideau@westmansteel.ca.2 Factory painted to color by later selection by Architect..3 Fasteners: SD Tek screws at spacing as recommended by manufacturer..4 Header drip flashing and sill J flashing at window headers and sills..5 Provide outside J corner metal flashings in color matching the fascia.6 Provide inside J corner metal flashings in color matching the fascia 2.3 Accessories 2.3.1 Isolation coating: Alkali resistant bituminous paint. 2.3.2 Plastic cement: to CAN/CGSB 37.5. 2.3.3 Underlay for metal flashing: Dry sheathing to CAN/CGSB-51.32 or as noted on the Contract Drawings. 2.3.4 Sealants: Refer to Section 07 92 00 Joint Sealants. 2.3.5 Cleats: of same material and temper as sheet metal, minimum 50mm wide. Thickness same as sheet metal being secured. 2.3.6 Fasteners: of same material as sheet metal, to CSA B111, flat head roofing nails of length and thickness suitable for metal flashing application. 2.3.7 Washers: of same material as sheet metal, 1mm thick with rubber packings. 2.3.8 Flux: Rosin, cut hydrochloric acid or commercial preparation suitable for materials to be soldered. 2.3.9 Touch-up paint: as recommended by pre-finished material manufacturer. 2

Town of Caledon Architectural Specifications Specifications CALEDON YARD #1 Section 07 62 00 Paul Didur Architect 8820 Castlederg Side Road, Bolton, ON, L7E 0S1 Sheet Metal Flashing and Trim 2.4 Fabrication 2.4.1 Fabricate metal flashings and other sheet metal work as indicated in the Contract Drawings. 2.4.2 Fabricate aluminum flashings and other sheet aluminum work in accordance with AAI- Aluminum Sheet Metal Work in Building Construction. 2.4.3 Form pieces in 2400mm maximum lengths: Make allowance for expansion at joints. 2.4.4 Hem exposed edges on underside 12mm: Mitre and seal corners with sealant. 2.4.5 Form sections square, true and accurate to size, free from distortion and other defects detrimental to appearance or performance. 2.4.6 Apply isolation coating to metal surfaces to be embedded in concrete or mortar. 2.5 Reglets and Cap Flashings 2.5.1 Form metal cap flashing of 0.80mm (0.032 ) thick pre-finished aluminum sheet metal. Provide slotted fixing holes and steel/plastic washer fasteners. 2.6 Eavestroughs and Downpipes 2.6.1 N/A 2.7 Scuppers 2.7.1 Form scuppers from 0.80mm (0.032 ) thick pre-finished aluminum. 2.7.2 Sizes: 6 square profiles. Refer to Architectural Contract Drawings for quantities and locations. 2.7.3 Provide necessary fastenings. 2.7.4 Provide 2 thick x 13 long chain link fastened to scupper at Entrance Canopy near Door D103. 3. EXECUTION 3.1 Manufacturer s Instructions 3.1.1 Compliance: Comply with manufacturer's written recommendations, including product technical bulletins, handling, storage and installation instructions and datasheets. 3.2 Installation 3.2.1 Install sheet metal work in accordance with AAI-Aluminum Sheet Metal Work in Building Construction and as detailed. 3.2.2 Use concealed fastenings except where approved before installation. 3.2.3 Provide underlay under sheet metal:.1 Secure in place and lap joints 100mm. 3.2.4 Counterflash bituminous flashings at intersections of roof with vertical surfaces and curbs:.1 Flash joints using S-lock forming tight fit over hook strips, as detailed. 3.2.5 Lock end joints and caulk with sealant. 3.2.6 Install surface mounted reglets true and level and caulk top of reglet with sealant. 3.2.7 Insert metal flashing into reglets under cap flashing to form weather tight junction. 3.2.8 Turn top edge of flashing into recessed reglet or mortar joint minimum of 25mm. Lead wedge flashing securely into joint. 3.2.9 Caulk flashing at cap flashing with sealant. 3.2.10 Install pans, where shown around items projecting through roof membrane. 3.3 Eavestrough and Downpipes 3.3.1 N/A 3.4 Scuppers 3.4.1 Install scuppers where indicated. 3

Town of Caledon Architectural Specifications Specifications CALEDON YARD #1 Section 07 62 00 Paul Didur Architect 8820 Castlederg Side Road, Bolton, ON, L7E 0S1 Sheet Metal Flashing and Trim 3.5 Cleaning 3.5.1 Proceed in accordance with Section 01 74 11 Cleaning. 3.5.2 On completion and verification of performance of installation, remove surplus materials, excess materials, rubbish, tools and equipment. 3.5.3 Leave work areas clean, free from grease, finger marks and stains. END OF SECTION 4