Bulletin Solar Hot Water Ready Requirements

Similar documents
SOLAR HOT WATER READY REGULATION

2018 British Columbia Building Code Public Review of Proposed Changes

LOCAL GOVERNMENT ACTIONS ON CLIMATE CHANGE & SUSTAINABILITY

Fall 2018 Builder & Designer Breakfast

Truss Plate Institute of Canada

Technical Bulletin #1 : Evaluating roofs for solar

BC Energy Step Code Feasibility Review for the City of Abbotsford

In addition to standard plan requirements, all plans submitted for PV installation shall include the following details:

Preparing for the Impacts of Climate Change on Local Government Flood Management in the Lower Mainland

This permit is issued under OAR Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days.

Status of Ground-Level Ozone in B.C. ( 4-6)

VILLAGE OF BETHUNE BYLAW NO. 3/2010

INFORMATION BULLETIN

SERVICES AND. Topic: requirements. installations. service pole met; and. braced. Page 1 of 9

Implications of Rising Sea Levels and a Lower Mainland Flood Management Strategy. Environmental Managers Association of BC Vancouver, BC

Administrative Changes

Section 7.25 REGULATION OF SOLAR FARMS AND SOLAR PANELS

Building Permits A Guide for Homeowners

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.

Practice Note 16: Professional Design and Field Review By Supporting Registered Professionals

Live Load Considerations for Truss Bottom Chords

City of Santa Monica. Building and Safety Division. Structural Criteria for Residential Rooftop Solar Energy Installations

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER'S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

Supplementary Standard SB-12. Energy Efficiency For Housing

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

The requirements set forth in this Section shall govern the construction and/or installation of all Renewable Energy Systems:

Partners for Climate Protection Program. A Presentation to Council The Village of Belcarra April 22, 2002

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

District of Ucluelet Building Permit Guide

BUILDING A NEW HOME. Construction Permit Tips For Home Owners

HALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

BERNALILLO COUNTY SOLAR PACKET

SOLAR PACKET BUILDING SECTION SOLAR PACKET. This packet contains: Building Permit Application. Solar Installation Requirements

LIQUID WASTE. Guide to Managing Wastewater. Swimming Pools and Ice Rinks

District of Barriere A GUIDE TO BUILDING PERMITS

INCORPORATED VILLAGE OF OYSTER BAY COVE BUILDING DEPARTMENT 68 WEST MAIN ST., OYSTER BAY NEW YORK (516)

LIQUID WASTE. Guide to Managing Wastewater. Automotive Repair Industry

Village of Glencoe 675 Village Court, Glencoe, Illinois

Residential Patio Cover Specifications

ILLUSTRATED GUIDE. Energy Efficiency Requirements for Houses in British Columbia. Climate Zone 4 Lower Mainland and Southern Vancouver Island

Structural Criteria for Residential Rooftop Solar Energy Installations

Town of Kingsville. Building Department

2010 National Building Code Adoption and Associated Process Changes

GUIDELINES FOR PLAN CHECK AND PERMIT REQUIREMENTS FOR SOLAR ENERGY SYSTEMS

Status of Ground-Level Ozone in B.C. ( )

BUILDING DEPARTMEN T

Guidelines for planning the construction of a porch.

DOCK CONSTRUCTION GUIDE

Michigan Truss Design Drawing Submittals at Time of Permit Application Two-Step Market

Structural Criteria for Residential Rooftop Solar Energy Installations

Open Data Sources Definitions and Data Qualifiers

FLOOD PLAIN STANDARDS AND REQUIREMENTS. Adopted by City Council on September 16, 2014 Effective January 1, 2015

REGULAR COUNCIL. TO: Mayor & Council DATE: October 25, FROM: City Solicitor FILE: /#11. Inter-Municipal Business License Pilot Program

Residential Building Permits

Understanding the roof top access and ventilation requirements as described in Section R324 of the 2015 International Residential Code

Structural Criteria for Residential Rooftop Solar Energy Installations

A guide to: ACCESSORY BUILDINGS. Brought to you by: City of Port Colborne - Building Division

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Structural Criteria for Residential Rooftop Solar Energy Installations

LIQUID WASTE. Guide to Managing Wastewater. Commercial Vehicle Washing Industry

Structural Criteria for Residential Rooftop Solar Energy Installations

Are You Ready for Solar-Ready? And Other Energy Code Updates Residential Massachusetts Energy Code Technical Support Program

Structural Criteria for Residential Rooftop Solar Energy Installations

PHOTOVOLTAIC ready Guidelines

WTCA 6300 Enterprise Lane Madison, WI / / (fax)

GUIDELINES FOR SOLAR WATER HEATERS INSTALLATION

PERMITS REQUIRED BEFORE OBTAINING A PERMIT

REINFORCING TABLES INSTALLATION MANUAL

GUIDE FOR APPLYING FOR A BUILDING PERMIT

SOUTHERN NEVADA AMENDMENTS TO THE 2018 UNIFORM MECHANICAL CODE

Structural Criteria for Residential Rooftop Solar Energy Installations

CITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS

TOWN OF ROTTERDAM BUILDING DEPARTMENT RESIDENTIAL ACCESSORY BUILDINGS AND STRUCTURE PERMIT APPLICATION Ext 395

The Homeowner s Building Application Checklist for Constructing a Residential Addition

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

BC Local Government Attitudes Towards the Legalization and Regulation of Marijuana in Canada

Structural Criteria for Residential Rooftop Solar Energy Installations

DETACHED GARAGES. Construction requirements for detached garages and storage sheds for residential dwellings. Portage la Prairie Planning District

Chapter 1: Compliance

Development Advisory - 40 March 21, 2018

1569 West 6th Avenue By-law No (Being a By-law to Amend By-law 3575, being the Zoning and Development By-law)

meters (16 Inches) Transportation (T)

Mayor and Council Barry Azevedo, Solid Waste and Environmental Engineer Award of Contract Eastside Curbside Collection Services

MARBLEHEAD FIRE DEPARTMENT Standard Operating Guideline Draft for Photovoltaic/Solar Installations

BUILDING DEPARTMENT GUIDE TO RESIDENTIAL BUILDING PERMITS

CSA Z Technical Requirements for Manufactured Homes Implications of the More Significant Proposed Changes

Municipal Organic Waste Diversion and Composting in Metro Vancouver

Portola Valley Green Building Ordinance Build It Green, GreenPoint Rating Point Requirements*

Guide to the Letters of Assurance in the B.C. Building Code 2006 December, 2010 Edition 5

Individual Truss Marking Is it a Building Code Requirement?

NY State Unified Solar Permit

Detached garages/ Sheds/ Gazebo s

INTERNATIONAL CODE COUNCIL (ICC) Code Technology Committee (CTC) INTERIM REPORT NO. 1 OF THE CTC AREA OF STUDY REVIEW OF NIST WTC RECOMMENDATIONS

Executive Summary. Enhancing Patron Experience. Building member library capacity. Increasing Awareness of the Impact of Public Libraries

Transcription:

Bulletin Solar Hot Water Ready Requirements NUMBER 11-05 Created: June 15, 2013 Updated: July 29, 2011 This bulletin is for informational purposes only. Please be sure to consult the relevant City of Kelowna bylaw. PURPOSE This bulletin is to inform staff, owners, retailers, installers, builders, designers and contractors of the Solar Hot Water Ready requirement for single family homes. BACKGROUND The Solar Hot Water Ready requirements for single family homes is one of the steps the Province is taking in fulfilling its promise for climate action. The City of Kelowna and all other communities that have requested inclusion by municipal council resolution are required to follow the regulation. Designers are required to identify the location of solar panels on the roof surface for future installations. Contractors/builders are required to install the specified conduit at framing stage so that the installation can be verified by the plumbing inspector at rough in plumbing inspection. SOLAR HOT WATER READY REGULATION Definitions 1 In this regulation, the terms in italics have the same meaning as in the British Columbia Building Code. Application 2 This regulation is applicable in the following local government jurisdictions: (j) City of Kelowna (see regulation for all other applicable jurisdictions) *Subsections 3, 4 and 5 are included in the attached Guide issued by the Province of BC for Solar Hot Water Ready Regulation. IMPLEMENTATION All permits applied for on or after October 25, 2011 for single family dwellings and/or accessory buildings containing a secondary suite must meet The Solar Hot Water Ready Regulation. Building & Permitting 1435 Water Street Kelowna, BC V1Y 1J4 TEL 250 469-8960 FAX 250 862-3314 kelowna.ca

Guide to the Province of BC Solar Hot Water Ready Regulation 2013

Introduction This guide is intended to clarify the application of the Solar Hot Water Ready Regulation. The regulation is currently set out in two parts: the original BC Regulation 101/2011 and the amendment, BC Regulation 163/2013. For convenience, the appendix to this guide includes a consolidated version of the two regulations. The guide does not form part of the regulation, but is intended to provide further information on the installation of rough-ins for solar domestic hot water systems (SDHWS). Some information is also provided related to installation of a SDHWS. With this kind of information it is hoped that users will have a better understanding of the regulation requirements for future installation of a solar domestic hot water system. It must, however, be clearly understood that the explanatory text contained in the guide cannot be construed as providing legal interpretations of requirements contained in the regulation. The text extracted from the Solar Hot Water Ready Regulation is printed on a shaded background. Explanatory text is written below each shaded section. Comments on this guide are welcome. Please submit to Building.Safety@gov.bc.ca. May 2013 2 nd Edition Office of Housing and Construction Standards Page 1

BC Regulation 163/2013 Definitions 1 In this regulation, the terms in italics have the same meaning as in the 2012 British Columbia Building Code. Application 2 This regulation applies to the local government jurisdictions set out in the Schedule. Sections 1 and 2 of the regulation are self explanatory. Solar collectors for a solar domestic hot water system 3 (1) Subject to subsection (2), 2 conduit runs and an area that (a) is not less than 9.3 square meters, (b) has no dimensions less than 2.7 meters, and (c) is designated for future installation of solar collectors for a solar domestic hot water system in compliance with CAN/CSA-F383-87 must be incorporated in construction of new buildings of residential occupancy that contain (a) one dwelling unit, or (b) one dwelling unit and one secondary suite. Section 3 describes the requirement to provide for the future installation of a solar domestic hot water system. This is the requirement to allocate an area on or near the building that will be designated for the future installation of solar hot water collectors (also known as solar panels or solar collectors). The designated area is approximately the size of 2 typical solar hot water collectors. Solar collectors may be installed on a roof, wall, building lot, or accessory building such as a garage. A roof area directly above an accessible attic space is the preferred location for solar hot water collectors. Section 3 also requires that 2 conduit runs (typically but not necessarily run in parallel) be incorporated into construction of solar ready homes. The specifications for conduit runs are described further in section 5. The latter part of Section 3, Subsection (1) specifies that the regulation applies only to detached single family homes, and detached single family homes containing a secondary suite as defined in the BC Building Code. Office of Housing and Construction Standards Page 2

(2) Subsection (1) does not apply with respect to new construction referred to in that subsection if the local government of the jurisdiction to which this regulation applies and within which the new construction is to occur is satisfied that building site conditions do not permit effective use of solar hot water heating. Section 3, Subsection (2) describes where the regulation does not apply. If a building site is unsuitable for a solar domestic hot water installation, and it is therefore not anticipated that a rough-in will be used in future, a building owner may discuss with the local government having jurisdiction if this exemption to could be applied in their case. This exemption is intended for buildings that are in permanent shade, such as from a tall building or tall trees adjacent to the south side. It is not the intent of this regulation to require removal of objects that may shade a potential area designated for installation of a solar collector. All options for alternate placement of the area designated for installation of a solar collector should be examined prior to applying this exemption. Note that a home s roof slope and orientation may not necessarily need to be altered to accommodate installation of a solar hot water collector, as rack mounting systems are available. However, in this case, it would be known that the future solar collectors will not be directly surface-mounted. This has direct implications in the application of Section 4(2) later on in the regulation. The regulation is designed to accommodate as many potential areas designated for installation of a solar collector as possible including roofs, walls, building lots and accessory buildings. Local governments are ultimately responsible for the decision and any administrative process involved in determining whether a building site qualifies for an exemption to the regulation. Office of Housing and Construction Standards Page 3

Structural requirements 4 (1) Except as permitted by subsection (2) of this section, structural members located in areas referred to in section 3 (1) must be designed to accommodate (a) a uniform dead load of 0.24 kpa, in addition to design loads required by the British Columbia Building Code, and (b) anticipated point loads where it is known that the solar collectors for a solar domestic hot water system will not be directly surfacemounted. (2) Roof trusses located in areas referred to in section 3 (1) must be designed to accommodate the anticipated load, including (a) a uniform dead load of 0.24 kpa, in addition to design loads required by the British Columbia Building Code, and (b) point loads resulting from the uniform dead load referred to in paragraph (a). Typically, designers must determine or calculate certain values (such as but not limited to snow load or clear spans) in order to specify the appropriate materials. The regulation requires designers to add an additional load value into the calculations. Note that roof mounted solar collectors are often mounted with brackets spaced two or four feet apart. They do not transfer their weight evenly to the roof structure. This creates point loading on to the structural members of the roof. This situation is exacerbated if snow accumulates on the solar collector. A structural member to which the bracket is attached beneath the solar collectors must be designed to accommodate this additional load. The requirements differ if the roof is constructed with roof joists or rafters versus roof trusses, as explained below. Roof Joists or Rafters and Other Structural Members Section 4, Subsection (1) describes the additional loading requirements for roof joists or rafters and other structural members (such as a wall designated for a solar collector). If you are constructing a roof using conventional roof joists or roof rafters, the starting point is to assume that the solar collector will bear directly on the roof and only the uniform load of 0.24 kpa (in addition to snow load) is required to be accommodated in the design of the roof area. In this case, it is assumed that the load of future solar collectors will be evenly distributed along the roof rafter or joist. If it is known that the solar collector will sit on a rack or brackets above the roof surface, point loads should also be considered. Office of Housing and Construction Standards Page 4

Since the BC Building Code s Part 9 span tables for roof joists and rafters are not designed to accommodate point loads, an engineer may be required to calculate anticipated point loads where it is known that the solar collectors will not be directly surface-mounted for roof joists or rafters. Other structural members (such as a wall designated for a solar collector) must also be designed to accommodate a minimum additional load of 0.24 kpa. Roof Trusses Section 4, Subsection (2) describes the additional loading requirements for roof trusses. If you are constructing a Solar Hot Water Ready roof using conventional roof trusses, an additional load must be incorporated into the design of the trusses. In this case, because trusses are typically engineered, anticipated point loads can be accommodated. This additional load must account for rack or bracket mounted solar collectors. For information on truss design, see Truss Plate Institute of Canada (TPIC) Bulletin #7 (March 12, 2012). While these are not compliance documents for the BC Solar Hot Water Ready Regulation, they provide guidance for the design of trusses in order to accommodate solar collectors. The design criteria used in TPIC s Bulletin #7 is a uniform dead load of 0.24 kpa and the additional point loads this creates when mounted to the roof. Bulletin #7 is primarily designed for the Natural Resources Canada Solar Ready program, which requires a larger roof space than does the BC Solar Hot Water Ready Regulation. However, the same truss design principles can be applied. If the area designated for future installation of the solar collector is a roof system that uses roof trusses, be sure to inform your roof truss supplier that you are building a home that must comply with the Solar Hot Water Ready Regulation. The truss supplier should be informed as early as possible in the construction process by the builder or homeowner so that any potential changes in truss design can be accommodated. IMPORTANT The design parameters in this regulation for structural members of roofs simply provide additional structural capacity for future installation of a solar domestic hot water system, and as such cannot account for all potential future factors. Owners are still responsible for an assessment before installing solar collectors in future, as loading implications will depend on installation methods, collector size and configuration, and so on. Office of Housing and Construction Standards Page 5

Conduit runs 5 (1) A minimum of 2 conduit runs must be provided that extend from the area directly adjacent to the building s primary service water heater to Section 5, Subsection (1) describes the requirement for the rough-in piping (conduit) that will later accommodate the solar hot water tubing. The conduit runs are typically installed in parallel and the choice of materials is the decision of the owner. In future, 2 tubing runs (typically copper pipe) are generally required to install a solar hot water system. Each required conduit run is provided to accommodate the installation of one ½ or ¾ tubing run plus insulation. The rough-in pipes should begin as near as possible to the home s primary hot water heater. The rough-in piping should terminate in one of the three areas described in (a) through (c). (a) an accessible attic space adjacent to the roof area designated for installation of solar collectors for a solar domestic hot water system, If the attic is accessible, the termination for the rough-in piping is best left in the attic, just above the level of the insulation, so it can easily be seen and identified at the installation stage. (b) the roof area designated for installation of solar collectors for a solar domestic hot water system, or Option (b) is to terminate the conduit above the roof surface itself. This option would be appropriate for an attic with limited access, such as a low slope, flat, cathedral or roof joist design. (c) the exterior wall surface directly adjacent to the area designated for installation of solar collectors for a solar domestic hot water system. Some installations will be designed for a wall area or perhaps a back yard installation, or installation on an accessory building. In these cases, the conduit should terminate at the outside wall nearest to the area designated for the solar hot water collector, as described in Option (c). Office of Housing and Construction Standards Page 6

(2) Conduit runs described in subsection (1) must (a) be accessible at both ends, (b) be capped or sealed at both ends to prevent water ingress and air leakage, (c) be identified by markings that are permanent, distinct and easily recognized, (d) have a minimum inside diameter of 50 mm, and (e) be able to accommodate the installation of insulated plumbing service for a solar domestic hot water system in compliance with CAN/CSA-F383, Installation Code for Solar Domestic Hot Water Systems, as referred to in the British Columbia Building Code. Section 5, Subsection (2) describes the requirements for the rough-in conduit itself. In cases where the conduit runs cannot be straight or continuous, it may be necessary to break the conduit into 2 or more sections, or to provide for bends in the conduit. In these cases, each section of conduit (conduit run) should be accessible at both ends in order to facilitate the future installation of the solar hot water tubing. More information on solar hot water rough-in, as well as best practice guides can be found at the following links: http://www.cansia.ca/government-regulatory-issues/provincial/solar-ready http://canmetenergy-canmetenergie.nrcanrncan.gc.ca/eng/renewables/solar_thermal.html\ These best practice guides are NOT compliance documents for the Province of BC Solar Hot Water Ready Regulation. Links are included for information only. Office of Housing and Construction Standards Page 7

Appendix Consolidated version of the two regulations: BC Regulation 101/2011 BC Regulation 163/2013 Contents 1 Definitions 2 Applications 3 Solar collectors for a solar domestic hot water system 4 Solar hot water ready components 5 Conduit runs Definitions 1 In this regulation, the terms in italics have the same meaning as in the 2012 British Columbia Building Code. Application 2 This regulation applies to the local government jurisdictions set out in the Schedule. Solar collectors for a solar domestic hot water system 3 (1) Subject to subsection (2), 2 conduit runs and an area that (a) is not less than 9.3 square meters, (b) has no dimensions less than 2.7 meters, and (c) is designated for future installation of solar collectors for a solar domestic hot water system in compliance with CAN/CSA-F383-87 must be incorporated in construction of new buildings of residential occupancy that contain (a) one dwelling unit, or (b) one dwelling unit and one secondary suite. (2) Subsection (1) does not apply with respect to new construction referred to in that subsection if the local government of the jurisdiction to which this regulation applies and within which the new construction is to occur is satisfied that building site conditions do not permit effective use of solar hot water heating. Structural requirements 4 (1) Except as permitted by subsection (2) of this section, structural members located in areas referred to in section 3 (1) must be designed to accommodate Office of Housing and Construction Standards Page 8

(a) (b) a uniform dead load of 0.24 kpa, in addition to design loads required by the British Columbia Building Code, and anticipated point loads where it is known that the solar collectors for a solar domestic hot water system will not be directly surfacemounted. (2) Roof trusses located in areas referred to in section 3 (1) must be designed to accommodate the anticipated load, including (a) a uniform dead load of 0.24 kpa, in addition to design loads required by the British Columbia Building Code, and (b) point loads resulting from the uniform dead load referred to in paragraph (a). Conduit runs 5 (1) A minimum of 2 conduit runs must be provided that extend from the area directly adjacent to the building s primary service water heater to (a) an accessible attic space adjacent to the roof area designated for installation of solar collectors for a solar domestic hot water system, (b) the roof area designated for installation of solar collectors for a solar domestic hot water system, or (c) the exterior wall surface directly adjacent to the area designated for installation of solar collectors for a solar domestic hot water system. Schedule (Section 2) (2) Conduit runs described in subsection (1) must (a) be accessible at both ends, (b) be capped or sealed at both ends to prevent water ingress and air leakage, (c) be identified by markings that are permanent, distinct and easily recognized, (d) have a minimum inside diameter of 50 mm, and (e) be able to accommodate the installation of insulated plumbing service for a solar domestic hot water system in compliance with CAN/CSA-F383, Installation Code for Solar Domestic Hot Water Systems, as referred to in the British Columbia Building Code. Office of Housing and Construction Standards Page 9

Local Government Jurisdictions Cariboo Regional District City of Abbotsford City of Campbell River City of Chilliwack City of Colwood City of Cranbrook City of Dawson Creek City of Duncan City of Fernie City of Fort St. John City of Kelowna City of Kimberley City of Langley City of New Westminster City of North Vancouver City of Penticton City of Pitt Meadows City of Port Coquitlam City of Port Moody City of Richmond Corporation of Delta Cowichan Valley Regional District District of Coldstream District of Elkford District of Hudson s Hope District of Invermere District of Maple Ridge District of Metchosin District of North Vancouver District of Peachland District of Sechelt District of Sparwood District of Tofino District of West Vancouver Greater Vancouver Regional District Municipality of North Cowichan Resort Municipality of Whistler Squamish-Lillooet Regional District Sunshine Coast Regional District Town of Qualicum Beach Town of Sidney Town of View Royal Township of Esquimalt Township of Langley Village of Ashcroft Village of Kaslo Village of Midway Village of Valemount Office of Housing and Construction Standards Page 10