WEAO STUDENT DESIGN COMPETITION 2019 PROJECT STATEMENT

Similar documents
2017 Annual Performance Report

Introduction. Background. Case Study: The Role of Optimization in Plant Re-rating Prepared by D.T. Chapman, CPO Inc.

Duffin Creek Water Pollution Control Plant Technical Information

Dealing with Unexpected Wastewater Treatment Plant Disruptions. February 16, 2017

Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP PNCWA 2010

Dundalk Wastewater Treatment Plant

RE: Annual Report 2016 Wardsville Wastewater Treatment Plant and Collection System

Role of Entrant s Firm. »» Final Design»» Completion of Funding. »» Engineering Services During Applications. »» Plant Startup and Filtration

MUNICIPALITY OF WEST ELGIN WEST LORNE WASTEWATER TREATMENT PLANT

MUNICIPALITY OF WEST ELGIN RODNEY WASTEWATER TREATMENT PLANT

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES

Performance Evaluation of the Moores Creek Advanced Water Resource Recovery Facility

February 16, Ministry of the Environment Southwestern Region 733 Exeter Road London, Ontario N6E 1L3. Attn.: Mr. Tom Clubb

Providing Infrastructure Redundancy at the Rocky River WWTP. Timothy McCann AECOM Keith Bovard Rocky River WWTP

Wastewater Treatment. Where does wastewater go when it leaves your house?

WASTEWATER DEPARTMENT. Bentonville Wastewater Treatment Plant Facts:

Feel free to contact me should you require any additional information regarding the report. I can be reached at

Case Study: City of Brantford. Controlling Industrial Discharges to Improve Plant Performance

Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation

Cannington Water Pollution Control Plant Annual Performance Report Annual Performance Report 2015

WEAO STUDENT DESIGN COMPETITION 2018 PROJECT STATEMENT

The Municipality of North Grenville

APPENDIX A. 1. Background. 1.1 Existing Facilities. Page 1

2017 Annual Performance Report

2017 Annual Performance Report

OPTIMIZATION STUDY OF THE ST. MARY'S WASTEWATER TREATMENT PLANT

Technical Memorandum No. 1

Assuming 100 gallons per capita per day, and 3 people per REU, design flows for the development are proposed to be:

2015 HDR, Inc., all rights reserved.

Operation and Control of Multiple BNR Processes in One WWTP

Copies: Mark Hildebrand (NCA) ARCADIS Project No.: April 10, Task A 3100

City of Elk River Wastewater Treatment Facility Improvements. Achieving Wastewater Treatment Goals

Watertown Wastewater Facility Plan. August 11, 2015

Dundalk Wastewater Treatment Plant

Current Treatment Approaches and Planning for the Future A Panel Discussion

Advanced Wastewater Treatment Plant Plant Profile

North Side WRP Master Plan Research and Development Department 2006 Seminar Series October 27, 2006 Metropolitan Water Reclamation District of

Stonecrest Estates Sewage Treatment Plant 2017 Annual Report

2017 ANNUAL WASTEWATER TREATMENT SYSTEM SUMMARY REPORT. Wastewater Treatment Plant:

VILLAGE OF ALGONQUIN 2014 WASTEWATER FACILITY PLAN UPDATE EXECUTIVE SUMMARY

A Battle to Be the Best: A Comparison of Two Powerful Sidestream Treatment Technologies: Post Aerobic Digestion and Anammox

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

Energy & Resource Recovery at Duffin Creek Water Pollution Control Plant

Energy Optimization for WWTPs Saving Green by Going Green

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

Yours very truly, Municipality of West Perth. Environmental Services

Watershed Overview of Wastewater Treatment Plant Performance

Sulaibiya world s largest membrane water reuse project

UDWQ POTW Nutrient Removal Cost Impact Study: Analysis of Tremonton City Wastewater Treatment Plant

<1ppm Phosphorus A BNR With No Chemical Addition Case Study

International Joint Commission Water & Wastewater Treatment Best Management Practices Forum Monday, March 26, 2012 Wayne State University, Detroit MI

2017 Performance Report for Bobcaygeon Waste Water Treatment Facility

Palmer Wastewater Treatment Plant Environmental Impacts. A summary of the impacts of this treatment alternative are listed below:

Energy Optimized Resource Recovery Project Presented By: Curtis Czarnecki, P.E.

Wastewater in Ontario: The ECO's perspective on onsite and decentralized wastewater management

RENNIA ENGINEERING DESIGN, PLLC CIVIL ENVIRONMENTAL STRUCTURAL. Report. Conceptual Wastewater Facility Plan. Olivet Center.

The following biological nutrient removal processes were evaluated in detail in the 2016 Liquid Processing Facilities Plan:

This document can be made available in other accessible formats as soon as practicable and upon request. Staff Report. Infrastructure & Public Works

Best Practice in Sewage and Effluent Treatment Technologies

WASTEWATER TREATMENT SYSTEM

Ditches for Energy Efficiency and Improved Nitrogen Removal

Alexandria Sewage Lagoon Treatment Facility Municipal Class C Environmental Assessment Public Information Centre #2 Welcome!

SECTION 8.0 NEWPCC SECOND PRIORITY CONTROL ALTERNATIVES

Anaerobic Digestion of High Strength Wastes within a TMDL

BIOLOGICAL WASTEWATER BASICS

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

Wastewater Treatment Works and Collections System Annual Report Year 2005 General Information

Pollution Control in the City of Windsor Wastewater & CSO Management 2013 Status & Update

Waste Water Treatment Plant Overview and Tour

Carbon Heat Energy Assessment and. (CHEApet) Tutorials: Carbon Footprint Primer

Wastewater Facility Plan City of Marshall, Minnesota

ENGINEERED WETLAND TECHNOLOGY TO ADVANCE STORMWATER QUALITY TREATMENT. Sheldon Smith March 28, Photo Optional

Palmer Wastewater Treatment Plant 6.7 Alternative 7: Upgrade Existing Lagoons with New Percolation Bed

Upgrading Lagoons to Remove Ammonia, Nitrogen, and Phosphorus *nutrient removal in cold-climate lagoon systems

Energy Neutral Opportunities

WWTP Side Stream Treatment of Nutrients Considerations for City of Raleigh s Bioenergy Recovery Project. Erika L. Bailey, PE, City of Raleigh

The Town of Petrolia Waste Management of Canada ENVIRONMENTAL STUDY REPORT EXECUTIVE SUMMARY

EGANVILLE SEWAGE SYSTEM 2013 PERFORMANCE REPORT

2014 Watershed Overview of Wastewater Treatment Plant Performance

WWETCO FlexFilter and Bio-FlexFilter

Capital Improvement Plan Update:

CEDAR CREEK Wastewater Treatment Facility

APPENDIX C. Public Consultation Centre (PCC) Displays. Appendix C1 PCC#1 Appendix C2 PCC#2 Appendix C3 PCC#3

UPGRADING GAZA WASTEWATER TREATMENT PLANT. Gaza City is populated with 550,000 inhabitants and it forms 45% of the Gaza strip population.

BRACEBRIDGE WASTEWATER TREATMENT

RESTRICTED URBAN REUSE OF KONYA (TURKEY) MUNICIPAL WASTEWATER TREATMENT PLANT EFFLUENTS VIA RECLAIMED WATER DISTRIBUTION SYSTEM

PLANNING FOR NUTRIENT REMOVAL: WHAT STEPS CAN WE BE TAKING NOW?

Iroquois Wastewater Treatment Plant 2016 Annual Performance Report

HOW TO SAVE COSTS AND IMPROVE SUSTAINABILITY WHILE REDUCING EFFLUENT NITROGEN

HISTORY

Nutrient Removal Optimization at the Fairview WWTP

An Innovative Approach to Retrofitting for Nitrogen Removal

Polishing Ponds. Biosolids Storage. Ammonia Removal. Digesters. Thickeners. Pretreatment. Final Clarifiers. Primary Clarifiers.

Presentation Outline

General Information on Nitrogen

2017 Annual Compliance Report. Operation & Maintenance of Paisley Wastewater System. March

EVALUATION OF ENERGY RECOVERY OPTIONS FOR CONVERSION OF AEROBIC DIGESTERS TO ANAEROBIC DIGESTION

Appendix D JWPCP Background and NDN

Wastewater Plant Tour. There Is Gold In Them There Plants

Bitterroot River Nutrient TMDL Technical Report WASTEWATER TREATMENT

Transcription:

Water Environment Association of Ontario Young Professionals Committee and Student Design Competition Sub-Committee and the Ontario Ministry of the Environment and Climate Change in Collaboration with Chatham-Kent PUC WEAO STUDENT DESIGN COMPETITION 2019 PROJECT STATEMENT OPTIMIZATION OF ENERGY AND NUTRIENT RECOVERY FROM WASTEWATER JUNE 2018

INTRODUCTION Optimization of Energy and Nutrient Recovery from Wastewater The topic of the 2018-19 WEAO Student Design Competition is resource recovery at the Chatham Water Pollution Control Plant (CWPCP). The CWPCP treats municipal wastewater from residential and commercial/industrial sources, and also hauled wastes. Currently, the treatment plant recovers energy by using biogas produced at the plant in a combined heat and power plant. The goal of the project is to maximize the revenue generated from recovering resources (energy, nutrients) present in the wastewater treated by the CWPCP. The design teams are asked to evaluate the current processes and identify initiatives that will improve financial returns from resource recovery. Phase I proposals will provide recommendations to improve financial returns using only the existing infrastructure (i.e. operational modifications and minor capital investments). Phase II proposals will provide recommendations on infrastructure improvements to improve financial returns above those achievable by implementing Phase I. BACKGROUND CHATHAM-KENT Chatham-Kent is a municipality in Southwestern Ontario that is mostly rural with population centres of Chatham, Wallaceburg, Tilbury, Blenheim, Ridgetown, Wheatley and Dresden. The municipality was created in 1998 by the merger of Kent County and 23 townships. The population was 101,647 in 2016. More information on the community can be found on municipality s web pages; a link to its strategic plan can be found in the supplemental information. The Chatham-Kent Public Utilities Commission (CK-PUC) operates water and wastewater systems in the municipality. It was created in 1998 by merging the 13 public utilities

commissions in the former Kent County. CK PUC is fully funded through water and sewer charges. BACKGROUND THE PLANT The Chatham Water Pollution Control Plant (CWPCP) is an activated sludge wastewater treatment plant located at 100 Irwin Street in the community of Chatham. CWPCP is the largest of the nine municipal wastewater treatment facilities operated by CK-PUC serving approximately 43,550 people, and has a rated capacity of 36,000 m³/day with a peak flow rate capacity of 72,000 m³/day. Figure 1: Aerial photo of Chatham Water Pollution Control Plant (2016) CWPCP treats municipal wastewater from residences and businesses/industries connected to the collection system, and also accepts hauled wastewater and landfill leachate. Industries that discharge to the collection system include a corn-based alcohol producer, food processing industries, greenhouse and a few automotive based industries. Influent characteristics are provided in Table 1, and Figure 2 shows plant flows in 2017.

Table 1: Influent Characteristics of municipal wastewater treated by the CWPCP PARAMETER 2017 2016 2015 Total Flow (1,000 m 3 ) 7,585.3 7,557.3 7,405.0 Avg Daily flow (1,000 m 3 ) 20.8 20.7 20.3 Peak day flow (1000 m 3 ) 62.1 67.8 63.0 TSS (mg/l) 260 169 232 BOD5 (mg/l) 187 172 210 TP (mg/l) 5.2 4.6 5.1 TKN (mg/l) 28.3 31.6 36.6 Figure 2: CWPCP plant flow from January December 2017 The CWPCP has two treatment trains, Plant 1 and Plant 2. Each treatment train includes primary clarifiers, aeration basins and secondary clarifiers. The aeration basins have anoxic zones at the head of each basin. The number of units and their sizes are listed in Table 2, and a process flow diagram of the plant is included in Appendix A. On-site lagoons provide temporary retention of primary-treated wastewater during high flows, which is subsequently reintroduced to the plant during lower-flow periods via the Main Lift Pumping Station. Excess phosphorus is removed using chemical precipitation with ferrous chloride added at the head of the primary clarifiers.

Table 2: Number and sizes of liquid treatment processes at CWPCP Process Plant 1 Plant 2 Primary Clarifiers Surface Area (m 2 ) 476 (two cells) 600 (two cells) Aeration Basins Volume (m 3 ) 6,340 (two cells each cell with three passes) 13,000 (two cells each cell with three passes) Secondary Clarifiers Surface Area (m 2 ) 714 1,400 Final effluent is discharged to the Thames River, which flows into Lake St. Clair and is part of the Western Lake Erie basin. Effluent discharge criteria for CWPCP are listed in Table 3 as stated in Environmental Compliance Approval (ECA) number 6551-8WXKHC (refer to the ECA for more information on effluent requirements). Effluent Parameter Table 3: ECA Effluent requirements of the CWPCP Effluent limit monthly average concentration (mg/l except for E.Coli) Effluent objective monthly average concentration (mg/l) cbod5 15 10 TSS 15 10 TAN freezing period 4 3 TAN non-freezing period 3 2 TP 0.75 0.6 Total Residual Chlorine 0.01 Non-detectable E.Coli 200 counts per 100 ml (monthly geometic mean density) 150 counts per 100 ml Sludge management at the CWPCP utilizes three 2,340 m 3 anaerobic digesters, each equipped with mixing equipment and piping for sludge and digester gas. Two digesters are operated as primary digesters and the third as a secondary digester. Sludge settled in primary clarifiers is transferred to primary digesters for stabilization. Primary clarifier sludge includes Waste Activated Sludge (WAS) from secondary clarifiers as WAS is co-thickened in the primary clarifiers. The biogas produced in the digesters is used as fuel for a combined heat and power plant, and excess biogas is flared. Digested sludge is dewatered in two 2.5 meter wide belt filter sludge presses that include a polymer mixing and dosing system. Dewatered sludge is transferred to sludge drying beds before final disposal where it is hauled to Ridge Landfill as top dressing.

Historical, Recent and Pending Plant Upgrades Upgrade 1963: Plant One One primary clarifier with two cells having a total surface area of 476m² A diversion gate associated with primary clarifier # 1 to lagoon pumping station One aeration tank with two cells and three passes in each cell having a total aeration volume of 6340m³ Aeration Blower room with four blowers One secondary clarifier with two cells having a total surface area of 714m² Two anaerobic digesters with a capacity of 2340m³ Return activated sludge pumping building Chlorination and contact chamber Upgrade1991-1997: Headworks/Digester A head works building, receiving flows from onsite pump station and pump station number 3 Two mechanical screens with screening conveyor Two grit tanks with an effective volume of 366m³, including grit removal system Leachate holding tank with a volume of 180m³ Flow splitting channel Sulfur dioxide building One anaerobic digester with capacity of 2340m³ External contact chamber for disinfection and dechlorination Upgrade 2004: Plant Two One primary clarifier with two cells having a total surface area of 600m 2 A diversion gate associated with primary clarifier # 2 to lagoon pump station One aeration tank with two cells and three passes having a total volume of 13,000m³ Four 8000m³/hr capacity blowers to supply process air One secondary clarifier with two cells having a total surface area of 1400m² Upgrade 2013: Sludge Receiving and Transfer Station One 74m³ storage capacity buried fiberglass sludge receiving tank Co-Generation in partnership with Entegrus Power

Co-Generation System: Size: 27,500 ft 3 Capacity: 177 cfm Capabilities of the Co-Gen system: 250 KW Quality required: Composition Max: 0.5% H2S, CO2, CH4, O2 Output in electricity: 250 KW Upgrade 2015: Turbo Blower Replacement of blower. Upgrades resulted in an estimated annual reduction of 1,356,835 kwh. Project cost of $235,000 results in a cost avoidance of $135,683.50. Upgrade 2018: Headworks and Electrical Upgrades Headworks Ventilation and Electrical Upgrades Project valued at $500,000. Electrical Upgrades Project valued at $1.1 million Headworks fine screening upgrade expected total cost of $400,000.00 BACKGROUND - OPTIMIZATION Optimization is a philosophy of continuous improvement to make the best use of existing resources people, infrastructure and funding. Successful optimization requires making databased decisions and balancing multiple objectives, requirements and/or needs. An example of successful optimization is the achievement of total ammonia removal and low total phosphorus discharges at the Brantford Wastewater Treatment using existing treatment infrastructure. Optimization to achieve nitrification removed a $27.75 million expansion and upgrade from the city s budget, and demonstration of phosphorus removal capabilities is deferring a $15 million expenditure on effluent filters. Case studies providing more information on Brantford s optimization activities, and also a case study on blower optimization at the Simcoe Wastewater Treatment Plant can be found in the supplemental information. Selecting and controlling operational parameters is a key element of an optimization program. A worksheet of some typical operational parameters for activated sludge treatment plants is provided in the supplemental information as a reference.

BACKGROUND RESOURCE RECOVERY Globally, municipal wastewater treatment plants are broadening their objectives from removing contaminants to recovering resources as a value add product. Resources that can be recovered from municipal wastewater include: Energy such as biogas, heat, or kinetic energy; Nutrients such as phosphorus and nitrogen; Reusable water; and Other valuable constituents in municipal wastewater. Some wastewater treatment plants are focusing on energy recovery and production to become selfreliant on energy produced at the treatment plant ( net zero ) or net exporters of energy. A number of treatment plants are pursing this approach, and information on an Ontario approach to wastewater energy recovery and production can be found in the supplemental information. Nutrient recovery and reuse is another area of resource recovery gaining interest in the municipal wastewater industry. Technologies now exist to extract nutrients from wastewater to produce commercial fertilizers. One example of nutrient recovery are technologies that create struvite from wastewater process streams, which can be marketed as a slow-release fertilizer. BACKGROUND - CHALLENGES CK-PUC is already pursuing resource recovery through energy recovery via the CHP system. However, there may be opportunities to improve energy recovery and implement nutrient recovery. It is the utility s desire to maximize the benefits of the existing CHP system through revenue generation from electricity production, and offsetting heating requirements at the treatment plant. Opportunities to maximize benefits may be through process control optimization of the liquid or solid (sludge) treatment trains and/or addition of organic wastes (e.g. fats, oils and greases and organic waste from off-site sources) to increase biogas production. A summary of biogas production is provided in Table 4. Note that the CHP was not operational in 2017 and so not data is available for that period. Table 4: Historical Biogas Production Year Digester Gas to Digester Gas Natural gas CHP (m 3 ) Flared (m 3 ) Used (m 3 ) 2015 488,449 230,272 488 2016 402,879 140,674 195,577 2017 0 406,768 33,843 The CWPCP is located in the Western basin of Lake Erie. Recently, the governments of Canada and Ontario released the Canada-Ontario Lake Erie Action Plan that states on page 45: Ontario will work with municipal partners to establish by 2020 a legal effluent discharge limit (in Environmental Compliance Approvals) of 0.5 milligrams per litre of

total phosphorus for all municipal wastewater treatment plants (WWTPs) in the Lake Erie basin that have an average daily flow capacity of 3.78 million litres or more Currently, the discharge limit for total phosphorus at the CWPCP is 0.75 mg/l, which means CK-PUC must work toward maintaining a lower total phosphorus discharge than what is currently required. The treatment plant removes excess phosphorus using chemical precipitation by ferrous chloride, which is a significant operational cost and may make the phosphorus unavailable for re-use. Table 5 provides a summary of influent and effluent total phosphorus, and the amount of ferrous chloride added. Table 5: Influent and effluent Total Phosphorus (TP) and chemical added 2017 2016 2015 Influent TP (mg/l) 5.2 4.6 5.1 Effluent TP (mg/l) 0.3 0.42 0.28 Ferrous Chloride Added (L/d) 72 66 55 Another consideration at the CWPCP is operations staff must manage variable loading to the plant due to rainfall events, and periodic high loadings from local industries, and hauled wastewater. A summary of plant flows and loading is provided in Table 1. CWPCP also accepts hauled septage and received 2,941 m 3 in 2017. There is currently no additional quality data available on septage, as it is not sampled and analysed either in house, or by a third party lab. This is, however, being put into place later in 2018. Variable loadings at a wastewater treatment plant pose a challenge because high flows can lead to a loss of solids from the plant and periodic or seasonal loadings from industry can upset treatment processes. Balancing the desired outcomes of maximizing the benefits of the CHP system and reducing phosphorus discharges with the variability in process loadings poses day to day challenges for treatment plant operations. CK-PUC believes opportunities exist to optimize the system as a whole (liquid and solids treatment trains) to meet their desired outcomes while achieving good economical effluent that protects the environment and supports the local economy. PROJECT GOAL AND SPECIFIC OBJECTIVES The goal of the project is to maximize revenue generated from recovering resources (energy, nutrients) present in the wastewater treated by the CWPCP using existing infrastructure, and using infrastructure upgrades. The specific objectives of the project are: Phase 1: Evaluate current digester performance, biogas production and CHP performance.

Create a conceptual plan and/or design for operational modifications and minor infrastructure improvements to improve digester gas production and CHP performance using existing liquid and solid treatment train infrastructure. Phase 2: Create a preliminary design to recover additional energy resources above that achieved by Phase 1. Produce a conceptual design for one additional area in which the CHWTP may benefit from nutrient recovery opportunities while not decreasing the current level of TP performance. DESIGN CRITERIA Designs must meet the following design criteria: Water Quality Adherence to the Environmental Compliance Approval effluent limits and no decrease in performance in terms of effluent water quality, including pollutant loadings, based on the last three years. Climate Change Overall reduction of greenhouse gas emissions from the CWPCP to work toward adherence to Ontario s Five Year Climate Change Action Plan (Action Area: Government, 1.2) which outlines the new government greenhouse gas pollution reduction target as 50 per cent below 2006 levels by 2030. Cost-effectiveness Maximize electricity and revenue generated through the CHP system Target payback of 5 years on any investments; however, payback periods up to 10 years will be considered provided there are additional benefits (e.g. ease of operation, improved performance) that warrant a higher payback period Proposed designs must take into consideration the rated capacity of the WPCP, limitations of the footprint of the existing plant and the importation of sludge from other facilities. At no time should the improvement of one element lead to the deterioration of performance in any other element. SCOPE OF WORK Design team proposals need to address the following elements: Phase I Characterization of current digester performance, biogas production and CHP performance, and a proposal to optimize the existing infrastructure through operational modifications and minor capital investments to achieve the goal of the project. The proposal can address the solid and/or

the liquid treatment trains. The proposed method(s) must not include addition of major infrastructure (e.g. building an additional digester or increasing the size of an aeration basin), but could include new mechanical equipment (e.g. mixer, pump), replacement or improvement of existing mechanical equipment, and additional monitoring equipment. The proposal must not include importing organic wastes other than those already received (importing organic wastes can be addressed in Phase II). The proposal should include a review and comparison of various methods, a conceptual design of any added/modified equipment, suggested studies to gather additional information, and the engineering feasibility of implementing proposed actions. Phase II The design team will propose enhancements to the solids and/or liquid train to recover additional energy resources or achieve energy efficiencies from the wastewater treatment processes above that achieved by Phase 1. The enhancements can include construction of new processes, modifications of existing ones, or importing additional wastes to the treatment plant. The preferred alternative should benefit operations, lessen the environmental impact and/or reduce the cost of treatment. A preliminary design must be provided including comparisons of technologies, energy demands and preliminary economics. The design team will also propose one other area where a nutrient recovery opportunity exists that could also lessen the environmental impact and/or reduce the cost of treatment. A conceptual design must be provided including comparisons of technology, energy demands, preliminary economics and effluent characteristics. DESIGN REPORT REQUIREMENTS Specifically, the Design Team must provide the following: Background Characterization of current anaerobic digestion performance (e.g. volatile solids destruction), biogas production, and CHP performance relative to expected performance Characterization and quantification of the nutrient value of industrial loading, residential wastewater, sludge receiving, leachate and septage. Include a rationale for any estimates when plant data is not available. Characterization of current greenhouse gas emissions from the entire plant (combination of liquid and solid treatment trains). Include a rationale for any estimates when plant data is not available. Phase I Comparison of current plant process parameters (see process parameters worksheet in supplemental information) to those of a typical activated sludge treatment plant An optimization plan that identifies potential process control modifications, limitations of the proposed modifications and how to overcome them. The optimization plan could also include a conceptual design for minor capital improvements that could enhance

performance of the existing liquid and solid treatment system to meet the goal of the project. A comparison of alternative approaches to optimization. Identification of any monitoring and data gaps/needs, and propose studies to collect additional data or information. An economic cost-benefit analysis for the preferred and alternative approaches that includes operating and maintenance cost estimates, as well as pay-back periods. Selection of the preferred process using a decision matrix. Computation of the expected energy recovery yield, revenue generation, and greenhouse gas emissions of the preferred approach. Identification of limitations of the preferred approach and how they may be minimized. Phase II Comparative discussion of alternative resource recovery processes and techniques that are relevant to the CWPCP. An economic cost-benefit analysis for the preferred and alternative methods including preliminary capital, operating and maintenance cost estimates, as well as pay-back periods. Selection of the preferred process (decision matrix) Expected energy recovery yield, revenue generation, and greenhouse gas emissions of the preferred process. Required strategies, policies and agreements for the Township on accepting external wastes for digestion improvement (if chosen as a preferred alternative) Identify limitations of the preferred approaches and how they may be minimized. Preliminary design of the preferred alternative. Designs will include preliminary sizing of major equipment or installations, including an outline of process control systems. Implementation schedule and the need for pilot work to verify the preferred alternative for scaled up application at the treatment plant. Appendices must include: Calculations indicating the expected resource recovery, revenue generation, greenhouse gas emissions and any effects on the treatment process (either to the liquid or solid streams) of the proposed design. Include all calculation spreadsheets; Manufacturer data sheets and catalogues of all major and minor equipment; and Design drawings (see below for details). Design drawings must be provided that clearly show the layout of the proposed CWPCP retrofit(s). As a minimum, the following drawings must be included: 1. A drawing identifying Phase I sites and conceptual layouts for minor equipment 2. A schematic identifying monitoring modifications and locations, if applicable. 3. Site plan for the Phase II retrofit including value added component; 4. Process schematic for Phase II retrofit;

The drawings must be printed on 11 x 17 landscape sheets, folded and included as an appendix in the design report. A digital copy of the drawing will also be required in PDF format. SUPPLEMENTAL INFORMATION The following documents are provided to aid in the preparation of the design report: Canada-Ontario Lake Erie Action Plan o (https://www.ontario.ca/page/canada-ontario-lake-erie-action-plan) Chatham-Kent Plan 2035 o (https://www.chatham-kent.ca/local-government/ck-plan-2035) CWPCP ECA #6551-8WXKHC CWPCP Performance Report, 2017 Excel Spreadsheet of CWPCP Performance 2015-2017 Getting to Net Zero Energy Leadership Forum hosted by SOWC and OCWA o (https://sowc.ca/getting-to-net-zero-energy-leadership-forum-hosted-by-sowcand-ocwa/) MOECC Design Guideline for Sewage Works Optimization Case Studies: o City of Brantford Nitrification https://drive.google.com/file/d/0bwwup5q6kec2oeutzu83nu9irvk/view Phosphorus Removal https://drive.google.com/file/d/1w9ulumj4ysafm9npzl4klspyvhbzhfry/vie w o Simcoe Wastewater Treatment Plant Blowers https://drive.google.com/file/d/1fyi2cgu7mmzrz3mgt7bac9cxv5ay4fct/vi ew Optimization Guideline Manual for Sewage Works 2010, WEAO Optimization Process Parameters Worksheet The Ontario Composite Correction Program Manual for Optimization of Sewage Treatment Plants Wastewater Treatment Plant Optimization (by National Research Council of Canada)

Appendix A Plant Process Flow Diagram