Purification of Stormwater Using Sand Filter

Similar documents
Drawer Compacted Sand Filter: A new and innovative design for on-site wastewater treatment

Wetlands Application. Constructed Wetlands

High-Rate Stormwater Treatment with Up-Flow Filtration

High-Rate Stormwater Treatment with Up-Flow Filtration

Constructed Wetlands

Case Study: Parkson DynaSand D2 Filtration and Compliance Jessy Matthew John, The Probst Group

Seventh International Water Technology Conference IWTC7 Egypt 1-3 April 2003 SECONDARY TREATMENT OF SULLAGE WASTEWATER

Wet Detention Ponds, MCTTs, and other Options for Critical Area Stormwater Control. Robert Pitt University of Alabama, Tuscaloosa, AL

4. Ponds and infiltration BMPs can achieve 60 to 100% removal efficiencies for sediment.

Drinking Water Production Using Moving Bed Filtration

The soil is a very. The soil can. The manure. Soil Characteristics. effective manure treatment system if manures are applied at the proper rate.

ORDINANCE # 854. Stormwater Management / Operation and Maintenance Requirements

CE 370. Filtration. Overview of the Process Location in the Treatment Plant

WASTEWATER TREATMENT SYSTEM

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

Quality of Rainwater From Rainwater Harvesting Systems in Sanaa. Nagib Ghaleb N. Mohammed, Civil Engineering Department, University of Bahrain

UPGRADING GAZA WASTEWATER TREATMENT PLANT. Gaza City is populated with 550,000 inhabitants and it forms 45% of the Gaza strip population.

Filter media for stormwater treatment and recycling: the influence of hydraulic properties of flow on pollutant removal

Webinar Overview. Presenter: Moderator: Length of Webinar: (1) hour Questions: For More Information or Comments: Amanda Ludlow Principal Scientist

WASTEWATER TREATMENT THAT CONTAMINATED WITH LEAD

EFFECTIVE AND EASILY MAINTAINED TREATMENT SOLUTIONS

WAT-E Physical and Chemical Treatment of Water and Waste Filtration. Adjunct Prof. Riina Liikanen

Water Treatment. Water Treatment. Water Treatment. Water Treatment. CIVL 1101 Introduction to Filtration 1/15

INFLUENCE OF EFFECTIVE SIZE AND LEVEL OF SUPERNATANT LAYER IN SLOW SAND FILTER PERFORMANCE

EVALUATING THE DEPOSITION OF POLLUTANTS IN THE PORES OF GRANULAR MEDIA DEEP-BED FILTERS

Science Exploration. DHRITI BHATTACHARJEE Class : VII/C Roll No : 31

TABLE B.3 - STORMWATER BMP POLLUTANT REMOVAL EFFICIENCIES

BIOSAND WATER FILTER. What s Inside: Household Water Treatment. Filter Details. Materials for Construction. Filter Construction.

CGN 6933: Drinking Water Treatment Processes Department of Civil & Environmental Engineering University of South Florida Cunningham Spring 2013

Best Practice in Sewage and Effluent Treatment Technologies

Construction of Rapid Sand Filters i) Media

ENVIRONMENTAL ENGINEERING-I

13. High Rate Filtration Process

ARTIFICIAL INFILTRATION OF GROUNDWATER

Shelbyville, Kentucky Stormwater Best Management Practices (BMPs) Stormwater Pollution Treatment Practices (Structural) DRAFT

COMPARISON OF STORMWATER QUALITY TREATMENT GUIDELINES AND CRITICAL STRUCTURAL BEST MANAGEMENT PERFORMANCE FACTORS AND PARAMETERS TO CONSIDER

DRAFT PTP-06. Activity: Water Quality Units

Evaluation of gradual hydroponic system for decentralized. wastewater treatment and reuse in rural areas of Palestine.

DRIP EMITTER SYSTEM STUDY GUIDE

Sanitary and Environmental Engineering I (4 th Year Civil)

DEEP BED COLUMN DESIGN USING BURNT OIL PALM SHELL IN URBAN STORMWATER FILTRATION. Universiti Malaysia Sabah, Kota Kinabalu, Sabah.

BASICS OF WASTEWATER TREATMENT

WinSLAMM v Program Modifications Final, 3/16/19

Module 19 : Aerobic Secondary Treatment Of Wastewater. Lecture 24 : Aerobic Secondary Treatment Of Wastewater

Removal of Heavy Metal from Landfill Leachate Using Vertical Flow Construction Wetland

WinSLAMM v Program Modifications Final, 12/12/17

WQ-06 SAND FILTER. 1.0 Sand Filter. Greenville County Technical Specification for: 1.1 Description

Transitioning from the Percolation Test to Soils Evaluation Colorado Environmental Health Association Annual Education Conference 2015

Waste Water treatment

Water Pollution. Objective: Name, describe, and cite examples of the eight major types of water pollution.

Impact of Compaction State and Initial Moisture on Infiltration Characteristic of Soil

WATER SUPPLY SERVICES

ecostorm plus 400 Stormwater Filtration System For the removal of sediments, heavy metals and nutrients.

You may choose to use a filter as part of your water treatment system. Focus your work at this station on these three questions:

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C.

INTRODUCTION BMP DATABASE PROJECTS IN PA

Observed infiltration and clogging characteristics for tested media.

POTABLE WATER SUPPLY DEFINITIONS

Removal of Algae and Cyanobacterial Toxins during Slow Sand and Bank Filtration

POLLUTANT REMOVAL EFFICIENCIES FOR TYPICAL STORMWATER MANAGEMENT SYSTEMS IN FLORIDA

Module 23 : Tertiary Wastewater Treatment Lecture 39 : Tertiary Wastewater Treatment (Contd.)

ENVIRONMENTAL ENGINEERING

CEE 371 Water and Wastewater Systems

Figure Trickling Filter

Domestic Waste Water (Sewage): Collection, Treatment & Disposal

CHAPTER 7: guidance. categories: Pollutant Removal. Jordan Lake watershed) Cisterns. Bioretention Areas. Green Roofs. Dry. Proprietary Devices

(Print), ISSN (Online) Volume 4, Issue 6, November December (2013), IAEME TECHNOLOGY (IJCIET)

1.85 WATER AND WASTEWATER TREATMENT ENGINEERING TAKE-HOME MID-TERM EXAM DUE FRIDAY NOVEMBER 4, 2005 AT 1:00 PM

Vortex Separator. May be more cost-effective pre-treatment devices than traditional wet or dry basins.

International Journal of Science, Environment and Technology, Vol. 4, No 5, 2015,

WASTEWATER TREATMENT (1)

Total Suspended Solids: The Hows & Whys of Controlling Runoff Pollution

Particulate Transport in Grass Swales

Fuzzy Filter: The Right Path for Graton Community Services District

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water

Field Evaluation of a Stormceptor Model STC 1200 Westwood, Massachusetts. Prepared by: Stormceptor Group of Companies

Rawal Lake Water Treatment Plant Rawalpindi, Pakistan

Permeable Pavement for Stormwater Management Porous Pavement

Streamlines V2, n2 (May 1997) A Newsletter for North Carolina Water Supply Watershed Administrators

Water Pollution. Chapter 20

Chapter 6 Sand Filtration Treatment Facilities

A Hybrid Constructed Wetland System for Decentralized Wastewater Treatment

3rd International Conference on Engineering & Gaza Reconstruction DESIGN AND MANUFACTURING OF A SOLAR WATER DISTILLATION UNIT

Improvement of Drinking Water Plant Treatment

The Membrane Wastewater Treatment Plant in Ihn Layman s report

STORMFILTER THE MOST PROVEN. stormwater filtration system

THE USE OF STORMDMT TECHNOLOGY AS A LOW COST SOLUTION TO REMOVE METALS FROM STORMWATER RUNOFF

George Hild Hild & Associates, Inc. River Falls, WI

Compact Waste Water Treatment MBR /MBBR Technology

INNOVATIVE TECHNOLOGY TO IMPLEMENT A REUSE WATER PROGRAM. Stefan Haecker*, John Healy** 9311 College Parkway, Suite 1 Fort Myers Florida 33919

Removing Dissolved Pollutants from Stormwater Runoff. Andy Erickson, Research Fellow St. Anthony Falls Laboratory March 8, 2012

Greener Homes National Summit Rainwater Harvesting & Rain Garden Design and Performance Sustainable Water Management Session September

Sorbtive Vault Operations & Maintenance Manual

HYDRO-CLEAR FILTERS: COUNT ON THEM 24/7/365 REACTION TANKS

Treatability Study for Castor Oil Unit

Conditional Interim Certification Findings

The Islamic University of Gaza- Civil Engineering Department Sanitary Engineering- ECIV 4325 L5. Storm water Management

19. AEROBIC SECONDARY TREATMENT OF WASTEWATER

Water Our most precious resource

TREATMENT OF WATER. A.Sateesh Chemist State Level Laboratory

Transcription:

Journal of Water Resource and Protection, 2013, 5, 1007-1012 Published Online November 2013 (http://www.scirp.org/journal/jwarp) http://dx.doi.org/10.4236/jwarp.2013.511105 Purification of Stormwater Using Sand Filter Abdel Majid Nassar 1, Kamel Hajjaj 2* 1 Environment Engineering Department, Islamic University Gaza, The Gaza Strip, Gaza, The Palestinian Territories 2 Site Engineer, Infrastructure & Camp Improvement Program-UNRWA, The Gaza Strip, Gaza, The Palestinian Territories Email: anassar@iugaza.edu.ps, * k.hajjaj@unrwa.org Received July 2, 2013; revised August 5, 2013; accepted September 2, 2013 Copyright 2013 Abdel Majid Nassar, Kamel Hajjaj. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. ABSTRACT Rain water is an important source to feed the groundwater aquifer, whether directly or by harvesting and recharging. The importance of purification is for reducing the risk of pollutants from recharging runoff rainwater. The use of sand filter as a technique considered not expensive and commonly used for removing contaminants from water and wastewater treatment industries. The methodology used laboratory testing, by designing and constructing pilot plant to experiment the sand filter for purification, and made simulation for the infiltration of storm water through sand filter of 2 meters depth, in order to find the relationship between the depth on one hand, and the of suspended solids and fecal bacteria on the other hand, to know the effective depth that gets the purification. The research results during three days of infiltration show that the sand filter can remove fecal bacteria at a depth of 150 cm, and provide purified water with a concentration of suspended solids less than 20 mg/liter at a depth of 75 cm. Keywords: Sand Filter; Suspended Solid; Coliforms; Stormwater Purification 1. Introduction The population and urbanization incensement led to increasing the quantity of runoff while decreasing in the natural infiltration, storm water runoff including sediment, nutrients, toxic substances, oxygen-demanding materials and bacteria, all of which were the direct infiltration of urban runoff that led to contamination of groundwater [1,2]. The benefits of storm water infiltration including the usual benefits of storm water management, the prevention of flooding and erosion, coupled with the benefit of groundwater recharge, commonly sand filtration is used as a technique for removing contaminants from water and wastewater treatment industries during the last decade [3]. AWWA [4], Torrens et al. [5], and Anderson et al. [6] stated that the successful choice of a filter media as sand filter to produce satisfactory desired pollutant performance depended upon the proper choice of the depth of the filters, type of sand, sand size and distribution, conditions of influent water, quality of effluent, the filtration rate, and dosing regime and resting period duration, all of which affected the hydraulic performance and * Corresponding author. purification efficiency of the filters. Torrens et al. [5] stated that the sand used as the filter medium must be fine enough to ensure the biological analyses, and coarse enough to avoid surface clogging and maintain correct aeration. Granular media that is too coarse limited the retention time to a point where adequate biological decomposition is not attained. Too fine media limits the quantity of water that may be successfully filtered due to early filter clogging [6]. Coarser sands have larger pore spaces that have high flow-through rates but pass larger suspended particles. A very fine sand has small pore spaces with slow flow-through rates and filter out smaller total suspended solids (TSS) particles [7]. There are two types of filtration in storm water treatment: rapid and slow. In the slow filtration, the media used is considered as a fine sand, and the designed rate lies between 0.1 and 0.4 m 3 /h per square meter of surface, and the media used has size of 0.2 to 0.5 mm, according to the fact that its specifications have very low hydraulic rates, because they do not have backwash systems. The rapid filtration used media considerably coarser with an effective grain size of 0.6-2.0 mm. The interstices between the grains are larger, providing less resistance to the downward flow, and thus permitting higher velocities,

1008 A. M. NASSAR, K. HAJJAJ usually in the range 5-15 m 3 /m 2 /h [8]. Anderson et al. [6] summarized the mechanism process that occurs to some degree within the filter as physical, chemical, and biological treatment processes. Straining, sedimentation, inertial impaction, interception, adhesion, flocculation, diffusion, adsorption and biological activity have been suggested as mechanisms of contaminant in filtration. Actually, the mechanisms of of pollutants vary depending on the type of filter. A physical-chemical process has occurred in rapid filter for separating suspended and colloidal impurities from water by passage through a bed of granular material, water fills the pores of the filter medium, and the impurities are adsorbed on the surface or trapped in the openings [9]. On the other side a layer of inert deposits and biological matter forms on the surface of the sand bed. This layer is referred to as the Schrnutzdecke, this layer both with biological growth within the filter bed considered as the important process of purification mechanism of slow sand filters [8-10]. Bruijn and Clark [11] concluded that there are correlations between TSS and particulate runoff concentrations of chromium, copper, and zinc, indicating that solids may reduce total metals concentrations, therefore specific storm water treatment goals usually specify about 80% reductions in suspended solids concentrations. From the past experience, it is learned that biological activity decreases with reducing the filter s depth. In other words, the biological activity is enhanced with increasing sand depths. Therefore, the viruses and other suspended and organic matter have to travel more through the sand bed and the possibility of of these impurities is significantly increasing. Therefore, higher efficiency is expected at higher sand depths [12]. 2. Material and Method 2.1. Material The sand filter used in the research study was a yellowish fine to medium clean non-plastic dune sand of high permeability, Figure 1 illustrates the sieve analysis for the sand filter, It is clear that the type is slow sand filter, as the particles ranges from 0.15 to 0.60 mm also confirm to grain size of sand in specifications (BS 1200). According to study done by Hamdan et al. [13], that test the quality of Gaza storm water run off which is the same sample properties of collected storm water that used in research, shown that it is consider good enough for artificial recharge in terms of salinity (Cl ) and nitrate ( NO 3 ), as concentrations of both were very low. Concentrations of Total Organic Carbon (TOC) were found in urban road runoff, which can be explained by minor mixing with wastewater when this floods from manholes onto road. The results of heavy metal analyses such as cadmium and lead, were found to be close to the international, regional and local standards for artificial recharge purposes. 2.2. Methodology The aim of this paper is to investigate and to reach the optimum efficiency of using sand filter for purification of storm water, by testing in laboratory the quality of effluent of filtrated storm water samples at different depths of the sand filter media and by investigating the efficiency of purification. A plant that used in this study was locally manufactured, Figure 2 shows a schematic diagram of the system. It isconsists of the following; 2.3 meters cylindrical PVC-U pipe with 8 inch diameter, storm water tank, motion fan to avoid the settling of sediments, overflow tank to collect the exceeded water, glass window with 5 cm width and 50 cm height to monitor the media, and 3/4 PE pipes for connection and carrying water through the system. % Passing 100 90 80 70 60 50 40 30 20 10 0 0.01 0.1 1 10 Sieve opening (mm) Figure 1. Grain size distribution of filter materials. Figure 2. Schematic diagram of the system.

A. M. NASSAR, K. HAJJAJ 1009 The 8-inch cylindrical PVC-U pipe is filled with depth 200 cm of sand media. The pipe contains a number of valves at varying distances from the upper surface of the media; at 12.5 cm, 25 cm, 37.5 cm, 50 cm, 75 cm, 100 cm, 150 cm, and 200 cm respectively. The experiment was continuously conducted with certain properties of sand media for a period of three days, the average effluent velocity 0.32 m/hr. The selected parameters which are used concentration of suspended solid and fecal to illustrate the relationship between depth and the efficiency. 2.3. System Operation After testing the sand filter media, the apparatus were assembled. After that the system was operated firstly using clean water to wash the sand filter media and remove any impurities that may exist on it; this step continued till reaching a steady state flow in order to be cleaned water. The collector tank of 500 liters was filled with storm water and all the valves were closed excepting the drainage valve. The controlling of the influent storm water flow was done through the tank valve as well. The infiltration test was continuously conducted for three days, the suspended solid and fecal, at each different depth specified above were measured and calculated. The results had been presented and the relationships had been made between percent and depth of filter, so that they can be easily discussed and analyzed. 2.4. Sample Collection Samples were collected using sterilized 500 ml plastic bottles from both the influent and the effluent outlets of the filters. The collected samples for microbiological analysis were placed in an ice box with ice packs to maintain the temperature of 4 C. Strict sterilized conditions were maintained throughout the collection and transportation of these samples. Each valve was opened at least one minute prior collect the samples to flushing any pollutant that may exist around each valve Thus, accurate results can be obtained. The sterilize bottles were numbered and labeled. Attention was also paid during sampling to avoid mixing effluents that may lead to change the percentage of fecal. For well and proper sampling, it was necessary to sterilize the sample bottles through submerging them in boiling water for 5 minutes. Representative samples were made by taking three samples for each effluent depth valve and then mixing them to get a composite sample. The samples bottles were immediately brought to the lab for analysis in term of fecal and suspended solid concentration. 3. Results and Discussion 3.1. Coliforms Removal Results of three days infiltration concluded in Table 1. Figure 3 illustrated the percent of fecal through 2 m of filter media versus the depths. It is clearly shown form the figures that the fecal coliform is completely removed by infiltration through sand filter after a depth of 150 cm in these three days, and also at depth 75 cm there is at least 77.8 and the percent decreases day by day even at the third % Percent Removal of fecal coliform %110 %100 Cumulative Depth (cm) %90 %80 %70 %60 %50 %40 %30 %20 %10 %0 st Day1 nd Day2 rd Day3 0 25 50 75 100 125 150 175 200 Sand Filter Depth (cm) Figure 3. Percent of fecal. Table 1. Removal of fecal during three days. 1st Day 2nd Day 3rd Day Influent fecal = 9000 col./100 ml (col/ 100 ml) (col. 100 m Influent fecal = 6000 col./100 ml Influent fecal = 5000 col./100 ml (col./ 100 m 12.5 8000 11.1% 5000 16.7% 6000 0.00% 25 7000 22.2% 5000 16.7% 6000 0.00% 37.5 6000 33.3% 4000 33.3% 5000 0.0% 50 5000 44.4% 3000 50.0% 2000 60.0% 75 2000 77.8% 1000 83.3% 1000 80.0% 100 2000 77.8% 1000 83.3% 1000 80.0% 150 0 100.0% 0 100.0% 0 100.0% 200 0 100.0% 0 100.0% 0 100.0%

1010 A. M. NASSAR, K. HAJJAJ day. It is found that there are some contaminations in the upper layer of the sand media due to infiltration process which consequently affects the treatment performance. The percent increased with increased the filter depth, during continuous three days infiltration generally, they have a close pattern and there is no significant difference in the percentage of between them with exception to the upper depths on the third day, due to accumulation of pollutants at this area. As shown in Figure 3 at depth between 75 to 100 cm, there are no significant percent occurred, which explains due to the presence in the accumulation of pollutants in this area, the Bactria found food from the dead organisms from upper depth, after 100 cm depth the occurred due to scarcer of food due to the biochemical decomposition of organic matter and consequently, will lead to die-off of the bacteria at lower depths. The results among three days summarized in Table 2 shows the average percent of fecal and differential percent increment of -which reflect the percent improvement of at each depth. The median value for percent at 1st, 2nd, and 3rd day is 44.4%, 50%, and 60% respectively. And for the average percent the median value is 65.92% and standard division is 0.285 which reflect the sensitive effect of depth on fecal coliform. The standard division for percent at 1st, 2nd, and 3rd day is 0.327, 0.332, and 0.489 respectively, which shown the varying in percent for along depths that occurred from day to day i.e. at 3rd day there are varying in percent from depth to depth more than at 1st day or 2nd day. The correlation measured between days results, between 1st day to 2nd day is 0.993, and between 2nd day to 3rd day is 0.975 which shown that the efficiency for a day infiltration. Figure 4 shows the mathematical relation between the filter depth and the efficiency of Coliforms. The most representative equation was a polynomial Table 2. Analysis of fecal results along three days. Depth Minimum maximum Average % Differential increment 12.5 cm 0 16.7 9.27-25 cm 0 22.2 12.97 +3.7 37.5 cm 0 33.3 22.2 +9.23 50 cm 44.4 60 51.47 +29.27 75 cm 77.8 88.9 80.37 +28.9 100 cm 77.8 88.9 80.37 0 150 cm 100 100 100 +19.63 200 cm 100 100 100 0 Percent (%) 100 80 60 40 20 0 y 0.004 = x 2 + 1.429x 14.31 R² = 0.961 0 20 40 60 80 100 120 140 160 180 200 220 Depth of Filter (cm) Figure 4. Relationship between depth and percent of fecal. (2nd degree) as the factor (R2 = 0.96 which is close to 1). 3.2. Suspended Solid Removal Results of three days infiltration concluded in Table 3. Figure 5 illustrated the percent of suspended solid through 2 m of filter media versus the depths. The percent from day to day generally have a close pattern and there is no significant difference in the percentage of between them, with exception to the upper depths on the first day due to the filter body at this moment considered as the least accumulation of pollutants in comparison with the other two days. The results summarized in Table 4 shows the average percent of suspended solids and differential percent increment of -which reflect the percent improvement of at each depth. Referring to Table 4, it is noted that at depth up to 37.5 cm the average of suspended solids is 83.13 %. Thus, this depth represents the effective depth for the of suspended solids. It is also noticed that there is no significant decrease in suspended solids concentrations through the depths ranging from 37.5 cm to 100 cm with an average concentration of 14 mg/l, and similarly at depths 150 cm to 200 cm with an average concentration of 9.33 mg/l. The median value for percent at the 1st, 2nd, and 3rd day is 85.8%, 87%, and 87.5% respectively. And for the average percent the median value is 86.77% and standard division is 0.111 which mean that the effect of depth on suspended solid is not sensitive. The standard division for percent at the 1st, 2nd, and 3rd day is 0.079, 0.118, and 0.138 respectively, which shown the varying in percent for along depths that occurred from day to day i.e. at the 3rd day there are varying in percent from depth to depth more than at the 1st day or the 2nd day. The correlation measured between days results, between 1st day to 2nd day is 0.976, and between the 2nd day to the 3rd day is 0.988 which shown that the efficiency for a day infiltration. Figure 6 shows the mathematical relation between the

A. M. NASSAR, K. HAJJAJ 1011 % Percent Removal of suspende solid Percent (%) %100 %90 %80 %70 %60 %50 st Day1 nd Day2 rd Day3 0 25 50 75 100 125 150 175 200 Sand Filter Depth (cm) Figure 5. Percent of suspended solid. 100 95 90 85 80 75 70 65 60 55 50 44.99x + 0.992y = 83.05x + 0.045y = 0 20 40 60 80 100 120 140 160 180 200 Depth of Filter (cm) Figure 6. Relationship between the depth and suspended solid. Table 3. Removal of suspended solid during three days. Cumulative Depth (cm) 1st Day 2nd Day 3rd Day Suspended Solid Influent = 95 mg/l SS (mg/l) SS % Suspended Solid Influent = 100 mg/l SS (mg/l) SS % Suspended Solid Influent = 108 mg/l SS (mg/l) SS % 12.5 32 66.3% 45 55.0% 50 53.7% 25 24 74.7% 32 68.0% 42 61.1% 37.5 18 81.1% 16 84.0% 17 84.3% 50 14 85.3% 13 87.0% 15 86.1% 75 13 86.3% 13 87.0% 12 88.9% 100 12 87.4% 13 87.0% 12 88.9% 150 10 89.5% 11 89.0% 10 90.7% 200 8 91.6% 9 91.0% 8 92.6% Table 4. Analysis of suspended solid results along three days. Depth Minimum maximum % Average Differential increment % Average concentration 12.5 cm 53.7 66.3 58.33-42.33 25 cm 61.1 74.7 67.93 +9.6 32.66 37.5 cm 81.1 84.3 83.13 +15.2 17 50 cm 85.3 87 86.13 +3 14 75 cm 86.3 88.9 87.4 +1.27 12.67 100 cm 87 88.9 87.76 +0.36 12.33 150 cm 89 90.7 89.73 +1.97 10.33 200 cm 91 92.6 91.73 +2 8.33 depth of filter and the average percent of suspended solid, which can represented as follow: 0.992x 44.9970 x 38 f x 0.045x 83.058x 38 where x: depth in cm and f(x) the percent of suspended solids. 4. Conclusions 1) Use sand filter for purification the storm water can be removed fecal at the depth of 150 cm. 2) Sand filter produces effluent with less than 20 mg/l suspended solid concentration after the depth of 75 cm. 3) Percent of fecal and suspended solid through sand filter increased as the depth of the sand filter increased. 4) 80% of the of fecal occurred at the depth of 75 cm, and about 60% of influent fecal will be removed at depth ranged between 50 cm to 75 cm of filter media. 5) 83% percent of suspended solid occurred at the depth 37.5 cm. 5. Acknowledgements The authors gratefully acknowledge the funding support of the Islamic University in Gaza, which made this research possible, and gratefully acknowledge to SCIRP for their efforts to support the authors to publish the paper. REFERENCES [1] J. Balousek, Potential Water Quality Impacts of Stormwater Infiltration, 2011.

1012 A. M. NASSAR, K. HAJJAJ http://www.countyofdane.com/lwrd/landconservation/pap ers/impactsofswinfiltration.pdf [2] S. Clark and R. Pitt, Stormwater Runoff Treatment: Evaluation of Filtration Media, US Environmental Protection Agency, Water Supply and Water Resources Division, National Risk Management Research Laboratory, EPA No. 600R00010, Cincinnati, 1999. [3] R. Losco and J. Valentine, Storm water Infiltration and the Soil Landscape Connection, Pennsylvania Association of Professional Soil Scientists. 2003. http://www3.villanova.edu/vusp/outreach/pasym03/pdfs/ 3A3.pdf [4] AWWA, Standard for Granular Filter Material, American Water Works Association ANSI/AWWA B100-09, 2002. [5] A. Torrens, P. Molle, C. Boutin and M. Salgot, Impact of Design and Operation Variables on the Performance of Vertical-Flow Constructed Wetlands and Intermittent Sand Filters Treating Pond Effluent, Water Research, Vol. 43, No. 7, 2009, pp. 1851-1858. [6] D. Anderson, R. Siegrist and R. Otis, Technology Assessment of Intermittent Sand Filters, EPA No. 832R85100, 1985. [7] B. R. Urbonas, Stormwater Sand Filter Sizing and Design A Unit Operations Approach, 2008. http://www.udfcd.org/downloads/pdf/tech_papers/sand-fl t-paper.pdf [8] L. Huisman and W. E. Wood, Slow Sand Filtration, World Health Organization, Geneva, 1974, pp. 47-79. http://www.who.int/water_sanitation_health/publications/ ssfbegin.pdf [9] R. Culp, G. Wesner and G. Culp, Advanced Wastewater Treatment, 2nd Edition, Van Nostrand Reinhold Company, New York, 1978. [10] S. Farooq, A. K. Al-Yousef, R. I. Allayla and A. M. Ishaq, Tertiary Treatment of Sewage Effluent via Pilot Scale Slow Sand Filtration, Environmental Technology, Vol. 15, No. 1, 1993, pp. 15-28. [11] H. Bruijn and S. E. Clark, Research and Development of Effective Suspended Solids Removal from Storm Water Runoff in Collection Systems Using In-Line Lamella Plate Separators, Terre Hill Stormwater System Research Papers. Pennsylvania Stormwater Management Symposium, Villanova University, Villanova, 2003. http://www.terrehill.com/documents/09_19_03_villanova paperterrekleen.pdf [12] V. Ellis, Slow sand Filtration, CRC Critical Reviews in Environmental Control, Vol. 5, No. 4, 1984, pp. 315-354. [13] S. Hamdan, U. Troeger and A. Nassar, Quality Risks of Stormwater Harvesting in Gaza, Journal of Environmental Science and Technology, Vol. 4, No. 1, 2011, pp. 55-64.