SMART Digest Kit User Manual. Version 2

Similar documents
User Guide. SMART Digest Kit

SMART Digest ImmunoAffinity (IA) Kit User Manual. Version 1

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Chromatographic Workflows for Biopharmaceutical Characterization

Columns for Biomolecules BioLC Column Lines

Separation Science Built for Biopharma

CX-1 ph Gradient Buffer

NISTmAb characterization with a high-performance RP chromatography column

Simple, Robust, High Quality Intact Mass Analysis A Biosimilars Case Study

Analysis of Monoclonal Antibodies and Their Fragments by Size Exclusion Chromatography Coupled with an Orbitrap Mass Spectrometer

MAbPac RP Column. High-performance reverse phase chromatography column for monoclonal antibody analysis

Monoclonal Antibody Analysis on a Reversed-Phase C4 Polymer Monolith Column

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Chromatography column for therapeutic protein analysis

Method Optimisation in Bottom-Up Analysis of Proteins

ph gradient analysis of IgG1 therapeutic monoclonal antibodies using a 5 µm WCX column

Universal Solution for Monoclonal Antibody Quantification in Biological Fluids Using Trap-Elute MicroLC-MS Method

Thermo Scientific MAbPac HIC Columns. Novel Hydrophobic Interaction HPLC Columns. Designed for Monoclonal Antibody Analysis

Application Note. Authors. Abstract. Automated Protein Sample Preparation for LC/MS

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Simple charge variant profile comparison of an innovator monoclonal antibody and a biosimilar candidate

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Ultra-Sensitive Quantification of Trastuzumab Emtansine in Mouse Plasma using Trap-Elute MicroLC MS Method

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Application Note. Biopharma. Authors. Abstract. James Martosella, Phu Duong Agilent Technologies, Inc Centreville Rd Wilmington, DE 19808

A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies

A highly sensitive and robust 150 µm column to enable high-throughput proteomics

mabs and ADCs analysis by RP

Agilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis. WCBP Jan 2017 Washington, DC

BioHPLC columns. Tim Rice Biocolumn Technical Specialist

AdvanceBio HIC: a Hydrophobic HPLC Column for Monoclonal Antibody (mab) Variant Analysis

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column

4/4/2013. BioHPLC columns. Paul Dinsmoor Biocolumn Technical Specialist. April 23-25, Size Exclusion BioHPLC Columns

Agilent Multiple Affinity Removal Spin Cartridges for the Depletion of High-Abundant Proteins from Human Proteomic Samples.

Thermo Scientific. MAbPac HIC-10. Product Manual. P/N: June Part of Thermo Fisher Scientific

Fast and High Resolution Analysis of Intact and Reduced Therapeutic Monoclonal Antibodies (mabs)

Biochromatography Bring more Zen into your life and laboratory

Application Note. Kwasi Antwi, Amanda Ribar, Urban A. Kiernan, and Eric E. Niederkofler Thermo Fisher Scientific, Tempe, Arizona

Separation of Native Monoclonal Antibodies and Identification of Charge Variants:

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

A universal chromatography method for aggregate analysis of monoclonal antibodies

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Thermo Scientific Ligand Binding Mass Spectrometric Immunoassay (LB-MSIA)

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

Rapid quantitation of therapeutic antibodies in animal plasma

Peptide Mapping: A Quality by Design (QbD) Approach

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

Agilent AssayMAP Platform BIOLOGICS SAMPLE PREPARATION INTELLIGENTLY AUTOMATED

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

Ensure your Success with Agilent s Biopharma Workflows

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

Genome Reagent Kits v2 Quick Reference Cards

Easy Enhancements via Column Chemistry and Simplified Sample Preparation for Biosimilars. Joann Purkerson Thermo Fisher Scientific

AdvanceBio Peptide Mapping

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Accelerate mab Characterization Using Automated Sample Prep

Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns

ProPac Elite WCX, 5 μm Particle, for Fast, High Resolution Protein and mab Analysis. July 2018

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Thermo Scientific LC Columns for Biomolecules

Thermo Scientific Technical Resources Document 1.5. LC Columns and Accessories. for Biomolecules

Bioanalysis of Intact Therapeutic Monoclonal Antibodies from Non-Human Primates Using MSIA D.A.R.T. S Technology

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

EPIGENTEK. EpiQuik Chromatin Immunoprecipitation Kit. Base Catalog # P-2002 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

For the quick and efficient purification of highly specific and ultra pure antibodies

EpiQuik Methyl-CpG Binding Domain Protein 2 ChIP Kit

Peptide enrichment and fractionation

Agilent AssayMAP Bravo Platform AUTOMATED PROTEIN AND PEPTIDE SAMPLE PREPARATION FOR MASS SPEC ANALYSIS

UHPLC for Large Bio-Therapeutics

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085

Superdex 200 Increase columns

Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

A High Throughput Microchromatography Platform

Biotherapeutic Non-Reduced Peptide Mapping

Bravo with AssayMAP. Automated Sample Preparation

Ligand Binding Mass Spectrometric Immunoassay (LB-MSIA ) Workflow with Deglycosylation for Therapeutic Antibodies

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

A fast and simple workflow for surrogate peptide bioanalysis: NISTmAb case study

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

MagMAX DNA Multi-Sample Ultra Kit

Superdex 200 Increase columns

Simultaneous Quantitation of a Monoclonal Antibody and Two Proteins in Human Plasma by High Resolution and Accurate Mass Measurements

Analysis of Monoclonal Antibodies and Their Fragments by Size-Exclusion Chromatography Coupled with an Orbitrap Mass Spectrometer

Growth media effects on post-translational modifications investigated through peptide mapping LC-MS/MS analysis of anti-il8 monoclonal antibody

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

TECHNICAL BULLETIN. HIS-Select HF Nickel Affinity Gel. Catalog Number H0537 Storage Temperature 2 8 C

EpiQuik Tissue Methyl-CpG Binding Domain Protein 2 ChIP Kit

Application Note. Authors. Abstract. Biopharmaceuticals

SureCell WTA 3 Checklist. Prepare Cell and Barcode Suspension Mixes

Tissue Acetyl-Histone H4 ChIP Kit

Next Generation Technology for Reproducible and Precise Proteome Profiling

LabChip GXII: Antibody Analysis

Advanced QA/QC characterization MS in QC : Multi Attribute Method

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

Application Note. Authors. Abstract

Transcription:

SMART Digest Kit User Manual Version 2 XX21543 Revision A August 2016

SMART Digest Kit Delivering simple, fast and reproducible digestion of proteins Thermo Scientific SMART Digest kits are designed for biopharmaceutical and proteomic applications which require simple, fast and highly reproducible digestion of proteins. This is achieved through the use of optimized, heat stable, enzymes. The SMART Digest kits are available in a number of different formats to meet your workflow requirements. Part Number Description Contents Non-Magnetic Options 60109-101 SMART Digest Kit Trypsin 60109-104 SMART Digest Kit Chymotrypsin 60109-107 SMART Digest Kit Proteinase K 96 SMART Digest tubes 60109-102 SMART Digest Kit Trypsin 96 SMART Digest tubes 60109-105 SMART Digest Kit Chymotrypsin 60109-108 SMART Digest Kit Proteinase K Filter plate 60109-103 SMART Digest Kit Trypsin 96 SMART Digest tubes 60109-106 SMART Digest Kit Chymotrypsin 60109-109 SMART Digest Kit Proteinase K Thermo Scientific SOLAμ SPE plate Non-Magnetic Bulk Options 60109-101-B 60109-104-B 60109-107-B SMART Digest Kit Trypsin SMART Digest Kit Chymotrypsin SMART Digest Kit Proteinase K SMART Digest resin in bulk format 60109-102-B SMART Digest Kit Trypsin SMART Digest resin in bulk format 60109-105-B SMART Digest Kit Chymotrypsin 60109-108-B SMART Digest Kit Proteinase K Filter plate 60109-103-B SMART Digest Kit Trypsin SMART Digest resin in bulk format 60109-106-B SMART Digest Kit Chymotrypsin 60109-109-B SMART Digest Kit Proteinase K SOLAμ SPE plate 2 Thermo Scientific

Magnetic Bulk Options 60109-101-MB 60109-104-MB 60109-107-MB SMART Digest Kit Trypsin SMART Digest Kit Chymotrypsin SMART Digest Kit Proteinase K SMART Digest resin in bulk format 60109-102-MB SMART Digest Kit Trypsin SMART Digest resin in bulk format 60109-105-MB SMART Digest Kit Chymotrypsin 60109-108-MB SMART Digest Kit Proteinase K Filter plate 60109-103-MB SMART Digest Kit Trypsin SMART Digest resin in bulk format 60109-106-MB SMART Digest Kit Chymotrypsin 60109-109-MB SMART Digest Kit Proteinase K SOLAμ SPE plate Soluble Enzyme Option (For use with complex sample sets) 60113-101 SMART Digest Kit Soluble Trypsin SMART Digest soluble trypsin Product Storage It is important to store the components of the SMART Digest kits correctly to ensure the product lifetime and performance. SMART Digest tubes and resin materials store at -20 C. store at 4 C. All other components store at room temperature. The SMART Digest kits ship in cold conditions. Each kit contains a WarmMark 2 Temperature Indicator. This indicator tracks how long the kit has been at, or above, 38 C by irreversibly turning from white to blue. If on opening the kit the temperature sensor indicates that the kit has been exposed to 38 C for more than 2 hours please contact Technical Support: www.thermofisher.com/chromexpert to help determine the functionality of the SMART Digest kit. WarmMark 2 Time/Temperature Indicator Materials recommended, but not provided: Heater/shaker equipped with heated block and heated lid, capable of uniformly heating samples to 70 C. Thermo Scientific DynaMag -96 Side Magnet block for use with magnetic bead versions of kit (P/N 12331D). The Thermo Scientific KingFisher Duo Prime, or KingFisher Flex Purification Systems (P/N 5400110 and P/N 5400630 respectively) for use with magnetic bead versions of the kit (high throughput options). For use with filter plate or SOLAµ SPE plate operation: Thermo Scientific HyperSep-96 Well Plate Vacuum Manifold (P/N 60103-351). The Thermo Scientific Vacuum Pump NA option (P/N 60104-243) or EU option (P/N 60104-241). Recommended column for peptide quantification: Thermo Scientific Acclaim VANQUISH, C18, 2.2 μm Analytical (2.1 250 mm, P/N 074812-V). 2 Hours at/or above 38 C SMART Digest Kit 3

How to use your SMART Digest kit 1 2 3 Add 150 µl of buffer Add 50 μl of sample Digestion + 150 µl + 50 µl 1400 RPM 70 oc Add 150 µl of SMART Digest buffer to the SMART Digest tube. Add 50 μl of sample to the SMART Digest tube (final volume of 200 μl per sample). Set your heater/shaker to 70 C/1400 RPM, allow to equilibrate for 5 minutes. Then add your samples for the required time for digestion. Questions Answers Note: Refer to the Digestion Optimization Section. Q: Why is the temperature set to 70 C? This has been shown to be the optimum temperature for enzyme activity and the unfolding of proteins. Higher or lower temperatures may reduce the efficiency of the digestion. Q: What concentration of protein can I add to each SMART Digest tube? You can add 200 pg to 3.5 mg of total protein to each SMART Digest tube (protein/sample dependent). Q: Do I have to reduce and alkylate my protein? The SMART Digest kits are thermally stable. When operated at high temperatures denaturation and digestion occur simultaneously. Therefore, for many quantitative workflows, there is no need to perform the additional steps of denaturation, reduction and alkylation. However, during this process many disulfide bonds will remain intact. As a result, for characterization workflows where maximum sequence coverage is required, it is recommended that you perform reduction and alkylation after digestion. 4 Thermo Scientific

4 5 Cleanup Analyze 200 150 mau 100 50-10 2.5 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.5 Time (mins) Remove the SMART Digest tube from the heater/shaker and perform one of the sample cleanup methods based on the complexity of your starting matrix. Analyze sample. Note: Refer to the Post Digestion Process. Q: My protein is very difficult to unfold so I need to use urea. What concentration of urea can I use? Q: Does digestion using the SMART Digest kit at high temperatures result in an increase in post-translational modifications? The SMART Digest kit uses heat to unfold the protein. If urea is required then it is recommended to dilute the sample to 0.5 M or less of urea prior to transferring to the SMART Digest tube. Q: What if I have less than 50 µl of sample? In comparison to in-solution digests a comparable number of PTMs have been observed when screening for deamidation, amidation, methylation and oxidation. No modifications to existing PTMs, such as phosphorylated sites, have been observed. If your sample is less than 50 µl adjust to 50 µl with ultrapure water. SMART Digest Kit 5

Digestion Optimization Optimize the time for your assay Prepare eight identical samples as described previously using a relatively high, known concentration of native analyte in the matrix of operation. Digest the samples according to the Protein Digestion Procedure and periodically remove one of the samples from the well or tube (e.g. every 5 to 15 minutes). Perform the appropriate low, medium or high complexity post digestion process. Disappearance of the intact protein peak and stabilization of peptide peak intensity and peak ratios indicates a complete digestion. Once stable, the corresponding digest time can be used for subsequent analyses. By removing consecutive samples and monitoring these features the optimum digestion time can be determined. For carbonic anhydrase full digestion is complete in 5 minutes. Analyze the samples to determine the extent of digestion (see chromatogram and table below). Carbonic Anhydrase, 29 KDa Time course experiment for digestion optimization digest time 0 min 5 min 10 min 20 min 30 min 60 min 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 min Typical Digestion Times Protein Insulin 4 BSA < 5 Carbonic anhydrase < 5 Lysozyme < 5 Apo-B 30 IgG 45 IgG in 50 µl plasma* 75 Ribonuclease A 150 Thyroglobulin 240 C-reactive protein 240 Digest Time (min) 200 μl protein solution (100 μg/ml) at 70 C *IgG in plasma (17.5 mg/ml total protein) at 70 C Note: DO NOT reduce and alkylate samples prior to digestion. Chemicals used for denaturation, reduction and alkylation negatively impact the activity of the protease. If the peptides of interest require reduction and/or alkylation prior to analysis it is recommended that these steps be performed post digestion. 6 Thermo Scientific

Post Digestion Process Choose one of the methods below based on your sample complexity and analysis requirements Low complexity matrix: Centrifugation Centrifuge sample using appropriate device. Remove sample from the SMART Digest tube using a pipette, making sure not to remove beads. Transfer supernatant samples to collection plate, or appropriate sampling holder for analysis. Medium complexity: Filtration Filtration cleanup method 1 2 3 Load sample Elute peptides Analyze 200 150 mau 100 50-10 2.5 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.5 Time (mins) Load entire sample into respective well and apply vacuum. Collect sample for analysis. Analyze sample. Note: For correct manifold setup and plate alignment, see overpage. SMART Digest Kit 7

High complexity (e.g. plasma): SOLAµ SPE Plates SOLAµ SPE cleanup method 1 2 3 Condition Equilibrate Load sample 1. Position SOLAµ SPE plate on 96 well vacuum or positive pressure system as described in the manifold setup. 2. Pipette 200 µl of acetonitrile to each well and apply vacuum as described in the section practical considerations for filtration and SOLAµ SPE use. 3. Discard the effluent. 1. Pipette 200 µl of 0.1% trifluoroacetic acid in water to each well and apply vacuum as described in the section practical considerations for filtration and SOLAµ SPE use. 2. Discard the effluent. 1. Prepare sample by diluting 1:1 with 0.1% trifluoroacetic acid in water. 2. Load entire sample into respective well and apply vacuum as described in the section practical considerations for filtration and SOLAµ SPE use. 3. Discard the effluent. Manifold setup and plate alignment Filtration plate OR SOLAµ SPE plate Vacuum manifold top 96-well collection plate in the vacuum manifold base To vacuum pump Points to consider No gap between filter/solaµ plate and collection plate. When under vacuum filter/solaµ plate will be held tightly in position. 8 Thermo Scientific

4 5 6 Wash Elute peptides Analyze 200 150 mau 100 50-10 2.5 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.5 1. Pipette 500 µl of 0.1% trifluoroacetic acid in water to each well and apply vacuum as described in the section practical considerations for filtration and SOLAµ SPE use. 2. Discard the effluent. 1. Pipette 25 µl of 70% acetonitrile in water to respective wells as described in the section practical considerations for filtration and SOLAµ SPE use. 2. Repeat this process until a total volume of 50 µl has passed through the plate. 1. To your sample add 50 µl of 0.1% formic acid and mix prior to analysis. 3. Collect sample in appropriate vessel for analysis. Practical considerations for the use of filtration and SOLAµ SPE plates 1. Using an accurate pipette, aspirate the specified volume of either solvent/reagent, or sample. 3. Apply a gentle vacuum and increase the pressure until the liquid begins to flow through the filtration, or SOLAµ SPE plate. 2. Dispense solvent/ reagent or sample into a unique well of the filtration or SOLAµ SPE plate. Up to 96 wells can be used simultaneously. 4. The collected eluent is then kept for analysis. Note: The effluent from each load/wash step may also be collected and analyzed if method optimization is required. SMART Digest Kit 9

How to use the SMART Digest bulk or magnetic kit 1 2 Re-suspend Aliquot 15 µl of resin + 15 µl 35 30 25 20 15 10 7.5 5.0 35 30 25 20 OR 15 10 7.5 5.0 Thoroughly vortex tube containing SMART Digest bulk resin. Take 15 µl of SMART Digest bulk resin (magnetic or non-magnetic) and add to an appropriate well (deep well plate, PCR plate, PCR strip, or 1.5 ml tube). 5 6 Digestion Cleanup 1400 RPM 70 oc Set your heater/shaker to 70 C/1400 RPM, allow to equilibrate for 5 minutes. Then add your samples for the required time for digestion. Remove the SMART Digest tube from the heater/ shaker and perform one of the sample cleanup methods based on the complexity of your starting matrix. Note: For the magnetic bead option it is recommended that a SOLAµ SPE plate cleanup step is performed. Note: Refer to the Digestion Optimization Section. Note: Refer to the Post Digestion Process. 10 Thermo Scientific

3 Add 150 µl of buffer 4 Add 50 µl of sample + 150 µl + 50 µl Add 150 µl of SMART Digest buffer to the well/tube containing the SMART Digest resin. 7 Analyze Take 50 μl of sample and add to the well/tube containing the SMART Digest resin (final volume of 200 μl per sample). Seal the well/tube. Note: When using a deep well plate the use of cap mats are recommended (Thermo Scientific Matrix SepraSeal caps P/N 4463). When using a PCR plate the use of iron-on seals are recommended. 200 150 mau 100 50-10 2.5 Analyze sample. 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.5 Time (mins) SMART Digest Kit 11

How to use the SMART Digest soluble kit 1 Add 150 μl of buffer 2 Add 50 μl of sample + 150 µl + 50 µl OR Add 150 µl of SMART Digest buffer to the well/tube. Add 50 μl of sample to the well/tube (final volume of 200 μl per sample). Seal well/tube. 5 6 Quench Cleanup Remove sample tube/well from heater. Allow to cool. Remove 175 μl of sample and transfer to a tube containing 175 μl of 1% trifluoroacetic acid in water. Perform one of the sample cleanup methods based on the complexity of your starting matrix. Note: Refer to the Post Digestion Process. 12 Thermo Scientific

3 4 Add 5 μl of trypsin Digestion + 5 µl 70 oc Add 5 μl of SMART DIgest soluble trypsin. 7 Analyze Set your heating apparatus to 70 C (no shaking required) allow to equilibrate for 5 minutes. Then add your samples for the required time for digestion. Note: Refer to the Digestion Optimization Section. 200 150 mau 100 50-10 2.5 Analyze sample. 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.5 Time (mins) SMART Digest Kit 13

Columns and Consumables for Biopharma A full range of Thermo Scientific columns are available for Biopharma applications including affinity, ion exchange, reversed phase, hydrophobic interaction, and size exclusion. Peptide Mapping Size Exclusion Charge Variant Analysis Intact Proteins Glycan Analysis Detection UV / UV-MS UV / UV-MS UV UV / UV-MS FLD and FLD-MS Application goal Confirm sequence Check monomer versus aggregates Check charge variation within antibody sample Check purity of the antibody Check glycan presence and structure Recommended products Acclaim PepMap column SMART Digest kit SOLAµ SPE EASY-Spray column MAbPac SEC-1 column MAbPac SCX-10 ph Gradient Buffer MAbPac RP column MAbPac HIC column GlycanPac AXH-1 and AXR-1 columns Accucore 150-Amide-HILIC column Benefits Retention reproducibility Reproducible LC/MS compatible Ultra-high resolution Rugged Low carryover High resolution More information 14 Thermo Scientific

Upgrade your maps with a complete workflow for biotherapeutic protein characterization Magnify the advantages that SMART Digest kits bring to your peptide mapping workflows, with time-saving UHPLC, MS and software technologies. Faster and more reproducible separations Engineered to build your drug pipeline The Vanquish UHPLC family was built for biopharma characterization. High pressure bio-inert flow paths and SmartInject (intelligent sample pre-compression prior to injection) ensures high peak capacity, retention time stability and peak area precision - ideal for peptide mapping applications. Multiple thermostatting options and adjustable gradient delay volume means that you can seamlessly transfer peptide mapping methods from any LC-MS to LC-UV as your drug candidate moves from development to routine QC. Say goodbye to your Q-TOF The Orbitrap you love now excels in both peptide mapping and intact mass analysis Realize complete biopharmaceutical characterization with the new Thermo Scientific Q Exactive BioPharma platform. The platform offers new operational modes optimized for three protein characterization workflows; High Mass Mode for intact and native high molecular weight proteins and ADCs; Protein Mode for antibody fragments and spectral resolution; and Standard Mode that performs peptide mapping with unparalleled acquisition speed and accuracy. Go from vial to file with new mapping and intact protein software. 100% coverage peptide mapping and intact protein characterization in one package The Thermo Scientific BioPharma Finder Software gives you the ability to perform sequence variant searching, disulfide link analysis, de novo sequencing with relative quantitation of post-translational modifications, and comparability studies. BioPharma Finder assures that you won t miss a thing in your sample. The multiple interactive plot display options mean you can see what you want, when you need it. SMART Digest Kit 15

Characterize the full diversity of biomolecules Thermo Scientific solutions for biomolecule separations SOLAµ SPE Plates MSIA D.A.R.T.s Versette Automated Liquid Handler WebSeal KingFisher Flex Purification System Sample Preparation Sample Handling Separation and Detection Data Management BioLC/UHPLC Columns Watson LIMS and Data Manager BioPharma Finder Mass Informatics Platform Q Exactive BioPharma Platform Vanquish UHPLC System Find out more at thermofisher.com/smartdigest For Research Use Only. Not for use in diagnostic procedures. 2016 Thermo Fisher Scientific Inc. All rights reserved. WarmMark 2 is a trademark of ShockWatch, Inc., US. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. XX21543-EN 1016S