TUNNELS III.

Similar documents
Product information Sun tunnels TCF and TCR for flat roofs and roofing felt materials

CI/SfB (37.4) Xa Uniclass L414 October SUNSCOOP TUBULAR ROOFLIGHTS ...

FLAT ROOF WINDOW STRUCTURE

LOFT MARCH LADDERS.

FLAT ROOF WINDOW STRUCTURE

FLAT ROOF SYSTEM PRODUCTS

NRC CONSTRUCTION TECHNOLOGY UPDATE

SQUARE SUN TUNNEL INSTALLATION INSTRUCTION

Sun Tunnel Skylights

Sun Tunnel Skylights. Bright Natural Light. Quick Installation.

Product information Rod operated flat roof window CVP

SKYTEX Light and Ventilation Ridge. Agricultural product for Light and Air

IBC Mounting Systems. System solutions for all application areas

Commercial Sun Tunnel Skylights Capturing daylight for the workplace

Poor distribution & glare

Product information Flat roof exit window CXP

FLAT ROOF SYSTEM PRODUCTS

SKYLIGHTS ROOFLIGHTS FLAT ROOF WINDOWS. let the sunlight come in

Domes Pyramids Opening Rooflights Flatglass Rooflights

Product information Top-operated centre-pivot polyurethane roof window GGU

ATI Evaluation Service A Division of Architectural Testing Certification Services

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

Product information Centre-pivot white-painted roof window GGL

Kingspan Day-Lite Kapture Data Sheet

Product information Rescue opening window GTL

Product information Top-hung roof window GPL

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

OPERABLE DAYLIGHTING SYSTEM

Product information Top-hung white polyurethane roof window GPU

Aluminum Secondary Glazing Specification Guide June 2012

G U T T E R SY S T E M

Product information Additional window element GIU

Product information Roof balcony CABRIO GDL

Commercial & Residential Daylighting Systems

Company DUOL. Dušan Olaj CEO

Approaching towards innnovation. An ISO 9001:2015 Certified company

Product information Roof balcony CABRIO GDL

J41 Reinforced bitumen membrane roof coverings

Product information Flat roof smoke ventilation window CSP

Product information Additional window element GIL

Product information Fixed flat roof window CFP

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

Product information Vertical window element VIU

DEPLOSUN GLASS TOP DEPLOSUN ARTIC ROUND GLASS TOP PRODUCT DATASHEET

STANDARD 27: TUBULAR SKYLIGHT INSTALLATIONS

New versatile and effective dry fix solutions for the roofline and above

Product information Vertical window element VFE

Product information Roof terrace GEL + VEA/VEB/VEC

ECOTOP VF-HF. high efficiency glazed flat-plate solar collectors > MAXIMUM MODULARITY > SIMPLIFIED INSTALLATION

Design & Construction Standards, Revised January

Roofing. Sarnafil G EL Felt. Polymeric membrane for roof waterproofing. Product Description

Commercial skylights edition

110HC SUN LOUVRE. Sun Control Systems

Contents P/ 3. Ensuring Optimal Results P/ 4. Roof Insulation SF40 P/ 5. Roof Insulation Over Rafter Application P/ 6

10 EXTREME BASEMENT PANELS

Leading in integration for partial- and full roofs: Photovoltaic in-roof mounting system Solrif by Schweizer.

F Ü R D I E ZU K U N FT G E DAC HT. Flat roof vents. Soil vent pipes Refurbishment vents Cold roof vents

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Parabond 600 Elastic glue and adhesive with extremely high initial bonding

ENERGY EFFICIENT GLASS LESS ENERGY, MORE SAVINGS, BETTER FUTURE

Warmer Roof. Transforming conservatory roofs. WarmerRoof

CASSETTE BS Specification book

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Curtain Wall Stick System (Capped)

Alfa Roof 40/3-40/10-40/25

BY HARNESSING THE POWER OF THE SUN WE ARE ABLE TO PRODUCE HOT WATER AND ELECTRICITY FROM AN INEXHAUSTIBLE SOURCE WITHOUT ADDING TO THE CARBON LEVELS

COVERING MATERIALS: ROOFING, WALLS AND HEADS

AEROFOILS 200AF-450AF. Sun Control Systems

Creative Roofscaping. Crest concrete interlocking roof tile collection. High quality micro concrete roof tiles for every type of project.

Creative Roofscaping. Crest concrete interlocking roof tile collection. High quality micro concrete roof tiles for every type of project.

THE LABAN DANCE CENTRE DEPTFORD, LONDON, UK

imperband refurbishing kit

Quality specifications for my home

ILKAclean Clean Room Systems

Installation Instructions ALUTRIX 600 ALUTRIX FR

ROOFLIGHTS & VERTICAL GLAZING

Commercial Skylights. Dynamic Dome Skylight. whyskylights.com 1

Market leading LED flat panels

INDEX COMPOSITE PANELS 3 POLYCARBONATE ROOFLIGHTS 13 FLASHINGS 13 METAL SHEETS 14 ROOFTILES 18 COLOR CHART 20

ROOFING UNDERLAYS AND MEMBRANES.

April Section 5. Basements

HOME & BUSINESS IMPROVEMENTS BE CLEVER... BE SAFE... BROCHURE 2017

Guide to Choosing The Correct Covered Walkway Solution

ROYALO roof windows 20 years of warranty for roof windows 5 years of warranty for vertical windows 5 years of warranty for skylights

European Timber Windows & Doors

Solatube Natural Lighting

Project comparison: old system. One-to-one fixture replacement without changing the existing electrical system

SUN LOUVRES. Allux Metal ceiling systems. Zagorska Jakovlje - Zagreb. Tel.: Fax:

BUILDING SPECIFICATIONS

High-Spanning Glazing System Technical Guide.

SYSTEMS IN CELLULAR POLYCARBONATE

PLASTIC MATERIALS COLOURS. Plastic colour code. Steel colour. TRESTON Industrial Furniture TRESTON ESD products

Original Scandinavian rainwater system

Product information VELUX INTEGRA flat roof window CVP with curved glass cover ISD

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

DTFN Elite. Optics. IP65/54 recessed luminaire with sealed two frame construction. Jacking Bracket

PRODUCT DESCRIPTION. ESSERTEC Natural Light Spotlight. lightube

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

Transcription:

F FOLDER TUNNELS 2009 2015 III www.fakro.pl

SUN FAKRO light tunnels are designed to bring natural light to every part of a property. The light tunnel makes it possible to illuminate all rooms in the building, even those which cannot be fitted with roof windows or vertical windows. Dimly lit interiors such as bathrooms, dressing rooms, corridors, staircases or basements can be particularly uncomfortable to use. The light tunnel, enhancing the user s comfort and saves energy. The amount of light which enters the room through the light tunnels depends on the light intensity outside the building. The more light that illuminates the dome of the light tunnel, the more light is conveyed into the building interior. The diagram below illustrates the full amount of daylight (lm) depending on the month and cloudiness measured at the light tunnel dome. [ lm ] [ month ] sunny day cloudy day 2

HOUS FULL E OF SUNSHIN E The amount of light entering the room is dependent on the location of the dome. When planning the installation of the light tunnel, the following elements should be taken into account: Place the dome on a south facing roof which is the most illuminated part of the roof and avoid shady places. Locate the light transmitting tube in such a way that it travels the shortest possible distance between roof and ceiling. Install the light tunnel to ensure the best possible tension (light tunnel with flexible tube). www.fakro.co.uk 3

TUNNELS A source of natural light should be available in any living space. Unfortunately, there are interiors in which the use of vertical or roof windows is not feasible. Rooms devoid of daylight are dark and uncomfortable. To ensure illumination in such places, installing a light tunnel will channel natural light to the centre. Light tunnels can constitute the main or additional light source in any room. The light tunnel carries daylight via the light transmitting tube. Sunlight is reflected from the walls of the highly reflective tube and is directed downwards to the diffuser. The diffuser which is fitted in the ceiling evenly distributes natural light, illuminating the room. Depending on the user s requirements, colour of walls (possible diffusion and reflection of the light) and furniture The same room without windows and with an asymmetrical light tunnel placement can only be justified in order A simplified light distribution below the light tunnel s diffuser in the middle of the room without windows. placement - this is a basic scheme for light tunnel location in a room with a window. With two different sources of daylight, corner areas are not of great importance in this configuration and are pretty well illuminated. The placement of a light tunnel too close to a wall opposite to a window may diminish the overall light in the middle zone. to secure better illumination of a particular zone (e.g. a computer desk). In other instances this positioning of the light tunnel is disadvantageous. 4

SYMBOL SR_ SR_-L SF_ SF_-L SRT SLT TYPE FLAT FLAT WITH ILLUMINATION FLAT FLAT WITH ILLUMINATION WITH THE DOME WITH THE DOME TRANSMITTING TUBE RIGID RIGID FLEXIBLE FLEXIBLE RIGID FLEXIBLE FLASHING INTEGRATED INTEGRATED INTEGRATED INTEGRATED ANY TYPE ANY TYPE KIT (OPTION) YES YES 1. Flat light tunnels: Flat light tunnels have elements which are mounted low in the roof and do not protrude beyond its structure and go perfectly well with a uniform roof surface: SR_ light tunnel with rigid light transmitting tube and integrated flashing. It is also available in SR_- L version which illuminates with natural light the space directly below the installation of light tunnel s outer element e.g. attic or loft. SF_ light tunnel with flexible light transmitting tube and integrated flashing. It is also available in SF_- L version with illumination of the space directly below the installation of light tunnel s outer element e.g. attic or loft. 2. Light tunnels with dome: The SRT light tunnel with dome and rigid light transmitting tube. An appropriate flashing must be chosen for the light tunnel. It is also possible to install the SLO light kit. The SLT light tunnel with the dome and flexible light transmitting tube. An appropriate flashing must be chosen for the light tunnel. It is also possible to install the SLO light kit. Srz Sfz SRT SLT www.fakro.co.uk 5

WITH RIGID TRANSMITTING TUBE: SR_ SR_-L WITH RIGID TRANSMITTING TUBE AND ILLUMINATION WITH NATURAL FLAT TUNNEL WITH RIGID TRANSMITTING TUBE: SR_ with rigid light transmitting tube. SR_-L with rigid light transmitting tube and illumination of the loft with natural light. The light tunnel fitted in the ceiling ensures the comfortable use of the room. Features of the new light tunnel design: - Approximately10% more U heat transfer co-efficient when compared to a version with a dome. - Integrated flashing for faster installation of the light tunnel. The SR_ light tunnel consists of: roofing element, three section light transmitting tube - SRM 61cm, SRK elbow*, ceiling frame, prismatic diffuser and installation kit. The total length of sections connected in a straight line is 2.1m (SR_ 550 1.8m). RIGID TRANSMITTING TUBe The light transmitting tube is made of aluminium, covered with a highly reflective silver based layer, characterized by a high efficiency light reflective factor of over 98% (compared to a new mirror reflective factor of 90-95%). Minimal light transmittance loss enables SR_ light tunnels with a tube length of up to 12m to be specified. When installing the light transmitting tube, there is no need to cut to size the sections as the tube design is telescopic. Simply push one section deeper inside the other in order to attain the proper tube length. ROOFING ELEMENT This consists of an aluminium frame into which 4mm thick toughened glass is bonded. The light transmitting tube is fitted to the inside profile of the frame. The roofing element is made of aluminium sheet metal or special organic glass (L version with additional illumination of the loft) and is integrated with the flashing. The entire structure is finished in grey-brown RAL 7022 which matches perfectly all standard colours of roof covering materials. CEILING FRAME The new ceiling frame is made of organic glass and is equipped with a built-in light diffusing element. The cover is manufactured of high-impact polystyrene in a white opaque colour. Ceiling elements of flat light tunnels are more rounded in comparison to light tunnels with a dome. ELBOW The SRK elbow changes the angle of the light transmitting tube in the range of 0-65. For the SR_ and SR_-L 550 light tunnel, the SRK elbow is only available as an option. Installation pitch: 15-60 DIAMETER [mm]: 250 350 550 SR_ 6 * For the SR_ 550 and SR_-L 550 light tunnel, the SRK elbow available only as an option.

www.fakro.co.uk 7

WITH FLEXIBLE TRANSMITTING TUBE SF_ SF_-L WITH FLEXIBLE TRANSMITTING TUBE AND ILLUMINATION WITH NATURAL FLAT TUNNEL WITH FLEXIBLE TRANSMITTING TUBE: SF_ with flexible light transmitting tube SF_-L with flexible light transmitting tube and illumination of the loft with natural light. The light tunnel fitted in the ceiling ensures comfortable use of the room. Features of the new light tunnel design: - Approximately10% more U heat transfer co-efficient when compared to a version with a dome. - Integrated flashing for faster installation of the light tunnel. The light tunnel consists of: roofing element, flexible light transmitting tube 2.1m long, ceiling frame, prismatic diffuser and installation kit. FLEXIBLE TRANSMITTING TUBE The light transmitting tube is made of metallised polyester, additionally reinforced with metal wire. This design produces a robust and flexible light transmitting tube which is ideal for installation over short distances in rooms with structural obstacles that have to be bypassed. The advised maximum flexible tube length is 4m for the 350mm diameter tube and 6m for the 550mm diameter tube. ROOFING ELEMENT This consists of an aluminium frame into which 4mm thick toughened glass is bonded. The light transmitting tube is fitted to the inside profile of the frame. The roofing element is made of aluminium sheet metal or special organic glass (L version with additional illumination of the loft) and is integrated with the flashing. The entire structure is finished in grey-brown RAL 7022 which matches perfectly all standard colours of roof covering materials. CEILING FRAME The new ceiling frame is made of organic glass and is equipped with a built-in light diffusing element. The cover is manufactured of high-impact polystyrene in a white opaque colour. Ceiling elements of flat light tunnels are more rounded in comparison to light tunnels with a dome. Installation pitch: 15-60 DIAMETER [mm]: 350 550 SF_ 8

www.fakro.co.uk 9

TUNNEL WITH RIGID TRANSMITTING TUBE TUNNEL WITH RIGID TRANSMITTING TUBE The SRT light tunnel consists of: roofing element, three section light transmitting tube - SRM 61cm, SRK elbow*, ceiling frame, prismatic diffuser and installation kit. The total length of sections connected in a straight line is 2.1m (SR_ 550 1.8m). SRT DOME The dome is made of a polycarbonate material which has a high co-efficient of light transmittance and is robust to resist mechanical damage. The shape of the dome allows for easy cleaning. The low electrostatic activity of the dome s surface ensures dust adheres lightly to its surface only and consequently rain quickly washes the dirt away. The dome s shape also assists in the easy removal of fresh and heavy snow. FLASHING Flashing is used to ensure correct light tunnel installation in the roof slope. The Flashing collar is equipped with drip openings which can drain away potential condensate outside the light tunnel. In the middle of the flashing there is a reflective ring the first element reflecting the light which enters into the light tunnel via the dome. RIGID TRANSMITTING TUBE The light transmitting tube is made of aluminium, covered with a highly reflective silver based layer, characterized by a high efficiency light reflective factor of over 98% (compared to a new mirror reflective factor of 90-95%). Minimal light transmittance loss enables SRT light tunnels with a tube length of up to 12m to be specified. When installing the light transmitting tube, there is no need to cut to size the sections as the tube design is telescopic. Simply push one section deeper inside the other in order to attain the proper tube length. ELBOW The SRK elbow changes the angle of the light transmitting tube in the range of 0-65. For the SRT 550 light tunnels, the SRK elbow is only available as an option. CEILING FRAME with diffuser The white ceiling frame and prismatic diffuser are the only elements visible in the ceiling once the light tunnel is installed. The diffuser spreads light evenly throughout the room. It consists of transparent and prismatic diffusers, resistant to UV. Both diffusers are placed inside the unit which combines them into one entity. There is an air chamber between diffusers which fulfils the role of insulation between the room interior and light transmitting tube. It minimises the level of condensation inside the light transmitting tube. Installation pitch: 15-60. With SFP and SLP system: 0-15. DIAMETER [mm]: 250 350 550 SRT 10 * For the SRT 550 light tunnel, the SRK elbow is only available as an option.

www.fakro.co.uk 11

TUNNEL WITH FLEXIBLE TRANSMITTING TUBE TUNNEL WITH FLEXIBLE TRANSMITTING TUBE The SLT light tunnel consists of: dome, flexible light transmitting tube 2.1m long, ceiling frame, prismatic diffuser and installation kit. SLT DOME The dome is made of a polycarbonate material which has a high co-efficient of light transmittance and is robust to resist mechanical damage. The shape of the dome allows for easy cleaning. The low electrostatic activity of the dome s surface ensures dust adheres lightly to its surface only and consequently rain quickly washes the dirt away. The dome s shape also assists in the easy removal of fresh and heavy snow. FLASHING Flashing is used to ensure correct light tunnel installation in the roof slope. The Flashing collar is equipped with drip openings which can drain away potential condensate outside the light tunnel. In the middle of the flashing there is a reflective ring the first element reflecting the light which enters into the light tunnel via the dome. FLEXIBLE TRANSMITTING TUBE The light transmitting tube is made of metallised polyester, additionally reinforced with metal wire. This design produces a robust and flexible light transmitting tube which is ideal for installation over short distances in rooms with structural obstacles that have to be bypassed. The advised maximum flexible tube length is 4m for the 350mm diameter tube and 6m for the 550mm diameter tube. CEILING FRAME with diffuser The white ceiling frame and prismatic diffuser are the only elements visible in the ceiling once the light tunnel is installed. The diffuser spreads light evenly throughout the room. It consists of transparent and prismatic diffusers, resistant to UV. Both diffusers are placed inside the unit which combines them into one entity. There is an air chamber between diffusers which fulfils the role of insulation between the room interior and light transmitting tube. It minimises the level of condensation inside the light transmitting tube. Installation pitch: 15-60. With SFP and SLP system: 0-15. DIAMETER [mm]: 350 550 SLT 12

www.fakro.co.uk 13

FLASHINGS FOR TUNNELS WITH DOME FLAT ROOF SYSTEM FOR TUNNELS WITH THE DOME SLS The SLS flashing is suitable for flat roof coverings up to 10mm (2 layers x 5mm) thickness e.g. roofing felt, shingles, slates. SLP Light tunnels are very often used in flat roofs. For their proper installation, the set containing the: SFP insulated base and SLP flashing should be used. SLZ The SLZ flashing is applied to roof coverings with a profile depth of up to 45mm such as tiles and profile metal sheeting. SFP The SFP base is made of galvanized steel and insulated inside with styrofoam. SLH The SLH flashing is used for roof coverings with a profile depth of up to 90mm e.g. roof tile, high profile metal sheeting. ACCESSORIES FOR TUNNELS SLM SLM flexible light transmitting tube extension kit. The kit includes: connecting ring, light transmitting tube 120cm section, adhesive tape. It is possible to order the light transmitting tube in other lengths, but they have to be calculated as units of 30cm (e.g. 60cm, 90cm, 150cm). SRM The SRM rigid light transmitting tube extension element with a length of 61cm. SRK The SRK elbow changes the angle of light transmitting tube in the range of 0-65. For the SR_ 550 light tunnel (with rigid tube), the SRK elbow is only available as an option. SLC SLC hanger is used when an overall light transmitting tube is longer than 5m. Hangers are used in order to take part of the tube s weight and to prevent it from tearing away from the light tunnel flashing. SRC SRC hanger is used when rigid light transmitting tube length exceeds 4m. It takes part of the tube s weight. ACCESSORIES FOR TUNNELS WITH DOME SLO SLO light kit is applied as an alternative source of illumination at night. The light kit is fitted inside the light tunnel. 14

FLAT TUNNELS RIGID TRANSMITTING TUBE light tunnel diameter [mm] 250 350 550* tube length [cm] 210 210 180 FLAT TUNNELS with illumination function RIGID TRANSMITTING TUBE light tunnel diameter [mm] 250 350 550* tube length [cm] 210 210 180 SRS for flat roof coverings (2x5mm) SRZ for corrugated roof coverings (45mm) SRH for high profile roof coverings (120mm) SRL for flat plain tile roof coverings SRS-L for flat roof coverings (2x5mm) SRZ-L for corrugated roof coverings (45mm) SRH-L for high profile roof coverings (120mm) SRL-L for flat plain tile roof coverings FLAT TUNNELS FLEXIBLE TRANSMITTING TUBE light tunnel diameter [mm] 350 550 tube length [cm] 210 210 FLAT TUNNELS with illumination function FLEXIBLE TRANSMITTING TUBE light tunnel diameter [mm] 350 550 tube length [cm] 210 210 SFS for flat roof coverings (2x5mm) SFZ for corrugated roof coverings (45mm) SFH for high profile roof coverings (120mm) SFL for flat plain tile roof coverings + + + + + + + + SFS-L for flat roof coverings (2x5mm) SFZ-L for corrugated roof coverings (45mm) SFH-L for high profile roof coverings (120mm) SFL-L for flat plain tile roof coverings + + + + + + + + TUNNELS WITH DOME HANGERS light tunnel diameter [mm] 250 350 550* tube length [cm] 210 210 SRT-180 SLT -210 SRT light tunnel with rigid light transmitting tube SLT light tunnel with flexible light transmitting tube + + light tunnel diameter [mm] 250 350 550 SRC element stabilizing rigid light transmitting tube SLC element stabilizing flexible light transmitting tube TUBE EXTENSION KIT + + light tunnel diameter [mm] 250 350 550 UNIVERSAL FLASHINGS FOR TUNNELS WITH DOME light tunnel diameter [mm] 250 350 550 SLS for flat roof coverings (2x5mm) SLZ for corrugated roof coverings (45mm) SLH for high profile roof coverings (120mm) SFP insulated base for flat roofs SLP insulated base with SFP for flat roofs SRM rigid light transmitting tube extension element with a length of 61cm SRK elbow for light tunnels with rigid light transmitting tube SLM flexible light transmitting tube extension element with a length of 120cm + + * For the SR_ 550, SR_-L 550 and SRT 550 light tunnel, the SRK elbow is only available as an option. ACCESSORIES FOR TUNNELS WITH DOME light tunnel diameter [mm] 250 350 550 SLO light kit fitted inside light tunnel - order processing time - 8 working days - order processing time - 15 working days - order processing time - 25 working days www.fakro.co.uk 15

FAKRO GB LTD FAKRO HOUSE ASTRON BUSINESS PARK HEARTHCOTE ROAD SWADLINCOTE DE11 9DW TELEPHONE : 01283 554755, FAX : 01283 224545 WWW. FAKRO.CO.UK, E-MAIL: SALES FAKROGB.COM FAKRO reserves the right to change specifications at any time. FS/16str/GB/10.03.2015 G04A