June Non - Residential Refurbishment Internal lining walls

Similar documents
June Non - Residential Refurbishment 5.5 Basements

June Residential Refurbishment Basements

June Residential New Build Timber Frame Walls

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

June Non - Residential New Build Partition walls

April Section Cladded Walls

June Residential New Build Render and cladding walls

June Residential Refurbishment Exposed soffit floors

June Residential Refurbishment Separating walls

Suspended timber upper floors

August 2008: Issue 1. Non - Residential New Build Built - up Metal Walls

Light steel frame walls

August 2008: Issue 1. Non - Residential New Build Built-up Metal Roofs

April Section 5. Basements

June Non - Residential New Build Masonry cavity walls

Why party wall insulation is required

April Section Party Walls

June Residential Refurbishment Masonry cavity walls

June Non - Residential Refurbishment Separating floors

August 2008: Issue 1. Non - Residential New Build Masonry Cavity Walls

4.1 Ground Floors. Ground floors. Ground floor design. Technical Support Team

June Residential Refurbishment Separating floors

April Section Internal Walls

December The Pocket Guide To Insulation

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

How glass or rock mineral wool works in a wall or floor cavity

March The Pocket Guide To Insulation

April Section 3.3. Built-up Metal Walls

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

April Section 2.4. Built-up Metal Roofs

Polyfoam Floorboard For thermal insulation of floors

April Section 4.3. Separating Floors

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Thermal Laminate Board.

URSA TF Roll URSA GLASSWOOL.

August 2008: Issue 1. Non - Residential New Build Pitched Roofs - Ceiling Level

Flat roofs. Flat roof design. 2.3 Flat Roofs

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

GypLyner UNIVERSAL Metal framed wall lining system

April Section 4.1. Ground Floors

GypLyner UNIVERSAL Metal framed wall lining system

Superior Performance Phenolic Insulation SR/TB. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls AS LOW AS

SWIP SOLID WALL INTERNAL WALL INSULATION SYSTEM

K17 Insulated Plasterboard

PIR Insulation XT/TL-MF. Insulation for Drylining Walls (Mechanically Fixed) Walls 04/ /0183

PIR Insulation XT/TL. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls 04/ /0183

Thermal bridging. Acoustic performance

K17 Insulated Plasterboard

Multi-layer Insulation Blanket for Walls

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

URSA MINERAL WOOL URSA Timber Frame Roll & URSA Timber Frame Slab

Jabfloor High Performance (HP) 70 and 100

Multi-layer Insulation Blanket for Walls

The Pocket Guide To Insulation May 2013

GypLyner IWL Independent wall lining system

Certificate No: EW496A

URSA MINERAL WOOL URSA Cavity Batts

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

A Handbook of thermal bridging details incorporating aircrete blocks

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

URSA Cavity Batts URSA GLASSWOOL.

Multi-layer Insulation Blanket for Walls

June Residential New Build 2.0 Code For Sustainable Homes

GypLyner (walls) Metal framed wall lining system. GypLyner.

Multi-layer Insulation Blanket for Walls

CALL TO TALK TO THE SAS TEAM

K18 Insulated Plasterboard

K17 Insulated Plasterboard

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Product & Installation Guide for New Build & Refurbishment Projects. exceeding the performance criteria of all current Building Regulations

Specifications for Insulation Board wall and ceiling applications

HP Partial Fill. Robust, long-lasting protection

ThermoShell Internal Wall Insulation (IWI) Knauf Insulation

Multi-layer Insulation Blanket for

Superior Performance PIR Insulation. XO/FB Insulaton for Steel & Timber Frame. Walls 12/4956

Refurbishment site guidance for solid-walled houses ground floors

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

Superior Performance PIR Insulation XO/FB. Insulaton for Steel & Timber Frame. Walls 12/4956

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

Knauf Wall Liner. Head Track. Brackets. Wall Lining Stud. Fixings. Knauf Plasterboard. Floor Track. 98 Wall Liner

K12 Framing Board. Insulation

Jabfloor 70, 100, 150, 200, 250

PRODUCT & INSTALLATION GUIDE

April Section 2.5. Green Roofs

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

K5 External Wall Board

C07. S03. P02 P24 DriLyner basic, tl, mf, rf

Concrete Soffit Direct Fix

HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES GTEC THERMAL BOARD WITH PLASTERBOARD

Jabfloor is also available in higher grades up to Jabfloor 250 which may be required in certain specialist industrial and commercial applications.

K5 External Wall Board

URSA GLASSWOOL URSA 10 Loft Roll

A Handbook of thermal bridging details incorporating aircrete blocks

Basement Board High Performance (HP) 70 and 100

APPROVALS. Jabwall has been approved for this application since 1979, and was the first partial-fill insulation product to gain BBA approval.

GypWall QUIET Acoustic separating wall system

RW SEMI-RIGID AND RIGID SLABS (RWA45, RW3, RW4, RW5 & RW6)

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS

Transcription:

June 2010 Non - Residential Refurbishment 5.3.4 Internal lining walls

Non-residential refurbishment 5.0 Non-residential Refurbishment Internal Lining Walls Contents Introduction find online page Solution optimiser and pathfinder 454 Design Details 614 find online page Dry lining Il01 614 Independent lining Il02 616

5.3.4 Non-residential refurbishment: Walls Internal lining walls Solution optimiser and pathfinder Internal linings Construction compatibility with Part L2B Max. U-value for replacement and upgraded thermal elements - England and Wales and Northern Ireland Max. U-value for new thermal elements - England and Wales and Northern Ireland Elemental U-value requirement Knauf Insulation solution U-values 0.37 0.36 0.35 0.34 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.22 0.21 0.20 Insulated dry lining** Product*: Polyfoam Linerboard Description: XPS insulated plasterboard fixed directly to masonry Page No: 614 Il01 Independent lining** Product*: Earthwool DriTherm Cavity Slab and Earthwool Flexible Slab Description: Independent metal frame with glasswool insulation between the frame and wall, rock mineral wool insulation between the studs Page No: 616 Il02 Knauf Insulation offers a range of products for the thermal upgrade of existing masonry walls by the addition of a an internal lining. It is unlikely that walls for new extensions will be designed to require thermal internal lining and the insulation can be placed more sensibly in the cavity. Key Pb01 U-values achievable by constructions within this document. * Recommended Knauf Insulation product(s). Other products may be applicable. Find online. Visit www.knaufinsulation.co.uk and key in construction code to find the most up to date information on your chosen solution. ** Masonry is assumed to be dense, medium or lightweight aggregate block and download CAD However, in many cases, this is the only way to upgrade existing solid walled buildings, especially if they are in a architecturally sensitive area and external insulation would be inappropriate 454

Non-residential refurbishment: Walls 5.3.4 Introduction Internal insulation has long been a favourite method for improving the thermal performance of existing solid walls. Using plasterboard laminated to a thermal insulation board is a straightforward way of uprating the thermal insulation of walls. Thermal plasterboard laminate products are widely available and fixing of the system is straightforward and well understood. However, for many constructions laminated plasterboard solutions can struggle to achieve the increased thermal insulation standards required for refurbishment work necessitating the adoption of independent lining systems created from metal or timber frames. This section includes independent lining systems that achieve lower U-values than a standard laminated plasterboard. Avoiding thermal bridging When a wall is insulated internally, there are unavoidable thermal bridges at the junctions with internal partitions, separating walls and floors. At window and door openings, the insulation should always be returned into the reveal and the soffit, otherwise there is a high risk of condensation occurring on the uninsulated reveals. Where an independent steel framework is used as the lining, there should always be a continuous layer of insulation on one side of the steel frame to avoid severe thermal bridging through the steel members. Avoiding air infiltration Air infiltration behind an insulated lining, and through gaps and cracks in the wall behind, can significantly reduce the thermal performance of the wall. The design should incorporate an air barrier to reduce air leakage. This can be: A parging coat on the inside of the external wall Continuous ribbons of adhesive behind a rigid insulation backed plasterboard along the top and bottom of the wall, at internal and external corners and around all openings and service penetrations. A layer of plasterboard sealed at all junctions, with a flexible sealant used at the floor junction and around openings and service penetrations. A separate vapour control layer Avoiding condensation in the construction In order to minimise the risk of condensation forming on the cold internal surface of the external wall, it is essential to have a vapour control layer on the warm side of the insulation. In addition, the following detailing points will help to limit the amount of warm room air getting behind the insulation: Seal the joints at the junctions between the dry lining and surrounding walls and floors Keep the number of service penetrations to a minimum Seal around penetrations, such as waste pipes, with an expanding foam Dampness in existing walls Dry lining should not be used to isolate a dampness problem. Any dampness in an existing wall should be cured before internal insulation is installed. Existing solid walls may be temporarily suffering from damp following treatment for rising damp or after curing rain penetration problems or rectifying leaking gutters or downpipes. Polyfoam extruded polystyrene has a high moisture resistance and its thermal performance is unaffected by moisture, making it an ideal insulant for use on solid walls which may not be completely dry. Where doubts remain about the resistance of the wall to rain penetration, despite repointing or rendering, use an insulated independent lining. The independent lining should be at least 25mm clear of the existing masonry and the resulting cavity should be ventilated to the outside at high and low level. Particular care is needed to seal the insulated lining at the perimeter, at all service penetrations and around openings. design detail finder Knauf Insulation solutions for these types of construction can be found on ±pages 614-617 Alternative insulated dry linings Insulated plasterboard Independent lining External wall External wall Insulation backed plasterboard Minimum 25mm airspace Continuous ribbon of adhesive Insulated lining returned along internal walls, where practical, to minimise thermal bridging Steel stud frame infilled with insulation Insulation backed plasterboard minimises thermal bridging through steel frame Seal at perimeter of lining Insulated lining returned along internal walls, where practical, to minimise thermal bridging 455

6.2.6 Design details: Internal linings Internal linings Insulated dry lining Advantages Il01 3 Robust nature of Polyfoam in Linerboard supports plasterboard, improving its impact resistance 3 Moisture resistance of Polyfoam provides excellent solution for upgrading existing walls 3 Fixed with combination of plasterboard adhesive and mechanical fasteners External render Solid blockwork wall Polyfoam Linerboard Products Polyfoam Linerboard is a laminate of Polyfoam, 100% ozone friendly, extruded polystyrene, rigid board insulation and 9.5mm tapered edge plasterboard. Typical construction New or existing masonry solid walls, lined internally with Polyfoam Linerboard. Polyfoam Linerboards can be fixed with adhesive, plaster adhesive dabs or mechanically fixed. Where dabs or adhesive are used, secondary mechanical fixings are needed to secure the plasterboard in case of fire. Installation Before fitting the dry lining, the ceiling lining should be in place. The surface to be lined should be clean and dry with any wallpaper or loose plaster removed. If heavy fixtures, such as wash basins, are to be fixed to the wall, timber battens should be provided to accept the fixings. Holes for services should be cut before fixing the board. To accommodate services or obstructions on the wall, cut away the insulation to the depth of the obstruction. Boards can be either cut or sawn. When cutting the boards, use a sharp knife to cut through the insulation and score the plasterboard. The score is then snapped open to give a clean edge. Adhesive fixing Polyfoam Linerboard can be fixed directly with plaster or cement based adhesives. The adhesive is applied in vertical bands at the board edge and down the centre of the board. Continuous bands of adhesive should also be applied around openings, service penetrations and at the junctions with ceilings and floors. There should also be a continuous ribbon of plaster adhesive around the perimeter of each wall area. These measures are taken to minimise air infiltration Offer the board to the wall and adjust with a foot lifter as necessary. Insert packing strips at the base. Tap the board to align with pre-determined guidelines and adjacent boards. A neat and closed joint should be achieved at the wall/ceiling junction. Fill any gap at the base with proprietary bonding compound or sealant. When fixing Polyfoam Linerboard with adhesive, secondary mechanical fixings are required. Two fixings are recommended at the top of each board, 25mm in from the edge. The fixings should penetrate at least 35mm into a solid background. All PVC insulated electrical cables should be run in trunking or conduit behind the dry lining to avoid direct contact with the insulation. 614

Design details: Internal linings 6.2.6 Typical junction with ground floor Continuous ribbon of adhesive behind plasterboard and gap below Polyfoam Linerboard filled with flexible sealant to minimise air leakage Typical specification Polyfoam Linerboard of insulation thickness...mm with integral 9.5mm plasterboard to be fixed directly to the external walls by adhesive*/plaster adhesive dabs*/ mechanical fixing* using the method and materials recommended in Knauf Insulation literature. (*Delete as appropriate) When the adhesive has set, secure with two... (manufacturer/reference) mechanical fixings along the top edge of each board (for adhesive/dabs). Alternatively, refer to NBS clause: K10/185 Damp proof membrane Performance Thermal performance The insulation element of Polyfoam Linerboard has a thermal conductivity of 0.030 W/mK and the plasterboard has a thermal conductivity of 0.19 W/mK. Table 60 gives U-values for typical constructions. Fire performance Polyfoam Linerboard has an integral 9.5mm plasterboard which offers excellent fire performance. Polyfoam insulation contains a flame retardant to inhibit localised ignition. When installed on adhesive dabs, the secondary fixings at the top of each board will ensure the integrity of the application during evacuation in case of fire. Compression resistance The rigidity of the Polyfoam board behind the plasterboard will offer an excellent support to the finished internal lining and assist in the resistance of impact damage, helping to prolong its service life. Moisture resistance Walls should be sound and weatherproof before applying a thermal plasterboard laminate. When lining internal walls in refurbishment projects, the existing wall is often in a state of disrepair, which can lead to dampness in the wall. The Polyfoam insulation backing to the plasterboard is highly resistant to moisture absorption and can offer the best peace of mind solution for an application where any potential moisture ingress is a concern. If in any doubt about adhesive, use mechanical fixings. Table 60: Typical U-values for dry lined solid masonry walls U-values (W/m 2 K) for 215mm solid masonry wall of: Insulation thickness (mm) Dense block Medium block Lightweight aggregate Standard aircrete Lightweight aircrete Brick (λ=1.13) (λ= 0.51) (λ=0.34) (λ=0.16) (λ=0.11) (λ=0.77) 45.5/9.5 0.48 0.44 0.41 0.33 0.29 0.46 36/9.5 0.57 0.51 0.46 0.37 0.32 0.54 30.5/9.5 0.63 0.56 0.51 0.40 0.34 0.60 Note: The U-values have been calculated to BS EN ISO 6946: 1997 and BR 443 and assume a 19mm sand cement render external finish. For project specific calculations contact our Technical Advisory Centre on 01744 766666. 615

6.2.6 Design details: Internal linings Internal linings Independent lining Advantages Twin layer Earthwool DriTherm Cavity Slab 37 and Earthwool Flexible Slab Il02 3 Will not allow damp penetration 3 Non combustible insulation product 3 Keeps frame warm 3 Narrow system width Twin layer Earthwool Flexible Slab/ Polyfoam Linerboard 3 Linerboard prevents cold bridging 3 Robust nature of Polyfoam in Linerboard supports plasterboard, improving its impact resistance Timber studs with Earthwool Flexible Slab 3 Insulation friction fits between studs 3 Single layer insulation External render/cladding Masonry block/external wall Earthwool DriTherm Cavity Slab 37 or Earthwool DriTherm Cavity Slab in cavity Earthwool Flexible Slab between Knauf I studs Vapour control layer 12.5mm plasterboard Products Earthwool DriTherm Cavity Slab 37 is a semirigid slab of glass mineral wool with a water-repellent additive. Its manufacture has a very low impact on the environment and is classified as Zero ODP and Zero GWP*. Earthwool DriTherm Cavity Slab is a waterrepellent rock mineral wool slab. Its manufacture has a very low impact on the environment and is classified as Zero ODP and Zero GWP*. Earthwool Flexible Slab is a multi-purpose flexible, friction-fit, rock mineral wool slab. Its manufacture has a very low impact on the environment and is classified as Zero ODP and Zero GWP*. Polyfoam Linerboard is a laminate of Polyfoam, 100% ozone friendly, extruded polystyrene, rigid board insulation and 9.5mm tapered edge plasterboard. * Ecohomes and Code for Sustainable Homes classification Typical construction Masonry solid wall, with an independent internal lining, which can be: Knauf I studs, with twin layer insulation (as shown) Knauf I studs, infilled with Earthwool Flexible Slab and lined with Polyfoam Linerboard to reduce thermal bridging Timber studs infilled with Earthwool Flexible Slab An independent lining is ideal for existing solid walls that are out of true or new build solid masonry walls where a high level of thermal performance is required. Knauf I studs are available 50, 60, 70, 92 and 146mm deep. Installation Twin layer Earthwool DriTherm Cavity Slab 37 or Earthwool DriTherm Cavity Slab Construct the Knauf I stud independent lining 50mm from the internal face of the external wall. Space the studs at 600mm centres. Insert 50mm thick Earthwool DriTherm Cavity Slab 37 or Earthwool DriTherm Cavity Slab horizontally, in broken bond into the cavity between the steel frame and the external wall. Insert a layer of Earthwool Flexible Slab between the I studs of the metal frame. Fix a vapour control layer to the studs before screwing 12.5mm plasterboard to the metal frame and finish using standard drylining techniques. Where there is a need to install services in the outer wall, select a 70, or 92mm deep I stud and place 50mm thick Earthwool Flexible Slab to the back of the frame to provide a service void. Twin layer Earthwool Flexible Slab/Polyfoam Linerboard Construct the Knauf I stud independent lining at least 25mm from the internal face of the external wall. Space the studs at 600mm centres, insert Earthwool Flexible Slab between the studs. Screw fix Polyfoam Linerboard to the steel frame at maximum 150mm centres at least 12mm in from the board edge. Timber stud with Earthwool Flexible Slab: Construct a timber stud frame at least 25mm from the internal face of the external wall, with studs at 600mm centres. Insert Earthwool Flexible Slab between the timber studs. Fix a vapour control layer to the studs before fixing 12.5mm plasterboard in place and finish using standard drylining techniques. 616

Design details: Internal linings 6.2.6 Typical junction with ground floor Earthwool DriTherm Cavity Slab 37/Earthwool DriTherm Cavity Slab Earthwool Flexible Slab between Knauf I studs Plasterboard lining Flexible sealant at perimeter of steel frame and plasterboard to minimise air leakage Perimeter insulation with a thermal resistance of 0.75m 2 K/W Typical specification Construct a timber*/steel* stud framework... mm away from the internal face of the blockwork. a) Infill the gap between the steel frame and the block wall with Earthwool DriTherm Cavity Slab 37*/Earthwool* DriTherm Cavity Slab...mm thick, laid in broken bond. Earthwool Flexible Slab...mm thick to be friction fitted between the steel studs. b) The independent lining to be insulated with Earthwool Flexible Slab...mm thick. Insulation to be friction fitted between the studs. The wall panel to be lined internally with Polyfoam Linerboard of insulation thickness...mm with integral 9.5mm plasterboard screwed to the steel studs at 150mm centres. c) The independent lining to be insulated with Earthwool Flexible Slab...mm thick. Insulation to be cut as necessary and friction fitted between the timber studs. Alternatively, refer to BS clause: K10/145 or K10/155 Performance Table 61: Typical U-values for solid masonry walls with independent lining Thermal performance 50mm Earthwool DriTherm Cavity Slab has a thermal conductivity of 0.035 W/mK. 65mm and 75mm Earthwool DriTherm Cavity Slab have a thermal conductivity of 0.037 W/mK. Earthwool DriTherm Cavity Slab has a thermal conductivity of 0.037 W/mK. Earthwool Flexible Slab has a thermal conductivity of 0.035 or 0.037 W/mK. The insulation element of Polyfoam Linerboard has a thermal conductivity of 0.030 W/mK and the plasterboard has a thermal conductivity of 0.19 W/mK. Table 61 gives U-values for typical independent lining systems. Fire performance Earthwool DriTherm Cavity Slab 37, Earthwool DriTherm Cavity Slab and Earthwool Flexible Slab are classified as Euroclass A1 to BS EN ISO 13501-1. Insulation thickness (mm) U-values (W/m 2 K) for 215mm solid masonry wall of: Dense block Medium block Lightweight aggregate Standard aircrete Lightweight aircrete Polyfoam Linerboard consists of a 9.5mm plasterboard which offers excellent fire performance as a facing material and Polyfoam insulation which contains a flame retardant to inhibit localised ignition. Brick (λ=1.13) (λ= 0.51) (λ=0.34) (λ=0.16) (λ=0.11) (λ=0.77) Earthwool DriTherm Cavity Slab and Earthwool Flexible Slab (behind and between steel studs) 70+50 0.32 0.30 0.28 0.24 0.22 0.31 Earthwool Flexible Slab between steel studs and Polyfoam Linerboard (between and lining steel studs) 70+45.5/9.5 0.31 0.29 0.27 0.23 0.21 0.30 70+36/9.5 0.35 0.32 0.30 0.26 0.23 0.34 70+30.5/9.5 0.38 0.35 0.33 0.27 0.25 0.36 Earthwool Flexible Slab between 38mm wide timber studs (9% bridging) 140 0.26 0.24 0.23 0.20 0.19 0.25 100 0.37 0.33 0.32 0.27 0.24 0.36 Note: The U-values have been calculated to BS EN ISO 6946: 1997 and BR 443 and BRE Digest 465 (where appropriate) and assume a 19mm sand cement render external finish. Steel studs assumed to have 50mm wide flanges. All studs at 600mm centres. For project specific calculations contact our Technical Advisory Centre on 01744 766666. 617

Knauf Insulation Ltd PO Box 10 Stafford Road St Helens Merseyside WA10 3NS UK Tel: 01744 766 600 Fax: 01744 766 750 www.knaufinsulation.co.uk Ref: KB146110 June 2010 Knauf Insulation Ltd Customer Service (Sales) Technical Advisory Centre Literature PO Box 10 Tel: 0844 800 0135 Tel: 01744 766 666 Tel: 08700 668 660 Stafford Road Fax: 01744 612007 Fax: 01744 766 667 Fax: 0870 400 5797 St Helens Email: sales@knaufinsulation.com Email: tech@knaufinsulation.com Email: info@knaufinsulation.com Merseyside www.knaufinsulation.co.uk WA10 3NS