Current Standard Plates including Transmittal Letters are available on the web at:

Similar documents
TYPE "A" CATCH BASIN

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

Inlets & Catch Basins

AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MANHOLES, CATCH BASINS, DITCH INLETS AND VALVE CHAMBERS

(SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No.

This drawing. is preliminary. and not for. construction or. implementation. purposes. project number 170 END VIEW DESIGN STRENGTHS: PLAN

SECTION STORM DRAINAGE

CHAPTER 12: DRAINAGE

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

CITY OF SCHERTZ TEXAS ENGINEERING AND PUBLIC WORKS

Failure to acknowledge all addenda in the BID may cause rejection of the BID. See Instructions to Bidders.

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1

CHAPTER 12: DRAINAGE

UNIFORM STANDARD DRAWINGS CLARK COUNTY AREA, NEVADA YEAR 2015 REVISIONS

SUBJECT: Signal and Lighting Standard Plates , 8112, 8120, 8126, 8127, 8128, and 8134

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

ITEM 555 CHAIN LINK FENCING

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

SUPPLEMENTAL DRAWINGS

PERMANENT PAVEMENT REPAIR NO SCALE

FOR HISTORICAL REFERENCE ONLY

New Market Township. Driveway/Approach Permit

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF DESIGN

Section 403. DRAINAGE STRUCTURES

SECTION A-A NTS. Figure 4.1 Alternative Flow Dispersal Trench NOTES:

SECTION D2 MANHOLES AND CATCH BASINS GENERAL MATERIALS

Storm Drainage

APPENDIX C INLETS. The application and types of storm drainage inlets are presented in detail in this Appendix.

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

Drainage structure refers to manholes, catch basins, leaching basins, inlets and drop inlets. Drainage structures are designated as follows.

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

Testing. Test drainage products according to the applicable AASHTO or ASTM specification, except as otherwise noted.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

ONTARIO PROVINCIAL STANDARD SPECIFICATION

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

Section 401. PIPE CULVERTS

CHAPTER 11: WALLS.

Baseline Document Change Announcement

SANITARY MANHOLE S-1 ENGINEERING DEPARTMENT PLATE NUMBER NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL.

This type of masonry shall consist of brick laid in full beds of cement mortar.

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

FEBRUARY 2019 LRFD BRIDGE DESIGN 5-1

SECTION 39 - MANHOLES TABLE OF CONTENTS

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

FOR CRITICAL AREAS ADJACENT TO WETLANDS OR BELOW LONG AND/OR STEEP SLOPES, STEEL POSTS ARE NECESSARY AS INDICATED ON THE PLANS.

16. Design of Pipeline Structures.

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

MagnumStone Specifications Gravity

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

SECTION STORM SEWER PIPE

Electric Service Standards

PIPE CULVERTS. Construct pipe culverts, beveled ends, pipe aprons, and associated appurtenances.

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST

Appendix J: Storm Conveyance Design Parameters

SECTION CURB, COMBINATION CURB AND GUTTER, AND MONOLITHIC MEDIAN. 1. Bituminous concrete pavement; Section

The work required for this project includes, but is not limited to, the following items, not listed in order of execution.

SECTION 920 SANITARY AND STORM SEWER MANHOLES

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M


OHIO DEPARTMENT OF TRANSPORTATION CENTRAL OFFICE, 1980 W. BROAD ST., COLUMBUS, OHIO

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MAINTENANCE HOLES, CATCH BASINS, DITCH INLETS, AND VALVE CHAMBERS

B. Fiberglass for construction in back lot easements placed on cast-in-place base.

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

Miscellaneous and Cast Iron Listings

County of Sacramento Standard Construction Specifications January 1, 2008 TECHNICAL PROVISIONS

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LOW-TENSION CABLE BARRIER. OPR:CT 1 of 5 APPR:JAR:DBP: FHWA:APPR:

GENERAL NOTES ROADWAY CONSTRUCTION RD0001-1A ISSUED:2017 REVISED: --

1 Revised: 2019 Edition

Special Provision for LRFD Pipe Culvert Burial Tables

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

SECTION PRECAST CONCRETE MANHOLES

FLORIDA DEPARTMENT OF TRANSPORTATION

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

CLEARING & GRADING GENERAL NOTES CITY OF SCHERTZ TEXAS ENGINEERING AND PUBLIC WORKS SHEETNUMBER BCP PROJECT NO.: DATE: 11/1/18

Special Specification 6186 Intelligent Transportation System (ITS) Ground Box

Precast Concrete Trench Drain Systems INSTALLATION INSTRUCTIONS

D-1 THE CITY OF HARRISBURG 1 1/2" MIN. ID-2 WEARING COARSE EXISTING STREET SURFACE AC-20 SEALER (ALL AROUND) 1 1/2" MIN. ID-2 BINDER COARSE

Perma-Column Deck Post Design Manual

Department of Building and Zoning Approaches and Sidewalks for ONE AND TWO FAMILY CONSTRUCTION

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

Standard products Tasmania 2010

Highway Drainage 1- Storm Frequency and Runoff 1.1- Runoff Determination

SECTION UTILITY POLYETHYLENE CONTAINMENT PIPE SYSTEMS

35-46 KA KA

TECHNICAL SPECIFICATION

Qualified Product Policy 15 Drainage Structure Miscellaneous Components Qualified Product List 14 [G] Heavy Duty Gray Cast Iron

SECTION STORM DRAINAGE SYSTEM Excavating, Backfilling, and Compaction for Utilities Cast-in-place Concrete.

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

JANUARY 25, 2016 ADDENDUM NO. 3 FOR. ORD Baggage Service Road Retaining Wall Repair

MATERIAL SPECIFICATION FOR STEEL POLES, BASE MOUNTED

CHAPTER 3: DETAILS and ADA


1:100 GABION WALLS LEGEND NOT FOR CONSTRUCTION TYPICAL DRAWING TEXT SETTING TYPE CHARACTER HEIGHT PEN SETUP FOR PLOTTING SUBTITLE

Transcription:

MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (6-03) MANUAL: Standard Plates DATED: September 2, 206 SUBJECT: Standard Plates 407, 40, 440, 72, 8343 Minor revisions The following Standard Plates have been revised: 407C Catch Basin 40F Cover Casting for Manhole 440D Special Grate Castings for Catch Basin 72C - Installation & Reinforcement of Catch Basin & Manhole Castings 8343A - High-Tension Cable Barrier Line Post Foundation INSTRUCTIONS: Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual. The previous Transmittal Letter No. issued for this manual was 6-02, dated July 26, 206. Remove from the Standard Plate manual: Standard Plate 407C (Rev. 4-9-0), 408 back Standard Plate 40F (Appr. 0-25-96) Standard Plate 440D (Rev. 5-5-99), 443 back Standard Plate 72C (Rev. 3-22-3), 7 front Standard Plate 8343A (Appr. 8-9-5) Insert into the Standard Plate manual: Standard Plate 407C (Rev. 9-3-6) Standard Plate 408B (Appr. 4-6-4) Standard Plate 40F (Rev. 9-3-6) Standard Plate 440D (Rev. 9-3-6) Standard Plate 443E (Rev. 3-22-3) Standard Plate 7J (Rev. 3-22-3) Standard Plate 72C (Rev. 9-3-6) Standard Plate 8343A (Rev. 9-3-6) Current Standard Plates including Transmittal Letters are available on the web at: http://standardplates.dot.state.mn.us/stdplate.aspx Direct any technical questions regarding this transmittal to Ron Reemer, Design Standards Unit at (65) 366-4707. Michael Elle, P.E. Design Standards Engineer

THIS PAGE INTENTIONALLY LEFT BLANK

Summary of Changes Various Standard Plates Minor Revisions Transmittal Letter No. (6-03) 407C:. Circled note # (local note flag) was previously omitted from the notes (bottom right). 40F:. General note changed from Casting No. 700-7 to Casting No. 700-4. 440D:. General note changed from Casting No. 700-7 to Casting No. 700-4. 72C:. Removed last sentence of circled note 5. 8343A:. Added (Optional) to circled note 3.

THIS PAGE INTENTIONALLY LEFT BLANK

VIEW A-A :6 SLOPE DESIRABLE ROADWAY SHOULDER REINFORCED CONCRETE PIPE - CLASS II ( SEE STANDARD PLATE 3000 ) EARTH DITCH BLOCK 8'' MIN. 6'' A ( SOD SLOPES ) :6 8'' MIN. D A CONC. APRON FOR R.C.P. CIRCULAR OR PIPE-ARCH PAY HEIGHT ELEVATION REINFORCED CONCRETE PIPE DESIGN PC CONTINUOUS WELD VIEW B-B :6 SLOPE DESIRABLE ROADWAY SHOULDER EARTH DITCH BLOCK ( SOD SLOPES ) CORRUGATED METAL PIPE :6 8'' MIN. 6'' B 8'' MIN. NOTES: D INSIDE DIAMETER OF CATCH CIRCULAR OR PIPE-ARCH B PAY HEIGHT ELEVATION METAL APRON FOR C.M.P. BASIN WILL BE INDICATED IN THE PAY ITEM. FOR USE PRINCIPALLY FOR MEDIAN DRAINAGE. ANGLE WILL BE SHOWN IN PLAN FOR ARCH PIPE. CORRUGATED METAL PIPE DESIGN PM DESIGN PC DESIGN PM STATE OF MINNESOTA DEPARTMENT OF TRANSPORTATION CATCH BASIN CONCRETE PIPE AND METAL PIPE SPECIFICATION REFERENCE 2506 REVISED 9-3-206 M.J.E. STANDARD PLATE NO. 407C

THIS PAGE INTENTIONALLY LEFT BLANK

A A TOP VIEW TOP OF CASTING 4-/2 TYP. 48 DIA. 5 5-/2 FOR 60 DIA. 6 FOR 72 DIA. 2 4 5 FOR 60 DIA. 6 FOR 72 DIA. VARIABLE - 4 0 MAX. 3 5-/2 FOR 60 DIA. 8 FOR 72 DIA. 60 DIA. 72 DIA. 6 7 SECTION A-A NOTES: REINFORCING: SINGLE LINE STEEL WIRE FABRIC HAVING AN AREA OF NOT LESS THAN 0.5 SQ. IN. PER FOOT OF HEIGHT FOR 60 DIA. AND NOT LESS THAN 0.8 SQ. IN. PER FOOT OF HEIGHT FOR 72 DIA.. 2 3 REFER TO PLANS FOR ANY STEP REQUIREMENTS. SEE STANDARD PLATES INDEX FOR OTHER APPROVED JOINTS. MANHOLE REDUCING SECTION 4 0 HIGH. WALL THICKNESS TAPERS TO PROVIDE A SMOOTH EXTERIOR. 4 THE MAXIMUM DEPTH FROM THE TOP OF THE CASTING TO THE TOP OF THE REDUCING CONE IS 0-0". DESIGN D APPROVED APRIL 6, 204 STATE OF MINNESOTA DEPARTMENT OF TRANSPORTATION SPECIFICATION REFERENCE STANDARD PLATE MANHOLE OR CATCH BASIN NO. STATE DESIGN ENGINEER REDUCER CONE SECTION PRECAST 2506 408B

THIS PAGE INTENTIONALLY LEFT BLANK

MN/ 2'' MN/ -/4'' 3/8'' LIFT HOLE 7/8'' /4'' CROWN 3/8'' 4 4-5/32'' 2 /8'' RAD. TYP. THREE STACKING 7/8'' LUGS AT 20 APART /4'' RAD. TYP. CROWN 5 /8'' RAD. 2'' STACKING LUG STACKING LUG 7 VENT HOLES 5 -/4'' 3/8'' LIFT HOLE 3/8'' 4 3 4 3 4-5/32'' 4-5/32'' MAKE TREADS MAKE TREADS 3/6'' HIGH 3/6'' HIGH TOP VIEW BOTTOM VIEW TOP VIEW BOTTOM VIEW CASTING NO. 75 CASTING NO. 76 25-3/4'' 25-3/4'' -/4'' 3/4'' LIFT 4-5/32'' HOLE 4 -/4'' -/4'' -/4'' 7/8'' 2 /8'' RAD. TYP. THREE STACKING 7/8'' LUGS AT 20 APART 5 /8'' RAD. /4'' RAD. TYP. SECTION SECTION NOTES: THESE COVERS TO BE USED WITH RING CASTING NO. 700-4 TO 700-0. ON OPPOSITE SIDE OF TOP SURFACE PLACE CASTING NUMBER, LETTERS ( MN/DOT ) AND NUMERALS TO BE 3/4'' IN HEIGHT AND DEPRESSED /8''. 2 LIFT HOLE MACHINE FINISHED THICKNESS TO BE 3/6''. 3 COVER SHALL BE MADE OF GRAY IRON. CLASS 35B. 4 LIFT HOLE -/4'' DIA. AT THE TOP, -/2'' AT THE BOTTOM. 5 EIGHT (8) VENT HOLES IN OUTER CIRCLE. NINE (9) VENT HOLES IN INNER CIRCLE. HOLES ARE 3/4'' DIA. AT THE TOP AND '' DIA. AT THE BOTTOM. INNER CIRCLE IS 2'' FROM THE OUTER CIRCLE. /4'' CASTING NO. 75-5 LBS. CASTING NO. 76-8 LBS. APPROVED OCTOBER 25, 996 STATE OF MINNESOTA DEPARTMENT OF TRANSPORTATION SPECIFICATION REFERENCE STANDARD PLATE STATE DESIGN ENGINEER COVER CASTING FOR MANHOLE ( FOR USE IN ALL TRAFFIC AREAS ) 2506 REVISED 9-3-206 M.J.E. NO. 40F

THIS PAGE INTENTIONALLY LEFT BLANK

720 72 MN/DOT MN/DOT 2'' 2'' A A A A -/4'' -/4'' TOP VIEW CASTING NO. 72 TOP VIEW CASTING NO. 720 2' -3/4'' DIA. 2' -3/4'' DIA. 7/8'' FINISHED THICKNESS 9 SPACES AT 2-/8'' = ' 7-/8'' 9 SPACES AT 2-/8'' = ' 7-/8'' '' 5/8'' 3/6'' '' 2'' '' 3/6'' 5/8'' R. 3/6'' 2'' MACHINE FINISHED 5/8'' /2'' 7/8'' FINISHED THICKNESS MACHINE FINISHED 5/8'' /2'' 3/6'' 5/8'' R. 2' -5/8'' DIA. 2' -5/8'' DIA. SECTION A-A CONCAVE SECTION A-A CONVEX NOTES: THESE GRATES SHALL BE USED WITH RING CASTING NO. 700-4 TO 700-0. LETTERS ( MN/DOT ) AND NUMERALS ( 720 & 72 ) SHALL BE 3/4 INCHES IN HEIGHT AND DEPRESSED /8 INCHES. CASTING NO. 720 CASTING NO. 72 STATE OF MINNESOTA DEPARTMENT OF TRANSPORTATION SPECIAL GRATE CASTINGS FOR CATCH BASIN CONVEX AND CONCAVE SPECIFICATION REFERENCE 2506 REVISED 9-3-206 M.J.E. STANDARD PLATE NO. 440D

THIS PAGE INTENTIONALLY LEFT BLANK

F303 CIRCULAR REINFORCE~ENT BAR, APPROX. 3' 2" DIA. F30 C TYP.l 3/4" LETTERS DEPRESSED /8" a: >- - B L B _j a: >- - TOP VIEW TOP VIEW 3'6" 4-/4" 4-3/4" ri do: : > NI- 2'0" 2'9" ' " -- -- 'N ~ ~ lcj L:Jf :< N '! ;........ ' I ll'l + ' goo.. " SECTION A-A EIGHT F30 BARS CSEE DETAIL! EQUALLY SPACED SECTION B-B STOOL TYPE GRATE C CASTING NO. 73 l APPROX. WEIGHT 200 LBS. REINFORCED CONCRETE FRAUE C FOR CASTING NO. 73 l ~~~s ~ F30 NOTES: FRA~E MAY BE PRECAST OR CAST-IN-PLACE. CASTING NO. 73 & FRAME APPROVED MARCH 4, 996 STATE OF MINNESOTA DEPARTMENT OF TRANSPORTATION ~JUJ)j~~ STOOL GRATE & CONCRETE FRAME SPECIFICATION REFERENCE STATE DESIGN ENGINEER ( MEDIAN DRAINS l REVISED 3-22-203 ~.J.E. 2506 STANDARD PLATE NO. 443E

THIS PAGE INTENTIONALLY LEFT BLANK

2'0" GUTTER WIDTH ' 0" -FLOW - FLOW DEPRESSION ( SUMP ) IN FLOW LINE AT CATCH BASIN LOCATION DISTANCE FROM It SHOWN IN PLANS 3" ;5 ::IIi. = 5 ""<.J 3" MIN. CLR. DESIGN D CONCRETE CURB & GUTTER DISTANCE FROM It TO FACE OF CURB SHOWN IN PLANS 2' 0" GUTTER WIDTH W A CURB DESIGN B CONCRETE CURB & GUTTER CURB BOX CASTINGS USED FOR ASSEMBLY 82B, 823A, 824, 83A & 833A DISTANCE FROM It TO FACE OF CURB SHOWN IN PLANS DISTANCE FROM It SHOWN IN PLANS 2'0" DESIGN B CONCRETE CURB A CURB WIDTH ONE NO. 4 X 5'LONG ~--fi;..t--{5 BAR PLACED THROUGH LUG HOLES, NOTES: COMPENSATE FOR TILT BY VARYING THE DEPTH OF MORTAR SEAT. DETAILS ARE TYPICAL AND APPLY TO INSTALLATION OF BOTH TELESCOPING AND NON-TELESCOPING CASTINGS. REFER TO PLANS FOR SPECIFIC ITEMS REQUIRED. ALL REINFORCEMENT REQUIRED IS INCIDENTAL, WITH NO DIRECT PAYMENT. CD CATCH BASIN CASTING. @ON ALL APPLICATIONS USE.0' SUMP. SUMP SHALL BE MEASURED AT CENTER OF CASTING. @SAME THICKNESS AS ADJACENT PAVEMENT OR GUTTER. @THREE NO. 4 HORIZONTAL BARS 5' 0" LONG CENTERED ABOUT It OF CASTING. @ CURB INLET CASTING SHALL BE FASTENED TEMPORARILY TO FRAME CASTING WITH 2 CAP SCREWS, DURING CURB CONSTRUCTION. CAP SCREWS MUST BE REMOVED AFTER CURB HAS HARDENED. APPROVED APRIL 23, 996 STATE OF MINNESOTA DEPARTMENT OF TRANSPORTATION ~JUJ)J.I(~ STATE DESIGN ENGINEER INSTALLATION OF CATCH BASIN CASTINGS CONCRETE CURB & GUTTER SPECIFICATION REFERENCE 253 REVISED 3-22-203 M.J.E. STANDARD PLATE NO. 7J

THIS PAGE INTENTIONALLY LEFT BLANK

FLOW 3' 0'' 3' 0'' 2 FLOW 45 TYP. 4'' BACK OF CURB 45 TYP. 4'' BACK OF CURB TOP OF CURB 3 CATCH BASIN LOW POINT LOCATION DEPRESSION ( SUMP ) IN FLOW LINE AT CATCH BASIN LOCATION A 4'' A B 4'' B CATCH BASIN CATCH BASIN LONGITUDINAL JOINT TWO NO. 5 BARS, 6' LONG 4'' 4'' 2-NO. 4 5 -NO. 4 -/2'' CLR. -NO. 4 -/2'' CLR. CONTRACTION JOINT CATCH 5 5 BASIN OR MANHOLE 5 KEYWAY TWO NO. 5 BARS 6' LONG DESIGN B, S OR V CURB DESIGN D CURB KEYWAY PLAN VIEW CATCH BASIN WITH DESIGN B, S OR V CURB PLAN VIEW CATCH BASIN WITH DESIGN D CURB TWO NO. 5 BARS, 6' LONG PLAN VIEW ( MANHOLES ) DISTANCE FROM < TO FACE DISTANCE FROM < OF CURB SHOWN IN PLANS A CURB WIDTH SHOWN IN PLANS < CASTING CLR. 3' MIN. 2' 0'' 2' 0'' ' 0'' 5'' 4'' 2 ONE NO. 4 X 5' 0'' LONG BAR SHALL 5'' 4'' 2 BE PLACED THROUGH CORED HOLES IN LUGS. 4 DISTANCE FROM < SHOWN IN PLANS SECTION A-A < STRUCTURE DESIGN B CURB SHOWN THREE NO. 4 HORIZ. BARS 5' 0'' LONG CENTERED ABOUT < OF CASTING SECTION B-B DESIGN D CURB SHOWN 3'' 3' MIN. CLR. 3'' MIN. CLR. CURB DESIGN CURB BOX CASTING B, S & V 82B, 822 & 83A B & V 823A & 833A B 824 & 825 ADDITIONAL SLAB REINF. - TWO NO. 5 BARS 6' 0'' LONG, SPACED AT 5'' CENTERS. PLACE DIRECTLY BELOW TYPICAL SLAB REINF. AT LOCATIONS SHOWN. NOTES: COMPENSATE FOR TILT BY VARYING THE DEPTH OF MORTAR SEAT. DETAILS ARE TYPICAL AND APPLY TO INSTALLATION OF BOTH TELESCOPING AND NON-TELESCOPING CASTINGS. REFER TO PLANS FOR SPECIFIC ITEMS REQUIRED. REINFORCEMENT BARS SHALL BE GRADE 60. ALL REINFORCEMENT REQUIRED IS INCIDENTAL, WITH NO DIRECT PAYMENT. 2 ON ALL APPLICATIONS USE.0' SUMP. SUMP SHALL BE MEASURED AT CENTER OF CASTING. 3 SAME THICKNESS AS ADJACENT PAVEMENT OR GUTTER. 4 CURB INLET CASTING TO BE FASTENED TEMPORARILY TO FRAME CASTING WITH 2 CAP SCREWS, DURING CURB CONSTRUCTION. CAP SCREWS MUST BE REMOVED AFTER CURB HAS HARDENED. 5 WHEN PAVEMENT JOINTS ARE WITHIN 0'' OF CATCH BASIN OR MANHOLE, BOX IN OPENING WITH KEYWAY JOINT. APPROVED APRIL 23, 996 STATE OF MINNESOTA DEPARTMENT OF TRANSPORTATION SPECIFICATION REFERENCE STANDARD PLATE INSTALLATION & REINFORCEMENT OF 253 NO. STATE DESIGN ENGINEER CATCH BASIN & MANHOLE CASTINGS CONCRETE INTEGRANT CURBS REVISED 9-3-206 M.J.E. 72C

THIS PAGE INTENTIONALLY LEFT BLANK

o DESIGN DATA 2" MIN. COMPLY WITH AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 7TH EDITION, WITH 205 INTERIMS. DESIGN FORCE: MAX PLASTIC MOMENT = 9000 ft-lb GAUGE (0.25") THICKNESS MINIMUM MATERIAL DESIGN PROPERTIES: STRUCTURAL STEEL: Fy = 36000 p.s.i. STRUCTURAL STEEL MnDOT 3306 /8 /8 3-6 3-6 MINIMUM SOIL PROPERTIES: COARSE GRAINED SOIL: = 30 FINE GRAINED SOIL: C = 000 lb/sq.ft. DRIVEN SOCKET PER MANUFACTURER'S SPECIFICATIONS GALVANIZE ALL STEEL COMPONENTS AFTER FABRICATION PER MNDOT SPEC. 3392 AND 3394. TRAFFIC PLAN VIEW 2 POST STOP METHOD PER MANUFACTURER. DEPTH AS PER MANUFACTURER'S SPECIFICATIONS BASED ON THE SOCKET DEPTH SET UP IN THE FHWA APPROVED CRASH TESTED HTCB SYSTEMS MEETING NCHRP 350 OR MASH REQUIREMENTS. 3 4 THREE (OPTIONAL) 7/8" DIAMETER VENT HOLES FOR GALVANIZING. UPPER HOLE MAY ALSO BE USED FOR POST STOP IF APPLICABLE. DRIVEN SOCKET DEPTH MUST MEET SPECIFIED DEPTH REGARDLESS OF SHALLOWER CRASH TESTED DEPTHS. LINE POST FOR CABLE BARRIER SYSTEM V:4H MAX. 3" TO 6" 3" TO 6" 2 '-2"MIN. (OPTIONAL) 7/8" VENT HOLES (TYP) 3 4 6'-0" 5'-0" MIN. 6-/2" 6-/2" 0-/2" DRIVEN SOCKET PER MANUFACTURER'S SPECIFICATIONS SOIL PLATE SOIL PLATE GAUGE (0.25") THICKNESS MINIMUM ELEVATION VIEW SIDE VIEW APPROVED AUGUST 9, 205 STATE DESIGN ENGINEER STATE OF MINNESOTA SPECIFICATION DEPARTMENT OF TRANSPORTATION REFERENCE HIGH-TENSION CABLE BARRIER 2554 LINE POST FOUNDATION REVISED STEEL DESIGN 9-3-206 M.J.E. STANDARD PLATE NO. 8343A