MD Power Supply -48Vdc +Bias Tee

Similar documents
MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Carbon Canister Vapor Polisher

MANUAL ENGLISH. Ordercode: D3423/D3423W. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

92831 TEL: (714) FAX:

ENGLISH Compact Half Coupler 50 mm, SWL: 50 kg

TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

Thermoelectric Cooler

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

Installation and Operation Manual

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

DJ Switch 10F V2 ORDERCODE 50365

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Global Water globalw.com. Global Water. Instrumentation, Inc.

ENGLISH WiFi Module for GIG-202 Tab

Calibrate Accessory Actuators Instructions

Operation & Service Manual

Glide-Line Heavy Duty Lift Locate Unit (HLLU)

Symmetra PX kw 208 V. Receiving and Unpacking 08/2015.

DUST FREE ACTIVE Total Home Air Purification

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Festoon Manual Heavy Duty C-Track

MICRO-INVERTER PIGRID W MICRO GRID TIED INVERTER 208, 220, 230, 240VAC

Table of contents. 1. Introduction

Installation Manual. Omnicell. Model: 9101 FB by Fairbanks Scales, Inc. Revision 2 03/16 All rights reserved

Owner's Manual 3,600 Pound Keeperless Cargo Hook Kit. Eurocopter AS350B3

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

INSTALLATION AND OPERATION MANUAL

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

RJE INTERNATIONAL, INC. U LB-364EL R EV 3.2

CM-95 ORDERCODE D1355 Highlite International B.V.

FTW 175 Wireless Monitoring System Reference Manual Part Number

INSTALLATION INSTRUCTION IM 317 E

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

4-Wire Buffer Amplifier. User Manual

Maintenance Service. 1.0 Executive Summary 1.1 ANNUAL PREVENTIVE MAINTENANCE VISIT 1.2 ON-SITE REMEDIAL SERVICES

Agilent Technologies 7620-AS Sample Changer Site Preparation Checklist Hardware Site Preparation Specification

Agilent 16034E Test Fixture

! CAUTION: Read and follow these instructions.

Owner s Manual & Safety Instructions

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Installation Manual. Omnicell. Model: 9102 FB by Fairbanks Scales, Inc. Revision 4 08/16 All rights reserved

Agilent 16048D Test Leads

EPS Receiving and Unpacking 06/

Global Water Instrumentation, Inc.

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

OPERATION AND INSTALLATION MANUAL

TallSlateTM Grandee Installation Manual

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

SENTRAN. For more information call

Agilent 1220 Infinity LC Mobile Upgrade Kit

OptoLum MegaLine RGBW Luminaire

Glide-Line Standard Lift Locate Unit (SLLU)

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

Power Distribution Module Replacement Instructions

SENTRAN. Low Profile Load Cell. For more information call

Precision Automatic Vacuum Control (PAVC+)

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

KRIWAN Wind Sensors. Operating Instructions Accessories and Application Information

To Contact PS DOORS:

Dynatronics Parallel Bars

Zehnder Carboline Radiant Heating and Cooling Ceiling Panels. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air

Agilent Technologies 11752D/E Option K01 Connector Gage Kit. User s Guide

Global Water Instrumentation, Inc.

TeraFrame HD Cabinet System Supplemental Installation Guide

1501 Incubator for Ampoule Biological Indicators

RJE INTERNATIONAL, INC.

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Galaxy VX. Receiving and Unpacking 04/

COOPER POWER SERIES. 200 A 15 KV, 25 KV and 35 KV class insulated protective cap installation instructions. Loadbreak Apparatus Connectors MN650035EN

Bravo Platform Unpacking Guide

INSTALLATION INSTRUCTIONS FOR. MODEL MSBULTB LED

Installation. Basic Rack Power Distribution Units AP9560 AP9561

Installation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors.

SENTRAN. Low Profile Load Cell. For more information call

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Advantage Ultra Plan for UPS/PDU with RMS

Operating Instructions. Supplementary electronics. For 4 20 ma/hart four-wire. Document ID: 42766

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

92831 TEL: (714) FAX:

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

USER'S GUIDE TO OPERATION

Model # 600H-D. 4/2/2012 Page 1 of 6

Model # 612H. 7/11/2016 Page 1 of 6

RUBBER BANDS 500 USER'S MANUAL. IGS Audio Igor Sobczyk 3 Maja 76d, Mysłowice, Poland ph:

RJE INTERNATIONAL, INC. STI- 350 R EV 2.2

KNHE20 SERIES WATER-TO-AIR HEAT EXCHANGER

Customer Guidelines for AMD Microprocessor Returns. May 28 th

Agilent 16047D Test Fixture

SENTRAN. Low Profile Load Cell. For more information call

PERFORMANCE SPECIFICATION SHEET

SENTRAN. Low Profile Load Cell. For more information call

Owner s Manual & Safety Instructions

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

Transcription:

215988-001MD Power Supply -48Vdc +Bias Tee Operation and Maintenance Manual

Mitec Telecom Inc. Designers and manufacturers of telecom and wireless products 9000 Trans Canada, Pointe-Claire, Quebec, Canada H9R 5Z8 OPERATION AND MAINTENANCE MANUAL Preliminary Released REVISION RECORD Revision ECN # Description Date Approved 0 Engineering Release. Dec 17, 08 CM Approval TITLE: 215988-001MD Power Supply -48Vdc +Bias Tee This document contains information proprietary to mitec telecom inc., or its affiliates, or to a third party to which mitec telecom inc. may have a legal obligation to protect such information from unauthorized disclosure, use, or duplication. Any disclosure, use, or duplication of this document or of any of the information contained herein is expressly prohibited except as mitec telecom inc. may otherwise agree in writing. Designer: Normand Roy Date: 17 Dec, 08 Technical Writer: Ravinder Date: 17 Dec, 08 REV 0 DOCUMENT NO. 215988-001MA PAGE 1 OF 25

mitec Table of Contents Table of Contents 1 INTRODUCTION... 3 1.1 Receiving and Inspection...3 1.1.1 Equipment Damage or Loss...3 1.1.2 Return of Equipment...4 1.2 Preparing for Installation...4 1.2.1 Safety Precautions...4 2 INSTALLATION & OVERVIEW... 5 2.1 General Description...5 2.2 Specifications...5 2.2.1 General Considerations...6 2.3 Basic Mechanical Characteristics...6 2.3.1 External View of the Module...6 2.3.2 Connections and Mounting Hardware...6 2.4 Assembly and Installation...7 2.4.1 Lifting the Module into Position and Temporary Attachment...7 2.4.2 Securing the Module...7 2.5 Functional Overview...8 2.5.1 General...8 3 OPERATION... 9 3.1 Procedure...9 3.2 Connector Interface...9 4 MAINTENANCE... 11 4.1 Preventive Maintenance...11 4.1.1 Procedure...11 4.1.2 PSU Module System Preventive Maintenance...11 4.1.3 Performance Check...11 Rev 0 i

Table of Contents mitec 4.1.4 Troubleshooting...12 4.1.5 Out-of Warranty Repair...12 APPENDIX A...1 Drawings & Schematic Diagrams...1 APPENDIX B...1 Spare Parts...1 List of Tables Table 1 Specifications...5 Table 2 - Recommended Corrective Actions...12 List of Figures Figure 1 - Module Block Diagram...8 Figure 3-215988-001MD - Power Supply -48Vdc + Bias Tee - Outline Drawing...1 ii Rev 0

mitec Preface Preface Scope This document covers the installation, operation, and maintenance of the 215988-001MD Power Supply -48Vdc +Bias Tee. It contains information intended for engineers, technicians and operators working with the transmitter module. To make inquiries, or to report errors of fact or omission in this document, please contact the technical writing department at Mitec Telecom Inc. at (514) 694-9000. IMPORTANT Important information concerning the operation and care of this product, as well as safety of authorized operators is highlighted throughout this document by one of the following labels: NOTE Indicates a reminder, a special consideration, or additional information that is important to know. CAUTION! Identifies situations that have the potential to cause equipment damage. WARNING!! Identifies hazardous situations that have the potential to cause equipment damage as well as serious personal injury. Rev 0 P-1

mitec Introduction 1 Introduction The Power Supply -48Vdc +Bias Tee module is a highly reliable, high quality, cost efficient 48V isolation system designed for use in VSAT applications. This line of superior products, engineered using state of the art technology, is characterized by unparalleled durability and dependability. Refer to Table 1 for specification. 1.1 Receiving and Inspection The Power Supply module is designed to function outdoors and will arrive in standard shipping containers. Immediately upon receipt of the Power Supply module, check the Bill of Lading against the actual equipment you have received. Inspect the shipping containers exteriors for visible damage incurred during shipping. CAUTION! Handle the transmitter module with extreme care. Excessive shock may damage transmitter module s delicate internal components. NOTE Before unpacking the shipping containers, move them near to the site where the system will be mounted. Ensure that the containers are oriented correctly in accordance with the This Side UP labels. Carefully remove the transmitter module and packing material from the shipping containers. Using the supplied packing list, verify that all items have been received and undamaged during shipment. Verify that all items are complete. If there are any omissions or evidence of improper packaging, please notify mitec telecom inc. immediately. 1.1.1 Equipment Damage or Loss Mitec Telecom Inc. is not responsible for damage or loss of equipment during transit. For further information, contact the responsible transport carrier. When declaring equipment as damaged during transit, preserve the original shipping cartons to facilitate inspection reporting. Rev 0 Page 3

Introduction mitec 1.1.2 Return of Equipment When returning equipment to mitec for repair or replacement: 1. Identify, in writing, the condition of the equipment, 2. Refer to the sales order, Purchase Order and the date the equipment was received. Notify Mitec Sales Administration Department of the equipment condition and obtain a Return Material Authorization (RMA) number and shipping instructions. Mitec will pay for the cost of shipping the product to the customer after the repairs are completed. NOTE 1.2 Preparing for Installation Do not return any equipment without an RMA number. This is important for prompt, efficient handling of the returned equipment and of the associated complaint. Before attempting to install or use the Power Supply module, we recommend that you first familiarize yourself with the product by reading through this manual. Understanding the operation of the system will reduce the possibility of incorrect installation, thereby causing damage or injury to yourself or others. The transmitter module must be installed in accordance with the conditions and recommendations contained in the following sections. When you are ready to begin your installation, use the information in Chapter 2 (Installation) as a guide for making all the required electrical connections. 1.2.1 Safety Precautions Carelessness or mishandling of the transmitter module may damage the unit causing serious injury to yourself or others. Please adhere to the following: Page 4 Rev 3

mitec Installation & Overview 2 Installation & Overview 2.1 General Description This section describes the installation and theory of operation of the 48V isolation module. The module is a stand-alone Power Supply + Bias Tee System when powered from a -32 to -50 VDC power source. The module consists of a -48Vdc isolation power supply and a bias tee. The power supply provides the +DC voltages to the RF amplifier via the IF connector on the bias tee. The module is capable of providing an output of +48Vdc at 8 amp. The module is for outdoor use and is secured onto a mounting boom mount mounting bracket. Four inch U bolt are supplied. 2.2 Specifications Table 1 summarizes the specifications of the Power Supply -48Vdc +Bias Tee. For mechanical specifications, refer to the outline drawing in Appendix A. Table 1 below lists the specifications. Table 1 Specifications Performance IF Input Port DC IF Output Port DC IF Port Frequency Range Insertion Loss IF input to IF output Input Return Loss both ports DC Input Power Requirement DC Blocked +32 to +50VDC @ 8 Amp 10MHz, 950 to 1825 MHz -1 db nom. -12 db max 40 VDC to 50 VDC, 430W typ. Rev 0 Page 5

Installation & Overview mitec Mechanical Specifications Input Interface Output Interface Package Size (overall dimensions Weight N-type, female (50 ohm) N-type, female (50 ohm) Outdoor, weather resistant 8.0500" x 5.3550" x 3.345" (204.47mm x 136.017mm x 84.899mm) 10 lbs (4.535 kg) Environmental Operational Storage Temperature Range -40 to +55 C -40 C to +75 C Humidity 0 to 100% Altitude 15,000 ft AMSL NOTE Technical specifications are subject to change without notice. 2.2.1 General Considerations The module shall meet all specifications over full bandwidth and under all environmental conditions. 2.3 Basic Mechanical Characteristics 2.3.1 External View of the Module The physical external dimensions of the transmitter module are shown in the outline drawing in Appendix A and Table 1. All inputs and outputs are shown in the outline drawing 2.3.2 Connections and Mounting Hardware The connections require a coaxial cable with an N-type male connector for the IF Input and output. A DC input connection using a MS3106E20-15P type connector. The PSU is mounted using the 2 U bolt supplied with the unit. Page 6 Rev 3

3 inches min. mitec Installation & Overview 2.4 Assembly and Installation Use the information in this section as a guide to assemble and install the transmitter module. CAUTION! Only authorized technical personnel should perform the Installation and proper electrical hookups of the transmitter module. 2.4.1 Lifting the Module into Position and Temporary Attachment The module weighs approximately 10lbs, which may be handled by a single person. Remove all plastic caps from the connectors. The module is now ready for permanent attachment. 2.4.2 Securing the Module Secure the Power Supply module on to the boom or the mass using the hardware described in section 2.3.2. Attach the proper cable for IF input and IF output to the corresponding connector of the modem and BUC. Refer to the figure 2 system bloc diagram. NOTE The connectors are labeled clearly and has different pin layout. Refer to the outline drawing in Appendix A. It is impossible to incorrectly install the mating connectors. The Power Supply module requires a steady flow of air. To provide a sufficient airflow, the Power Supply module shall be properly oriented, with the deepest heat sink fins facing up, and mounted with a minimum clearance of 3.0 inches on all sides of the Power Supply module. Adequate cooling for the Power Supply module will provide years of top performance. 3 inches min. IF IN F-Type WR75 Output 3 inches min. Rev 0 3 inches min. Page 7

POWERSOURCEtomwiraslameingshrgnooedenwcudtthnhreoeetiubweslerdpre&EF&G-Vd+Vd.Installation & Overview mitec 2.5 Functional Overview 2.5.1 General This section describes the module functions in detail. The functional overview explains the power distribution. Figure 1 block diagram illustrates the module. +Vdc, 10MHz, IF DC in 48Vdc IsolationModule +Vdc Bias Tee 10MHz, IF Figure 1 - Module Block Diagram POWER SUPPLY - + -48Vdc Duerecotheline+Vdc ntoo16awg 16AWG 16AWG 16AWG J3 MS3106E20-15S A B C D E F G cdmodem IF OUT axif / 10MHz CableBUC Bias T IF IN J1 ccoaxcableif / 10MHz and +48Vdc CoJ2: IF OUTPUT J1: IF INPUT Figure 2 - System Block Diagram Page 8 Rev 3

mitec Operation 3 Operation This chapter describes the verification of the operation of the Power Supply module. It shall be performed by authorized personnel prior to maintenance and/or repair. 3.1 Procedure Verify that the installation procedure described in Chapter 2 was completed. A complete physical check of the customer s system is suggested. Turn ON the power and allow a warm up period before operating the transmitter module. This will assure stable gain and power. 3.2 Connector Interface Connector Name J1 IF IN J2 IF OUT J3 DC INPUT Type Pin # Signal Name Description Parameter N-Type Female N/A IF Input IF Input N-Type Female IF Output IF Output MS3102R20-15P D E F G -Vdc See Note 1 +Vdc See note 1 16 AWG max 16 AWG max 10MHz, 950 to 1825 MHz 10MHz, 950 to 1825 MHz With +VDC 32 to 50Vdc 430W nom Note 1: For Negative DC operation connect the Vdc to the source (-) and the +Vdc to the source (+) or GND. For Positive DC operation connect the +Vdc to the source (+) and the -Vdc to the source (-) or GND. Rev 0 Page 9

mitec Maintenance 4 Maintenance This chapter contains information on how to maintain and troubleshoot the Power Supply module. The Power Supply module is extremely reliable, requiring very little preventive maintenance, or repair. Should there be a malfunction, this chapter also contains technical information to help diagnose basic failures. 4.1 Preventive Maintenance 4.1.1 Procedure WARNING! Shut down the module before disassembly and remove all cables and connections. Failure to observe this precaution may result in personal injury or death. This includes the removal of any RF power originating from other system components. 4.1.2 PSU Module System Preventive Maintenance Preventive maintenance is limited to checking the performance of the Power Supply module. No electrical or mechanical adjustments are required for normal operation. Periodic cleaning of the heat sink fins will ensure adequate ambient cooling. 4.1.3 Performance Check Verify the system is properly set up as per Chapters 2 and 3. It is recommended to measure the following parameters for ensuring that the Power Supply module is in good working condition: - Insertion Loss IF input - Input and output Return Loss - Presence of +48Vdc on the IF output center pin. Rev 0 Page 11

Maintenance mitec 4.1.4 Troubleshooting WARNING!! Cable connection and disconnection shall be done carefully to avoid physical damage to the cables and connectors, which may cause intermittent problems in the future. Use Table 2 to quickly isolate a fault within the Power Supply module. If the Power Supply module is defective, notify mitec and follow the process detailed in section 1.1.2. Symptom Fails performance test Action Check power source, IF source, 10 MHz source, cabling and connectors. Check for debris in heat sink fins. Clean thoroughly. return to mitec. Table 2 - Recommended Corrective Actions 4.1.5 Out-of Warranty Repair A non-warranty and out-of-warranty repair service is available from mitec for a nominal charge. The customer is responsible for paying the cost of shipping the module both to and from mitec for these repairs. Page 12 Rev 3

mitec Appendix A Appendix A Drawings & Schematic Diagrams 215988-001MD - Power Supply -48Vdc + Bias Tee - Outline Drawings Rev 3 A - 1

mitec Appendix A Figure 3-215988-001MD - Power Supply -48Vdc + Bias Tee - Outline Drawing