Non Residential Commissioning:

Similar documents
Design-Phase Commissioning. Glenn Hansen, P.E., Senior Engineer PECI

SLO GB Alliance. Title 24 Non Res Certification Process. Wed, Oct 1, Rick Miller, PE, LC, LEED AP, CLCATT President, RNM Engineering, Inc.

2013 Nonresidential Energy Standards Overview

Decoding Attics and Walls

PLATINUM LEVEL SPONSOR GOLD LEVEL SPONSORS GREEN LEVEL SPONSOR

ICTA 2015: Cinema Design & Construction Compliance with the New Energy Code

ICC 1000 APPLICATION OF THE COMMISSIONING PROCESS. March 27, Proposed Revision: GJKettler May 11, 2014

2013 Title 24, Part 6 Residential HVAC April 11, Gina Rodda Gabel Associates, LLC

Attachment 04 Substantial and Final Completion Approval Form. Project Description Project # Date of Completion Permit # Project Manager Phone #

Commissioning at NYP. Joseph Lorino, PE, LEED Vice President, Facilities Management November 4, 2015

COMMISSIONING PROCESS FOR BUILDINGS AND SYSTEMS ASHRAE STANDARD 202

2019 Title 24 Codes & Standards Enhancement (CASE) Proposal High Performance Walls

Draft Policy for Commissioning/ Retro-Commissioning

Building Codes for Energy Efficiency and Cx. Randall Higa Codes and Standards Program Manager Southern California Edison

Codes, Standards & Guidelines, Oh My! Michael Chelednik, AIA Sr. Airport Terminal Architect URS

Pay for Performance - NC Technical Topic

Lori A. Brown, LEED AP BD+C, LEED AP ND, LEED AP O+M -- LEED Green Associate Exam -- Power Jam Study! -- lorisweb.com 1

CALGreen & Commissioning: Challenges & Opportunities

Building Energy Efficiency Standards

LEED BD+C: NC, CS, S, R, DC, WDC, HOS, HC

Building Commissioning

and LEED Energy and Atmosphere Credits Jean Ascoli, LEED AP BD+C Architect, Energy Specialist

Session Goals Updates to CALGreen 2016 Intervening Code Adoption Cycle Additional Resources

Green Building Consulting and Verification. Energy Efficiency Optimization For LEED, Savings by Design, GreenPoint Rating, New Solar Homes Partnership

DESIGN AND CONSTRUCTION STANDARDS OUTLINE SPECIFICATIONS

Owner/Operator Involvement in Cx Cx to Facilitate Owner Training & Turnover. Kent Barber, PE Managing Principal KBA

EPIC WISE. Workforce Education for Standards and Efficiency

Efficiency Standards

Commissioning at NYP. Joseph Lorino, PE, LEED Corporate Director April 1, 2014

Commissioning Guide. Transportation and Works Building Design and Construction Division

E mail:

A. General Design and Construction Requirements

LEED v4 for Homes, Residential Project Summary and Checklist One and Two Family New Construction

C A L I F O R N I A E N E R G Y C O M M I S S I O N. Christopher Olvera California Energy Commission Compliance and Enforcement Unit

DIRECTIVE 15H-9 Issue date: October 2018 COMMISSIONING

Preparing a Cx Plan. Technical vs. Process Commissioning TECHNICAL FEATURE

Multifamily Stories and Type R-1. R-2. R-3. R-4

2010 Residential Energy Checklist: Additions/Alterations (Prescriptive Approach)

Nonresidential Code Updates

GreenPoint Rated A Program of Build It Green

building energy efficiency standards CALIFORNIA ENERGY COMMISSION

Refrigerant Charge Verification

PROJECT NAME SECTION GENERAL COMMISSIONING REQUIREMENTS

Highlights of What s New with the 2016 Nonresidential Energy Code

ASHRAE/USGBC/IES Standard What Does It Mean for Commissioning Providers?

Codes and Standards Enhancement (CASE) Initiative 2019 California Building Energy Efficiency Standards

2. Representatives of the facility user and operation and maintenance personnel.

Effective Date: April 25, 2016 Revised: November 7, 2017

ADMINISTRATION CHAPTER 1

Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Residential Compliance June 2014

Nonresidential Ventilation & Indoor Air Quality (IAQ) Final Report

RTR for the Final Report: HVAC Permit and Code Compliance Market Assessment (Work Order 6) Volumes I & 2

ROUND LAKE AREA SCHOOLS DISTRICT 116: LIMITED COMMISSIONING GUIDELINES INTRODUCTION

2019 Title 24 Codes & Standards Enhancement (CASE) Proposal Residential HVAC Measures

Title 24: Where We're Headed with the 2013 Standards. Featuring: Martyn C. Dodd EnergySoft, LLC

1. When using the REScheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

1. Each of the following is a compliance path option for energy conservation code compliance for Residential Buildings except.

Nonresidential. v-class Participant Workbook. Energy Code Ace. December Title 24 Part 6 HELPING YOU PLAY YOUR CARDS RIGHT

Understanding LEED for Homes v4

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

Beyond Code Building Programs. What They are, and What They can Mean to Your Community

Florida Energy Code Update Version

Future of Energy Codes: Stretch Codes The Massachusetts Experience. Isaac Elnecave Senior Policy Manager April 12, 2011

Appendix B. Certification of Intent to Comply

California Advanced Homes Program 2019 Residential Code Changes

ENERGY EFFICIENCY CERTIFICATION

Space Conditioning Systems, Ducts, and Fans (Page 1 of 6)

Commissioning Toolkit for In-House Commissioning of Small Buildings

CxA Gap Session. April 25, :00 p.m. 4:30 p.m. Instructors: Derek De Jesús, CxA, LEED AP Darren Draper, PE, CxA, LEED AP

Errata Sheet. LEED for Schools Reference Guide First Edition for the document titled:

Acceptance Testing and Design Phase Commissioning Topics Stakeholder Meeting #3

B. OPR and BoD documentation may be included by reference for information only.

Attn: Architects, professional engineers, industrial/commercial/institutional contractors and other stakeholders

Space Conditioning System Airflow Rate

Space Conditioning Systems, Ducts, and Fans (Page 1 of 6))

Finding Value in Building Enclosure Commissioning

A. GENERAL INFORMATION

Title 24, Part 6 Code Simplification

Energy Rating Index Performance Path Fact Sheet Development

HERS Ratings and Energy Code Compliance What CEOs and Raters Need To Know About Each Other

PROPOSED SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS 2016 Edition

ENHANCED BUILDING OPERATIONS PROGRAM

Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Residential Compliance June 2014

Community Energy Code Enforcement Policy

Above Code Building Programs

DCRA Guide to Completing Energy Verification Sheets

Commissioning: What Architects Need to Know

Request for Proposal. for. Building Commissioning Services

Third-Party Residential Energy Code Verification

1. When using the REScheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

REQUEST FOR PROPOSAL COMMISSIONING AGENT SERVICES GARRISON ELEMENTARY SCHOOL RENOVATIONS PHASE I

Project Name: Enforcement Agency: Permit Number: Dwelling Address: City Zip Code

Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Residential Compliance June 2014

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

FACILITIES MANAGEMENT

16th ANNUAL SIPA Building Excellence Awards. Official Entry Form. APPLICATION DEADLINE: January 10, 2018

CALGREEN NON-RESIDENTIAL BUILDING Checklist

COMMISSIONING for LEED New and Existing Buildings

Photovoltaic Systems (Page 1 of 3)

Transcription:

Non Residential Commissioning: Title 24 Part 6 (Energy) vs. Part 11 (Cal Green) Contact Role Email Phone Gina Rodda Presenter gina@gabelenergy.com (510) 428-0803 ext 204 CEC Hotline title24@energy.ca.gov (800) 822-6228 Jill Marver Energy Code Ace Program Manager JKZ1@pge.com (925) 415-6844 This program is funded by California utility customers under the auspices of the California Public Utilities Commission and in support of the California Energy Commission.

A website developed by the Statewide Codes & Standards Program to help you meet the requirements of Title 24, Part 6 We offer FREE A variety of tools to help you identify the forms, installation techniques, and building energy standards relevant to building projects in California Traditional classroom, virtual classroom, Decoding Talks via online discussions, and self studies trainings on Title 24, Part 6. Fact Sheets, Trigger Sheets, Checklists, and FAQs to help you understand when Title 24, Part 6 is triggered and how to correctly comply when it is visit us at www.energycodeace.com

CEC & IOUs Architects & Designers Energy Consultants Our Approach In order to improve compliance Builders & Contractors Plans Examiners Building Inspectors & HERS Raters Home & Building Owners Analyze the compliance supply chain market actors unique roles and needs Determine: 1) How current performance compares to desired performance 2) Reasons for the gap 3) Appropriate solutions to improve code compliance Apply appropriate performancebased solutions that meet stakeholders specific needs and preferences 3 3

Examples of Problems & Appropriate Solutions Scoping Study: We interviewed key players in the code industry, and asked: What are the barriers to compliance? How can we help improve compliance? Lack of knowledge or skill The code isn t enforced because people don t know the code. It s too complicated and code officials are uninformed. We need to improve the quality of work being performed by energy consultants and the quality of the Certified Energy Plans Examiners exam. Implementation seen as burdensome Building departments need more resources to properly implement code Lack of electronic forms and automated processes Desired performance isn t expected or rewarded Enforcing energy code seen as competition with life/safety requirements Home and building owners don t demand compliance Contractors who do pull permits can t compete with those who don t

Title 24 Part 6: CEC Documents Energy Standards: 120.8 Chapter 12 Building Commissioning Guide Nonresidential Appendix NA7 Installation and Acceptance Requirements http://www.energy.ca.gov/title24/ 2013standards/index.html 5

Part 6 vs. Part 11 Title 24 Part 11 Occupancy I (Institutional) L (Laboratories) All occupancies: Renewable Energy Systems Landscape Irrigation Systems Water Reuse Systems Title 24 Part 6 Occupancy groups A, B, E, F, H, M, R S, and U: Ventilation Space-Conditioning Systems and Controls Water Heating Systems and Controls Lighting Systems and Controls Electrical Power Distribution Envelope (insulation, fenestration, cool roof, etc.) Acceptance Testing Excluding covered process 6

When Is Cx Required for Title 24 Part 6? Trigger All new nonresidential buildings Does not include additions and alterations Does not include high-rise residential or hotel/motel occupancies (It DOES include a nonresidential occupancy within a mixed use building) Includes all mandatory, prescriptive and performance features covered under Part 6 for conditioned spaces EXCEPT covered process ( 120.6 and 140.9) New nonresidential buildings with conditioned space >10,000 ft 2 : all Cx requirements <10,000 ft 2 : NRCC-CXR forms, Cx Specifications and Acceptance Testing (NRCA forms) only 7

www.energycodeace.com/resources

Owner s Project Requirements (OPR) 120.8(b) What should it include? Energy efficiency goals Ventilation requirements What is this? The purpose of the OPR is to define and document the owner s energy-related expectations and requirements for the system designers prior to the beginning of design. Project program, including facility functions and hours of operation, and need for after-hours operation Equipment and system expectations 9

Basis of Design (BOD) 120.8(c) What is this? The BOD is essentially the system designer s documented response to the requirements laid out in the OPR. What should it include? HVAC systems and controls Indoor lighting systems and controls Water heating systems and controls 10

Design Review (NRCC-CXR Forms) 120.8(d) What is this? NRCC-CXR-01-E: Design Review Kickoff NRCC-CXR-02-E: Basic Review Checklist NRCC-CXR-03-E: Simple HVAC Checklist NRCC-CXR-04-E: Complex HVAC Checklist NRCC-CXR-05-E: Signature Page Who does it? 11

Cx Specifications: 120.8(e) What should it include? List of systems and assemblies commissioned Testing scope Roles and responsibilities of contractors Requirements for meetings Management of issues The commissioning schedule Operations and maintenance manual development Training, and checklist and test form development Execution and documentation What is this? <10,000 ft 2 : The construction documents should include all necessary documentation for the design reviewer to perform the design review (NRCC-CXR). >10,000 ft 2 : To inform bidding contractors of the commissioning requirements so they can include the effort to coordinate with a CxA within their bid, and be contractually obligated to participate. 12

Cx Plan: 120.8(f) What should it include? The commissioning plan should include more detail on roles and responsibilities once the construction team (including subcontractors) are awarded the job. Before permit, this plan will just be a draft. What is this? The commissioning plan is vital to the commissioning process as it communicates to the owner, design, and construction teams what to expect from the CxA, what will be tested, and what role members of the teams must play. 13

Functional Performance Tests: 120.8(g) What should it include? What is this? Functional performance testing (FPT) is used to demonstrate that relevant equipment has been installed and is operating as designed. Issues Log provides a summary of items found during FPT which did not meet design intent or operational requirements. This is not required by Title 24 Part 6, but is strongly recommended. Acceptance forms (NRCA forms) are an aspect of this process for functional testing, which IS required. 14

O&M Training 120.8 (h) What is this? The CxA is responsible for providing a systems manual and associated training to building operation staff. What should it include? Training for maintenance staff (as directed by Cx Plan) on installed equipment and controls. 15

Cx Report 120.8(i) What is this? The Cx Report is the final deliverable in the Cx process. What should it include? The commissioning report should be a compilation of all the documents produced during the Cx process. It should also include a description of the process, and any major findings. 16