WPL Diamond. Environmental Wastewater Solutions. EN approval Compact design No odours. Low visual impact Easy to install

Similar documents
Diamond. Sewage Treatment. Small package sewage treatment plants for domestic and commercial properties

WPL Diamond Compact wastewater treatment plant SIMPLE, RELIABLE & DISCREET

Excellent Treatment

Diamond sewage treatment plant

RainRetain Premium. Rainwater Harvesting. For domestic properties. Environmental Wastewater Solutions

Rainwater Harvesting. for domestic properties. Environmental Wastewater Solutions

SAF SAF SUBMERGED AERATED FILTER THE PARTNER OF CHOICE

SAF SAF SUBMERGED AERATED FILTER THE PARTNER OF CHOICE

Let us help! Free professional site visit with friendly support and advice. to make the right decision or call

/ /

Environmental BA-BD. Envirosafe. Advanced Sewage Treatment Systems. Sustainable, Reliable, Affordable

demand special treatment SAF range techflo TM SAF single stream techflo TM SAF multi stream

Let us help! Free professional site visit with friendly support and advice. to make the right decision or call

Biotec 1-4 Package Sewage Treatment Plants

Sustainable, Reliable, Affordable

Environmental. Entec Biotec. Minitec, P6, P12, P18 & P25 Sewage Treatment Plants. Sustainable, Reliable, Affordable

NSAF range. the conder NSAF range of package sewage treatment plants. clereflo TM NSAF demand special treatment

Sustainable, Reliable, Affordable

BIOFICIENT COMMERCIAL SEWAGE TREATMENT PLANT

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 5000 as described below and as shown on the drawings.

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 4000 as described below and as shown on the drawings.

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 2000 as described below and as shown on the drawings.

Klargester BioFicient+ Domestic Sewage Treatment Plant

SEPTIC TANKS. Let us help! FOR THE COLLECTION SETTLEMENT OF DOMESTIC SEWAGE

DETAI LS OF PROPOSED SEWAGE TREATMENT PLANT

BIOFICIENT+ Wastewater Solutions

Health. Certificate of Accreditation. Sewage Management Facility Aerated Wastewater Treatment System

Wastewater Solutions WASTEWATER SOLUTIONS

Wastewater treatment for single houses. D. O Dowd

EARTHSAFE OWNERS MANUAL WASTEWATER TREATMENT SYSTEMS. All information contained within this manual is the property of Eco Water (QLD) Pty Ltd.

Klargester BioDisc Domestic Sewage Treatment Plant

ULTRA POLYLOK ADVANCED SEWAGE TREATMENT

BioDisc Domestic Sewage Treatment Plant


Sustainable, Reliable, Affordable

WASTEWATER SOLUTIONS. Wastewater Solutions PREMIUM SEWAGE TREATMENT PLANT FOR COMMERCIAL APPLICATIONS FROM THE MARKET LEADERS IN WASTEWATER TREATMENT.

Environmental Septic Tank Systems

ISO WASTEWATER TREATMENT SYSTEMS. JFC Polska Sp. z o.o. www: oczyszczalnie-jfc.pl ENVIRONMENTAL LY CERTIFIED HIGHEST QUALITY ISO WE HAVE

Wastewater & Rainwater Solutions

NON-ELECTRIC SEPTIC SYSTEMS

Pollution Control BH-BL. BioDisc. High Performance Package Sewage Treatment Plants for Residential, Business & Leisure Applications. klargester.

Activated Sludge Treatment Extended Aeration (EA) and Sequencing Batch Reactor (SBR) Systems

NON-ELECTRIC SEPTIC SYSTEMS

Compact Waste Water Treatment MBR /MBBR Technology

BioDisc BE-BL BA-BD. High Performance Package Sewage Treatment Plants for Residential, Business & Leisure Applications

Sewage treatment plants tackle seasonal flows for holiday park

Environmental Septic Tank systems

WHAT TO CONSIDER IN CHOOSING A SYSTEM

BioDisc BE-BL. Environmental BA-BD. High Performance Package Sewage Treatment Plants for Residential, Business & Leisure Applications

AQUAROBIC MINI-PLANT TM

TECHNICAL SPECIFICATION

BIODISC. Let us help!

Stormwater Attenuation Systems Sustainable Drainage Solutions for Domestic & Commercial Applications

Attachment N o F Control & Monitoring

TECHNICAL BROCHURE WASTEWATER TREATMENT SYSTEMS

Klargester Pumping Stations Product Guide

REFLECTION ISF INFORMATION RWTS.CO.NZ. Pure. Wastewater. Solutions.

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water

EVW 2 Hynds Commercial Wastewater Systems April 2013

EARTHSAFE OWNERS MANUAL WASTEWATER TREATMENT SYSTEMS. All information contained within this manual is the property of EcoWater (QLD) Pty Ltd.

SEPARATORS A RANGE OF FUEL/OIL SEPARATORS FOR PEACE OF MIND

Certificate of Accreditation

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units

Pollution Control. A Range of Package Pump Systems for Residential & Commercial Developments. klargester.com

Treatment Systems How they work and what to consider when selecting one. Joe Walsh IOWA Conference 2015

RAINWATER HARVESTING SYSTEMS

RAINWATER HARVESTING SYSTEMS

RAINWATER HARVESTING SYSTEMS FOR DOMESTIC APPLICATIONS

Service & Support Solutions. FOG for Fuel. By: James Curran Kingspan Environmental Services

Turbo4bio System For the Treatment of Sewage & Organic Effluents

Akiki Engineering Est.

Environmental SAVE ON WATER BILLS MONEY. Rainwater Harvesting Systems for Domestic Applications. Sustainable, Reliable, Affordable

ardt Certificate of Accreditation Sewage Management Facility Aerated Wastewater Treatment System

SEPARATORS A RANGE OF FUEL/OIL SEPARATORS FOR PEACE OF MIND

Excellent Treatment

BALMORAL TANKS FULL RETENTION AND BYPASS SEPARATORS. Introduction. Applications/uses. Principles of operation. What is an oil separator?

Marsh Industries. Domestic wastewater treatment products

Balmoral HydroClearTM

Table of Contents Introduction... 3

Severn Trent Services Wastewater Solutions End-to-End Wastewater Treatment Solutions

Separators. A Range of Fuel/Oil Separators for Peace of Mind.

FLUIDO. Fully Biological Sewage Treatment Plant. We clear it for you. according to EN Packaged Sewage Solutions with a Future (4-300 PT)

Schedule 1: Specification. Super-Treat SE 10 Aerated Wastewater Treatment System

MST FIBRE MECHANIICAL SEPTIC TANK SMALL SEWAGE TREATMENT SYSTEM

Error! Bookmark not defined.

Pollution Control. Klargester Off-mains. Market Leading Off-mains Sewage Solutions. klargester.com

Certificate of Accreditation

Balmoral HydroClearTM

Ecomotive. by Jets.

*Applies to models CLF1 CLF7 only

SECTION A-A. Blower Housing. Settling Zone Volume times daily flow. Treatment Zone. SaniTEE 818-B. Vent. Shutoff Valve.

Government Decree on Treating Domestic Wastewater in Areas Outside Sewer Networks (542/2003)

Klargester Product Guide

Rainwater Harvesting Systems for Domestic Applications

Rainwater Harvesting for domestic properties, commercial buildings and school premises

YOUR ONE STOP WASTEWATER MANAGEMENT CENTER Copyright 2014 Tomher Environmental SB. All rights reserved.

Best practice in monitoring process, operation and maintenance of wastewater treatment plants 12 September 2011, Bucharest

SECTION-I. b) Write a short note on pumping of savage. 4

Definition for nominal designation shall be added, see pren

Section 4: Aerated Wastewater Treatment Systems. 4. Aerated Wastewater Treatment Systems

Transcription:

EN12566-3 approval Compact design No odours WPL Diamond Small packaged sewage treatment plants for domestic and commercial properties Environmental Wastewater Solutions Low visual impact Easy to install

The WPL Diamond The WPL Diamond range of packaged sewage treatment plants is specifically designed for properties not connected to mains drainage. Our unique sewage treatment system includes innovative features that makes it your number one choice. Our commitment to the highest quality products, supported by our friendly, knowledgeable after sales service adds up to the best wastewater treatment solution on the market. In domestic applications the Diamond comes in a range of sizes and can provide treatment for domestic population equivalents of up to 55 persons, meeting consent standards of 20mg/l Biological Oxygen Demand, 30mg/l Suspended Solids and 20mg/l Ammoniacal Nitrogen. The Diamond is also an ideal wastewater solution for many commercial applications. Typical domestic uses include: Single houses Small groups of houses, with maximum population equivalent of 55 persons Replacement of septic tanks Typical commercial uses include: Offices Factories Bed and breakfasts Farm shops Other rural businesses Diamond features CE EN12566-3 European approval Effluent Standard: 20mg/I BOD; 30mg/I SS; 20mg/l NH3 No odours No settlement required, in a fully mixed aerobic reactor. Correct ventilation required. Below ground for low visual impact Below ground installation with a small lid, flush with the ground. Easy to install with minimal labour Compact design, reducing excavation and handling costs. Variable inlet depths available with a choice of extension kits. Up to 3 year de-sludge intervals on the DMS range Efficient, continuous, bacterial digestion process (DMC range usually requires annual de- sludging). Low running costs and user maintenance No internal moving parts, reliable operation and minimal maintenance. Alarm beacon included All weather, air blower kiosk fitted with a failure alarm beacon (+ second alarm beacon as standard for external pump chamber models). Robust design and construction Manufactured using high quality components. Load tested and water tight. Protecting the Environment WPL Diamond treats sewage to Environment Agency approved levels without the need to add chemicals. The final effluent can be safely discharged to a soakaway, watercourse or ditch. Your plant comes complete with a kiosk and 10 metres of airline to connect the blower and tank. WPL Diamond DMS plant and kiosk with Alarm Beacon pictured right.

Flexible options External Pump Chamber (EPC) If the location of the Diamond plant is on an incline, in a high water table area or a long distance away from the designated discharge point (ie: soakaway/water course/ditch) the final effluent may require pumping. The Diamond DMS range can be specified with an EPC which can deliver up to 100 litres per minute of effluent at a head of 4m. The EPC can be simply retro-fitted and is easy to maintain. EPC consists of: 240v, 0.25kw submersible pump, integral float switch with stainless steel internals High level alarm beacon Junction box 32mm MDPE Pipe outlet Invert extension kit for the EPC also available (optional extra) Sample Chamber A compact chamber designed to allow easy sampling of treated wastewater (final effluent) which may be required periodically by the Environment Agency or other regulatory authorities. Invert Extensions The Diamond range offers one of the widest choices for invert extensions giving complete flexibility for different site conditions and installation requirements. This can enable alignment to existing pipework. Turret invert extension during installation The WPL Diamond standard We pride ourselves on the fact that the WPL Diamond meets the following standards and codes of practice: CE Marked Fully tested, accredited and certified under the BS EN12566-3 standard Environment Agency Fully compliant with recommendations and exceeds normal consent standards UK Building Regulations Fully compliant with Part H2 Environmental Permitting Programme 2 (EPP2) Meets current legislation for exemption from a permit to discharge by the Environment Agency British Water Designed using the British Water Code of Practice Flows and Loads, to ensure the tank is correctly sized LABC Registered Pre-registered with Local Authority Building Control and is recognised by all LABC inspectors in England & Wales +44 (0)23 9224 2600 enquiries@wpl.co.uk www.wplinternational.com

How does the WPL Diamond plant work? Process Performance Tested, Certified & Guaranteed* Certified efficiency of up to 97% for pollution removal (BOD) under European performance standards. The Diamond treats wastewater to a 95th percentile standard of: 20mg/l Biological Oxygen Demand (BOD) 30mg/l Suspended Solids (SS) 20mg/l Ammoniacal Nitrogen (AMM-N) If more stringent environmental requirements are specified, please contact WPL on +44 (0)23 9224 2600 *Subject to consistent influent conditions and regular plant maintenance as per the manufacturer s instructions. A. The wastewater flows into the main tank and enters directly into the bio-chamber (B) through this inlet pipe (A). B. This is where the biological process begins. The bio-chamber (B) is an aerated zone where the solids circulate and are thereby biologically treated. Part of the solids settle in to area (C) only to be re-circulated via the draft tube (D) and retreated. C. In this area, the settled solids from the biochamber (B) and the clarifier (E) are drawn up through the draft tube again and released into the bio-chamber for re-treatment. D. The draft tube enables the solids to be drawn back up into central aeration chamber and recirculated through the treatment process. E. The clarifier is an aeration free zone where fluid flows upwards, being displaced by further effluent entering the system. The remaining solids settle out again into area (C) and are re-circulated via the draft tube (D) into the bio-chamber (B). F. The clarified liquid passes through the dip pipe and out into the environment. The Diamond system is completely below ground, with only a small green lid visible to blend in with your landscaping.

Easy installation The Diamond plant is easy to install. It is a compact design which requires less excavation to install compared to other plants, and in some situations no concrete backfill is needed. A comprehensive installation manual is always supplied with each Diamond plant, explaining the installation process in detail and should be read thoroughly prior to installation by your chosen installer. WPL recommends using a qualified and experienced installer. Please contact a member of the WPL Sales Team if you need help finding one. Technical information Loadings (based on British Water Code of Practice) and Blower Power Rating Model DMS2 DMS3 DMS4 DMS5 DMC6 DMC7 DMC8 DMC9 Population range (persons) 1-6 5-11 10-15 14-20 21-27 28-35 36-45 46-55 Maximum organic loading BOD/day (grams) 360 660 900 1200 1620 2100 2700 3300 A WPL/British Water Loading Guide providing further information for non-domestic applications is available Blower Motor Size (kw)* single phase rating 0.105 0.125 0.160 0.210 0.550 0.9-1.1** 0.9-1.1** 0.9-1.1** * Actual power consumption may vary (dependent on motor efficiency and nature of installation), size stated is the motor size NOT actual power consumption ** For DMC7, DMC8 AND DMC9 models using 3 Phase electrics, blower motor is rated at 0.9 kw Process performance is subject to strict adherence to WPL s Installation Manual, User Guide/Operation & Maintenance Manual, and a start up period of 6-12 weeks depending on plant loadings and water temperature. Dimensions Model Max Outside diameter Height to inlet *Inlet invert depth (mm) **Height to outlet Max height/ In ground depth Weight empty (kg) Total capacity (ltr) DMS2 1.74 1.70 630 1.61 2.33 155 2270 DMS3 1.96 1.83 760 1.73 2.59 192 3030 DMS4 1.99 2.00 780 1.93 2.78 210 3975 DMS5 1.99 2.00 780 1.93 2.78 210 3975 DMC6 3.30 2.78 570 2.68 3.35 380 9056 DMC7 3.30 2.78 570 2.68 3.35 380 9056 DMC8 3.30 3.14 580 3.04 3.72 460 15038 DMC9 3.30 3.14 580 3.04 3.72 460 15038 * Deeper inverts can be accommodated with our range of standard invert extensions. All dimensions +/- 3% tolerance. ** Diamond units equipped with an EPC have 32mm MDPE Pipe outlet and the outlet invert depth is 300mm for all of models. For more information on any of the above, contact a member of the WPL sales team.

I A Call: Fax: Email: Web: Address: +44 (0)23 9224 2600 +44 (0)23 9224 2624 enquiries@wpl.co.uk www.wplinternational.com WPL Limited Units 1 & 2 Aston Road Waterlooville Hampshire PO7 7UX United Kingdom Where to buy WPL products: WPL Diamond Plant Operation & Maintenance The Environment Agency requires all sewage treatment plants to be operated and maintained in accordance with the manufacturer s maintenance instructions. Every WPL Diamond comes with a helpful Operation and Maintenance User Guide and Maintenance Log Book which must be updated when the regular maintenance and de-sludging is carried out. Records must be retained for a minimum of 5 years by the consent holder. Maintenance should only be undertaken by a qualified service engineer accredited by British Water. Warranty About WPL Limited WPL Limited provides innovative and reliable wastewater treatment and grease management systems for domestic, commercial and industrial markets as well as holding a prominent position as a supplier to the water companies. As an internationally recognised leader in the design, manufacture and supply of both standardised, and bespoke environmental solutions, WPL Limited is dedicated to ensure the provision of high quality products and services. To see more WPL products please visit: www.wplinternational.com Environmental Policy WPL Limited is ISO14001 accredited. WPL Limited rigorously fulfils its vision of protecting the environment by delivering reliable wastewater solutions. A strong focus on quality and compliance ensures that all wastewater treatment systems are designed to work within the guidelines of the British Water Code of Practice and exceed all present and proposed discharge consent standards enforced by the Environment Agency, SEPA, NIEA, Natural Resource Wales in the UK and national regulatory authorities around the world. WPL tank warranty is 10 years and air blower 2 years on a DMS, subject to consistent influent conditions and regular plant maintenance as per the manufacturer s instructions. For more information, please contact WPL. L R I B A C P D E R M A T E D S S E A S S WPL Limited registered in England & Wales NI 2583411 VAT No. 568 3801 15. WPL Limited has a policy of continual product development and the above information may be subject to change without notice. WPL Limited are fully compliant with the British Water Code of Practice. WPL Ltd reserve the right to change specifications in line with company policy of improvement through research and development. Errors and omissions excepted. Models shown in this brochure may include additional cost options that are not part of the standard specification.