SECTION FLAGPOLES. 1.1 SUMMARY A. Section Includes: 1. Fixed high dimensional, ground set, uniform conical taper, seamless tube flag pole.

Similar documents
SECTION FLAGPOLES

Attachment A-Flagpole(s) Specifications

MCINTOSH COUNTY SCHOOLS TODD GRANT (K-5) SCHOOL DEMOLITION AND FINISHED SITE WORK

SECTION COILING COUNTER DOORS

SECTION DECORATIVE METAL FENCES AND GATES

SECTION PASS WINDOWS. 1.1 SUMMARY A. Section Includes: 1. Factory finished sliding glass, counter mounted pass windows.

D I V I S I O N 10: S P E C I A L T I E S

SECTION WALL AND DOOR PROTECTION

SECTION ROOF SPECIALTIES

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

SECTION CHAIN LINK FENCES AND GATES

SECTION RESILIENT SHEET FLOORING

SECTION EXPANSION JOINT COVER ASSEMBLIES

SECTION BLAST RESISTANT WINDOWS

SECTION ACCORDION FOLDING PARTITIONS

SECTION ALUMINUM STORM WINDOWS

SECTION DIRECTORIES

SECTION OVERHEAD COILING SHUTTERS

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION FOUNDATION DRAINAGE

SECTION ROOF ACCESSORIES

SECTION SERVICE AND TELLER WINDOW UNITS

SECTION LOUVERS AND VENTS

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION SHOWER AND DRESSING COMPARTMENTS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION ROOFING AND SIDING PANELS

SECTION DETENTION WINDOW SCREENS. 1. Detention screens for interior and exterior installations at exterior windows in existing buildings.

SECTION MISCELLANEOUS METALS

SECTION ALUMINUM STORM WINDOWS

SECTION ROOF SPECIALTIES

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION COILING DOORS AND GRILLES

SECTION TURBINE VENTILATORS

SECTION VISUAL DISPLAY SURFACES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION SITE FURNISHINGS

SHORING & UNDERPINNING 02250

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION METAL STAIRS

STANDARD SPECIFICATION FOR ALUMINUM FRAMING FOR RAILROAD PASSENGER SHELTERS

SECTION RESINOUS FLOORING

Product Guide Specification


Architectural Wall Products Guide Specifications

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

SECTION DECORATIVE METAL RAILINGS

SECTION CHAIN LINK FENCES AND GATES

Work Order Number *************************************************************************** SECTION C20 STAIRS 02/18

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION ORCHESTRA PIT FILLER

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION EXPANSION CONTROL

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

Product Guide Specification

Architectural Roof and Wall Products Guide Specifications

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

A/E Project No January 27, 2014

SECTION STEEL DECKING

SECTION MULTICOLOR INTERIOR FINISHING

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

SECTION AWNINGS

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

SECTION STANDING SEAM METAL ROOFING

SECTION LINEAR METAL CEILINGS

SECTION BRICK FLOORING

SECTION EXPANSION CONTROL

NOTE TO SPECIFIER: This section is based on the products of Solar Innovations, Inc., which is located at:

SECTION GLASS BALUSTRADE RAILING SYSTEMS

Aluminum Component Pipe Railings

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECTION EXPANSION CONTROL

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION DUALGARD SNOW GUARDS

American Metal Specialties, Inc.

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION TERRAZZO FLOOR TILE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Architectural Roof and Wall Products Guide Specifications

Aluminum Perforated Rolling Door

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

SECTION METAL STAIRS

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

CSI, CCCA, CPSD, CPSM, GGP, LEED AP, SCIP,

SECTION DECORATIVE METAL FENCES AND GATES

SECTION DECORATIVE METAL FENCES AND GATES

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

SECTION ALUMINUM WINDOWS

Trex Commercial Products page Metal Railing

SECTION EXPANSION CONTROL

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

SECTION ALUMINUM GATES

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

Transcription:

SECTION 10 75 00 FLAGPOLES SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fixed high dimensional, ground set, uniform conical taper, seamless tube flag pole. 1.2 RELATED REQUIREMENTS SPEC WRITER NOTE: Update and retain references only when specified elsewhere in this section. A. Concrete for Ground Set Flagpole: Section 03 30 00, CAST-IN-PLACE CONCRETE. B. Flagpole Finish Color: Section 09 06 00, SCHEDULE FOR FINISHES. C. Excavation and Backfill: Section 31 20 00, EARTHWORK. 1.3 APPLICABLE PUBLICATIONS A. Comply with references to extent specified in this section. B. American Society of Civil Engineers/Structural Engineering Institute (ASCE/SEI): 1. 7-10 - Minimum Design Loads for Buildings and Other Structures. C. ASTM International (ASTM): 1. A240/A240M-15b - Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications. 2. B209-14 - Aluminum and Aluminum-Alloy Sheet and Plate. 3. B209M-14 - Aluminum and Aluminum-Alloy Sheet and Plate (Metric). 4. B241/B241M-12e1 - Aluminum and Aluminum-Alloy Seamless Pipe and Seamless Extruded Tube. 5. C33/C33M-13 - Concrete Aggregates. 6. C920-14a - Elastomeric Joint Sealants. D. Master Painters Institute (MPI): 1. No. 35 - Bituminous Coating. E. National Architectural Metal Manufacturers(NAAMM): 1. AMP 500-06 - Metal Finishes Manual. 2. FP 1001-07 - Guide Specifications for the Design of Metal Flagpoles. 10 75 00-1

1.4 SUBMITTALS A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Submittal Drawings: 1. Show size and installation details for flagpole, base, and finial ball. C. Manufacturer's Literature and Data: 1. Description of each product. 2. Installation instructions. D. Qualifications: Substantiate qualifications comply with specifications. 1. Installer // with project experience list //. E. Delegated Design Drawings and Calculations: Signed and sealed by responsible design professional. 1.5 QUALITY ASSURANCE A. Installer Qualifications: 1. Installed specified products with satisfactory service on five similar installations for minimum five years. a. // Project Experience List: Provide contact names and addresses for completed projects. // 1.6 DELIVERY A. Deliver products in manufacturer's original sealed packaging. B. Before installation, return or dispose of products within distorted, damaged, or opened packaging. 1.7 WARRANTY SPEC WRITER NOTE: Always retain construction warranty. FAR includes Contractor's one year labor and material warranty. A. Construction Warranty: FAR clause 52.246-21, "Warranty of Construction." PART 2 - PRODUCTS 2.1 SYSTEM PERFORMANCE A. Delegated Design: Prepare submittal documents including design calculations and drawings signed and sealed by registered design professional, licensed in state where work is located. B. Design flagpole assemblies complying with specified performance: 10 75 00-2

1. Wind Loads: NAAMM FP 1001. 2. Seismic Loads: ASCE/SEI 7. 2.2 MATERIALS SPEC WRITER NOTE: Make material requirements agree with applicable requirements specified in the referenced Applicable Publications. Update and specify only that which applies to the project. A. Aluminum, Extruded: ASTM B241/B241M, Alloy 6063 - T6. B. Aluminum, Plate and Sheet: // ASTM B209M // ASTM B209 //, Alloy ll00. C. Stainless Steel: ASTM A240/A240M, Type 304. 2.3 PRODUCTS - GENERAL A. Basis of Design: Section 09 06 00, SCHEDULE FOR FINISHES. 2.4 FABRICATION SPEC WRITER NOTE: Coordinate flagpole height with the number of sections required for fabrication and shipping. Between 9 m and 12 m (30 feet and 40 feet), flagpoles can be one or two pieces. Two-pieces are easier to ship but there may be a preference for one piece. Over 12 m (40 feet), flagpoles are two pieces and over 15 m (50 feet), they are three pieces. A. Fabricate flagpole of seamless extruded aluminum tube, uniform conical taper of approximately 1 in 70 (1 inch in every 72 inches). 1. Maximum Taper: 50 percent of flagpole outside base diameter. 2. Sectional Flagpoles: Provide self-aligning sleeves for field joint. B. Base: Aluminum plate or stainless steel, of stock design as indicated on drawings. C. Finial Ball: 2 mm (0.08 inch) thick spun aluminum sphere, with seams welded flush and watertight. Mount ball on threaded rod to fit truck. 1. Ball Diameter: Match flagpole butt diameter. 10 75 00-3

SPEC WRITER NOTE: Truck, halyards, and cleats in the following paragraphs are for an external system, which is most common. D. Truck: Equip pole with extra heavy, revolving, non-fouling, ball bearing type truck with cast aluminum body. Fit truck with two cast aluminum, nylon bushed sheaves on stainless steel axles. E. Halyards: Two sets of 9 mm (3/8 inch) diameter, nylon braided rope with minimum two bronze swivel snaps for each halyard. F. Cleats: Two aluminum cleats minimum 225 mm (9 inches) long. Secure cleats to pole with two 9 mm (3/8 inch) flat head aluminum machine screws. G. Foundation Sleeve: Galvanized, corrugated steel, length as indicated on drawings, welded to steel base plate. 1. Weld lightning ground rod of 19 mm (3/4 inch) diameter galvanized steel to base plate at bottom of sleeve. H. Flashing Collar: Material and finish to match flagpole. 2.5 FINISHES A. Finish flagpole exposed surfaces. B. Stainless Steel: NAAMM AMP 500; No. 4 polished finish. C. Aluminum Anodized Finish: NAAMM AMP 500. 1. Color Anodized Finish: AA-C22A42 or AA-C22A44; Class I Architectural, 0.018 mm (0.7 mil) thick. D. Aluminum Satin Finish: NAAMM AMP 500. 1. Mechanical Finish: AA-M323 Directional Textured, Coarse Satin and AA-M20, Buffed. E. Flagpole Shaft: Satin aluminum finish, then heavily waxed. F. Finial Ball: Gold color anodized aluminum, then heavily waxed. G. Base and Cleats: Finish to match flagpole. 2.6 ACCESSORIES A. Sand: ASTM C33/C33M. B. Sealant: ASTM C920, elastomeric type recommended by flagpole manufacturer. C. Bituminous Paint: MPI No. 35. PART 3 - EXECUTION 3.1 PREPARATION A. Examine and verify substrate suitability for product installation. 10 75 00-4

B. Excavate flagpole foundations as specified in Section 31 20 00, EARTHWORK. C. Provide foundation tube for installation as work of Section 03 30 00, CAST-IN-PLACE CONCRETE for installation in flagpole footing. D. Place concrete as specified in Section 03 30 00, CAST-IN-PLACE CONCRETE. 3.2 INSTALLATION A. Install products according to manufacturer's instructions // and approved submittal drawings //. 1. When manufacturer's instructions deviate from specifications, submit proposed resolution for Contracting Officer's Representative consideration. B. Coat flagpole section within foundation sleeve with bituminous paint. C. Install flagpoles centered in foundation sleeve. D. Fill space between pole and metal sleeve to within 50 mm (2 inches) of top with sand and compact. E. Fill remainder of space with sealant and install flashing collar as indicated on drawings. - - E N D - - 10 75 00-5