Albi DriClad FIREPROOFING APPLICATION MANUAL & FIELD GUIDE. Albi Manufacturing Division of StanChem, Inc. 401 Berlin Street East Berlin, CT USA

Similar documents
Albi DriClad FIREPROOFING APPLICATION MANUAL & FIELD GUIDE

A/D Firefilm III PRODUCT DATA SHEET

SECTION INTUMESCENT MASTIC FIREPROOFING

RSIC-1-INSTALALTION GUIDE RSIC-1 SOUND ISOLATION CLIP

Thin-profile, flexible, high-thermal-resistance blanket

Installation and Use Instructions for the Big Ass Workbench Manufactured by Mercer Innovation, LLC

RSIC-V RSIC-V INSTALLATION GUIDE RSIC-V SOUND ISOLATION CLIP

ION Fresh & Clean Ventilation System Part # Basement Unit Part # Crawlspace Unit

Ion Fresh & Clean Ventilation System

RSIC-V INSTALLATION GUIDE RSIC-V SOUND ISOLATION CLIP. PAC International, Inc. Tel: (866) Fax: (866) Web Site:

Fire Barrier Duct Wrap 615+

Installation Instructions

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

RSIC-1 SOUND ISOLATION SYSTEMS RSIC-1 INSTALLATION GUIDE

SECTION APPLIED FIREPROOFING

Design No. D929 February 07, Restrained Assembly Rating 1, 1-1/2, 2, or 3 Hr. (See Items 1, 5, 9, 10, 14)

Model Number: 1300 Series

RAY-CORE Structural Insulated Roof and Wall Panels

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

Normal, Medium And High Density Fireproofing Materials

EJOT Solar Fastenings. Installation Manual

Technical Data Sheet

Carved Tile DYNAMIC & EASY-TO-INSTALL. turf.design 844 TURF OMG. pat e n t pending

CALCULATION METHODS FOR STRUCTURAL FIRE PROTECTION

Fire Barrier. Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes

RSIC-1. RSIC-1, the Low Cost, High Performance, Noise control Solution. RSIC-1 specifications:

SECTION INSULATION. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

3 Scotch-Weld. Control Joint Sealant DP-5106, Self-Leveling, Gray. Technical Data July, 2006

PETOL Flange Lifter FLA5000. Data Book. Warning

PETOL Flange Lifter FLA Data Book. Warning

Technical Data for. Headers. and Beams

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Architectural Decking panels and Fabrications REVISED 11.

INSTALLATION PROCEDURE

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

breathability to prevent the potential for moisture condensation within exterior walls...

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS

High Strength LITE Family Of Products

instructions 8 x 4 ft Proslat panel section 8PRO001-AUG1815

EPV Pellet Vent Pellet Stove Venting System Installation Instructions

Wabo Modular STM and D Series Large movement expansion joint system

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

Process Returns in VOTW

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

3M Fire Protection Products 3M Interam Endothermic Mat For Commercial Buildings

We greatly appreciate your business and promise to work hard to provide you with the highest level of service at all times.

Skylight & Sidelight Panels

LISTING INFORMATION OF CCI Manufacturing Inc. - HiBAR SPEC ID: CCI Manufacturing Inc Ave. Edmonton, AB T5V 1K5 Canada

1-2-3MORTAR Modified Portland cement based mortar, to be used to adhere any prefabricated construction elements

Fire Protection Products

Fire Protection Products

PRR. Flush Mount Racking System. Installation Manual

INSTALLATION MANUAL & Warranty Information

Precison Manufacturing

INSTALLATION PROCEDURE

RSIC-1 RSIC-1 INSTALLATION GUIDE RSIC-1 SOUND ISOLATION CLIP CONCRETE CMU

Nutech Concrete Range

P R O D U C T P R O F I L E

CURTAINWALL DEFLECTION SOLUTIONS

RSIC-1EXT04 SOUND ISOLATION CLIP RSIC-1EXT04 INSTALLATION GUIDE

Arborite also offers regrind product (GSCR). This is a regraded product that can be used as a backing grade (pending upon availability).

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: ISOLATEK INTERNATIONAL

THE RSIC-1 EXT04 SOUND ISOLATION CLIP

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

MODEL NUMBER: 1419 SERIES

DIVISION 5 METALS SECTION METAL DECKING

ASTM D 991 TEST FIXTURE

ICC-ES Evaluation Report Reissued December 1, 2011 This report is subject to renewal in two years.

Festoon Manual Heavy Duty C-Track

Handling, Installation and Operating Instructions for HD Q-PAC Media. revised May 2004

SERIES W1S & W2S ACCESS COVERS. With Grating Panels

Concrete Faced Insulated Perimeter Wall Panels. Durability. Sustainability. Energy Efficiency. Durable Finish & Superior Insulation in One Easy Step

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

TEST REPORT ON. TESTED FOR: Central States Manufacturing, Inc. 302 Jane Place Lowell, AR Telephone: (800) Fax: (800)

Carved Tile DYN A MI C & EASY-TO-I N STAL L. pat e n t p e n d i n g

TEST REPORT ON 26 GA. PBR PANELS AT 5' 0" PANEL SPANS WITH 26 GA. SEALED N SAFE THERMAL BLOCKS IN ACCORDANCE WITH ASTM E AND AISI S907-08

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

Marinite P structural insulation is

General Safety Information

... your Material Handling Specialist. MC300HD Conveyor. echnology. with MicroSpan. Technology

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Drag Chain Conveyor Installation and Operation Manual

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

Technical Report. Executive Summary. Testing of PV Backsheet bonded to asphalt shingles using PVA 900HM

QUOTE PROPOSAL. OverheadCraneKit.com. Presented by: Date: Quote ID: E1000. OverheadCraneKit.com

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Dura Rack Family Of Products. 237,000 sq. ft. manufacturing facility

PRODUCT DATA SHEET Metacaulk BOX GUARD Classified under Wall Opening Protective Material as found in UL's Fire Resistance Directory

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Hollow Core Building Panels Products and Fabrications REVISED 11.

1. This addendum contains the specifications for Acoustical Ceilings: public areas Lobby, Breakfast Room, etc. and not used on all doors.

Fire-resistant Sound absorbent High density for sag-free, tight fits Green features for sustainable development

MASTERCRAFT EXTERIOR FIBERGLASS DOOR

SQ-1 ROOF TRUSS WEG-IT TABLE

RSIC-1-LOW PROFILE SOUND ISOLATION CLIP RSIC-1-LOW PROFILE INSTALLATION GUIDE RSIC-1 LOW PROFILE. For use in conjunction with the RSIC-1 clip

RSIC-1-LOW PROFILE SOUND ISOLATION CLIP RSIC-1-LOW PROFILE INSTALLATION GUIDE RSIC-1 LOW PROFILE. For use in conjunction with the RSIC-1 clip

Copyright Notice. HCL Technologies Ltd. All rights reserved. A DEFINITIVE GUIDE TO DESIGN FOR MANUFACTURING SUCCESS

Transcription:

Albi DriClad FIREPROOFING APPLICATION MANUAL & FIELD GUIDE Albi Manufacturing Division of StanChem, Inc. 401 Berlin Street East Berlin, CT 06023 USA Tel: (860) 828-0571 Fax: (860) 828-3297 www.albi.com

TABLE OF CONTENTS Introduction.. 2 Page Product Description Albi DriClad 3 Equipment Recommendations.. 4 Application Details Typical Details.... 5 Beam.. 6 Columns.. 7 Assemblies.. 8 Underwriters Laboratories Listings... 9-11 Warranty Information. 12

INTRODUCTION Throughout the years, Albi has earned an enviable reputation for its dependable, high quality fireproofing systems. Providing maximum protection with minimum thickness, our line of Albi Clad intumescent fireproofing materials have demonstrated their unique ability to withstand abuse, impact, vibration and adverse environmental conditions, while still continuing their outstanding performance record and aesthetic properties. This manual has been prepared to provide you with basic information pertinent to the properties and application methods of Albi DriClad. Further, equipment recommendations and application suggestions are included to assist you and your job superintendent in proper job preparation and professional execution of work. The objective of this manual is to explain the necessary components and methods to provide the required fire protection as specified by the owner or architect. It is your responsibility, as a competent and reputable applicator, to apply the product in accordance with ULI tests and in compliance with our recommendations. It is important that you have full knowledge of our product and its application methods in order to maintain our record of proven performance and consistent customer satisfaction. We urge your studied review of the information contained in this manual and the transmission of this same information to all personnel who will be involved in the application of Albi DriClad. As additional information is developed, it will be forwarded to you for insertion in this manual. Should you desire additional copies, or should there be questions requiring clarification, please contact our home office or your regional sales representative.

ALBI PRODUCT DESCRIPTION Albi DriClad is a semi-rigid board manufactured from molten volcanic rock which is spun into fine threads, impregnated with a special resin and compressed to form a durable, yet easy to use material which has superior fire resistance properties. Albi DriClad is used to fireproof structural steel and is installed using Albi DriClad screws. Albi DriClad meets the fire test criteria of ASTM E84, ASTM E119, and UL263. Albi DriClad is listed by Underwriter's Laboratories, Inc. and is designed for rapid installation to columns, beams, floor/ceiling, and roof/ceiling assemblies for fire ratings up to 4 hours. Due to its high moisture resistance Albi DriClad is suitable for application to both interior and exterior surfaces which are initially exposed to the weather during construction. Albi DriClad can also be used in semi-exposed conditions such as parking garages. Albi DriClad Shipping Specifications ALBI DRICLAD UL Classified Mineral Board* Material Thickness Material Thickness Material Thickness Material Thickness Material Thickness 1.0 inch 1-1/2 inch 1-5/8 inch 2.0 inch 2-1/2 inch Sheets per Pallet 45 sheets 30 sheets 28 sheets 22 sheets 20 sheets Total Square Feet per Pallet 1080 sq. ft. 720 sq. ft. 672 sq. ft. 528 sq. ft. 480 sq. ft. Gross Weight per Pallet 900 lbs. 900 lbs. 900 lbs. 900 lbs. 900 lbs. All sheets are 4 ft. x 6 ft.

EQUIPMENT RECOMMENDATIONS Cutting As a board material, the most efficient method for cutting is with a standard table saw. It is recommended that the saw have a dust collection system to help control any air born mineral fibers. For small jobs it may be more efficient to use a circular saw (with a dust collection unit) or even a broad knife. Installation The installation of the Albi DriClad requires the use of our AlbiScrew system. These pig tail type screws are most efficiently installed using a cordless drill, fitted with either a #10 countersink bit or philips head bit. Miscellaneous For small cuts around clips, hangers, etc a thin bladed, rigid, steak knife is the most efficient.

PREPARATION Albi DriClad requires no special treatment to the steel substrate. Cut boards to size with due allowance for steel tolerances and board thicknesses. INSTALLATION SEQUENCE (A) Cut noggings 4" wide or more and push fit into web at 2'-0" centers as shown in figure 1. Ideally, nogging should extend slightly beyond flange tip 1/16". For beams with webs deeper than 18" use tee-shaped noggings as shown in figure 5. (B) Cut side boards to suit depth of steel section plus thickness of fireproofing board. Install DriClad boards using two AlbiScrews at each end and at each intermediary nogging. (See figures 3 and 4) (C) Cut width of soffit boards to fit between side panels (nominal width of flange). Install panel tight up to flange with AlbiScrews at 6" centers along each side as shown in figures 3 and 4. For beams with flanges wider than 12" soffit boards may require additional support. As an example, use insulation pins as shown in Figure 6. *Steel should be free from dust and loose particles where noggings are to be installed. TYPICAL APPLICATION DETAILS

TYPICAL APPLICATION DETAILS (cont.)

TYPICAL APPLICATION DETAILS (cont.)

TYPICAL APPLICATION DETAILS (cont.)

UNDERWRITERS' LABORATORIES, INC. - LISTINGS COLUMNS: Wide Flange FIRE TEST: ASTM E-119 COLUMN U.L. HOURLY MATERIAL W10 x 49 X-313 1 hr. 1 inch X-313 1-1/2 hrs. 1-1/2 inches X-313 2 hrs. 1-1/2 inches X-313 3 hrs. 2-1/2 inches W12 x 120 X-313 1 hr. 1 inch X-313 1-1/2 hr. 1-1/2 inches X-313 2 hrs. 1-1/2 inches X-313 3 hrs. 1-1/2 inches X-313 4 hrs. 1-1/2 inches BEAMS: Roof / Ceiling (restrained & unrestrained) FIRE TEST: ASTM E-119 W8 x 28 S-301 1 hr. 1 inch S-301 1-1/2 hrs. 1 inch S-301 2 hrs. 1-1/2 inches BEAMS: Floor / Ceiling (restrained & unrestrained) FIRE TEST: ASTM E-119 W8 x 28 N-307 1 hr. 1 inch Restrained N-307 1-1/2 hrs. 1 inch N-307 2 hrs. 1 inch N-307 3 hrs. 1-5/8 inches W8 x 28 N-307 1 hr. 1 inch Unrestrained N-307 1-1/2 hrs. 1 inch N-307 2 hrs. 1-5/8 inches BEAMS: Unprotected Roof / Ceiling (restrained & unrestrained) FIRE TEST: ASTM E-119 W8 x 28 P-930 1 hr. 1 inch P-930 1-1/2 hrs. 1 inch P-930 2 hrs. 1 inch

BEAMS: Protected Roof / Ceiling (restrained & unrestrained) FIRE TEST: ASTM E-119 W8 x 28 P-302 1 hr. 1 inch ASSEMBLY: Floor / Ceiling (restrained) FIRE TEST: ASTM E-119 W8 x 28 D-929 1 hr. 1 inch D-929 1-1/2 hrs. 1 inch D-929 2 hrs. 1 inch D-929 3 hrs. 1-5/8 inches ASSEMBLY: Floor / Ceiling (unrestrained) FIRE TEST: ASTM E-119 W8 x 28 D-929 1 hr. 1 inch D-929 1-1/2 hrs. 1 inch D-929 2 hrs. 1-5/8 inches ASSEMBLY: Protected Floor / Ceiling (restrained & unrestrained) FIRE TEST: ASTM E-119 W8 x 28 D-303 1 hr. 1 inch D-303 1-1/2 hr. 1 inch D-303 2 hrs. 1 inch D-303 3 hrs. 1-5/8 inches ASSEMBLY: Floor / Ceiling (restrained & unrestrained) FIRE TEST: ASTM E-119 W8 x 28 D-303 2 hrs. 1-5/8 inches ASSEMBLY: Floor / Ceiling (unrestrained) FIRE TEST: ASTM E-119 W8 x 28 G-301 3 hrs. 1 inch

ASSEMBLY: Floor / Ceiling (restrained & unrestrained) FIRE TEST: ASTM E-119 W8 x 28 J-301 1 hr. 1 inch J-301 1-1/2 hrs. 1 inch J-301 2 hrs. 1 inch J-301 3 hrs. 1-5/8 inches ASSEMBLY: Floor / Ceiling (unrestrained) FIRE TEST: ASTM E-119 W8 x 31 P-601 1-1/2 hrs. 1 inch

WARRANTY/GUARANTEE INFORMATION Limited warranty/limitation of liability: Information and recommendations provided by Albi are based upon extensive test data, laboratory experiments and years of field experience believed to be reliable. Statements made herein as to application and other properties will vary according to the nature and conditions of the surfaces to which the product is applied. Albi warrants that its products will meet the specifications that it sets for them. Albi's responsibility under this warranty will be limited solely to replacing the products which prove defective, provided that Buyer gives Albi prompt notice in writing of said defect and satisfactory proof thereof. Products may be returned to Albi only after written authorization has been obtained from Albi. The foregoing warranty is in lieu of all other warranties, whether oral, written, express, implied or statutory. IMPLIED WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE WILL NOT APPLY. Technical or other advice is furnished by us solely as an accommodation and shall not increase the scope of our responsibilities or liability. Albi's warranty obligations and Buyer's remedies hereunder are solely as stated herein. In no event will Albi be liable either for the labor and other associated costs incurred in replacing the product, including, but not limited to, its removal and application, or for other incidental or consequential damages. Applicator shall guarantee that its installation of material conforms to manufacturer's recommendations, and shall further guarantee his workmanship connected with the installation for a period of one year from the date of installation.