American Legion Park City Pool Glasgow Ky. REPAIR SPECIFICATIONS SECTION I

Similar documents
REQUEST FOR PROPOSAL WAYFINDING SIGN DESIGN AND FABRICATION FOR THE CITY OF SALIDA, COLORADO

SPECIFICATIONS Section Gable Walkway Covers

SECTION MISCELLANEOUS METALS

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

FYPON, LLC. February 2014


Northpointe Renovation EPN #1701 F/A Prroject #17027 September 8, 2017

SECTION SWIMMING POOLS STAINLESS, FULL TILE, OR TILE TRIM

BULWARK BOLLARDS M30 & M50

Model # 5803SM. 6/15/2018 Page 1 of 5

To view non-printing Editor's Notes that provide guidance for editing, click on MasterWorks/Single-File Formatting/Toggle/Editor's Notes.

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

SPECIFICATIONS Section Cantilevered Walkway Cover

ITEM 442 METALS FOR STRUCTURES

SECTION ORCHESTRA PIT FILLER

SUBSTITUTION REQUEST (After the Bidding/Negotiating Phase)

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

Model # 600H-D. 4/2/2012 Page 1 of 6

Model # 612H. 7/11/2016 Page 1 of 6

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

DIMENSIONAL LETTER SIGNAGE

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

SECTION ENTRANCE FLOOR GRILLES SPECIFICATIONS

SECTION Athletic Field Equipment (Formerly 11480) DETAILED SECTION SOCCER AND FIELD HOCKEY EQUIPMENT

UC Denver Guidelines and Design Standards SECTION STRUCTURAL METAL FRAMING

9B1101 Elite Referee Shelter. SECTION Benches 1.1 WORK INCLUDED

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

Addendum Number Two Page 1 of 2

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

Aluminum Component Pipe Railings

Model # 922-S4. 12/18/2013 Page 1 of 8

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

SECTION SPECIFICATIONS Adjustable Louvered Roof Pergola Awnings Patio Covers and Pergola Awnings Section (10530)

1.02 SYSTEM DESCRIPTION

Call for any further details including but not limited to material, temper, thickness, paint and design.

Model # 964-S6. 2/3/2015 Page 1 of 8

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION

Ultra Aluminum Fence, Rail & Gate Specifications

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

SECTION [ ] MANUFACTURED METAL BOLLARDS

SECTION STRUCTURE MOUNT RAILING SYSTEM

Model # 158-P4. 12/12/2013 Page 1 of 11

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

LOG COLLEGE MIDDLE SCHOOL

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Model # 91-S6. 6/19/2014 Page 1 of 5

A. Submit the following within 30 days of award of contract under provisions of Division 1 and according to the Conditions of the Contract:

Series B450 Guide Specification

1.02 SYSTEM DESCRIPTION

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

REQUEST FOR PROPOSALS (RFP) TO DESIGN AND INSTALL SPLASH PAD AT RIVERVIEW PARK (NORTH AUGUSTA, SC)

Model # 940SM-P8. Page 1 of 10

INSTALLATION MANUAL RECTANGULAR COLUMN

Model # BT238-U6. 9/30/2014 Page 1 of 12

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SDARNG Construct Break/Locker Room Brookings FMS#8, CFMO#FBR461653F

2/24/2015 Page 1 of 5

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

Section PANEL SIGNAGE

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

MODELS: 24 SM & 24 SMSS

SECTION MECHANICAL EQUIPMENT - GENERAL REQUIREMENTS

Model # 95-S8. Page 1 of 8

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY GROUND STORAGE. Section GROUND STORAGE TANK (GST) MODIFICATIONS, CLEANING AND DISINFECTION

MODELS: SM & SMSS

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

Model # 940S-P6-BB. 6/7/2017 Page 1 of 10

SYNTHETIC GRASS INDOOR SURFACE SPECIFICATIONS: K9GRASS LITE

Model # 940SM-V8. Page 1 of 10

DIVISION 5 METALS SECTION STRUCTURAL STEEL

SHERIDAN SEATING INC.


SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

Expansion Joint Covers (079513)

MCINTOSH COUNTY SCHOOLS TODD GRANT (K-5) SCHOOL DEMOLITION AND FINISHED SITE WORK

Bill of Quantity (BOQ)

SECTION METAL ROOF AND SOFFIT PANELS

University of Illinois at Chicago Exterior Signage Standard

ITEM 461 STRUCTURAL PLATE STRUCTURES. Galvanized steel plates shall conform to AASHTO M167 and aluminum plates shall conform to AASHTO M219.

Trex Commercial Products page Metal Railing

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Transcription:

American Legion Park City Pool Glasgow Ky. REPAIR SPECIFICATIONS SECTION I A. DESCRIPTION OF WORK INCLUDED PIPING UPDATE INCLUDED ITEMS: Shop fabricate custom perimeter cover plates. Shop fabricate inlet cover plates as needed. Travel and subsistence to project location. Cut and remove existing gutter rollout for access. Install new 4 PVC manifold within gutter full perimeter. Field fabricate manifold adapter to existing piping. Abandon and plate weld existing inlet fittings. Install cover plates with recessed fastener. Shop fabricate Bullnose sections per original stampings. Weld sections per drawings to extended skimming height (80 0 ) ADA COMPLIANCE INCLUDED ITEMS: Prepare submittal drawings as needed. Shop fabricate 3/16 aluminum baby pool ramp. Travel and subsistence to project location. Install ramp, weld water tight and blend for coatings application. Locate and core deck as needed. Furnish and install flush mount anchor. Furnish and install ADA Compliant lift (Removable). Train Staff on lift operation. Furnish letter of ADA Compliance. B. QUALITY ASSURANCE:

1. The renovation shall be a product of a Pool Contractor regularly engaged in the engineering, fabrication, and erection of swimming pool systems. The Pool Contractor shall provide evidence of at least Ten (10) projects of like magnitude and materials. 2. Any request for approval of a substitute must be in the form of a complete set of engineering drawings, structural calculations, and specifications, prepared specifically for this project by an Engineer registered in this state and be submitted to the Owner not less than ten (10) days prior to bid date. 3. The proposed substitute shall comply with all of the design, performance, and warranty requirements in this section. C. SHOP DRAWINGS: 1. Submit for Owner s approval a minimum set of drawings showing general layout and scope of all work, all sections and details for fabrication and installation, and all items requiring coordination with the work of other trades. 2. Submit in writing with Shop Drawings variations from contract drawings and/or Specifications. Variations so noted shall take precedence over Contract requirements upon Owner's approval of the Shop Drawings. D. POOL WARRANTY: 1. Pool Contractor shall provide a Five year warranty from date of start-up acceptance against defects in workmanship and material for the aluminum pool and piping. a. Warranty excludes damage due to fair wear and tear, deliberate abuse, mechanical damage, vandalism, and defects caused by uncontrolled external pressure. E. ABOVE WARRANTIES ARE EACH SUBJECT TO THE FOLLOWING CONDITIONS: 1. Warranties are effective upon receipt of full payment to the Pool Contractor for the total contract amount.

2. Liability is limited to repair in place of defects and does not cover damages due to loss of use, loss of profits, or consequential damages. 3. Pool Contractor must approve any modifications or additions by others to the original pool after renovation. 4. Written notice of defect must be delivered to Pool Contractor within fifteen (15) days of the date defect is discovered. F. GENERAL 1. Pool renovation specified herein, as performed, utilizing materials and procedures outlined below which shall be the basis for technical quality for any other manufacturers requesting consideration of their pool renovation. Refer to Item B, 1-3 above. G. ALUMINUM ALLOYS UTILIZED FOR POOL SYSTEM: 1. Sheet and Plate: 5052-H32 or equivalent 2. Castings: 319-F 3. Extrusions: 6061-T6 4. Piping: Schedule 80 PVC I. POOL COATINGS: 1. Materials shall be high grade specifically designed for preparing and coating aluminum swimming pool. (See attached procedure) 2. Coating shall be white with black markings.

SECTION II RENOVATION SPECIFICATIONS RELATED WORK DESCRIPTION DESCRIPTION The following items of work, which are associated with the swimming pool systems are not the Pool Contractor's responsibility, and are to be provided by other Contractors or by the Owner in accordance with the Specifications outlined herein and details and notations on the Pool Drawings. A. CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS: 1. Provide temporary water at 50 psi minimum pressure for cleaning, rinsing, and testing purposes, and facilities for draining pool. 2. Re-paint areas in pool disturbed by fabrication 3. Provide access to site for Pool Contractor's prefabricated materials. B. PROTECTION: 1. Protect pool immediately after renovation thereof and until startup acceptance, from damage, contamination, spatter, or spillage caused by construction work of other trades. This shall include covering pool with protective materials when necessary and responsibility for prompt repair or corrective measures in the event of damage. C. EXCAVATION AND CONCRETE WORK: 1. Provide all concrete removal, excavation and back-fill removal for pool to filter piping replacement. Work includes any shoring needed to provide a safe environment. Areas of excavation will be delineated by the Pool Contractor.

3. Provide replacement concrete sections as needed per original installation. D. CLOSEOUT: 1. Provide representative at time of start-up to coordinate any final work related to the pool system.