Impact of Culture Media on Biological Indicator Spore Recovery

Similar documents
POPULATION ASSAY KIT INSTRUCTIONS FOR USE 10 EVERGREEN DRIVE, SUITE E BOZEMAN, MT 59715

TECHNICAL DATASHEET. in compliance with: USP, ISO and all appropriate subsections FQ 106 v3.0 August, 2015

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

DUAL SPECIES BIOLOGICAL INDICATOR SPORE STRIPS For Monitoring Ethylene Oxide (EO), Steam and Chemiclave Processes

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

2018 North America Lab Services Fee Schedule

Today s Topics. General Quality Control Best Practices. Practices Antimicrobial Effectiveness Testing(AET) Best Practices Environmental Isolates

Growth Promotion Test Guide for Media Used in Sterility Tests

Biological Indicator Reduced Incubation Time (RIT) Presented by: Andrew Melloy

Population Catalog Number. Log Log Log Combined (both B. atrophaeus and G. stearothermophilus)

Finding the Worst Case Location in Your Sterilization Load Just Got Easier

SterilAmp II Geobacillus stearothermophilus

MICROBIOLOGICAL CULTURE MEDIA

Cleaning Efficiency of The MicroOne Wipe and Mop Cleaning System

Secure. Tested. Certified.

Method Suitability Report Membrane Filtration Sterility Test with QTMicro Apparatus

( 주 ) 세현테크 TEL : FAX :

The Most Probable Number Method and Its Use in QC Microbiology

REUSABLE MEDICAL DEVICE VALIDATION

Biological Indicators

Verification Testing of Biological Indicators for Moist Heat Sterilization

MICROBIOLOGICAL VALIDATION PROGRAMME FOR SRCL CLINICAL WASTE TREATMENT AUTOCLAVE PROCESSING METALS (SINGLE USE DEVICES) AT LEEDS

NEIlON LABORATORY FINAL REPORT TIME KILL STUDY PROCEDURE NO. STP0158 REV 01 PROTOCOL DETAIL SHEET NO REV 01

Effective Heat Sterilization in CO 2 Incubators

Written By Dr. Robert Ramaley (Univ. NE Med CTR), Mia Ware, Dan Pearson, and Christopher R. Dwyer* (Raven Biological Laboratories)

HardyVal TM CSP RANDOM TEST KIT

Lab 2-Microbial Enumeration

The Most Probable Number Method and Its Use in QC Microbiology

Compounding Pharmacies and the USP <71> Sterility Tests

á61ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: MICROBIAL ENUMERATION TESTS

Validation and Control of Porous Load Sterilisation

Study Summary. Results: All tested media-filled vials were negative for growth of any microorganisms.

PRODUCT D-VALUE STUDIES: A CRITICAL TOOL WHEN DEVELOPING A STERILIZATION PROCESS

CATALOG BIOLOGICAL AND CHEMICAL INDICATORS

INSTRUCTIONS FOR USE

Recent USP Updates May, 2013

A MICROBIAL RESISTANCE EVALUATION OF INDOOR MATERIALS AIR KRETE INSULATION SAMPLE. prepared for AIR KRETE

USP <1116> and Contamination

Hygiene Monitoring. Biological Indicators for Monitoring Sterilization Processes. Product Information. BI_07_en

Microbiology Testing: USP requirements for Sterile and Nonsterile Preparations Webinar Q&A

Exercise 13 DETERMINATION OF MICROBIAL NUMBERS

Secure. Tested. Certified.

Medline Gemini Sterilization Wrap. Test Studies

TRYPTIC SOY AGAR (TSA) WITH LECITHIN AND TWEEN 80

NO 2 Gas Sterilization and Decontamination: Keeping Pace, from Start to Finish

Effect of Environmental Conditions During Heating on Commercial Spore Strip Performancet

Test Organisms: Staphylococcus aureus (ATCC 6538) Escherichia coli (ATCC 11229) Pseudomonas aeruginosa (15442)

Sterilisation Monitoring Products

ISO INTERNATIONAL STANDARD

The Parenteral Drug Association

Biocidal Surface Test - Clinell Wipes ~ Project Report Prepared for GAMA Healthcare Ltd ~ Huddersfield Microbiology Services Oct 06

GUIDE TO INSPECTIONS OF MICROBIOLOGICAL PHARMACEUTICAL QUALITY CONTROL LABORATORIES

Coliform bacteria are quantitated by the fractional gram pour plate technique (Note 1). Test tubes containing gas collector tubes (Durham Tubes)

Measuring Sterilizing Values In Containers of Food Using Thermocouples and Biological Indicator Units 1,2

[PPT PDF] Pharmaceutical Water System Design Validation - Microbial Testing of Water is discussed in detail in this article.

Decontamination Effectiveness of Esco Celsafe CO2 Incubator Sterilization Feature using High Heat Temperature By Bekti Tri Sumaryati

ISO INTERNATIONAL STANDARD

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

Innovative. Smart. Trusted.

ISO INTERNATIONAL STANDARD. Meat and meat products Enumeration of presumptive Pseudomonas spp.

European Pharmacopoeia

Submitted May 16, May 23, 2014 BY:


21.4 Recombinant DNA technology Calculation worksheet. AQA Biology. Calculating the efficiency of DNA transfer during genetic engineering

This compilation of the complex

Innovative H 2 O 2 V-Phase biodecontamination solutions

Chemical Indicators. Biological Indicators. Physical Monitors. Welcome! How do I get a CE Certificate? Learning Objectives

Biological Indicators and Their Application in Clinical Sterilization Spores Don t Lie 1

Soleris system evaluation of testing applications for UHT/aseptic packs

Moist Heat Terminal Sterilization for Controlled Release Materials

KILL-TIME STUDIES Antimicrobial Activity of Experimental Solutions Using Legionella pneumophila Test Solution: ACS 200 Submitted June 6, 2012

3 Petrifilm Environmental Listeria Plate for the Rapid Enumeration of Listeria from Environmental Surfaces

Raad voor Accreditatie (Dutch Accreditation Council RvA) Explanatory document on microbiology

SECONDARY COLONY FORMATION BY BACILLUS SUBTILIS ON EOSINE

Product Catalogue. for gke Steri-Record Biological Indicators, Process Challenge Devices and Accessories

sterilisation monitoring products

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

This document is a preview generated by EVS

LexaMed Curriculum Vitae

Biological Consulting Services of North Florida, Inc.

Consistent. Reliable. Innovative.

INTRODUCTION water-soluble Figure 1.

USP <1223> Revision and the Alternative Microbiological Methods Workshop Tony Cundell, Ph. D. Consulting Microbiologist, Scarsdale, New York, USA

QUANTIDISC AND YEA METHOD COMPARISON

USP Chapter 823 USP 32 (old) vs. USP 35 (new)

Submitted May 16, May 23, 2014 BY:

KILL-TIME STUDIES Antimicrobial Activity of EO H 2 O Using Clostridium difficile spores Test Solutions: Acidic H 2 O Submitted December 12, 2011

Milliflex Quantum Detection of microbial contaminants in water samples

D08-FSQ(2005)D/ Name of Additive: Calsporin. Active Agent(s): Bacillus subtilis C Renata Leuschner (CRL-FAA)

Large Volume Serial Dilutions:

BIO & PHARMA ANALYTICAL TECHNIQUES

Instructions for Validation of Autoclaves

Biological Monitoring

ISO INTERNATIONAL STANDARD

Validation Guide Sterisart NF

Validation Guide Sterisart NF

Comparison Study between IDF Disk Assay and Delvotest SP-NT

INSTRUCTIONS FOR USE

Effect of Storage Conditions upon the Resistance (D-value) of Spore Strip Biological Indicators (BIs) used in EtO Sterilization Monitoring

PRODUCT CATALOGUE. for gke Steri-Record Biological Indicators, Process Challenge Devices and Accessories

Transcription:

Volume 4, Number 1 January 2007 Impact of Culture Media on Biological Indicator Spore Recovery Kellie Matzinger Spore Lab Supervisor The D-value of a specific biological indicator is significantly influenced by the spores, but also by carrier materials, product configuration, and recovery culture medium. Spores don t have an intrinsic D-value. Spores must be placed in or on a carrier to be tested. They need to be provided with nutrients for recovery and growth after testing. All these elements affect the measured result. Therefore, the D-value test is a measurement of the performance of the Biological Indicator system. The recovery medium significantly influences measured recovery. The USP (1) specifies Soybean Casein Digest (SCD) media in agar and broth forms. Variations in population recovery as well as resistance performance occur with different manufactured lots of the same media formulation from the same manufacturer. Soybeans are a natural product, therefore, the source of the soybeans as well as the particular growing season conditions all influence the nutritional quality of the soybeans. This nutritional quality has a direct impact on the ability to recover spores (2). Graham and Boris (3) described how different lots of media affected measured biological indicator performance. Pflug (4,5) also reported the effect of culture medium on the recovery of spores. Shintani and Akers (6) also observed the variance. Sasaki et al (7) also confirmed that calcium concentrations in the media varied greatly among media manufacturers. Shintani et al (8) further documented a correlation between increased calcium concentration in SCD media and an increased ability to recover injured G. stearothermophilus spores. Shintani is quoted if you don t have the same medium used by the BI manufacturer to certify the product, you will not be able to reproduce the certified data. Figure 1 illustrates the difference of D-values between lot to lot and manufacturer to manufacturer using SCD media. Data collected by Shintani et al (8).

D-value 3 2.8 2.6 2.4 2.2 2 1.8 1.6 1.4 1.2 1 A B C D E F SCD Manufacturer Lot 1 Lot 2 Lot 3 Figure 1. Three lots of SCD were tested from each of six different manufacturers. ISO 11138:1994 (9) states that the D-value of a BI must be reproducible to within 0.5 minutes of the certified value. The above data indicate major differences between the highest and lowest recovery and between different lots of SCD from different manufacturers. The data in Figure 1 clearly shows that different manufacturers of SCD yield different performance data. The ISO requirement could be met if media used was from the same SCD manufacturer. Each manufacturer of SCD media demonstrated variances that were within the ISO D-value limit. Figures 2 and 3 illustrate the differences SGM observed with spore population recovery of G. stearothermophilus and B. atrophaeus using three lots of SCD media purchased from the same manufacturer.

CFU / Plate 130 120 110 100 90 80 70 60 50 40 30 20 Lot A (Gst) Lot B (Gst) Lot C (Gst) Figure 2. G. stearothermophilus (Gst) recovery with three (3) different manufactured lots of SCD media CFU / Plate 130 120 110 100 90 80 70 60 50 40 30 20 Lot A (Batr) Lot B (Batr) Lot C (Batr) Figure 3. B. atrophaeus (Batr) recovery with three (3) different manufactured lots of SCD media In Table 1 Lots A, B and C were all consistent in spore recovery of G. stearothermophilus. Lots A and B provided similar spore recovery for B. atrophaeus, but Lot C gave a much lower spore recovery of B. atrophaeus.

Table 1. Summary of the recovered colony forming units () for the three lots of media tested. Lot A (Gst) 2 Lot B (Gst) Lot C (Gst) Lot A (Batr) 1 Lot B (Batr) Lot C (Batr) Number of 20 20 20 20 20 20 Samples Minimum 57 53 59 103 102 67 Maximum 84 83 76 122 127 82 Mean 68.35 69.55 65.0 110.7 115.4 74.35 Std. Deviation 7.788 8.835 4.389 5.516 6.816 4.440 1 Batr: B. atrophaeus 2 Gst: G. stearothermophilus USP specifies SCD medium as a general guidance, but it is only the beginning of the manufacturer s medium controls. SGM controls these media differences by offering a number of self-contained BIs (EZTest, MagnaAmp, and SterilAmp ), which provide exactly the same spore recovery medium as that used for performance data. SGM also offers Releasat culture sets for EO, which includes the same tubed media used for the performance data of the SGMStrips. SGM has recently introduced a Population Assay Kit. This kit includes a bottle of sterile culture media and all the supplies to duplicate the spore population assay. This product provides our customers with the same culture medium used by SGM when performing spore population determination. Differences in the nutritional quality of culture media significantly influence not only the spore population recovered, but also the measured performance of the spores. This difference is impossible to predict or detect. It only becomes apparent when experimental data indicates a result that was different than expected. It is not easy to explain the aberrant results. SGM is making available to our customers the same media used in our testing. Our goal is to have it available for all products in the near future. Please email us with topics you would like to see addressed in Spore News.

1 United States Pharmacopeia (USP) 28, 2005, Mack Publishing Co., Easton, Pa. 2 Davis, S.B.; Carls, R.A.; Gillis, J.R. Recovery of Sublethal Sterilization Damaged Bacillus Spores in Various Culture Media. In Developments in Industrial Microbiology, 1979, 20, 427-438, Underkofler, L.A., and Wulf, M.L., Eds. Society for Industrial Microbiology, Arlington, VA. 1979. 3 Graham G.S. and C.S. Boris, Chemical and Biological Indicators, in Sterilization technology: A practical guide for manufacturers and users of health care products, Morrissey R.F. and B.Y. Phillips (eds), New York, Van Nostrand Reinhold, pp. 36-69 (1993). 4 Pflug I.J., Smith G.M., Christensen R., Effect of Soybean Casein Digest Agar on Number of Bacillus stearothermophilus Spores Recovered, Applied and Environmental Microbiology, August [42] pp. 226-30 (1981). 5 Pflug I.J. Microbiology and Engineering of Sterilization Processes, in Environmental Sterilization Services, Tenth Edition, Minneapolis, Chapter 8, p. 8.1 (1999). 6 Shintani H. and J.E. Akers, On the Cause of Performance Variation of Biological Indicator Used for Sterility Assurance, PDA Journal of Pharmaceutical Science and Technology, Vol. 54, No. 4, July- August, (2000). 7 Sasaki K, H. Shintani, J. Itoh, T. Kamogawa, Kajihara, Effect of Calcium in Assay Medium on D-value of Bacillus stearothermophilus ATCC 7953 Spores, Applied and Environmental Microbiology, December, 66[12], 2000. 8 H. Shintani and K. Sasaki, On the Difference in Attaining Sterility Assurance Between Lots and /or Manufacturers of Soybean Casein Digest Culture Medium, J.Antibact. Antifun. Agents, 27, 145-151 (1999) 9 International Organization for Standardization, Sterilization of Healthcare Products: Biological Indicators, ISO 11138:1994 (ISO, Geneva, 1994)