TECH TALK Sponsored by

Similar documents
TECH TALK Sponsored by

TECH TALK Tile and stone lippage: Achieving acceptable tile lippage through quality tile and stone installations

Shrinkage leads to indent fractures in stone

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

The next three paragraphs describe Chloraloy used as waterproofing for floors and walls at showers, tub surrounds, and other wet areas.

Triton WP Waterproof Membrane

Donato V. Pompo CTC CMR CSI CDT MBA P.O. Box 965 Jamul, CA (O) (F) CURRICULUM VITAE

Donato V. Pompo CTC CMR CSI CDT MBA P.O. Box 965 Jamul, CA (O) ( ) CURRICULUM VITAE

Donato V. Pompo CTC CMR CSI CDT MBA P.O. Box 965 Jamul, CA (O) ( ) CURRICULUM VITAE

Donato V. Pompo CTC CMR CSI CDT MBA P.O. Box 965 Jamul, CA (O) (F) CURRICULUM VITAE

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

OPEN SET SYSTEM. Easy-to-install Waterproofi ng Shower System. Installation guide

Underlayment Systems

Single Source Comprehensive Warranty. ARDEX Americas. Swimming Pool Guide

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

Triton DCI Decoupling Mat

RedGard Crack Prevention and Waterproofing Membrane

RedGard Waterproofing and Crack Prevention Membrane

FirstEnergy Program Overview

Foundations. Issue. Slab-On-Grade Liquid Water Control (See Figure 2-2) Goals. Guidance

Weatherproofing Masonry For Northern Climates

WPM WATERPROOFING MEMBRANE

SECTION TILING

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

CONCRETE TILE PAVERS

Wet Areas. An excerpt from the Dimension Stone Design Manual, Version VIII (May 2016)

May 2, 2018, Bethany, Conn. -- LATICRETE, a leading manufacturer of globally proven construction solutions for

When I started tiling, we didn t do our own shower pans that BATHS

Groundwater Seepage. Causes of Basement Seepage and Leaks Hydrostatic Pressure

Dural Durabase WP Installation Instructions For showers and general waterproofing (800)

SECTION DECORATIVE STAINLESS STEEL DRAINS AND GRATES

FORENSIC TILE CONSULTANTS

Triton BK Backer Board & Tile Underlayment

EXTERIOR ROOF / DECK FLOORS Roof Deck or Balcony over Occupied Space, Drainage Mat, Mortar Bed Ceramic Tile

PROTECTO DECK INSTALLATION INSTRUCTIONS

SECTION ROOF PEDESTAL PAVER SYSTEM

Copyright Ceramic Tile And Stone Consultants, Inc. All rights reserved.

Assembly Instruction. wedi Fundo Primo Steam Shower System

Schluter -DITRA-DRAIN

Commercial Roof Cover Maintenance and Repair Risk Engineering Your Business Insurance Specialists

Henri Fennell, CSI/CDT ABX 2015

SECTION GYPSUM BOARD ASSEMBLIES

Figure 2. By John H. Koester

CONCRETE STAIRS Note:

Recognizing and Addressing Moisture Concerns by Mike Endredi

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Chapter 2 Understanding The Problem

ASTM D7877 Standard Guide for Electronic Methods for Detecting and Locating Leaks in Waterproof Membranes

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

A. Submit product data sheets and literature verifying fire ratings and physical properties of materials.

Mapeguard UM. Underlayment membrane for ceramic and stone tile

Caulks & Sealants. Professional. Catalog

WALL TILE CHARACTERISTICS

SECTION CERAMIC and QUARRY TILE

CTIOA Field Report

CertainTeed. GlasRoc. Tile Backer

BUILDING EXTERIOR SHELL TRAINING

AFM Anti-Fracture Membrane & AFM-WM Anti-Fracture Waterproofing Membrane Three-Part Specifications

Design Tips Technical Bulletin #47

Metal Retrofit Systems from Royalty Roofing

WALL TILE CHARACTERISTICS

Design Tips Technical Bulletin #47

A. Submit product data sheets and literature verifying physical properties of materials.

Donato V. Pompo CTC CMR CSI CDT MBA P.O. Box 965 Jamul, CA (O) (F) CURRICULUM VITAE

1 PVC or ABS drain with strainer

STEAM SHOWER / ROOM; WOOD OR METAL STUDS Wood or Metal Studs Cement Backer Board Walls, Mortar Bed Floor Ceramic Tile

Water Management & Damage Prevention: A Guide for Homeowners

SECTION CERAMIC TILE. B. Ceramic tile wall finishes including standard and custom designs.

WALL TILE CHARACTERISTICS. DUNES GLASS TILE

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

DESIGN TIPS TECHNICAL BULLETIN #47 FLASHING, WEEP HOLES AND RELATED ANCHORAGE [1 of 8]

Commercial Air Barrier Systems

Installation of Large Format Tile & Stone

EXTERIOR ROOF / DECK FLOORS Roof Deck, Drainage Layer, Mortar Bed Stone Tile

Schluter -DITRA Installation Handbook The Universal Underlayment for Ceramic and Stone Tile

SITE AND BUILDING INSPECTION CHECKLIST

ZA3 Shower drain Standard Installatibn. install location& Notes: Linear Shower Drain. by stainless steel. More 20 grate desige

SECTION TILING

8245 Remmet Ave Canoga Park, CA (888) Installation Instructions - AVM System 700 Under Tile Waterproofing and Anti-Fracture Membrane

Tile on Existing. Viewpoint

Uncoupling Membranes for Tile Installations. Technical White Paper UNCOUPLING MEMBRANES

CertainTeed. Tile Backer

AVM System 500. Aussie Membrane 500

AVM System 500. Aussie Membrane 500

2019 IAQA Annual Meeting

CertainTeed. Tile Backer

***************************************************************************************************************

SHOWER RECEPTORS Solid Backing, Bonded Waterproof Membrane Intergraded Bonding Flange Ceramic Tile

PRODUCT GUIDE SPECIFICATION

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Eradicating ice dams begins below the roof deck. by Maciek Rupar

CTIOA REPORT

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

Mapelastic 400. Professional, Liquid-Rubber Waterproofing and Crack- Isolation Membrane DESCRIPTION WHERE TO USE FEATURES AND BENEFITS

LATICRETE HYDROBAN Waterproof Membrane

SECTION G RELIEF VENTS A-0

SECTION CONCRETE PAVING SLABS SET IN MORTAR

Schluter -Shower System Installation Handbook Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds

Transcription:

TECH TALK Sponsored by Installing ceramic tile, glass tile and stone in interior wet areas Slope, weeps, and flashing are key to managing water and avoiding failures By Donato Pompo, CTC, CSI, CDT, MBA, Ceramic Tile and Stone Consultants (CTaSC), University of Ceramic Tile and Stone (UofCTS). Exterior decks and balconies, and interior showers and bathrooms have historically been problematic areas for the installation of ceramic tile, glass tile, stone tile and other stone products. Typically problems are due to installer error, such as not using appropriate materials for those applications, or not having clear enough specifications. In each case it is the result of not following industry standards. Exploration into the intricacies of exterior decks and balconies can be an entire article in itself, but for this story, we will focus on interior showers and bathrooms. Industry standards are created by industry consensus groups consisting of installers, producers, and industry experts through organizations such as ANSI (American National Standards Institute), TCNA (Tile Council of North America), ASTM (America Society for Testing and Materials) or ICC (International Code Council). These consensus group members combine their many years of experience with science to establish standards so problems and failures can be avoided and not repeated. Thus if standards are not followed then known potential problems can t be avoided. As a forensic investigator for over 11 years, I have investigated many failed interior showers and bathrooms. I have found that the common denominators to tile and stone failures in these applications were the lack of proper slope, plugged weep holes, and inadequate flashing to contain or manage the water that resulted in various types of damages. 64 TileLetter January 2014

Slope, weeps, and flashing are key to managing water and avoiding failures like leaks, mold and substructure deterioration. Managing water volume First, consider the volume of water that showers are subjected to on a daily basis. Since these areas are likely to be subjected to more water than a typical roof is subjected to annually, it is imperative that extra care and attention are spent on specifying and constructing them. This is accomplished by properly managing the water so it is controlled and safely evacuated from those areas. Lack of adequate slope is a common problem in interior wet horizontal applications such as shower floors, shelves and seats. It is very clear in the tile and stone industry standards, as well as in the Uniform Plumbing Code (UPC), and in the IRC (International Residential Code) or IBC (International Building Code) building codes, that the slope to drain, or away from the building, should be a minimum 2% slope. That calculates to 1/4 per foot (6 mm per 305 mm). UPC says the slope to drain in a shower must be a minimum of 1/4 per foot (6 mm per 305 mm), but not more than 1/2 per foot (13 mm per 305 mm). Not only is it important for that slope to drain to be at the surface of the tile or stone, but it is critical that the minimum 1/4 per foot (6 mm per 305 mm) slope to drain is at the surface of the waterproof membrane or drain plane. Drains come in two sections. Where the drain clamps down on the waterproof membrane below the surface 66 TileLetter January 2014

TECH TALK of the tile assembly, there are weep holes in the drain assembly, so that any water that migrates to the waterproof membrane can then evacuate into the drain through the weep holes. Problem #1: Improper slope to the drain There are three common problems that we run into. First, the waterproof membrane is not properly sloped to the drain. In a shower this can result in the tile mortar bed staying constantly damp, which creates a musky odor in the room, or it may cause a stone or tile floor to look wet. Excessive moisture might result in the stone spalling (deteriorating) and/or staining. Sometimes we find that the waterproof membrane is flat or even negatively sloped away from the drain, or that there are low spots on the membrane surface where water collects. TEC HydraFlex Waterproofing Crack Isolation Membrane provides a watertight surface over walls, floors and ceilings, and isolates in-plane cracks up to 1/4. Ideal for showers, pools and exterior applications, the mold- and mildew-resistant formula is easy to apply by roller, trowel or spray. HydraFlex can be applied over new concrete cured a minimum of three days. Its fast-drying formula is ready for tile installation in as few as two hours. HydraFlex Waterproofing Crack Isolation Membrane exceeds ANSI A118.10 specifications for waterproofing membranes, and ANSI A118.12 specifications for crack-isolation membranes. It contains low VOCs and is available in onegallon and five-gallon pails. www.tecpecialty.com. An improperly-sloped or level membrane can result in tile mortar bed staying constantly damp, creating a musky odor, causing a stone or tile floor to look wet, or deteriorating the stone (spalling). TileLetter January 2014 67

Problem #2: Plugged weep holes The second common problem is drains with plugged weep holes. Industry standards state that the weep holes are to be covered with pea gravel or with a plastic weep hole protector to make sure the weep holes stay open. Often this weep hole protection is left out, and mortar is placed over the weep holes, plugging them. Thus, if the waterproof membrane is properly sloped to drain, the water cannot escape into the drain. Again, this can result in the tile mortar bed staying constantly damp, which results in the musky odor in the room, a wet-looking floor or stone spalling or staining. The term spalling refers to the deterioration of the surface of a stone. It is the symptom of a stone being subjected to excessive moisture over time. Spalling is typically caused by moisture migrating from the stone s underlying substrate up through the stone to its surface where the moisture evaporates. As the moisture travels from under the stone through the cementitious materials, and through the stone itself, the moisture picks up various minerals (salts) which dissolve in the moisture. When the moisture reaches the surface of the stone it evaporates and the minerals precipitate into a solid again. This expansion or crystallization of the mineral, referred to as efflorescence, causes the surface of stones to deteriorate to some degree. Whether it is a shower or an exterior deck or balcony, the waterproof membrane surface must be sloped to drain or away from the building. Shower pans or receptors are supposed to have a pre-sloped mortar bed installed over the base substrate before installing the waterproof membrane. The pre-slope needs to have a minimum slope of 1/4 per foot (6 mm per 305 mm). Industry standards state that the weep holes are to be covered with pea gravel or with a plastic weep hole protector to make sure the weep holes stay open. Problem #3: Membrane breaches That brings up the third common problem that we find in showers: waterproofing or vapor retarders that are not complete or continuous. They tend to lack flashing at transition areas. Considering the potential collateral damages a defective balcony can develop, it is important to construct it like a big shower pan. Assuming that the deck has been properly pre-sloped, the waterproof membrane must continue, or be 68 TileLetter January 2014

flashed, up the wall at least 3" (76 mm) above any thresholds to prevent water from causing any potential collateral damages. All seams, penetrations and transitions must be properly waterproofed, flashed and sealed with a sealant. These are the areas that are most vulnerable to having problems, so they need to be given the extra attention to ensure they are installed correctly. The waterproof membrane should never be penetrated, unless it is unavoidable, and then the penetration has to be properly flashed and sealed with the appropriate sealants to ensure it will never leak. All seams, penetrations and transitions must be properly waterproofed, flashed and sealed with a sealant. Seams, penetrations and transitions are the areas most vulnerable to problems, so special attention must be given to be sure they are sealed and flashed properly. The waterproof membrane should never be penetrated, unless it is unavoidable, and then the penetration has to be properly flashed and sealed with the appropriate sealants to ensure it will never leak. Often we find that decks are sloped to their outer edge without any type of gutter or drain. The water drains over the side of the balcony and eventually results in staining along the siding, or staining and spalling the stone if there is stone siding. The latest trend is to use trench or linear drains that work very well and can be installed at the perimeters of decks or showers. So how can a tile installer make sure that showers are given the attention they need to avoid failures? It is the same old answer. Follow industry standards and man- 70 TileLetter January 2014

ufacturers directions. It doesn t matter who is at fault when there is a problem; everyone ends up paying either in time to defend themselves, money to fix the problem or with their reputation. So it is in everyone s best interest to make sure that tile and stone installations are done properly. (Editor note: please visit www.tileletter.com for the full text of this story, which also addresses exterior installations). Ceramic Tile Consultant, Donato Pompo, CTC, CSI, CDT, MBA, is the founder of Ceramic Tile and Stone Consultants (CTaSC), and of the University of Ceramic Tile and Stone (UofCTS). Donato has over 35 years of varied experience in the ceramic tile and stone industry. CTaSC provides services in Forensic Investigations, Quality Control Services for products and installation methods to include writing specifications, training programs, testing, and on-site quality control inspection services. CTaSC is a professional consulting business comprised of accomplished ceramic tile consultants, stone consultants, ceramic tile and stone installers, architects, engineers, general contractors, construction scientists and other industry specialists and experts conveniently located throughout the US and Canada. You can reach Donato by visiting the company website at www.ctasc. com, emailing Donato@CTaSC.com or calling 866-669-1550. Earn More Jobs, Earn More Money and Avoid Problems Get Your Installers ITS Verified! The Tile Installer Thin-Set Standards (ITS) Verification Certificate is awarded by the University of Ceramic Tile and Stone (UofCTS) and endorsed by tile and floor covering associations in North America. Tile installers who successfully complete this online course that teaches industry standards and methods for adhered thin-set applications will earn the ITS Certificate. The ITS Certificate will give you credibility with your customers and will enable you to earn more jobs, make more money and avoid costly failures. Course material teaches industry standards for thin-set installation applications, including how to inspect and prepare substrates, thin-set methods and workmanship requirements. The ITS online course is available in English and in Spanish. Only $ 150 per tuition Volume discounts available. Membership discounts available through CTDA, TTMAC and WFCA. 24/7 Internet Access No Travel Expenses No Lost Productivity Certificate Issued Additional online tile and stone courses are available from our website: Understanding the Basics of Ceramic Tile and Understanding the Basics of Natural Stone UofCTS s training courses are ideal for installers, architects, salespeople, designers or anyone interested in tile and stone. info@uofcts.org www.uofcts.org (866) 669-1550 72 TileLetter January 2014