TOXICITY, EFFICACY, STABILITY AND CORROSION TEST RESULTS

Similar documents
ENVIROCIDE. Technical Bulletin

HIGH-LEVEL DISINFECTANT RAPICIDE. Safety, Efficacy, and Microbiological Considerations

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

HIGH-LEVEL DISINFECTANT AND STERILANT

STUDY REPORT STUDY TITLE. Evaluation of Antimicrobial Activity of a Cold Plasma Generator. Virus: Feline Calicivirus PRODUCT IDENTITY

Safety, Efficacy, and Microbiological Considerations. * For use with RAPICIDE PA outside of the USA, Canada and Australia

The New Choice in Disinfection Technology

Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer

ASSESSMENT OF THE MICROBICIDAL ACTIVITY OF AN ACCELERATED HYDROGEN PEROXIDE- BASED FORMULATION (AHP-5) AGAINST VRE AND MRSA

ONAMER M. PRESERVATIVE and ANTIMICROBIAL ONAMER

Dealer Bulletin. Re: OPTIM 33TB; 3 Minute Fungicidal Claim. OPTIM 33TB Contact Times* To: All Authorized SciCan Dealers Canada

High-Level Disinfectant and Sterilant. Rapicide SAFETY, EFFICACY AND MICROBIOLOGICAL CONSIDERATIONS

Study Title Determination of the Antiviral Effectiveness of KHG FiteBac Technology Test Substance Delivered via Pipette Against MS2 Bacteriophage

Evaluation methods of disinfectants. Kwandong Univ. Coll. Med. Hyukmin Lee

Rapicide High-Level Disinfectant and Sterilant. Safety, Efficacy, and Microbiological Considerations

Test Organisms: Staphylococcus aureus (ATCC 6538) Escherichia coli (ATCC 11229) Pseudomonas aeruginosa (15442)

Appendix 2. Revised 510(k) Summary

Test Method of Specified Requirements of Antibacterial Textiles for Medical Use FTTS-FA-002

Biological Consulting Services of North Florida, Inc.

STERI-7 XTRA Concentrate Technical Information

Microsol4. General Purpose Decontaminant Effective Against DNA/RNA Contamination

KILL TIME STUDIES Antimicrobial Activity of Advanced Cellular Silver (ACS) 200 Using Methicillin resistant Staphylococcus aureus (MRSA)

8,000 facilities count on it

á61ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: MICROBIAL ENUMERATION TESTS

MAR COR RESEARCH REPORT. Fast, Safe, Reliable Surface Disinfection for the Life Sciences Market. Competent, Consistent, & Compliant

Submitted May 16, May 23, 2014 BY:

DISINFECTION QUALIFI CATION TESTING CONSIDERATIONS FOR THE ASEPTIC AND CLEANROOM MANUFACTURING ENVIRONMENT

KILL-TIME STUDIES Antimicrobial Activity of Experimental Solutions Using Legionella pneumophila Test Solution: ACS 200 Submitted June 6, 2012

Disinfectant Qualification A Multifaceted Study

RETHINK HOW YOU CLEAN REPLACE TRADITIONAL CAUSTIC CHEMICALS IMPROVE EMPLOYEE SAFETY & PRODUCTIVITY SAVE TIME & MONEY IMPROVE SUSTAINABILITY

Ready-To-Use Cleaning and Disinfecting Fluid for Endoscopes & Medical Instruments Technical Information

Current Industry Trends -Including Cleaning and Disinfection trends, Disinfectant Validation Trends, and Current Warning Letter Activity.

Accugen Laboratories, Inc.

Virusolve + EDS. Concentrated Sporicidal High Level Disinfecting Fluid for Endoscopes & Medical Instruments Technical Information

Submitted May 16, May 23, 2014 BY:

TECHNICAL DATASHEET. in compliance with: USP, ISO and all appropriate subsections FQ 106 v3.0 August, 2015

3.3.1 Microbial enumeration tests

TEST REPORT : CHM15-LY-02

Laboratory Testing of Zebra s Z-Band Direct Thermal Wristbands with Antimicrobial Coating

The AOAC Germicidal Spray Products as Disinfectants

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

Document No. FTTS-FA-001. Specified Requirements of Antibacterial Textiles for General Use

Technical Data Monograph. V-PRO max Low Temperature Sterilization System

Cleaning Efficiency of The MicroOne Wipe and Mop Cleaning System

Log Reduction & UV Deceptive Advertising

GLUTEX GQ1 Sanitizer CAS Reg. No

Disinfection Qualification Testing

Study Title Antibacterial Activity and Efficacy of KHG FiteBac Technology Test Substance Using a Suspension Time-Kill Procedure

Final text for addition to The International Pharmacopoeia

Alpha HydroMAID Cleaning Effectiveness of the Alpha HydroMAID Cleaning System versus Conventional Mopping

The Effect of Air Pockets on the Efficiency of Disinfection of Respiratory Equipment by Pasteurization

ADANTIUM PLUS. Powerful disinfectant, cleansing and deodorising devised for the disinfection/cleansing of medical devices and surgical instruments.

Principles of Chlorine Dioxide Gas as a Decontamination Method

Decontamination Effectiveness of Esco Celsafe CO2 Incubator Sterilization Feature using High Heat Temperature By Bekti Tri Sumaryati

Result:COMPLETE Report Date: December 28 th, 2015

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

Powerful disinfectant, cleansing and deodorising devised for the disinfection/cleansing of medical devices and surgical instruments.

Indigo-Clean White Paper: #1 Bactericidal Performance Testing of Indigo-Clean Upon Bacterial Species. Healthcare

TEST CODE DEFINITION STERRAD H202. Test Code Test Name Testing Description. Cycle. Efficacy. SE-200 STERRAD 200 Efficacy. Cycle. STD Cycle Efficacy

This document is a preview generated by EVS

Dryflex. Antimicrobial TPEs

Study Title Antibacterial Efficacy of Bio-Care Technology's Non-Porous Test Substance

SecuSan The new hygiene standard Clinically tested

3.0. Materials and methods

01/08/2018. Control of Microbial Growth. Methods. Terminology. Disinfectants and Antiseptics. Three approaches. Cleaning. Chemical.

BromMax 7.1 CONCENTRATED LIQUID BROMINE BIOCIDE

Assessment of Antibacterial Efficacy of Goldshield against MRSA and VRE

INTRODUCTION Sanitization sterilization Antibiotics Bactericidal Bacteriostatic Antiseptics disinfectants

Antimicrobial effectiveness evaluation of Isocide powder coating versus stainless steel plate

Oxivir. Tough on Pathogens, Not on People Fast*, Effective, Responsible

STER-AHOL WFI Formula and STER- AHOL Aerosol WFI Formula 70% USP Denatured Ethanol formulated with 30% USP Water for Injection

Study done by : Pr M. CULOT : Head of the Laboratory Ir Th. FIEVEZ, : Head of the Study. With the collaboration of :

Precision. Proficiency. Proximity.

Lab Exercise #4 Microbial Control Lab Exercise #4 Control of Microorganisms: Physical, Chemical and Chemotherapeutic

Standard Operating Procedure Title: Stock Suspensions of Micro-Organisms

bottom of the cylindrical chamber. The chamber is sterilized by dipping in alcohol and flaming. Placing the open end of the

KILL-TIME STUDIES Antimicrobial Activity of EO H 2 O Using Clostridium difficile spores Test Solutions: Acidic H 2 O Submitted December 12, 2011

FINAL REPORT STUDY TITLE

How is Sterilization Validation Performed by the Medical Device Manufacturer?

Method Suitability Report Membrane Filtration Sterility Test with QTMicro Apparatus

NIMBUS The Next Generation in Antimicrobial Protection. October, 2010

Nitrogen Dioxide (NO 2 ) PDA: A Global. Sterilization and. Association. Decontamination Systems. November 4, PDA Europe Parenterals 2014

Puritan Environmental Sampling Kit (ESK )

PRESERVATIVE EFFICACY TEST FOR COSMETIC PRODUCT

KORALONE C-204 Preservative for Household and Industrial & Institutional Products

Efficacy Report Summarization for SoClean 2

Screening Test: Determine the Removal Efficiency of Enzymes against a Pseudomonas aeruginosa biofilm grown in the CDC Biofilm Reactor

phenolic and quaternary ammonium compounds. Logarithmic reductions of

COMPATIBILITY BETWEEN THE FORMULATION & THE SYSTEM

Technical Data Monograph. Reliance EPS Endoscope Processing System

Guidelines for Disinfection and Sterilization in Healthcare Facilities, 2008 (Centers for Disease Control)

Best Practices for Environmental Cleaning. MODULE 3 Cleaning Products and Tools

Premium PAA. Sanitation with Peracetic Acid

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

Antimicrobial Lab Test Report

bottom of the cylindrical chamber. The chamber is sterilized by dipping in alcohol and flaming. Placing the open end of the

PIROR 850 Slimicide CAS Reg. No (Canada Only)

FI J Page 1 of 11

6/28/2016. Control of Microbial Growth. Method. Terminology. Disinfectants and Antiseptics

á62ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: TESTS FOR SPECIFIED MICROORGANISMS

Transcription:

TOXICITY, EFFICACY, STABILITY AND CORROSION TEST RESULTS MICROCYN TECHNOLOGY TOXICITY STUDIES SKIN IRRITATION This study was conducted to assess the potential of Microcyn to produce dermal irritation and was conducted at Northview Pacific Laboratories, Inc, an ISO-certified lab located in California. Three New Zealand White rabbits each received 0.5mL of Microcyn applied directly to intact clipped skin sites. After a minimum of 4 hours of exposure to Microcyn, the test sites were observed at 1, 24, 48 and 72 hours. All test samples at each time interval showed no signs of erythema or edema formation. Therefore, it was concluded that the irritation response category of Microcyn is classified as negligible. Zobair Musa, Study Director, Northview Pacific Laboratories OCULAR IRRITATION This study was conducted to assess the potential of Microcyn to produce ocular irritation and was conducted at Northview Pacific Laboratories, Inc. In this study, three New Zealand white rabbits each received 0.1mL of Microcyn applied directly into the right eye. The test sites were observed at 1, 24, 48 and 72 hours. All test samples at each time interval showed no signs of clinical observations or ocular irritation. Therefore, it was concluded that Microcyn did not cause a positive irritation response in the eyes of the test animals. Zobair Musa, Study Director, Northview Pacific Laboratories ACUTE ORAL TOXICITY Microcyn was evaluated for its acute oral toxicity potential in albino rats when administered as a gavage dose at a level of 5000mg/kg. Three (3) female albino rats each received a volume of Microcyn of 4.98ml/kg. Each dose was administered using an appropriately sized syringe and stainless steel ball-tipped intubation needle. Observations for mortality and clinical/behavioral signs of toxicity were made at least three times on the day of dosing (Day 0) and at least once thereafter for 14 days. Individual body weights were recorded just prior to dosing and on Days 7 and 14. On Day 14 after dosing, each animal was sacrificed and subjected to gross necropsy. There was no mortality during the study in any of the test subjects. Body weight gain was unaffected by the administration of the test substance. All animals appeared normal for the duration of the study. The gross necropsy conducted at termination of the study revealed no observable abnormalities. Janice O. Kuhn, PhD, DABT, Stillmeadow, Inc. ACUTE DERMAL TOXICITY Microcyn was evaluated for its dermal toxicity potential and relative skin irritancy when a single, undiluted dose of 5050mg/kg was applied to the intact skin of albino rabbits. Ten (10) rabbits each received a thin, uniform layer of Microcyn applied to the dorsal surface of the trunk. The test area was then covered with gauze and secured with non-irritating adhesive tape. After 24 hours, the wrappings were removed and the test areas were gently washed to remove any test substance. Observations for mortality and clinical/behavioral signs of toxicity were made at least three times on

the day of dosing (Day 0) and at least once thereafter for 14 days. Individual body weights were recorded just prior to dosing and on Days 7 and 14. Observations for dermal irritation were made at approximately 60 minutes after removal of wrappings, and on Days 4, 7, 11 and 14. On Day 14 after dosing, each animal was sacrificed and subjected to gross necropsy. There was no mortality during the study in any of the test subjects. Body weight gain was unaffected by the administration of the test substance, with the exception of one male and one female that lost weight, and one female that failed to gain weight between Days 7 and 14. All test subjects appeared normal for the duration of the study. There were no signs of dermal irritation in any animals at any time during the study. The gross necropsy conducted at termination of the study revealed no observable abnormalities. Janice O. Kuhn, PhD, DABT, Stillmeadow, Inc. ACUTE INHALATION TOXICITY Microcyn was evaluated for its acute inhalation toxicity potential in ten (10) albino rats. The test subjects were individually housed in polycarbonate exposure test tubes that were then inserted into a 500L stainless steel nose-only inhalation chamber for four (4) hours once a 99% concentration was attained. Each test subject was exposed to an aerosol generated from the undiluted test substance at a level of 2.16 mg/l. Observations for mortality and signs of pharmalogic and/or toxicologic effects were made frequently on the day of exposure and at least once daily thereafter for 14 days (Day 0 is day of exposure). Individual body weights were recorded just prior to the inhalation exposure and on Days 7 and 14. On Day 14 after exposure, each animal was euthanized and subjected to gross necropsy and all abnormalities were recorded. There was no mortality during the study. As indicated by the date, the acute inhalation LC 50 for Microcyn is greater than 2.16mg/L. Body weight gain was unaffected by the administration of the test substance, except for one male that failed to gain weight between Days 0 and 7. Prominent in-life observations included very-slight to slight activity decreases and piloerection in both sexes at 4.5 and 6 hours. Animals were asymptomatic by Day 1. The gross necropsy conducted on each animal at termination of the study revealed no observable abnormalities. Therefore, Microcyn passed the acute inhalation limit test of >2mg/L for 4 hours. Lori Carter, BA, Stillmeadow, Inc. DERMAL SENSITIZATION A skin sensitization study was conducted on thirty (30) guinea pigs to determine if Microcyn produced a sensitizing reaction. Twenty (20) test subjects (Group II) were treated with 0.4 ml of undiluted Microcyn administered beneath a surgical gauze patch and then securely taped. Each animal was then placed in a restrainer for approximately six (6) hours. The animals were treated once weekly for three (3) weeks, for a total of three (3) treatments. At the end of the exposure period, the animals were removed from the restrainers and the wrappings and patches were removed. After a two-week rest period, all animals (Group II and ten (10) animals in the untreated control Group I) were challenged (the "challenge treatment") at a virgin test site with an application of 0.4 ml of undiluted test substance administered in the same manner as the induction treatments of Group II. Observations for skin reactions at each test site were made approximately 24 hours and 48 hours after the first treatment and at 48 hours after the challenge treatment. Microcyn produced no irritation in Group I after the single treatment at challenge. Likewise, Microcyn produced no irritation in Group II after the challenge treatment and therefore did not elicit a sensitizing reaction in guinea pigs. Therefore, Microcyn can be characterized as a non-sensitizer. Janice O. Kuhn, PhD, DABT, Stillmeadow, Inc.

EFFICACY STUDIES SPORICIDAL SCREEN Fifteen test samples were challenged with Bacillus subtilis mixed with a 5% organic load. Test samples were prepared in accordance with the EPA-recognized AOAC sporicidal test method. Microcyn passed the sporicidal test when the porcelain penicylinders were exposed for 15 minutes at 20 C. All samples exhibited zero growth. Felicia L. Sellers MICROBIOTEST, Inc BACTERICIDAL This test uses Pseudomonas aeruginosa (ATCC #15442), Staphylococcus aureus (ATCC #6538) and Salmonella choleraesuis (ATCC #10708). Three lots of Microcyn were tested on 60 carriers per lot per organism. A film of bacterial cells dried on a surface of stainless steel carriers was exposed to the test substance. Following exposure, the carriers were transferred to vessels containing neutralizing subculture medium (Letheen Broth + 0.1% Sodium Thiosulfate) and assayed for survivors. Test samples were incubated at 35 ± 2 C for 48 hours. This test was conducted in accordance with the EPA-recognized AOAC Use-Dilution method. For each lot of 60 carriers, EPA requirements specify that a minimum of 59 must show no growth. This requirement was met for each of these three organisms (see below). Total # of Total # of Test Test Exposure Sample Carriers Carriers Showing Substance Organism Time Dilution Exposed Growth** Microcyn P. aeruginosa 10 minutes RTU 180 0 Microcyn S. aureus 10 minutes RTU 180 2 Microcyn S. choleraesuis 10 minutes RTU 180 1 RTU=Ready to Use **Number of carriers showing growth of the test organism BACTERICIDAL This test was conducted using Escherichia coli 0157;H7 (ATCC #35150) was conducted on two lots of Microcyn using 10 carriers per lot. A 5% organic load was added to each test sample. The carriers were exposed to Microcyn for 1 minute and incubated for 48 hours at 35 ± 2 C. This test was conducted in accordance with the EPA-recognized AOAC Use-Dilution method. All results showed zero growth after one-minute exposure time. MRSA This test uses Staphylococcus aureus (ATCC #33592). Sterile penicylinders were immersed for 15 minutes in a 48-54 hour-old broth culture of the test organism at the ratio of 1 carrier per 10ml. The penicylinders were then dried on filter paper in a sterile petri dish at 36 ±1 C for 40 minutes at 71.2% RH. Ten (10) contaminated and dried carriers were then transferred to individual tubes containing 10ml of Microcyn and exposed for 10 minutes at 20 ±1 C. The carriers were then transferred to a neutralizing solution and incubated for 48 hours at 36 ±1 C. At the end of this time, each carrier was examined for the presence or absence of visible growth. Appropriate controls were conducted and all met the appropriate acceptance criteria. Two lots of Microcyn were used. No growth was observed on any of the twenty (2 lots, 10 carriers) subcultures after 10-minute exposure to Microcyn.

VRE This test uses Enterococcus faecalis Vancomycin Resistant (ATCC #51299). Sterile penicylinders were immersed for 15 minutes in a 48-54 hours-old broth culture of the test organism at the ratio of 1 carrier per 10ml. The penicylinders were then dried on filter paper in a sterile Petri dish at 36 ±1 C for 40 minutes at 76.1% RH. Ten (10) contaminated and dried carriers were then transferred to individual tubes containing 10ml of Microcyn and exposed for 10 minutes at 20 ±1 C. The carriers were then transferred to a neutralizing solution and incubated for 48 hours at 36 ±1 C. At the end of this time, each carrier was examined for the presence or absence of visible growth. Appropriate controls were conducted and all met the appropriate acceptance criteria. Two lots of Microcyn were used. No growth was observed on any of the twenty (2 lots, 10 carriers) subcultures after 10-minute exposure to Microcyn. MYCOBACTERIUM/TUBERCULOCIDAL This test uses Mycobacterium bovis (OT 105401) according to Tuberculocidal Quantitative Suspension (EPA) protocol. This was conducted under EPA Good Laboratory Practice Regulations (GLP). A 5% organic load (fetal bovine serum) was added to the organism suspension. A single tube was inoculated to the organism followed by exposure to Microcyn for 5 minutes. Samples were incubated for 20 days at 35 ± 2 C. No growth after 5-minute contact time. AOAC AVAILABLE CHLORINE IN DISINFECTANTS This test uses Salmonella typhi (ATCC #6539). A 0.05mL aliquot of the test culture suspension was added to the test substance and control NaOCI solutions previously equilibrated to 37 C. One minute after addition of the test organism, one loopful of each medicated culture was transferred to the subculture medium. Each tube was then challenged with an additional 0.05mL aliquot of the test culture 30 seconds after subculturing. This process was repeated for a total of 10 subcultures for each lot and control. The neutralized subcultures were incubated for 48 hours at 35 ± 2 C. Following incubation, the subcultures were examined for the presence or absence of visible growth. This test was conducted in accordance with the EPA-recognized AOAC Use-Dilution method. Test Test Concentration Subculture Series Substance Organism or Lot 1 2 3 4 5 6 7 8 9 10 NaOCI Control S. typhi 200 ppm 0 0 0 0 0 0 0 + + + NaOCI Control S. typhi 100 ppm 0 0 0 0 + + + + + + NaOCI Control S. typhi 50 ppm 0 0 + + + + + + + + Microcyn S. typhi Lot # 090803 0 0 0 0 0 0 0 + + + +=Growth of Organism 0=No growth of organism. The subcultures of positive broths (tubes showing growth) demonstrated pure cultures of the test organism. David Rottjakob, M.T. ATS labs Therefore, Microcyn with available chlorine levels of approximately 60 ppm has demonstrated germicidal equivalence to a control sample with 200 ppm available chlorine. Salmonella typhi was used as the challenge microorganism.

VIRUCIDAL Two lots of Microcyn were tested to determine efficacy when exposed to the Human Immunodeficiency Virus Type I, Strain HTLV-IIIB in the presence of 5% organic soil load. For each lot of test substance, separate dried virus films were exposed to 2.0 ml of the use dilution for ten minutes at 21C. The filtrate (10-1 dilution) was then tittered by 10-fold serial dilutions and assayed for infectivity. The reduction in viral titer was 3.75 log10 for both lots. Therefore, Microcyn demonstrated complete inactivation of the HIV-1 virus at a 10-minute exposure time. HIV-1 HIV-1 Dried Virus Control +Lot P120104 +Lot P130104 Dilution (Group A) (Group B) (Group B) Cell Control 0000 0000 0000 10-1 ++++ TTTT TTTT 10-2 ++++ 0000 0000 10-3 ++++ 0000 0000 10-4 ++++ 0000 0000 10-5 ++00 0000 0000 10-6 +000 0000 0000 10-7 0000 0000 0000 TCID50/0.2mL 10 5.25 10 1.5 10 1.5 T=Toxic +=Cytopathic effect 0=No cytopathic effect Mary J. Miller, M.T. ATS Laboratories VIRUCIDAL SCREEN Microcyn was tested against Canine parvovirus using an exposure period of 15 minutes. The test substance was combined with a 1% organic load. Test samples were incubated for 7 days at 36-38 C. Microcyn demonstrated complete inactivation of the virus following a 15-minute exposure time. This test was in accordance with key segments of the EPA-recognized ASTM Virucidal Efficacy of a Disinfectant for Use on Inanimate Environmental Surfaces. David Rottjakob, M.T. ATS labs STABILITY STUDIES Microcyn has been shown to be stable and effective when aged. Product chemistry and antimicrobial efficacy for both real-time and accelerated-aging have been tested in accordance with EPA, FDA (CDRH) and ICH guidelines. Based upon this data, the product has a shelf life of one (1) year. Accelerated product shelf life studies at 50 C support a 2-year product shelf life. Additional real-time data is currently being gathered to support 2-year real-time shelf life.

CORROSION STUDIES Good Lab Practices (GLP) were utilized to document the chemical resistance testing of various materials repeatedly exposed to Microcyn. The corrosion test was performed in accordance with the requirements of ASTM standards G60 and G1. Test coupons of materials were representative of what would be expected if these materials were in service. Coupons were cleaned to remove contaminants in appropriated methods that would not affect coupon s material, mechanical and physical properties. Six specimens and one control of each material were tested. Acceptance criteria included that the weight and visual appearance of each coupon should be equivalent after testing. The materials tested were: PVC, 303 Stainless Steel, 316 Stainless Steel, HA Aluminum, Titanium, Aluminum, Polyester, Teflon, Polypropylene, Natural Rubber, HDPE, Neoprene, Nylon, Silicone, Polycarbonate, Polyurethane, LDPE, Polysulfone, UHMWP and 416 Stainless Steel. Conclusion: All plastics and elastomers have met the stated acceptance criteria set forth in the ASTM standards by maintaining equivalent weight and appearance throughout the study. Any instance where weight gain occurred has been successfully attributed to either the humid environment or the inherent properties of the material involved. Based on the data, Microcyn is compatible with all the materials tested and is not considered corrosive. The exceptions are Aluminum and 416 Stainless Steel, which are prone to corrosion due to exposure to moisture in the environment. QUALITY CONTROL Microcyn is manufactured under Good Manufacturing Practices (cgmp) requirements set forth by the U.S. Food and Drug Administration (FDA) and ISO 13485 standards. All manufacturing lots are tested for anti-microbial effectiveness using suspension method (Bacillus subtillis spores to document a 10 6 reduction) ph, ORP, and free available chlorine levels. For more information on the non-toxic Microcyn technology, visit our web site at www.oculusis.com. UNITED STATES: Oculus Innovative Sciences, 1129 North McDowell Blvd., Petaluma, California 94954 USA tel: (707) 283-0550, fax: (707) 283-0551, website: www.oculusis.com INTERNATIONAL: Manufacturing and distribution facilities in Morelia, Mexico and Sittard, The Netherlands 09/10/04