PLETTAC METRIX COMPONENT CAPACITIES. Providing quality products and services at a competitive price.

Similar documents
2017 RING SYSTEM TECHNICAL MANUAL HIRE ONLY UNITED KINGDOM

PLETTAC METRIX USER GUIDE

TRAD HIRE & SALES SCAFFOLDING SUPPLIER USER GUIDE PLETTAC METRIX FOCUSSED ON SERVICE

USER S MANUAL HAKI CONTINENTAL

ENGINEERING INFORMATION

Layher Aluminium Lattice Beams. Information and User Guide. Aluminium Lattice Beam 750 (Product Code 4903XXX)

USER S MANUAL HAKI UNIVERSAL

USER S MANUAL HAKI UNIVERSAL ALUMINIUM

distribution Modular Scaffolding

PERI UP Easy * The lightweight and fast frame scaffold for safe working on facades

ASSEMBLY.

Genlok User Guide.

The Total Solution. Plettac Contur. No.1 for Multidirectional Modular System Scaffold. An Altrad Group Company

Lattice Beam User Guide USG001-

Trailer Stage. Structural design calculations. 2nd September [00]

Example of a modelling review Roof truss

Contents 2017 VR ACCESS SOLUTIONS ALL RIGHTS RESERVED.

Allround Scaffolding

USER S MANUAL. HAKI Loading Tower

Configuration. User Guide. Version: Copyright 2017 Computer and Design Services Ltd GLOBAL CONSTRUCTION SOFTWARE AND SERVICES

K stage System Scaffold

Modular Scaffolding MEKA 48

Acrow Slim-Max Soldier System

USER S MANUAL HAKI PUBLIC ACCESS STAIR

Allround Scaffolding

UNIT I SIMPLE STRESSES AND STRAINS, STRAIN ENERGY

Question Paper Code : 11410

Sales Hire Erections

Turnlok 355 System Scaffolding

Code No: R Set No. 1

CCTV Headquarters Case Study. ARCH 631 Haowei Cheng, Peixin Dong, Xiaoying He, Zepeng Jia, Dongqi Zhu


FEM-Design Useful Examples

Structural Design of Pergola with Airfoil Louvers

Design Calculations Date: 27/04/2017

CUPLOK SGB CUPLOK SGB Group

Allround Scaffolding. Layher Allround Bridging System Instructions for Assembly and Use. Modular truss system for wide spans

USER S MANUAL HAKI STAIR TOWER

VALLIAMMAI ENGINEERING COLLEGE

Unit II Shear and Bending in Beams

COLUMNS. Classification of columns:

USER S MANUAL HAKI PUBLIC ACCESS STAIR

SOUTH AFRICAN NATIONAL STANDARD

ALBLItZ 70 S INSTRUCTION FOR ERECTION AND USE

Austral Deck Design for Construction Loading. Permanent formwork and Span capability

Level 6 Graduate Diploma in Engineering Structural analysis

Erection manual. Tube-Lock Concept. van Thiel United b.v Page: 1 of 15

USER S Manual. HAKI Bridge System (HBS)

Instructions for erection and use of the RUX-SUPER 65 Rapid-Erection Scaffolding. - Standard Design - Rapid-Erection Scaffolding RUX-SUPER 65

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

It must be lowered 5 feet (1.5 meters) onto the bearings. Waterway clearance is decreased.

USER S MANUAL HAKI UNIVERSAL

USER S manual HAKI UNIVERSAL. International version

Technical Data Sheet. Mass 10 Mass 25 Mass 50 M AT 125. Eurocode Compliant. T E C H N I C A L D A T A S H E E T Mass 10. MU Bridging Compact Bridging

Acrow SuperCuplok Scaffolding System

USER S MANUAL HAKI COMPACT STAIR TOWER

scaffoldings/ coverings

NODIA AND COMPANY. GATE SOLVED PAPER Civil Engineering Design of Steel Structure. Copyright By NODIA & COMPANY

FALSEWORK SOLUTIONS: SLAB SHORING SYSTEM - ROYALFRAME50 SERIES

USER S MANUAL HAKI COMPACT STAIR TOWER

Since it was established in 1989, with a small manufacturing base in Qwa Qwa, Uni-Span has grown to become one

BSI British Standards

USER S GUIDE for HAKITEC 750. TEMPORARY ROOF with HAKI Trak Sheeting ( Hand-Built )

R13. II B. Tech I Semester Regular/Supplementary Examinations, Dec MECHANICS OF SOLIDS (Com. to ME, AME, AE, MTE) Time: 3 hours PART-A

Allround Scaffolding. Propping Technical Brochure. The universal system for everyday and engineered scaffolding solutions

Generation Hop up brackets to be removed and boards moved to lift above.

Subject with Code: Strength of Materials(16CE104) Course& Branch: B. Tech - CE Year &Sem : II-B. Tech &I-Sem Regulation: R16

1.Axial Force, Shear Force and Bending Moment:

Tubes & Couplers Scaffolding

modular scaffolding R+

R10 Set No: 1. Design of Machine Members-I (Mechanical Engineering) Time: 3 Hours Max Marks: 75 ''' ' '' '' ''

Technical Data Sheet Products

UNI Roof Catalogue CTG001-

CADS A3D MAX. How to model shear walls

COMPOSITE STRUCTURES PREPARED BY : SHAMILAH

QUIZ 2 Allotted Time: 3 hours

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure

Technical Data Sheet. British Standards Compliant. T E C H N I C A L D A T A S H E E T MAT 125 (British Standards) Mass 10 Mass 25 Mass 50 MAT 125

(a) Pin-Pin P cr = (b) Fixed-Fixed P cr = (d) Fixed-Pin P cr =

Modular Scaffold MEKA 48

St.MARTIN S ENGINEERING COLLEGE

Cut costs, improve safety, increase efficiency: Scaffolding for shipyards and offshore. Layher. More Possibilities. The Scaffolding System.

Layher. Keder Roof and Keder Hall. More Possibilities. The Scaffolding System. Layher Keder Roof and Keder Hall Instructions for Assembly and Use

PERI PD 8 The cost-effective shoring for slab tables and high loads

Temporary works equipment

Allround Scaffolding System

Council on Tall Buildings

Ring System Scaffolding φ60.2mm Instruction Manual

Propping and Needling. Prop Units Grillage Beams Properties Fittings Bracing

user s guide for ( Hand-Built )

Diploma in Civil Engineering. Term-End Examination June, BCE-041 : THEORY OF STRUCTURES II

Schöck Isokorb type KS

UNIT-I DESIGN CONCEPTS, DESIGN OF BEAMS Part - A (Short Answer Questions)

RINGLOCK Introduction Ringlock is world most widely used scaffold system. It is a fully galvanized multi purpose steel scaffold system suitable for pr

Everup Scaffolding & Formwork Pty Ltd - Priced Stock List

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

modular scaffolding R+

Rolling Towers. Layher Uni Light Tower Instructions for Assembly and Use. Mobile working platforms according to DIN EN 1004:

Transcription:

PLETTAC METRIX COMPONENT CAPACITIES Providing quality products and services at a competitive price. Valid Only For Genuine Equipment

COMPONENT CAPACITIES COMPONENT CAPACITIES Loads given in this document are safe working loads, therefore they may be applied without any further reduction. They enable the user to estimate the capabilities of individual PLETTAC METRIX scaffold configurations. For more comprehensive calculation the detailed loading data supplied separately by the manufacturer shall be taken into account. The detailed loading data contains the complete set of loading and spring stiffness of the components. They are third party controlled and stated in the German approval Z-8.22-843 and French approval NF-096, please contact your local depot for further details. The load capacities given in this document are for individual components only and should not be used in isolation. The overall structural integrity and global stability of the scaffold structure must be checked by an appropriately qualified person, such as a competent temporary works / scaffold design engineer. DISCLAIMER: Whilst and the author have made every reasonable effort to ensure that the information contained within this guide is correct at the time of printing, you should be aware that and the author do not accept any liability for any inconvenience, loss or damage caused by the result of any inaccuracy, or omission, within this publication. 1 Ledger Wedge Head The most often used loading values are shown by sketches. They shall only be taken into account where the junction is loaded without any other interaction. The bending moment My is the vertical cantilevering moment (Load*Distance). Ledger: Allowed My = ± 0.63kN The normal load N is the tensile or compressive load along the ledger axis. Ledger: Allowed N = ± 20.20kN 1 PLETTAC METRIX Component Capacities

The vertical load Vz is the load to be transferred vertically by the ledger wedge head to the rosette. The full value given is only relevant when the load is applied just behind the wedge head, and there is no further effect from other bending moments. Allowable Vz = ± 17.30kN COMPONENT CAPACITIES Where several ledgers are transferring loads to the same rosette, the sum of these loads may not exceed the following: Allowable ΣVz = ±48.80kN The horizontal load Vy represents loads from wind or other means to be transferred horizontally from the ledger wedge heads into the rosette. Ledger: Allowable Vy = ± 6.20kN The bending moment Mz is the horizontal cantilevering moment (Load * Distance). Ledger: Allowable Mz = ± 0.145kNm The twisting moment M T represents resistance against twisting for ledgers connected into the junction. Ledger: Allowable M T = ± 0.387kNm 2016 2

COMPONENT CAPACITIES 2 Vertical Diagonal Brace Vertical diagonal brace reinforce the scaffolding and are the key component for the stability of the entire scaffolding. The load to be transferred from brace to rosette may not exceed: Allowable Nv = ± 16.30kN In the case that this load is applied by tension all vertical brace will be able to transfer this load regardless of the length. In the case that the load is applied by compression the axial stiffness of the tube becomes relevant. Table 1 contains the safe working loads for a single brace loaded by tension or compression (Nv). Also the horizontal (Q) and vertical (V) components of this load are shown. Note: Where several brace are used to support a certain load the addition of the capacities is only allowed if all braces have the same length and all are loaded in the same way (all with compression or all with tension). Where different types of brace are used, or in situations where the type of loading differs (compression or tension) the max. capacity of the system has to be calculated by taking the resistance of the single components into account. Relevant data is available from, or on the basis of the German approval. All figures given are for a lift height of 2.00m. Bay α ( ) TABLE 1 Capacity of Vertical Diagonal Brace All. Nv Loading by Tension All. Q All. V All. Nv Loading by Compression All. Q All. V 3.00 35.10 13.30 9.40-5.12 4.20 2.90 2.50 40.50 12.40 10.60-6.17 4.70 4.00 2.00 47.30 11.10 12.00-7.62 5.20 5.60 +16.30 1.50 56.10 9.10 13.50-9.59 5.40 8.00 1.00 67.10 6.30 15.00-12.32 4.80 11.40 0.70 74.80 4.30 15.80-13.81 3.60 13.30 3 PLETTAC METRIX Component Capacities

3 Standards The given values for allowable loading of vertical standards are just applicable for preliminary estimations. The allowable tension loads are applicable to bolted spigot standards only, with 4 bolts per joint. COMPONENT CAPACITIES Buckling Allowable Compression Load Allowable Tension Load TABLE 2 Capacity of Standards 1.00 1.50 2.00 2.50 3.00 60.00 39.53 26.13 18.00 13.13 36.67 4 Adjustable Base Jacks / Swivel Base Jacks / U-Heads of Thread Visible Allowable Compression Load* TABLE 3 Capacity of Base Jacks / Swivel Base Jacks / U-Heads 0.10 0.20 0.30 0.40 0.50 0.60 60.00 50.00 40.00 32.50 22.50 15.00 *Hypothesis: It is assumed there is 0.50kN applied horizontally to the base of the base plate, and a 2.50% deviation between the threaded tube of the jack and the axis of the scaffolding vertical. 2016 4

COMPONENT CAPACITIES 5 Transoms and Ledgers The following tables contain the capacities of s and ledgers. The data refers to the current design at the time of writing this guide. The following s and or ledgers are regarded separately: Table 4: Single Transoms / Ledgers; Tubular Support. Table 5: Reinforced Transoms and Ledgers; Tubular Support. Table 6: Intermediate Transoms. For evaluating the capacity, the elastic reaction between ledger and standard has been taken into account (although this is not relevant for intermediate s). The self weight of decks has also been considered (Steel decks ~0.23 kn/m²). allow. p: Allowable safe working load for the area to be supported by the. Should this value be greater than the deck capacity, the maximum load allowable is that of the decks, otherwise the decks need to be reinforced to achieve the value. 1st column central, 2nd column perimeter * ) allow. P: 1x P = allowable single point load at the centre of the 2x P = allowable single point loads equally spaced dividing the into three similar distances * ) On birdcage scaffolds, every may be considered as a perimeter as long as the deck orientation is changed every bay. The separate columns of the tables give the data as described: allow. q: Allowable uniformly distributed load along the / ledger. Deck : Bay size to be supported by the. For single s and ledgers allowable traction load = 20.20kN for all lengths. For single s and ledgers allowable compression load = 20.20kN for all lengths except 2.50m and 3.00m, these values are 15.67kN and 11.40kN respectively. Transom TABLE 4 Capacity of Single Transoms and Ledgers; Tubular Support allow. q (kn/m) 0.70 24.40 1.00 13.50 Deck central perimeter 3.00 7.90 16.00 2.50 9.50 19.30 2.00 12.00 24.20 1.50 16.00 32.30 3.00 4.30 8.80 2.50 5.20 10.60 2.00 6.50 13.30 1.50 8.80 17.80 allow. P 7.40 6.10 (Continued) 5 PLETTAC METRIX Component Capacities

Transom TABLE 4 Capacity of Single Transoms and Ledgers; Tubular Support (continued) allow. q (kn/m) 1.30 8.20 1.50 5.60 2.00 3.30 2.50 2.10 3.00 1.50 Deck central perimeter 3.00 2.50 5.20 2.50 3.10 6.30 2.00 3.90 8.00 1.50 5.20 10.70 3.00 1.60 3.50 2.50 2.00 4.30 2.00 2.60 5.40 1.50 3.50 7.20 3.00 0.90 2.00 2.50 1.10 2.40 2.00 1.40 3.10 1.50 2.00 4.20 3.00 0.50 1.20 2.50 0.60 1.50 2.00 0.80 1.90 1.50 1.20 2.60 3.00 0.30 0.80 2.50 0.40 1.00 2.00 0.50 1.30 1.50 0.80 1.80 allow. P 4.70 3.80 2.90 2.40 2.00 COMPONENT CAPACITIES Transom 1.00 (Transom) 1.30 (Transom) TABLE 5 Capacity of Reinforced Transoms and Double Ledgers; Tubular Support allow. q (kn/m) 28.80 18.50 Deck central perimeter 3.00 9.40 19.00 2.50 11.30 22.80 2.00 14.20 28.60 1.50 19.00 38.20 3.00 5.90 12.10 2.50 7.20 14.60 2.00 9.00 18.30 1.50 12.10 24.40 allow. P 1 x 13.60 1 x 11.40 (Continued) 2016 6

COMPONENT CAPACITIES TABLE 5 Capacity of Reinforced Transoms and Double Ledgers; Tubular Support (continued) Transom 1.50 (Transom) 1.50 (Ledger) 2.00 (Ledger) 2.50 (Ledger) 3.00 (Ledger) allow. q (kn/m) 12.80 24.70 14.00 8.40 4.60 Deck central perimeter 3.00 4.00 8.30 2.50 4.90 10.00 2.00 6.20 12.60 1.50 8.30 16.80 3.00 8.00 16.20 2.50 9.70 19.50 2.00 12.10 24.50 1.50 16.20 32.70 3.00 4.40 9.10 2.50 5.40 11.00 2.00 6.80 13.80 1.50 9.10 18.40 3.00 2.60 5.40 2.50 3.10 6.50 2.00 4.00 8.20 1.50 5.40 11.00 3.00 1.30 2.90 2.50 1.60 3.50 2.00 2.10 4.40 1.50 2.90 5.90 allow. P 1 x 9.20 1 x 15.30 2 x 15.10 1 x 11.30 2 x 8.70 1 x 8.10 2 x 6.60 1 x 7.20 2 x 5.40 Transom TABLE 6 Capacity of Intermediate Transoms allow. q (kn/m) allow. P 0.70 20.60 7.20 1.00 10.10 5.00 1.50 4.50 3.30 2.00 2.50 2.50 2.50 1.60 2.00 3.00 1.10 1.60 7 PLETTAC METRIX Component Capacities

6 Decks & Steel Scaffold Boards Type Steel, 0.30m Wide TABLE 7 Capacity of Decks Steel, 0.20m Wide Aluminium, 0.30m Wide Aluminium, 0.60m Wide Aluminium / Timber, 0.60m Wide COMPONENT CAPACITIES kn/m 2 kn/m 2 kn/m 2 kn/m 2 kn/m 2 3.00 6.00 6.00 3.00 2.00 2.00 2.50 6.00 6.00 3.00 4.50 4.50 2.00 6.00 6.00 3.00-4.50 1.30 6.00 6.00 - - - 1.50 6.00 6.00 - - 4.50 1.00 6.00 6.00 - - - 0.70 6.00 6.00 - - - TABLE 8 Capacity of Steel Scaffold Boards Type 0.30m Wide 0.20m Wide Point Load kn/m 2 kn/m 2 kn 3.00 2.00 2.00 1.50 2.50 3.00 3.00 3.00 2.00 6.00 6.00 3.00 1.50 6.00 6.00 3.00 1.00 6.00 6.00 3.00 0.70 6.00 6.00 3.00 7 Console Hop-Up Brackets Type TABLE 9 Capacity of Console Hop-Up Brackets Uniformly Distributed Load Point Load to Outer Wedge Head Centre Point Load kn/m kn kn 0.22m Coupler 7.20 3.60 7.20 0.40m Lite 7.70 3.40 3.40 0.40m Reinforced 11.20 5.50 10.60 0.70m Reinforced 6.30 3.10 6.70 1.00m Reinforced 8.30 8.30 6.60 2016 8

COMPONENT CAPACITIES 8 Galvanised Wedge Head Beams Summary of total distributed loads on the top chord of the beam according to lacing length and beam length. TABLE 10 Capacity of Galvanised Steel Wedge Head Beams Tie Chord Centres None 1.00m 1.25m 1.50m 2.00m 2.50m 3.00m 3.50m 4.00m UDL kn/m kn/m kn/m kn/m kn/m kn/m kn/m kn/m kn/m 10.00-2.50 - - 1.10 0.80 - - - 9.00-3.10-2.10 - - 0.60 - - 8.00-4.10 - - 2.90 - - - 0.90 7.00-4.80 - - 3.80 - - 2.00-6.00-5.80-4.20 - - 2.40 - - 5.00 - - 7.30 - - 4.70 - - - 4.00 5.00 - - - 9.40 - - - - 3.00 13.10 - - - - - - - - 2.50 15.70 - - - - - - - - CPL kn kn kn kn kn kn kn kn kn 10.00-12.80 - - 5.80 4.30 - - - 9.00-14.40-10.30 - - 3.40 - - 8.00-16.70 - - 11.50 - - - 3.50 7.00-17.70 - - 15.30 - - 8.10-6.00-21.30-15.60 - - 8.70 - - 5.00 - - 20.20 - - 15.00 - - - 4.00 14.70 - - - 24.80 - - - - 3.00 23.40 - - - - - - - - 2.50 26.30 - - - - - - - - UDL = Uniformly Distributed Load; CPL = Centre Point Load Elastic limit guaranteed: 320.00N/mm²; Max shear load: 25.00kN; Max bending moment: 32.30kNm. 9 PLETTAC METRIX Component Capacities

9 Rosette Coupler The rosette coupler is suitable to transfer longitudinal forces as well as vertical and / or horizontal shear forces into scaffolding tubes or vertical standards. Maximum torque in the link between the coupler and the 48.30mm tube is limited to 50.00Nm. The stated safe working loads can be transferred from the connected component via the rosette coupler to the standard. It is in this case, not relevant whether the component is connected to either the large or small hole. COMPONENT CAPACITIES The longitudinal force N is a tensile or compressive force in opposite ledgers. Only the tensile force is critical. Allowable N = + 20.00kN The vertical shear force Vz represents the reactive force for s. The max. allowable shear force for a single ledger or is: Allowable Vz = ± 8.00kN This value is also valid for a side bracket connected at one side. The sum of the vertical shear forces transferred by several components into one rosette may not exceed: Allowable ΣVz = ±16.00kN Using small ledgers as brackets a bending moment as well as a shear force has to be transferred (M=V Z *e) Allowable M = 0.56kNm Allowable Vz 7.00kN The vertical braces reinforce the scaffolding and determine significantly its load bearing capacity. In case of a connection to a rosette coupler the following loads may be considered for either compressive or tensile loading. Allowable N V = ± 5.00kN 2016 10

www.tradhireandsales.co.uk Contacts Head Office TRAD House Cromwell Road Bredbury Stockport SK6 2RF Tel: 0161 494 2999 Fax: 0161 494 2991 Glasgow Depot TRAD Wharf 244 Bernard Street Glasgow G40 3NX Tel: 0141 550 3666 Fax: 0141 550 3777 London Depot Renwick Road Barking Essex IG11 0SB Tel: 020 8517 1212 Fax: 020 8517 1213 Stockport Depot TRAD House Cromwell Road Bredbury Stockport SK6 2RF Tel: 0161 430 4666 Fax: 0161 430 4777 Leeds Depot TRAD House, Unit 1b 16 Cross Green Way Cross Green Industrial Estate, Leeds LS9 0SE Tel: 0113 249 9555 Fax: 0113 249 4555 Birmingham Depot TRAD House Brickhouse Lane West Bromwich West Midlands B70 0DY Tel: 0121 522 2333 Fax: 0121 522 2335 Andover Depot 58 Whittle Road West Portway Industrial Estate Andover, Hampshire SP10 3FB Tel: 01264 350 505 Fax: 01264 350 515 FS 614991 Edition 3, May 2016