SECTION GUTTERS AND DOWNSPOUTS

Similar documents
NRM-7000 Guide Specifications

by Rollfab Metal Products

ALUMABOARD SECTION ALUMINUM SIDING AND SOFFITS. A. Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

SECTION ORNAMENTAL ALUMINUM RAILING

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

Architectural Roof & Wall Products Guide Specifications MANUFACTURER KLOECKNER METALS KALAELOA BLVD, KAPOLEI, HI 96707,

SECTION METAL WALL PANELS

SECTION EXTERIOR GRILLS AND SCREENS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION METAL ROOF AND SOFFIT PANELS

SECTION STAINLESS STEEL WALL PANELS

CS-100 Guide Specifications

SECTION PREHUNG WOOD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION ROOF EDGE SAFETY RAILING SYSTEM

SECTION TURBINE VENTILATORS

SECTION PRE-ENGINEERED EXTRUDED ALUMINUM DECKING WALKWAY COVERS SPECIFICATION

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

SECTION CONCRETE ROOF TILE

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

SECTION AWNINGS

Architectural Roof Products Guide Specifications

SECTION ORNAMENTAL ALUMINUM RAILING

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

SECTION ALUMINUM WINDOWS

Architectural Wall Products Guide Specifications

SECTION ORCHESTRA PIT FILLER

Trex Commercial Products page Metal Railing

Product Guide Specification

Architectural Roof Products Guide Specifications

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS

SECTION PERFORATED METAL. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

Architectural Roof and Wall Products Guide Specifications

North Hanover Township School District North Hanover Township, New Jersey

University of New Hampshire Scholars' Repository

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

Division 8 Section "Flush Wood Doors" for louvers in wood doors. Division 15 Sections for louvers that are a part of mechanical equipment.

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.

Specifications for FL-100 Soffit Panel

TerraClad TM General Specifications

Sheet Metal Flashing and Trim

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

SECTION PRE-ENGINEERED BUILDING INSULATION

A. Atlantic Railing Series with Mushroom Top and Square Pickets

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

DL-200. Specifications

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION INDUSTRIAL ACCESS / INSPECTION HATCH. A. Industrial Access / Inspection Hatch: Model AH-710

SECTION VERTI-LOK - PREFORMED STANDING SEAM ROOF PANELS

Architectural Roof and Wall Products Guide Specifications

SECTION METAL ROOF & WALL PANELS

Skyline Sheet Metal, Inc.: SSMXRS Pressure Equalized Rainscreen Wall Cladding System

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

Phenolic Exterior Wall Cladding

SECTION SEM-LOK - PREFORMED STANDING SEAM ROOF PANELS

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

SECTION RESIDENTIAL OVERHEAD DOORS IMPRESSION STEEL COLLECTION STEEL DOORS 5800 SERIES

A. Pre-engineered, pre-finished extruded aluminum Pavilions.

SSL-175. Specifications

SECTION SECURITY PROTECTION PART 1 GENERAL

SECTION STRUCTURAL INSULATED PANELS

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

SECTION EXTERIOR SUN SHADES

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

A. Glass Railing Series with Mushroom Top Cap with Glass Panel Infill.

DIVISION VIII - DOORS AND WINDOWS

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

2004 MASTER FORMAT SECTION Façade Panels

SECTION SOLID SURFACE COUNTERTOPS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

SECTION HVAC GRAVITY VENTILATORS

PRODUCT SPECIFICATIONS

Architectural Roof and Wall Products Guide Specifications

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

SECTION EXPANSION CONTROL

SECTION METAL FLAT LOCK TILE PANELS

SECTION ALUMINUM WINDOWS

RECOMMENDED DESIGN SPECIFICATION

PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS

SECTION BRICK FACED ARCHITECTURAL PRECAST CONCRETE. A. Section Cast-In-Place Concrete: Concrete, reinforcing, anchors, etc.

SECTION EXPANSION CONTROL

Aluminum Component Pipe Railings

Transcription:

SECTION 07712 GUTTERS AND DOWNSPOUTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Gutters and Downspouts. B. Related Accessories. 1.2 RELATED SECTIONS A. Section 07611 - Sheet Metal Roofing. B. Section 07220 - Roof and Deck Insulation. C. Section 07620 - Sheet Metal Flashing and Trim. D. Section 07900 - Joint Sealers E. Section 15160 - Storm Drainage: Connection of downspouts to storm sewer. F. Section 15770 - Floor-Heating and Snow-Melting Equipment: Electric heating cable in gutters. 1.3 REFERENCES A. ASTM B 209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate. B. SMACNA - Architectural Sheet Metal Manual. 1.4 DESIGN / PERFORMANCE REQUIREMENTS A. Conform to applicable code for size and method of rain water discharge. B. American Architectural Manufacturers Association (AAMA) Specification 1405.1 "Specification for Aluminum Raincarrying Systems". C. FHA Minimum Property Standard 4900.1 for One- and Two-Family Dwellings. D. FHA Minimum Property Standard 4910.1 for Multi-Family Dwellings. 1.5 SUBMITTALS A. Submit under provisions of Section 01300. 07712-1

B. Product Data: Manufacturer's catalog data, detail sheets, and specifications. C. Shop Drawings: Prepared specifically for this project; showing dimensions of metal gutters and accessories, fastening details and connections and interface with other products. D. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns. E. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns. F. Manufacturer's Certificates: Certify products meet or exceed specified requirements. G. Manufacturers warranties. 1.6 QUALITY ASSURANCE A. Manufacturer Qualifications: B. Installer Qualifications: Certified and approved installer of the sheet metal roofing manufacturer Englert, Inc. C. Perform Work in accordance with [SMACNA Manual] [CDA Handbook]. 1.7 DELIVERY, STORAGE, AND HANDLING A. Store products in manufacturer's unopened packaging until ready for installation. B. Store products to prevent twisting, bending, and abrasion, and to provide ventilation. Slope stored materials to drain. C. During storage prevent contact with materials capable of causing discoloration, staining, or other damage. 1.8 PROJECT CONDITIONS A. Coordinate installation with installation of adjacent roofing, siding and related materials. 1.9 WARRANTY A. Provide the Manufacturer's Limited 20-Year, pro-rated and non-transferable Warranty covering labor materials. 1.10 COORDINATION A. Coordinate Work with other operations and installation of floor finish materials to avoid damage to installed underlayment and membrane materials. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Englert, Inc., which is located at: 1200 Amboy Ave. ; Perth Amboy, NJ 08861; Toll Free Tel: 800-364-5378; Tel: 732-826-8614; Email: request info (info@englertinc.com); Web: www.englertinc.com B. Substitutions: Not permitted. 07712-2

C. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 COMPONENTS A. Gutters: Aluminum sheet, ASTM B 209, Alloy 3105-H24. Minimum tensile strength 26,000 psi, minimum yield strength 25,000 psi or equivalent. Continuous and seamless sheet aluminum, roll formed. a. 0.027 inch (0.69 mm). b. 0.032 inch (0.81 mm). B. Downspouts: Aluminum sheet, ASTM B 209, Alloy 3105-H24. Minimum tensile strength 26,000 psi, minimum yield strength 25,000 psi or equivalent. a. 0.019 inch (0.48 mm). 2. Size: a. 3 inches by 4 inches (76 mm by 102 mm). b. 2 inches by 3 inches (51 mm by 76 mm). C. Endcaps: Aluminum sheet, ASTM B 209, Alloy 3105-H24, thickness 0.027 inch (0.69 mm). D. Inside and Outside Mitres: Aluminum sheet, ASTM B 209, Alloy 3105-H24, thickness 0.027 inch (0.69 mm). E. Gutter Hangers and Anchors: Aluminum sheet, ASTM B 209, Alloy 3105-H24, thickness 0.063 inch (1.60 mm). Provide types required to suit project requirements. F. Downspout Anchors: Aluminum. Provide types required to suit project requirements. G. Elbows: Aluminum sheet, ASTM B 209, Alloy 3105-H24. Minimum tensile strength 26,000 psi, minimum yield strength 25,000 psi or equivalent. a. 0.019 inch (0.48 mm). 2. Size: To match downspouts. H. Gutter Guard: 1. Size: a. Aluminum mesh, 5 inch (127 mm) by 3 foot (914 mm). b. Aluminum mesh, white, 5 inch (127 mm) by 3 foot (914 mm). c. Aluminum mesh, 6 inch (152 mm) by 3 foot (914 mm). I. Gutter Screen: 1. Size: a. Aluminum screen, brown, 5 inch (127 mm) by 3 foot (914 mm). b. Aluminum screen, white, 5 inch (127 mm) by 3 foot (914 mm). J. Aluminum Finish: CastleClad, two-coat system applied in a continuous baked-on process in a single operation, comprising of an acid-based primer and baked-on high performance linear polyester topcoat on exposed surfaces. Concealed surfaces finished with a polyester gold backer or wash coat. 1. Color: a. Lo Gloss White. b. Brown. c. Musket Brown. 07712-3

d. Light Gray. e. Clay. f. Hi-Gloss White. g. Cream. h. Dark Gray. i. Dark Green. j. Red. k. Bronze. l. Eggshell. m. Ivory. n. Wicker. K. Sealant: Provide as specified in Section 07900. L. Fasteners: Same material and finish as gutters and downspouts. 2.3 FABRICATION A. Continuously form seamless gutters to the profiles and sizes specified. B. Form downspouts of profiles and sizes specified. C. Hem exposed edges of metal. PART 3 EXECUTION 3.1 EXAMINATION A. Do not begin installation until substrates have been properly prepared. B. Verify governing dimensions at building. C. Verify surfaces are ready to receive gutters and downspouts. D. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. 3.2 PREPARATION A. Clean surfaces thoroughly prior to installation. B. Clean and repair if necessary any adjoining work on which this work is in any way dependent for its proper installation. C. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. 3.3 INSTALLATION A. Install in accordance with manufacturer's instructions. B. Install gutters using appropriate hangers to allow normal expansion and contraction. C. Install gutter hangers using two 1-1/4 inch (32 mm) screw shank nails and fastened into solid lumber. D. All gutters shall be in continuous length for each elevation (run). No end laps are allowed. 07712-4

E. Exercise care in placing aluminum in contact with other dissimilar metals or materials that are not compatible with aluminum. F. Providing adequate insulation/separation where ever necessary, such as by painting or otherwise protecting when they are in contact with aluminum or when drainage from them passes over aluminum surfaces. G. Install sealants where indicated to clean dry surfaces only without skips or voids. 3.4 PROTECTION A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before Substantial Completion. END OF SECTION 07712-5