Technology Offer. Ultrafast temperature controlled objective. Keywords. Background. File no.: MI WT-WA

Similar documents
Aluminum / Copper oscillation welding with a 500 W direct diode laser

µ Slide Membrane ibipore Flow

µ Slide Membrane ibipore Flow

Immunofluorescence Confocal Microscopy of 3D Cultures Grown on Alvetex

2-step or indirect immunofluorescence 1. Substrate on which cells are plated: plastic vs. glass; coating vs. non

Instructions. µ Dish 35 mm, high Glass Bottom Grid 500. Material. Attention! Geometry. Shipping and Storage. Using The Lid

Tube Formation Assays in µ-slide Angiogenesis. 1. General Information. Application Note 19

1/2W, 0805 Low Resistance Chip Resistor (Lead / Halogen free)

PROline USB Ultrasonic Testing Instrument and Systems

Labware compatibility report. Directly order at:

PROTECTIVE COATING FOR GRAPHITE ELECTRODES

CONTINUOUSLY TRANSPOSED CABLE

Commercial Drive Auburn Hills MI phone fax

Tube Formation Assays in µ-slide Angiogenesis

Transmission Electron Microscopy (TEM) Prof.Dr.Figen KAYA

Heat Flow Meter HFM 436 Lambda. Analyzing & Testing

The Product and Experiment Guide

Friction, Wear, and Lubrication

Technology for Process Heat Applications. and Solar Field Optimization

MonTech RP 3000 Rapid Plastimeter for Polymers and Natural Rubber

DURATAN. Thermally prestressed tubing of special glass

Tube formation assays in µ-slide Angiogenesis

Ø mm. SYSTEM KAN-therm. High quality for reasonable price TECHNOLOGY OF SUCCESS ISO 9001

Cell Culture, Transfection and Microscopy in one Slide

Cytoplasmic Streaming of a Plant Cell near the Freezing Point

Hitachi Anisotropic Conductive Film ANISOLM AC-7106U

Supporting Information

lumox & x-well Technology

Materials and Methods Materials Required for Fixing, Embedding and Sectioning

lumox & x-well Technology

ATFM 2015 ATFM Sample preparation guide

Department of Microbiology, Lab 016 instructions

MODEL Plasma Cleaner. Simultaneously cleans specimen and specimen holder. Cleans highly contaminated specimens in 2 minutes or less

Microscopy from Carl Zeiss. DirectFRAP. News from the Cell. The New Class of Laser Manipulation for the Analysis of Cell Dynamics

Innovative Hydrogen Storage Solutions for Aerospace Applications

How to perform a Gram Stain. Jasleen Singh

Determination of Material Homogeneity Using Infrared Thermography

Advanced Power Modules with AlN-Substrates Extending Current Capability and Lifetime

ACTIVATION AND FUNCTIONALIZATION OF POLYMERS BASED ON GEOMETRY- INDEPENDENT PLASMA SOURCE CONCEPTS

Fabrication of the Crystalline ITO Pattern by Picosecond Laser with a Diffractive Optical Element

EXTERNAL TEST RESULTS

Sample Preparation 3D Cell Explorer. Version 1.1 July 2015 Sabine Bautz

Heat-Treatment Plants. Carbon

Superthal High power heating modules for customized furnaces and heaters

Chemical Applications Division. ALUTIT Aluminum Titanate advanced ceramics for the nonferrous molten metal industry

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

High Quality. UniPlate. Solar Collectors ENERGY SYSTEMS. Solartechnik Prüfung Forschung

Phosphor Screens. Applications. Features. Taper and glass substrates with phosphor layer.

Instructions. Fuse-It-siRNA. Shipping and Storage. Overview. Kit Contents. Specifications. Note: Important Guidelines

BOROFLOAT 33 & Functional Coatings: A Union of Inspiration & Quality

EC medium pressure axial fans. The efficient system solution.

Technical Instructions for Spotting Microarrays

Solar Flat Plate Thermal Collector

The most efficient way of transforming sunlight into heat

SURFACE TEMPERATURE SENSORS

Frequently Asked Questions (FAQ)

UNIVERSAL HOTMELT SYSTEM SOLUTION New Slot Die System Solution for all hotmelt applications

Foundations in Microbiology Seventh Edition

Strain Mapping in Micro- and Nanoscale Fibers

EPX5500 Leeb Hardness Tester

AILU Technology Workshop

The Benefits of a Vertically Integrated Optical Systems Supplier

Sample Preparation. Sample Preparation on TOP TOPwave

Tailor-made Rubber Extrusion. Cable manufacturing lines

Individual Solutions for the Production of High-Quality Self-Adhesive Film / Foil and Paper. Create intelligent solutions.

SIGRAFLEX FOIL. Flexible Graphite Foil Manufactured from Expanded Graphite

T U R B O B L O W E R S

Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks 1

EarthTronics products. About us. Where Efficiency Meets Innovation T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

Headquarter of UV-Technik Speziallampen GmbH in Wolfsberg, Germany

Chapter 4. Sample preparation

International Fireproof Technology, Inc.

Single Motion Actuated Shape Memory Alloy Coupling

Canada 2018 Price List

Temperature Profile Measurement of a Graphite Tube Furnace Using Optical Fibre and Platinum Thermocouples

SEM Exam of Parlex Drilled Hole Samples for GLAST LAT Tracker Flex Cables. Dr. Len Wang/541 Diane Kolos/541 December 1, 2004

Performance Testing and Evaluation Manual for Emission Rate of Formaldehyde from Building Materials The Building Center of Japan

Graphite and C/C Products for Semiconductor & Solar Applications

Gibco media and Thermo Scientific cell culture plastics better together

Sputter-free and reproducible laser welding of electric or electronic copper contacts with a green laser

Packaging Design for Lawrence Berkeley National Laboratory High Resistivity CCDs

EXTERNAL TEST RESULTS

A IR Methods to Evaluate Surface Texture. TRUFASU Aurelian Ovidius 1,a

Reproducible copper welding

1. Carry the microscope in an upright position with both hands and place the base of the microscope 5cm from the edge of the bench

FluidFM INSPIRED BY PRECISION. Subject to change without notice. Revision: 1.3 Copyright 2016 Cytosurge AG, Switzerland

CEMTEC Patented self cleaning gas sampling probe for continuous measurement in any high dust and high temperature process

Multiple-Layer Heat Dissipation Module for LED Streetlamps

INVESTIGATIONS ON THE THERMAL LOAD AND ACTIVE THERMAL LOAD REDUCTION DURING LASER PROCESSING OF CFRP

Evaluation of Bubblers and Baffles for Cooling of Die Casting Dies

Construction of a Seebeck Envelope Calorimeter and Reproducibility of Excess Heat

Large-Scale Delamination of Multi-Layers Transition Metal Carbides and Carbonitrides MXenes

What is the Livecyte system?

Cell Culture Flasks DATA SHEET

Graphite Foam for Cooling of Automotive Power Electronics

novatec HPN engineered graphite with KEVLAR

Twin-Screw Extruder FED-MT

BAUMANN SPRINGS Springs and Stampings for the World.

PALM User Protocols. Laser Capture Microdissection (LCM): Live cells and molecular analysis. Microdissection from Carl Zeiss

Tribological Properties of Hybrid Process DLC Coating against Magnesium Alloy

Transcription:

Technology Offer Ultrafast temperature controlled objective File no.: MI-1401-4735-WT-WA Max-Planck-Innovation GmbH Amalienstr. 33 80799 Munich Germany Phone: +49 (89) 29 09 19-0 Fax: +49 (89) 29 09 19-99 info@max-planck-innovation.de www.max-planck-innovation.de Contact Dr. Wolfgang Tröger Phone: +49 (89) 29 09 19 27 troeger@max-planck-innovation.de Keywords Microscopy of biological samples, fast temperature change. Background In microscopy, especially when working with biological material, it is important to ensure a stable temperature within the sample. For example living cells require a constant temperature of 37 C in order to allow for studies under native conditions. Usually, this is done by using heating chambers or open heated microscope stages where the whole sample can be heated to any desired temperature as shown in figure 1. Figure 1: Live-cell imaging chamber and controlled environ-ment microscope incubator. Another solution is provided with delta T dishes by the company Biotechs. This system uses ITO coated glass slides, which are heated by an electrical current as shown in figure 2, providing an almost homogeneous temperature over the whole glass surface.

Figure 2: Biotechs Delta T4 live-cell imaging chamber configuration Oil immersion microscopy In high-resolution microscopy, oil immersion objectives are used, where the sample is directly coupled to the objective via a drop of immersion oil to create a higher numerical aperture. However, this connection generates a thermal coupling between the sample and the whole microscope, which drains the heat from the sample and thus causes a thermal gradient with its peak right at the field of view and thus the region of interest. In figure 5) a heated ITO glass slide is shown in combination with an infrared camera. When such a glass slide is brought in contact with an oil immersion objective a strong drop in temperature right at the contact surface is observed (Figure 5e). In order to compensate for this effect, objective heaters were developed, where a heating source is wrapped around the objective in order to adjust a desired temperature in the objective (Figure 3). As the objective is also thermally coupled to the whole microscope a huge mass has to be heated, which takes a long time. Figure 3: Objective heater designs for live-cell imaging In order to reduce this heating or cooling time, the objective can be thermally decoupled from the microscope using an isolating ring as implemented by Zeiss (Figure 4).

Figure 4: Zeiss objective including an isolation ring, thermally decoupling the upper part and the lower part of the objective. This reduces the mass, which has to be heated, but the time needed to heat or cool the objective to the desired temperature still remains on the order of several minutes. Technology Here, we present a new type of temperature controlled oil immersion objective, which can nearly instantly change the temperature within the sample contact surface and thus the field of view. It is an objective with a conductive nano-coating at the outer surface of the lens heated by an electric current. This objective allows fast heating or cooling processes during observation of the specimen. A temperature change rate of 20 C per second for heating or cooling the sample could be demonstrated. Using this objective, not only a desired temperature in the sample can be adjusted nearly instantly, also fast temperature changes in the specimen can be induced. If it is necessary to heat the whole sample, this objective can also be used in combination with an already existing heating chamber or heating stage, which was described above. For instance, when working with living cells, the whole cell chamber can be held at 37 C while right at the field of view - which is contemporary the region of interest - a fast temperature change can be induced and it's effect can be observed without affecting the rest of the sample.

Figure 5: Temperature distribution of a heated ITO cover glass with and without contact to an oil immersion objective. An ITO coated cover glass was connected to copper stripes on an isolated aluminum plate containing a hole in the middle (Figure 5 a, b). The surface temperature was recorded using an infrared camera (Figure 5 c). Without any contact with the oil immersion objective the cover glass shows a nearly homogeneous temperature distribution at the center (Figure 5 d). The temperature gradient towards the outer ring occures due to the cold aluminum plate. Bringing the oil immersion objective in contact with the cover glass leads to a strong decrease in temperature right at the contact surface (Figure 5 e). In order to perform a proof of principle of the idea of a new objective with fast dynamic temperature control we executed the following experiments. Proof of principle An aluminum block was built with the same size of a Zeiss objective. This aluminum device represents the objective. The surface of the tip of the aluminum device was coated with an electrically non-conductive varnish. Two copper foils were glued on top of the aluminum cylinder and a round ITO cover glass was glued upside down on the copper stripes. This objective model fulfills perfectly the desired thermal properties as described before.

Figure 6: Aluminum objective model containing a round ITO cover glass with a diameter of 4mm. In figure 7 the possibility of fast heating and cooling using such a nano coating is shown. An ITO coated glass plate with 4 mm in diameter was placed on a cooled aluminum plate of 9. An electrical current was applied for 3 seconds and removed after-wards leading to fast increase in temperature and due to the cold aluminum plate to a fast decrease when the current was removed. Figure 7: Heated ITO glass plate (4mm diameter) underneath a uncoated cover glass (22 x 22 mm 2 ). The whole setup was placed on an aluminum plate, which was cooled down to about 9 C. Heating current was switched on for 3 seconds. Temperature was recorded using a Flir i3 infrared camera.

Advantages An objective with a conductive nano-coating at the outer surface of the lens performs fast heating or cooling processes during observation of the specimen. The temperature change rate is about 20 C per second. The final temperature (e.g. 37 C in cell experiments) can be adjusted almost instantly. The user has not to wait anymore till the objective and the thermally connected microscope are heated up. Note that any existing oil immersion objective can be upgraded with such a coating. Any existing oil immersion objective can be upgraded with such a coating. Such an objective enables new experiments. For instance the reaction of cells to fast changing temperatures via fluorescent-stained proteins can be directly observed, (heat shock proteins, focal adhesion complexes, etc.) Also diffusion dynamics in lipid bilayers due to local changes in temperature can be investigated currently a topic of great interest. Patent information Patent application filed November 2013.