AGRICULTURAL MINERAL SOIL ADDITIVES FOR PASSIVE NITRATE REMOVAL

Similar documents
2017 Onsite Wastewater Mega-Conference Concurrent Session Abstracts Tuesday, October 24, Track: Technical Nitrogen

Nitrogen Removal with the Waterloo Biofilter

A Hybrid Constructed Wetland System for Decentralized Wastewater Treatment

PERFORMANCE EVALUATION OF IN-TANK PASSIVE NITROGEN REDUCTION SYSTEMS (PNRS)

Passive, Two-stage Nitrogen Reduction Systems for Onsite Wastewater Treatment

NALMS 2003 Protecting Our Lakes' Legacy

Upgrading Lagoons to Remove Ammonia, Nitrogen, and Phosphorus *nutrient removal in cold-climate lagoon systems

Year One Sewage Treatment Results

Presentation Outline

Year One Sewage Treatment Results

Nitrogen Removal Using Saturated Upflow Woody Fiber Media

Performance of Passive Wastewater and Groundwater Nitrex TM Nitrogen Removal System. Pio Lombardo

DESIGNING LAGOON-BASED WWTP FOR <1 MG/ L AMMONIA (AND TN) IN <34 F WATER. Nick Janous Regional Manager

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES

Constructed Wetlands

The difference in unit processes for a traditional on-lot wastewater treatment system compared to the AdvanTex Treatment System

Wastewater Nitrogen Characteristics, Treatment and Removal Options. Bob Smith, Orenco Systems, Inc. GEC 2013

WASTEWATER TREATMENT. Nelson Environmental Inc. Nelson Environmental Inc.

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis

THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM

Observed infiltration and clogging characteristics for tested media.

Phosphorus treatment in onsite septic systems

State of the Technology

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection

HOW TO SELECT SRT. SRT is selected based on the following treatment requirements/objectives:

A SUBMERGED ATTACHED GROWTH BIOREACTOR FOR DECENTRALIZED WASTEWATER TREATMENT

Up-Flow Filtration for Wet Detention Ponds

Increasing Denitrification in Sequencing Batch Reactors with Continuous Influent Feed

Biological Wastewater Treatment Processes II: MBBR Processes

NITROGEN REDUCTION IN RECIRCULATING BIOFILTER TREATMENT CONCEPTS. David Venhuizen 1

ONSITE TREATMENT. Amphidrome

NITROGEN REMOVAL GRANT WEAVER, PE & WWTP OPERATOR PRESIDENT THE WATER PLANET COMPANY. Create Optimal Habitats

Bio-Lair for Water Remediation

NITROGEN REMOVAL USING SATURATED UPFLOW WOODY FIBER MEDIA. Larry D. Stephens, P.E. 1

Nitrogen Treatment in onsite septic systems The Big Picture

TABLE OF CONTENT SECTION I. ABSTRACT... x SECTION I MOVING BED BIOFILM REACTOR VERSUS BIOLOGICAL AERATED FILTRATION... XII

Removal of High C and N Contents in Synthetic Wastewater Using Internal Circulation of Anaerobic and Anoxic/Oxic Activated Sludge Processes

CHAPTER 4 WASTEWATER CHARACTERISTICS WASTEWATER FLOWS

OPTIMIZATION OF AN INTERMITTENTLY AERATED AND FED SUBMERGED MEMBRANE BIOREACTOR

Contents General Information Abbreviations and Acronyms Chapter 1 Wastewater Treatment and the Development of Activated Sludge

1/11/2016. Types and Characteristics of Microorganisms. Topic VI: Biological Treatment Processes. Learning Objectives:

Feel free to contact me should you require any additional information regarding the report. I can be reached at

Available online at I-SEEC Proceeding - Science and Engineering (2013)

Demonstration of IFAS Technology for Cold Temperature Nitrification in Lagoon WWTFs at Clare and Ludington, Michigan

Treatment performance of advanced onsite wastewater treatment systems in the Otsego Lake watershed, 2009 results update 1

TWO YEAR CASE STUDY OF INTEGRATED FIXED FILM ACTIVATED SLUDGE (IFAS) AT BROOMFIELD, CO WWTP West 124th Street Broomfield, CO 80020

ETV Joint Verification Statement

with sewage effluent Nutrient enrichment ( Eutrophication ) Algal Blooms Deaeration of the watercourse oxidation of ammonia a potable.

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL

Lagoons Operation and Management in New Brunswick

CTB3365x Introduction to Water Treatment

ALTERNATIVE DRY RETENTION POND DESIGN FOR ENHANCED NITROGEN REMOVAL. Evan Shane Williams, Ph.D., P.E.

The use of aeration in VSSF to reduce land area requirements in CWs

Secondary Treatment Process Control

EHS SMART-Treat Onsite Moving Media Treatment System

Improving Septic Tank Performance by Enhancing Anaerobic Digestion NOWRA Onsite Wastewater Mega-Conference

Preparing for Nutrient Removal at Your Treatment Plant

Bloomingdale WWTF Private/Public Partnership Works. Bob Wilcox, PE Fleis & VandenBrink May 10, 2016

REUSE QUALITY EFFLUENT FROM RESTAURANT WASTEWATER James Bell 1, Chris Duhamel 2 and Sheryl Ervin 3

Onsite Nitrogen Removal

operation of continuous and batch reactors. Contrary to what happens in the batch reactor, the substrate (BOD) of the wastewater in the continuous rea

WASTEWATER 101 Fo r MOWA

/ Marley MARPAK Modular Biomedia /

WASTEWATER TREATMENT SYSTEM MANUAL

We Know Water. AnoxKaldnes. Moving Bed Biofilm Reactor (MBBR) Integrated Fixed-Film Activated Sludge (IFAS) and ANITA Mox Deammonification

On-site Wastewater Treatment System Environment Discharge Performance Appraisal

Analysis of Residential Subsurface. SF constructed wetlands. Performance in Northern Alabama

REMOTELY MONITORED AND E-CONNECTED ADVANCED ON-SITE WASTEWATER TREATMENT NETWORK

2017 Annual Performance Report

CE 370. Wastewater Characteristics. Quality. Wastewater Quality. The degree of treatment depends on: Impurities come from:

MBBR Wastewater Treatment Processes

Packaged Wastewater Treatment Systems for Individual Homes and Small Communities. Mark Gross Orenco Systems, Inc. Sutherlin, OR USA.

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

Probabilistic Modeling of Two-Stage Biological Nitrogen Removal Process: Formulation of Control Strategy for Enhanced Process Certainty

MARPAK modular biomedia WASTEWATER TREATMENT

WASTEWATER FROM CARBON CAPTURE SPECIAL CONSIDERATIONS FOR WASTEWATER TREATMENT

WASTEWATER TREATMENT SYSTEM

Nitrification at elevated temperatures is no problem for a refinery MBBR

NITROGEN REMOVAL OPTIMISATION FROM COMPLEX WASTEWATER

SECTION 6.0 NEWPCC CENTRATE TREATMENT

Efficient Design Configurations for Biological Nutrient Removal

Module 11 : Water Quality And Estimation Of Organic Content. Lecture 14 : Water Quality And Estimation Of Organic Content

Energy Efficient Wastewater Treatment. Emily Gonthier & Jennifer Lawrence April 30, 2018

ENGINEERING OWTS FOR NUTRIENT REMOVAL. Simon Farrell, PE, REHS JVA Consulting Engineers March 27, 2015 CPOW mini conference

Dundalk Wastewater Treatment Plant

BASICS OF WASTEWATER TREATMENT

Traditional Treatment

Best Practice in Sewage and Effluent Treatment Technologies

Stonecrest Estates Sewage Treatment Plant 2017 Annual Report

HARNESSING THE POWER IN NITRIFYING SAND FILTERS

COLD WEATHER NITRIFICATION OF LAGOON EFFLUENT USING A MOVING BED BIOFILM REACTOR (MBBR) TREATMENT PROCESS

Integrated Treatment Options for Meeting Stringent Selenium Regulatory Limits Using Anaerobic Bioreactors

ENHANCED BIOLOGICAL PHOSPHORUS REMOVAL WITHIN MEMBRANE BIOREACTORS. 255 Consumers Road Toronto, ON, Canada, M2J 5B6

Triplepoint Environmental

Andrea Nifong, World Water Works (formerly HRSD) Stephanie Klaus, VT & HRSD

Enhanced Nutrient Removal by Extended Aeration. Christina Edvardsson MicroSepTec, Inc

Treatment performance of advanced onsite wastewater treatment systems in the Otsego Lake watershed, 2008 results

Representative Nitrogen Removal Project Descriptions

METHANOL DOSING TRIAL FOR ENHANCED DENITRIFICATION AT LILYDALE STP. Frank Murphy. Frank Murphy,Process Engineer, Yarra Valley Water

Transcription:

AGRICULTURAL MINERAL SOIL ADDITIVES FOR PASSIVE NITRATE REMOVAL Christopher Jowett 1, Chris James 1, Sean Andrews 1, Craig Jowett 1 & Andy McKinlay 1 ABSTRACT Processes for removing sewage nitrogen at the individual residential scale must be lowmaintenance with only annual service visits. A passive autotrophic process using a 50-50 mixture by volume of: (a) agricultural sulfur for nitrate reduction, and (b) limestone for ph adjustment, in an upflow configuration, was field-tested at 8 34 hours hydraulic retention times (HRT) at one site and at 14 hours HRT at another. An HRT of 8 12 hours was found to be the minimum without substantial nitrate breakthrough; ph was fully neutralized and little BOD and TSS addition resulted. The positive correlation of mass of sulfate formed versus mass of nitrate + oxygen removed reflects a simple stoichiometry, though possibly requiring ammonium to be included. Intercepts near the origin suggest that gypsum is not precipitated. Keywords Nitrogen Removal, Waterloo NOx-LS, Residential Scale, Sewage, Passive Upflow Reactor INTRODUCTION Removal of nitrogen (N) from individual sewage systems is desirable where residences are near saline estuarine water bodies, or on groundwater aquifers. Soil is the receiving body for on-site system dispersal, and a basic need is successful treatment and acceptance into the soil itself to minimize surface breakout of septic tank effluent, which otherwise enhances the nutrient content of stormwater runoff. This is especially important in clay soil where raised beds are prone to surface breakout. Nitrate forms in the leach field, but then is typically non-reactive in soils, and therefore must be removed before entering the natural soil environment. For pre-treatment of nitrogen, the process must require simple, infrequent maintenance, be robust, and be cost-effective. Most of these denitrification processes include recirculation of treated effluent back to the septic tank, or directing treated effluent through a reducing filtration medium, including wood chips and sulfur pastilles (e.g., Oakley, 2005; Hirst and Anderson 2015; Heufelder et al., 2017). NITROGEN REMOVAL BY REACTIVE AGRICULTURAL MINERALS Following recent work of other researchers (e.g., Anderson and Hirst, 2015, 2017; Hirst and Anderson, 2015; Jowett, 2017) experiments were done with autotrophic denitrification using the agricultural minerals limestone and natural sulfur, in a submerged, up-flow configuration, termed the Waterloo NOx-LS. Historical reports of problems using sulfur were likely due to incorrect design or use, and the present testing has determined design configurations and maintenance frequencies, revealed geochemical reactions and demonstrated sustainable performance. 1 Waterloo Biofilter Systems Inc., PO Box 400, Rockwood ON Canada N0B 2K0

Case Study 1: Rural School & Community Centre Process Train: Nitrate-rich effluent from a Waterloo Biofilter absorbent tricking filter servicing a school and community centre in Ontario was passed through a 210 L submerged upflow NOx-LS (limestone + sulfur pastilles) unit followed by a submerged upflow limestone chip Polisher in a 22-month field test. Samples of influent and effluent were taken twice monthly and analyzed for ph, dissolved oxygen (DO), temperature, cbod, TSS, TKN, NO2,3-N, 2 sulfate, and alkalinity. Different loading rates of 60 240 L/day were used, giving hydraulic retention times (HRT) of 8 34 hours using estimated 40% pore volume. Analytical Data: Raw sewage at schools is typically weak in cbod but with moderately strong TKN (Table 1), so recirculation generally removes only ~50% TN. The NOx-LS can be added before or after installation to remove >95% TN if the system is nitrifying well. Sewage temperature ranged from 4.8 to 19.9 C during the test period. The Waterloo Biofilter nitrified septic tank effluent to TKN < 2 mg/l, and removes 48% of the initial raw sewage nitrogen with ~60% recirculation ratio of treated effluent back to the septic tank. Waterloo Biofilter effluent temperature ranged from 6.6 to 21.8 C during the test period. The system tested lowered Waterloo Biofilter NO2,3-N down to < 2 mg/l, and lowered DO to < 1 mg/l. A neutral ph was maintained and cbod was elevated slightly over the nitrified effluent, most likely due to autotrophic bacteria growth. NOx-LS effluent temperature ranged from 8.9 to 24.3 C during the test period. The Polisher removes residual cbod, and final effluent has neutral ph with TN = 4 mg/l, with cbod and TSS both < 5 mg/l. Polisher effluent temperature ranged from 7.7 to 24.8 C during the test period. Table 1. Influent sewage TKN is thoroughly nitrified in the Waterloo Biofilter trickling filter and nitrate is then reduced to nitrogen gas in the submerged NOx-LS reactive filter. Any excess cbod or TSS is then removed in the Polisher. Arithmetic means; N = 25 39. ph DO cbod TSS TKN TN (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) Raw Sewage 7.13 1.10 124.0 41.9 66.9 66.9 Waterloo Biofilter 7.12 7.53 4.4 2.1 1.7 34.5 NOx-LS 6.95 0.93 9.3 2.7 1.7 3.6 Polisher 7.00 1.08 4.4 2.4 2.1 4.0 Removal of 88% and 94% TN was obtained from the Waterloo Biofilter and raw sewage values, respectively, including the low HRT periods with high TN effluent. With the low TKN = 1.7 mg/l in the Biofilter effluent, an average of TN = 3.6 mg/l was attained in the Nox-LS, with 2.2 mg/l TN for HRT > 10 hours and 1.0 mg/l TN for HRT > 15 hours, down from an average TKN = 66.9 mg/l in raw sewage (Figure 1). The average NO2,3-N loading rate for the test period is 13.2 g/m 2 /day. 2 Note: cbod, TSS, TKN, NO2,3-N is carbonaceous biochemical oxygen demand, total suspended solids, total Kjeldahl nitrogen, nitrite-n + nitrate-n, respectively. 2

Total Nitrogen mg/l 1000.0 Biofilter TN NOx-LS TN Raw Sewage TKN 100.0 10.0 1.0 0.1 0 100 200 300 400 500 600 700 Days Lapsed Figure 1. Graphical presentation of the data points gathered along the NOx-LS treatment train pathway. Essentially all NO2,3-N is removed to non-detectable with HRT > 10 hours, but substantial (> 10 mg/l) NO2,3-N breaks through at HRT = 8.4 hours (also see Table 3). The cbod increased from 4.5 to 9.3 mg/l in the NOx-LS effluent, irrespective of HRT, with ph and TSS remaining similar at ~7 units and ~3 mg/l respectively. The NOx-LS effluent is polished to cbod = 4.4 mg/l in the subsequent Polisher filtration module. Operative Reaction: Analyses of nitrite, nitrate, DO, and sulfate were taken before and after the NOx-LS upflow filter to determine a stoichiometric relationship. Figure 2 shows the best fit is obtained by relating mass of sulfate produced versus the mass of NO2,3 + DO removed (laboratory values of NO2,3-N must first be changed to NO2 + NO3 ions). The simple relationship; 2.5 S 0 + CO2 + NO3 + H2O + 2.5 O2 = CH2O + 1/2 N2 + 2.5 SO4 Eq. 1 was used as a base as it includes the parameters measured in this work. The slope of a curve following Equation 1 would be; Slope = SO4/(NO3 + DO) = 96/56.8 = 1.69 Eq. 2 The slope of the curve from the data in Figure 2 is 1.43, not very dissimilar to the theoretical 1.69 and intersects the vertical at 9.3 g/day SO4. The positive intersection indicates that gypsum is not being produced, but may indicate that excess SO4 is being leached from the limestone in the NOx-LS unit, or that other parameters, most likely NH4, have to be included in Equation 1. 3

Sulphate Produced g/day 80 60 40 y = 1.43x + 9.32 R² = 0.915 20 0 0 10 20 30 40 50 NO2,3 + DO Removed g/day Figure 2. Linear relationship between mass of sulfate produced and mass of nitrate + DO removed. Slope is 1.43 compared to theoretical 1.69 for very simple stoichiometry. Case Study 2: Test Facility Process Train: In an ongoing test at a commercial test facility, a single-pass Waterloo Biofilter is fed at a constant 1600 L/day with communal residential sewage. The nitrified Waterloo Biofilter effluent is passed through a submerged NOx-LS reactor as above but designed for 14 hours HRT. The denitrified effluent passes through a subsequent submerged upflow Polisher filter of limestone chips designed to remove any excess cbod and TSS from the NOx-LS. Facility staff take composite samples after each of the components. Sewage temperatures range from 10 to 16.8 C during the test period. Analytical Data: The Waterloo Biofilter nitrifies the sewage to a residual TKN = 4.4 mg/l and removes 41% TN from the sewage (Table 2). Values of cbod and TSS are <5 mg/l, and average DO is high at 6.20. During nitrification, alkalinity decreases from 245 mg/l to 74 mg/l and ph decreases by 1.1 units to 6.68. Percent removal TN in the Waterloo Biofilter is substantially lower than in Case Study 1 as there is no recirculation of treated effluent to the septic tank. After passing through the NOx-LS, at an average NO2,3-N loading rate of 17.3 g/m 2 /day, cbod, TSS and TKN are slightly elevated to 6.3, 2.8 and 5.4 mg/l, respectively. DO and TN are decreased to 0.47 and 5.6 mg/l, respectively, and ph is neutralized from 6.68 to 7.23. Alkalinity is produced during removal of nitrate and DO from 74 mg/l to 172 mg/l. 4

Sulphate Produced g/day As designed, the limestone Polisher lowers cbod and TSS to 4.1 and 1.9 mg/l, respectively, and increases ph slightly. Table 2. This full-size residential system nitrifies well even in a single pass with no recirculation, and the NOx-LS thoroughly removes the nitrate + DO received. N = 25 40; for sewage, N = 187 214; T C = 10.0 16.8. ph DO Alkalinity cbod TSS TKN TN (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) (mg/l) Raw Sewage 7.80 -- 245 204 289 52.3 52.6 Waterloo Biofilter 6.68 6.20 74 3.2 4.2 4.4 30.8 NOx-LS 7.23 0.47 172 6.3 2.8 5.4 5.6 Polisher 7.37 0.55 188 4.1 1.9 5.2 5.4 Operative Reaction: Analyses of mass of sulfate produced within the NOx-LS reactor and mass of NO2,3-N + DO removed are plotted in Figure 3. Similar to Figure 2, there appears to be a simple stoichiometry, and in this case, the slope of the curve is 1.78, not far off the theoretical value of 1.69 for Equation 1. The vertical intercept is 11.5 g/day SO4, similar to 9.3 g/day SO4 in Figure 2. 600 500 400 300 200 y = 1.78x + 11.5 R² = 0.920 100 0 0 50 100 150 200 250 300 NO2,3 + DO Removed g/day Figure 3. Linear relationship between mass of sulfate produced and mass of nitrate + DO removed. Slope is 1.78 compared to theoretical 1.69 for very simple stoichiometry. 5

Hydraulic Retention Time Analysis: The performance parameters of the 22-month experiment for Case Study 1 were separated according to HRT values (Table 3). Percent removal was high during startup in the summer even with low influent TN values, and remained consistent during the winter until HRT was lowered to 8.4 hours. Performance, measured by percent TN removal, improved immediately when HRT was increased. Note that at HRT = 8.4 starting April 11 2016, the percent removal decreases substantially, but the mass of TN removed increases substantially due to the higher volume of nitrate-rich sewage passing through it. Similarly the high HRT of 33.6 hours starting July 13 2015 results in high percent removal but a very low mass of nitrogen removed per day as very little volume is passing through the unit. Table 3. The performance parameters are broken down according to HRT values. Percent removal varies with HRT, and likely influent TKN and temperature to some degree, primarily in the thoroughness of nitrification in the Biofilter. TN % HRT Analysis Start Date HRT TKN 1 TN in 2 Temp in TN out TN Δ TN Δ TN (hours) (mg/l) (mg/l) ( C) (mg/l) out N 3 removal g/day N 4 Jul 13 2015 33.6 50.5 14.7 20.5 0.8 6 92.9 0.83 5 Oct 5 2015 22.4 112.0 26.4 15.2 1.1 3 95.8 2.3 3 Nov 16 2015 16.8 55.4 21.9 9.7 1.2 5 92.3 2.5 5 Apr 11 2016 8.4 75.3 54.1 9.7 11.9 3 66.6 8.7 1 May 17 2016 16.8 69.1 47.3 15.8 3.4 14 93.6 5.4 9 Jan 23 2017 22.4 63.9 47.6 8.3 6.0 4 92.4 4.0 4 1 TKN is raw sewage total nitrogen 2 TN in is nitrified Waterloo Biofilter effluent, which averages 52% of raw sewage TN 3 TN out N is number of samples to calculate TN mg/l value 4 Δ TN N is number of samples to calculate Δ TN g/day value Internal Biochemical Reactions: In Case Study 1, pore waters were sampled periodically with suction lysimeters to determine water-rock biochemical reactions as the nitrate-rich water migrates up through the reactive media. Table 4 shows data from April 18, 2017 sampling date and it is clear that reactivity is entirely within the lower part of the upflow filter. Specifically the NOx-LS 10 sample data (actual = 8 inches below surface of the medium) show cbod, TSS, alkalinity, TKN, NH4, SO4, and sulfide are all at their peak values, decreasing before and after. This peak location corresponds with a trough of ph (almost) and the disappearance of nitrate. This information is lost when only influent and effluent values are used, and the actual existence of sulfide and NH4, for example, in the reactions would not be seen. The sharp peak in cbod is possibly due to the biomass of S-reducing bacteria at this location and coincides with the peak in SO4 production, similar to a continuously advancing oxidationreduction roll-front deposit in the mineral deposit world (e.g., Kesler & Simon 2015). Table 4. The internal pore water chemistry shows reactions occurring that cannot be determined by influent and effluent samples alone (data from Glasauer et al., 2017). 6

Samples of the filter medium were also collected and compared to the original unused medium. Example scanning electron microscope (SEM) photographs in Figures 4A and 4B demonstrate the severe solution pitting (100 μm diameter pits) in the inlet area of the media, as expected, with less pitting (and less reaction) further along the flow path. The pastille in Figure 4B is taken from the level NOx-LS 20 in Table 4 and is in the centre of the reactive zone. NO2,3 + DO would be depleted at this level as they react with the sulfur pastilles. Nitrate was effectively depleted within the first 20 cm at HRT > 12 hours. 7

Figure 4A. SEM photograph of pristine sulfur pastille before use (50 μm scale on photograph). Figure 4B. SEM photograph of corroded pastille with caries texture at bottom of NOx-LS, near source of NO2,3 (500 μm scale on photograph). 8

CONCLUSIONS Full-scale on-site denitrification systems using the common agricultural mineral additives of sulfur and limestone have been successfully tested. An HRT of 8 12 hours was found to be the minimum without substantial nitrate breakthrough; ph was fully neutralized and little BOD and TSS addition resulted. Pore water chemistry and SEM work indicate that the water-rock reactions in the upflow, submerged reactor are analogous in physical and chemical attributes to an oxidation-reduction roll-front deposit in the natural environment. As nitrate-rich water advances through the rock, both nitrate and dissolved oxygen are reduced as sulfur is oxidized, with sulfide as an intermediary, temporary reaction product. REFERENCES Anderson D., Hirst J., Otis R., Ursin E. and Smith D. 2014. Full-scale performance of a twostage biofiltration system for reduction of nitrogen. In: Proceedings, NOWRA Annual Conference & Expo, Denver CO, 11 pp. Anderson D. and Hirst J. 2015. Performance evaluation of in-ground passive nitrogen reduction system (PNRS). In: Proceedings, NOWRA Annual Conference & Expo, Virginia Beach VA, 13 pp. Anderson D. and Hirst J. 2017. In-ground nitrogen reducing biofilters for onsite wastewater treatment simple but effective. In: Proceedings, WEF Nutrient Symposium, Onsite and Decentralized Nutrient Removal and Recovery Systems. Fort Lauderdale FL. Glasauer S., Jowett C. and Solntseva I. 2017. Pore water chemistry within NOx-LS reactor. Internal Report SOWC Project. 5 pp. Heufelder G., Meyers C., Mroczka K. and Baumgaertel B. 2017. Investigations of nonproprietary means of nitrogen removal in onsite septic systems using various configurations of lingo-cellulosic material in the soil treatment areas. In: Proceedings, WEF Nutrient Symposium, Onsite and Decentralized Nutrient Removal and Recovery Systems. Fort Lauderdale FL. Hirst J., Anderson D. and Smith, D. 2014. Pilot study of two-stage biofiltration for reduction of nitrogen from OWS. In: Proceedings, NOWRA Annual Conference & Expo, Denver CO, 13 pp. Hirst J. and Anderson D. 2015. Performance evaluation of in-tank passive nitrogen reduction system (PNRS). In: Proceedings, NOWRA Annual Conference & Expo, Virginia Beach VA, 18 pp. Jowett C. 2017. Passive autotrophic denitrification using agricultural mineral filters. In: Proceedings, WEF Nutrient Symposium, Onsite and Decentralized Nutrient Removal and Recovery Systems. Fort Lauderdale FL. Kesler S. E. and Simon A. C. 2015. Mineral Resources, Economics and the Environment. Cambridge University Press, 446 pp. Oakley S. 2005. Onsite Nitrogen Removal Text. in (M.A. Gross and N.E. Deal, eds.) University 9

Curriculum Development for Decentralized Wastewater Management. National Decentralized Water Resources Capacity Development Project. University of Arkansas, Fayetteville AR. 10