Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

Similar documents
easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Agilent 1260 Infinity II LC ASPIRE TO NEW LEVELS OF EFFICIENCY EVERY DAY IN EVERY WAY

Agilent 1260 Infinity II Prime LC ACHIEVE CONVENIENCE EVERY DAY IN EVERY WAY

Agilent 1290 Infinity II LC SET NEW BENCHMARKS IN EFFICIENCY WITH THE NEXT GENERATION OF UHPLC

Agilent 1220 Infinity LC. Infinitely more affordable

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

AGILENT INFINITYLAB. Maximum efficiency for your liquid chromatography workflows

Agilent SD-1 Purification System. Purify your way SD-1

Agilent 218 Purification System. Purify your way

Analytical HPLC solutions

Agilent OpenLAB Chromatography Data System IT S TIME TO ACHIEVE MORE

Performance characteristics of the 1260 Infinity Quaternary LC system

Agilent 1260 Infinity LC & LC/MS Purification Systems. Purify your way

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

Ultivo Triple Quadrupole Mass Spectrometer UNBELIEVABLY POWERFUL REMARKABLY SMALL

Agilent 1260 Infinity Purification Systems. Infinitely better purity and recovery

Agilent InfinityLab LC/MSD Series EXTEND THE BOUNDARIES OF YOUR ANALYSIS

Infinitely better. Agilent 1200 Infinity Series. Infinity LC. Infinity LC. Infinity LC. products applications soft ware services

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Agilent 1290 Infinity 2D-LC Solution. Selectable separation performance

Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC

The LC/MS Walk-Up Solution from Agilent

Automated Purification Software for Agilent OpenLAB CDS

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Gold Standard for recovery and purity

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

Agilent LC and LC/MS Purification Solutions. Purify your way

Agilent MassHunter Walkup Software SIMPLIFIED LC/MS FOR EVERYONE

Agilent 1290 Infinity II LC MORE EFFICIENCY MORE FREE TIME. #EfficientUHPLC

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Agilent 6400 Series Triple Quadrupole LC/MS. Breakthrough sensitivity now routine for your lab

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Agilent OpenLAB CDS. Manage your chromatography better than ever before

Agilent OpenLAB Chromatography Data System COMPLIANCE AND EASE OF USE, TOGETHER AT LAST

INCREASING YOUR LABORATORY PRODUCTIVITY

Agilent solutions for contract research and manufacturing organizations

Agilent 7693A Series Automatic Liquid Sampler Inject new performance into your gas chromatography. Our measure is your success.

Agilent 1290 Infinity Binary LC System with ISET Emulation of a Waters Alliance 2695 LC Applying Concave, Convex, and Linear Gradients

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

ultra why micro-lc? product note introducing the ExpressLC -Ultra system: UHPLC with all the advantages of micro-lc

Comprehensive Service Options for Your Lab

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

Automated alternating column regeneration on the Agilent 1290 Infinity LC

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

Analytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System

Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED.

Method Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC

Authors. Introduction. Experimental. Environmental Analysis

Complete Success Begins with Sample Quality Control. Agilent 4150 and 4200 TapeStation Systems

Agilent CrossLab Services and Support Portfolio TRANSFORM YOUR LABORATORY OPERATIONS

Agilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers

Developing Purification Strategies for the Agilent 1260 Infinity II Preparative LC/MSD System

Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD)

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Application Note. Authors. Abstract. Introduction. Pharmaceutical

Method Translation in Liquid Chromatography

Agilent 1260 Infinity Bio-inert Quaternary LC System. Infinitely better for bio-molecule analysis

Agilent Intuvo 9000 GC System DREAM BIGGER

Agilent 6000 Series LC/MS Solutions. Confidence in Quantitative and Qualitative Analysis

Agilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis. WCBP Jan 2017 Washington, DC

New Advances in UHPLC -Resolution, Speed & Sensitivity

Application Note. Author. Abstract. Pharmaceuticals. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Agilent 1260 Infinity Bio-inert Quaternary LC

Transferring a Method from a Conventional 3.5 µm or 5 µm to an Agilent Poroshell 120 Column to Improve Analytical Speed and Resolution

Agilent 1290 Infinity Quaternary LC Support of Columns with 2.1 to 4.6 mm ID to 1200 bar

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Environmental. Agilent 1290 Infinity Binary LC. with ISET and fine-tuning. Agilent 1290 Infinity Binary LC.

Agilent Professional Services for the Agilent OpenLAB Software Suite IMPLEMENT YOUR OPENLAB SOLUTION FASTER AND MORE EFFECTIVELY

A New Horizon of Performance Agilent G1888 Network Headspace Sampler

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

BÜCHI Labortechnik AG

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma)

Agilent 6430 Triple Quadrupole LC/MS System

ISET. Agilent 1290 Infinity Binary LC with ISET, emulation of the Waters Alliance 2695 LC system analyzing aromatic acids. Application Note.

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Transform Your Laboratory Operations. Agilent CrossLab services and support portfolio

Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Separation Science Built for Biopharma

ACQUITY UPLC. I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

Using Empower SystemsQT Qualification Tool

Agilent OpenLAB Enterprise Content Manager (ECM) THE LABORATORY DATA HUB

Peptide Mapping: A Quality by Design (QbD) Approach

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

The Agilent 6545 Q-TOF LC/MS System. The Answers You Need:

The Agilent 6545 Q-TOF LC/MS System. The Answers You Need:

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Agilent LC Dissolution Software STREAMLINE LC DISSOLUTION ANALYSIS

Automated fraction re-analysis does it really make sense? Application. Udo Huber. Abstract

Magnis NGS Prep System. Your lab s automated library preparation solution for next-generation sequencing

Transcription:

1220 Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

AGILENT 1220 INFINITY II LC AFFORDABLE EFFICIENCY WITH CONFIDENCE Take a close look at the Agilent 1220 Infinity II LC and you ll find everything you need to get you on the fast track to highest efficiency and result confidence all in a high-quality, compact unit at a price you can afford for maximum return on investment. AFFORDABLE ANALYTICAL EFFICIENCY Leveraging proven Agilent LC technology to deliver run-after-run, day-afterday reproducibility for highest confidence in your results. AFFORDABLE INSTRUMENT EFFICIENCY Factory configured and tested to get your lab on the fast track to robust and reliable sample analysis for immediate productivity. AFFORDABLE LABORATORY EFFICIENCY Robust and highly reliable LC quality compatible with all InfinityLab LC Series detectors for full application flexibility and easy upgrade to meet future demands. 2

AGILENT INFINITYLAB A PERFECT MATCH The Agilent InfinityLab family of instruments, columns and supplies are matched to work seamlessly together, alongside Agilent OpenLAB software and Agilent CrossLab services, to provide highest efficiency in laboratory workflows. Agilent InfinityLab columns and supplies provide the links to the Agilent InfinityLab LC Series to optimize performance for highest efficiency and laboratory safety. Learn more: www.agilent.com/chem/1220 3

AFFORDABLE ANALYTICAL EFFICIENCY RUN-AFTER-RUN REPRODUCIBILITY FOR HIGHEST CONFIDENCE IN YOUR RESULTS Leveraging proven Agilent LC technology, the 1220 Infinity II LC delivers run-after-run, day-after-day reproducibility for highest confidence in your results. Precise and reliable solvent delivery The 1220 Infinity II LC pump ensures stable, virtually pulse-free solvent flow up to 10 ml/min. A pressure range up to 600 bar even enables the use of columns with smaller particles for better resolution and faster run times. Choose from different configurations, including either an isocratic or a gradient pump with integrated dual-channel degassing unit. With low internal volumes of 1.5 ml per channel, the degassing unit creates continuous vacuum, eliminating baseline fluctuations and shortening equilibration times. An optional automated solventselection valve for the gradient pump combines two-out-of-four solvents for gradient formation or for column flushing with different solvents. Absorbance [mau] 250 1 225 200 175 2 5 Peak % RSD RT 1 0.149 150 125 100 75 3 4 6 7 8 9 2 0.096 3 0.070 4 0.090 5 0.060 6 0.106 50 7 0.097 25 8 0.073 0 9 0.059 0 0.2 0.4 0.6 0.8 1.0 1.2 Time [min] Six overlaid consecutive analyses of a standard sample using a Poroshell 120 EC-18, 3 x 50 mm, 2.7 μm column with 1 μl injection volume, demonstrating a fast gradient run at 563 bar with retention time precision less than 0.15 % RSD. 4

Fast, reproducible and robust detection Featuring optimized optics for high sensitivity, low baseline drift, wide linear range and 80 Hz data rate, the variable wavelength detector not only lowers your detection limits but also expands your application capabilities. Choose from a range of flow cells with different volumes and path lengths to match the demands of your application. Capable of acquiring spectral data, the diode array detector gives you more confidence in the qualification and quantification of impurities even at trace levels. Low-noise electronics and the detector s 80 Hz data rate guarantee highest sensitivity for conventional or ultrafast LC. Selection of up to 8 signal wavelengths provides for increased selectivity for complex samples. Flow cells with 2, 5 or 13 μl volume are available to match your application s needs. Absorbance [mau] 40 30 20 10 0 0 2 4 6 8 10 12 1 Metamitron 2 Chloridazone 3 Cyanazine 1 2 4 Simazine 5 Prometryn 6 Diuron 4 3 5 6 7 8 7 Propazine 8 Terbuthylazine 9 Chlortoluron 9 14 Time [min] Trace analysis with variable wavelength detector of pesticide residues, showing a limit of detection (LOD) of less than 50 pg. The relative standard deviation is less than 0.08 % for retention times and less than 0.5 % for areas. Rugged, high-resolution separations InfinityLab Poroshell 120 columns provide fast, rugged, highresolution separations at pressures up to 600 bar and perform best with the 1220 Infinity II LC. Within our InfinityLab column family, currently 12 bonded phases are available for flexible development and straightforward transfer of methods (see page 4 for an application example of our InfinityLab Poroshell 120 columns). InfinityLab Quick Connect fittings provide robust, leak-tight connections for every user through innovative spring-loaded design with zero dead volumes even after hundreds of reconnections. InfinityLab columns and supplies match perfectly with our InfinityLab LC Series systems and solutions, taking advantage of the latest innovations to combine ease of use with robust performance, for highest confidence in your daily results. 5

AFFORDABLE INSTRUMENT EFFICIENCY CONFIGURED, TESTED AND READY-TO-RUN FROM DAY ONE Every system is configured and tested at our factory to get your lab on the fast track to robust and reliable sample analysis for immediate productivity. Reliable and straightforward sample handling and injection The integrated autosampler is designed for reliability, safety and easy maintenance, and enables injections from 0.1 to 100 μl. The flow-through design ensures that there is no loss of sample; the entire sample drawn from the vial is injected. The standard full-size sample tray holds up to 100 2 ml vials. Half-size trays are also available, holding 40 2 ml or 15 6 ml vials. Choose any configuration of half- or full-size trays to meet your needs for sample handing and throughput. The easy-to-use manual injector includes a durable injection valve that features ceramic rotor faces for highest reliability and uptime. Supplied with a standard 20 μl sample loop, injection volumes up to 5 ml are possible with optional loops. With the flexibility to manage different sample containers, the autosampler ensures reliable and reproducible injection of your samples. 6

Isocratic Configuration Gradient Configurations Isocratic Pump Gradient Pump Gradient Pump Gradient Pump Manual Injector Manual Injector Autosampler Autosampler...... Column Oven Column Oven Variable Wavelength Detector Variable Wavelength Detector Variable Wavelength Detector Diode Array Detector Integrated, robust and easy to use for easy entry into high-efficiency LC Choose from four integrated all-in-one configurations that include all the components you need to meet the requirements of your LC workflows. To increase instrument efficiency or meet future demands, a wide variety of upgrade paths are available, please see page 8 for more information. Peak Explorer helps you uncover and resolve problems faster. Find anomalies at a glance even among hundreds of chromatograms and peaks. Efficient control, acquisition and reporting Agilent OpenLAB CDS software gives you the most comprehensive and fully traceable management of your 1220 Infinity II LC, including instrument control, result generation, data management and advanced reporting. With OpenLAB CDS, you can visualize data trends quickly, capturing at-a-glance artifacts or outliers such as missing or additional peaks, retention time shifts, or integration problems. Extensive built-in calculations provide results directly in data analysis, without the need to generate a full report and eliminating errors caused by data export or manual transcription. Confirmation and documentation of audit-trail reviews are part of the electronic record within the data system, making it an easy task to comply with the latest FDA regulatory requirements. 7

AFFORDABLE LABORATORY EFFICIENCY REALIZE SEAMLESS INTEGRATION FOR HIGHEST INVESTMENT PROTECTION The 1220 Infinity II LC is a quality instrument that is easy to upgrade and fully compatible with all InfinityLab LC Series detectors for nondisruptive transition to meet future needs within the confines of your budget. Flexibility to meet your current budget and future needs Enhance the performance, productivity and efficiency of your system through upgrade options to meet the increasing demands of your laboratory. Upgrade the pump from isocratic to gradient for higher method flexibility. Upgrade the manual injector with an autosampler for higher sample throughput and pretreatment programming. Upgrade with a column oven for better reproducibility and method development flexibility. Upgrade with an external sample tray for easy sharing of one instrument for LC or even LC/MS analysis. Upgrade the pump with active inlet valves to increase robustness for challenging solvent conditions. Expand your application possibilities by adding any InfinityLab LC Series detector or other module to your system. Add a fluorescence detector (FLD) for analysis of compounds such as aflatoxins. Add a refractive index detector (RID) for analysis of sugars. Add an evaporative light scattering detector (ELSD) for analysis of non-uv absorbing chromophores. Add a multidetector suite (MDS) for advanced GPC. Add a 6100 Series single quadrupole MS for massselective detection. Add a fraction collector for small-scale preparative LC, purification or sample re-analysis. Layoutansicht - Rendering folgt Couple your 1220 Infinity II to any of a wide range of special detectors to meet your application needs. 8

Get the most from your investment Agilent offers comprehensive instrument and enterprise services as well as a full curriculum of Agilent University learning solutions to maximize uptime, simplify administration and protect the investments in your laboratory. Through preventive maintenance, our service plans protect your laboratory against the unknown, for dependable efficiency, fewer workflow disruptions, and optimized laboratory productivity. All service plans include Agilent Remote Advisor, a powerful set of proactive, real-time support and reporting features, delivered by knowledgeable Agilent experts. Simply more value With its space-saving footprint the 1220 Infinity II LC is ideally suited to address the needs of small to mediumsized labs that are mainly tasked with routine analysis. The system delivers all the performance needed to meet stringent regulatory demands while setting the standard for compactness and ease of operation. As part of the InfinityLab LC Series and representing the entry-point system, the 1220 Infinity II LC leverages the latest technology by sharing components with the 1260 Infinity II and 1290 Infinity II LCs. Services Included in All Agilent CrossLab Service Agreements Contract-level Preferred Response vs. T&M Hardware Telephone Support Onsite Repair Services Unlimited Onsite Repair Visits (travel & labor) Parts Required for Repair Consumables/Supplies Required for Repair, including liners, seals, tubing, assemblies, and multipliers Advanced Diagnostics and Reporting Agilent Remote Advisor-Assist Agilent Remote Advisor-Report Agilent Remote Advisor-Alert High-Availability Services Extended Coverage Hours Discount GOLD SILVER BRONZE Agilent CrossLab service plans let you choose the service level that best meets your needs, goals and budget. Regional differences to service plans may apply. Additional options are available. 9

AGILENT 1220 INFINITY II LC WORKFLOW SOLUTIONS INFINITYLAB QUALITY AT YOUR FINGERTIPS In the lab or in the field, our workflow solutions give you the highest operational efficiency where and when you need it. Walk-up solution: Easy access for multiple users Regardless of experience or skills, our walk-up solution gives everyone easy access to powerful LC separation and detection capabilities including LC/MS. The external sample tray provides for easy sample placement. The intuitive walk-up software works perfectly in tune with OpenLAB as well as MassHunter to guide you through sample submission and method selection. Analysis results and reports are sent to your email account. In a multi-user environment, even novice users can take full advantage of advanced LC and LC/MS capabilities without assistance from expert staff. Optimized walk-up solution for simplified and easy access to LC and LC/MS in a multiuser environment. The walk-up software makes sample submission an easy task simply log in, choose method, and place your sample vials in the positions indicated. 10

Mobile solution: InfinityLab quality where and when you need it For mobile labs that need to measure samples at different locations or even remote sites, the Agilent 1220 Infinity II Mobile LC solution provides an ideal configuration for onsite liquid chromatography analysis. A special mounting plate absorbs shocks and vibration during transport or operation. Columns and solvent containers are held firmly in place, preventing instrument damage and maintaining operator safety. Gradient pump with integrated degassing unit, 600 bar, up to 10 ml/min, for reliable and robust analysis. Vial sampler with injector programming. 80 C oven for one 25 cm column. Variable wavelength or diode array detector with 80 Hz sampling rate for highest sensitivity. Attenuation unit available as upgrade for your current instrument. Mobile LC applications range from analysis of non-volatile pesticides in environmental and food applications, through analysis of biofuels, to drug monitoring or testing of counterfeit drugs. It can also be used in teaching, when a mobile laboratory travels to students residing in remote areas. Another application area that has recently gained interest is the authentication of food whereby a mobile LC facilitates direct qualification of imported foodstuffs at airports and harbors. The 1220 Infinity II mobile LC solution offers high reliability and fast analysis even under challenging onsite conditions, making it the ideal LC system for fast response in the field. 11

Learn more www.agilent.com/chem/1220 Find an Agilent customer center www.agilent.com/chem/contactus USA and Canada 1-800-227-9770 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com This information is subject to change without notice. For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies, Inc. 2016 Published in the USA, September 15, 2016 5991-6782EN