J. L. ABRAHAM 1 *, G. SIWINSKI 2 and A. HUNT 1. University of New York, Upstate Medical University, Syracuse, NY, USA

Similar documents
ESTACALAB, Department of Mechanical Engineering, ESTACA, 78180, Montigny-Le-Bretonneux, France, 2

Literature Review of Indoor Ultrafine Particles and Residential Gas Appliances

AIRBORNE PARTICULATE MATTER AT A BUS STATION: CONCENTRATION LEVELS AND GOVERNING PARAMETERS

INDOOR AND OUTDOOR PARTICLE MEASUREMENTS IN A STREET CANYON IN COPENHAGEN

In-vehicle / Out-vehicle air quality and commuter s exposure to pollutants

Wierzbicka, Aneta; Gudmundsson, Anders; Pagels, Joakim; Dahl, Andreas; Löndahl, Jakob; Bohgard, Mats

PRODUCTS OF COMBUSTION

AIR FILTRATION SYSTEM IN AN OFFICE BUILDING: FROM DESIGN TO VALIDATION

Air quality in the vicinity of a governmental school in Kuwait

Application of a Novel Sensor for Traffic-related Indoor Air Pollution

CHARACTERISATION OF PARTICULATE MATTER PM10 AND PM2.5 IN NORTHRHINE WESTPHALIA, SAXONIA AND LITHUANIA FIRST RESULTS

Prabjit Barn Santé et environment: enjeux, rôles et interventions June 3, 2010 Montreal, QC

IMPROVEMENT OF AIR QUALITY IN VEHICLE CABINS BY NANOPARTICLE FILTRATION

Field measurements of PM 2.5 and ultrafine particles in residential houses

PUGET SOUND CLEAN AIR AGENCY CHINATOWN INTERNATIONAL DISTRICT TOXICS STUDY COMMUNITY REPORT

Indoor Air Quality Solutions

Outdoor air and (non-combustion) appliances as sources of indoor particulate matter (PM)

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

Steven L. Alderman, Michael S. Parsons, and Charles A. Waggoner. Institute for Clean Energy Technology, Mississippi State University

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

PREDICTION OF ULTRAFINE PARTICLE CONCENTRATIONS IN VARIOUS INDOOR ENVIRONMENTS

Lecture 4 Air Pollution: Particulates METR113/ENVS113 SPRING 2011 MARCH 15, 2011

BREATHE A LITTLE EASIER WITH TSI

What do we know about particles in the air that we breathe?

Moving to mass-based HVAC filtration metrics

FIRE APPARATUS MANUFACTURERS ASSOCIATION

Impact of traffic composition and street canyon on the street level air quality and pedestrian exposure in Central, Hong Kong

MonitoringofParticulateMatterinDifferentLocationsandImprovementofIndoorAirQualityinRajshahiCityofBangladesh

Examples of sensor applications: mobile monitoring of air quality

5. Health risk assessment of transport-related air pollution

GE 2211 Environmental Science and Engineering Unit III Air Pollution. M. Subramanian

Chile. Extension for other vehicle categories of the labeling of vehicular energy efficiency.

CE 326 Principles of Environmental Engineering Prof. Tim Ellis

Major Air Pollutants

Tunnel Ventilation System Design and Air Quality. Peter Gehrke and Andrew Purchase

Fine Particles in the Air

A. INTRODUCTION B. POLLUTANTS FOR ANALYSIS

CHAPTER 2 - Air Quality Trends and Comparisons

Changes to Air Quality

Aalborg Universitet. Published in: Proceedings of Clima Publication date: Document Version Early version, also known as pre-print

FILTER EFFICIENCY OF SELECTED HVAC FILTERS

Visible emissions were not observed in the school in the vicinity of the construction containment.

What is air pollution?

Particle Measurement Methodology: On-road and laboratory measurements of nanoparticles from Diesel engines

On the Study of the Indoor Environment in Private Residences

Indoor and Outdoor Comparisons of Particle Sizes and Concentrations

Land-Based Gas Turbine Particulate Emissions

MODELING THE SPREAD OF ANTHRAX IN BUILDINGS

The Deposition and Fates of Inhaled Transport Related Particulate Material

SCOEH. Particulate Matter: Identification, mitigation and assessment. Michael Riediker Prof., Dr.sc.nat. Founding Director, SCOEH

Jurnal Teknologi FIELD MEASUREMENT OF PARTICULATE MATTER INSIDE A BUS PASSENGER COMPARTMENT. Full Paper

ASSESSMENT, CLEANING & RESTORATION OF HVAC SYSTEMS (ACR-2002)

Community Environmental Advisory Commission (CEAC) Mitigating Impacts of Outdoor Air Quality on Indoor Air Quality in Berkeley

Air Pollution. tutorial by Paul Rich. Brooks/Cole Publishing Company / ITP

CHARACTERIZATION OF INDUSTRIAL FILTRATION SYSTEMS FOR FINE PARTICLE

Appendix C: GHG Emissions Model

Chapter Overview. Chapter 3: Sources of Air Pollution 3-1. Role of Sources of Air Pollution in an Air Quality Management Program.

Iranian journal of health sciences 2014; 2(1):30-36

Iranian journal of health sciences 2014; 2(1):30-36

Outdoor air and (non-combustion) appliances as sources of indoor particulate matter (PM)

White paper: Indoor air quality and carbon dioxide sensors

Civil Engineering Research Exchange Symposium Session I STRUCTURES AND MATERIALS

6.1 INTRODUCTION 6.2 REGULATORY FRAMEWORK NATIONAL AMBIENT AIR QUALITY STANDARDS COMPLIANCE STATUS TRANSPORTATION CONFORMITY

Illinois Department of Public Health Guidelines for Indoor Air Quality

AIR FILTERS: REAL WORLD PERFORMANCE

4.4 AIR QUALITY Approach to Analysis

COMPARISON OF CONCENTRATIONS OF CARBON MONOXIDE AND DIOXIDE BETWEEN URBAN AND RURAL AREAS AT BASRA CITY IRAQ

Web Seminar. Indoor Air Quality. Indoor Air Quality and Air Cleaning 19 November Peter DYMENT Camfil Ltd

clean air for airports Airports Camfil Farr clean air solutions

Chapter 10. Air Quality

I A Q R O A D S H O W

Leadership in Filtration. ScandMist Industrial air cleaners

Long Term Monitoring of Ultrafine Particles in the Urban Atmosphere

PM1 FINE DUST HAZARD TO HEALTH APAC

CONCENTRATIONS OF PARTICULATE MATTERS(TSP, PM 10, PM 2.5, AND PM 1 ) AND BIOAEROSOL IN THE ABOVE- AND UNDER-GROUND SUBWAY OFFICES IN SEOUL

Public Health Relevance of Air Pollution. IASS, Potsdam 12 th -13 th November, 2018 Maka Maglakelidze IASS Fellow

Aerosol Short Course: Physics, Measurement, and Sampling

Quantification of differences between occupancy and total monitoring periods for better assessment of exposure to particles in indoor environments

MEP's Letter of Assurance

Atmospheric Chemistry Air Pollution

INHALATION INTAKE FRACTION OF POLLUTANTS FROM EPISODIC INDOOR EMISSIONS

The Leader in Performance Indoor Air Quality Measurements

The Leader in Performance Indoor Air Quality Measurements

Household air pollution in South African low-income settlements: a case study

Effects on environmental conditions of constructing a u-turn in East Tehran Highway

DEPARTMENT OF HEALTH & HUMAN SERVICES

Ambient Air Quality and noise Measurements Report Gas pressure reduction station in Marsa Matrouh Governorate

THE IMPACTS OF HUMAN ACTIVITIES ON INDOOR AIR QUALITY IN PASSIVE HOUSES. Ryan Militello-Hourigan, PE Shelly Miller, PhD

Harmonizing the measurement of ultrafine particles in atmospheric aerosol

PM Distance Decay Evidence from CA. Zhu, et. al.

Environmental Air Quality Exposure Assessment in a Rural Nigerian Village

Indoor Air Quality in Naturally Ventilated Italian Classrooms

Particle Counters Could Leave Your Business in the Dust 2019 IAQA Annual Meeting

On the environmental safety of automobile vehicles

Size distribution and number concentration of the 10nm-20um aerosol at an urban background site, Gennevilliers, Paris area

FORUM-AE Workshop 1 Heathrow Airport Particulate Measurements 10th January 2014

Indoor Air Quality Management Plan

REMOVAL EFFICIENCY OF PARTICLES BY COMBINING NEGATIVE IONS WITH MECHANICAL FILTERS

The UK s Leading Ventilation Company. Vent-Axia Pure Air. 1st Edition.

Particulate Monitors and Samplers

Transcription:

Ann. occup. Hyg., Vol. 46, Supplement 1, pp. 406 411, 2002 2002 British Occupational Hygiene Society Published by Oxford University Press DOI: 10.1093/annhyg/mef701 Ultrafine Particulate Exposures in Indoor, Outdoor, Personal and Mobile Environments: Effects of Diesel, Traffic, Pottery Kiln, Cooking and HEPA Filtration on Micro-environmental Particle Number Concentration J. L. ABRAHAM 1 *, G. SIWINSKI 2 and A. HUNT 1 1 Department of Pathology and 2 Central New York Occupational Health Clinical Center, State University of New York, Upstate Medical University, Syracuse, NY, USA We measured ultrafine particulate material (UFPM) number concentrations in a variety of indoor, personal and mobile environments, using a P-Trak condensations particle counter (TSI model 8525). Indoor UFPM levels indicated influx of outdoor air plus indoor combustion sources (e.g. toasting and cooking, yielding UFPM concentrations >500000 particles/cm 3 ). Influx of UFPM into the indoor environment from unexpected sources (e.g. a home pottery kiln) was readily detected. In a moving passenger car environment, prolonged exposures to UFPM concentrations >100000 particles/cm 3 were observed related to heavy traffic, especially diesel vehicles. Data logging at 1 s revealed transient UFPM peaks not demonstrable with longer interval averaging. Indices of continuous, average and cumulative exposures are presented. This type of sensitive and portable instrumentation should be highly useful in studies of UFPM in mobile and personal micro-environments. Keywords: cooking; diesel; filtration; pottery kiln; ultrafines INTRODUCTION Ultrafine particles, which are defined as particles <0.1 µm in diameter, are on a mass basis only a minor component of the atmospheric aerosol ( 1% by weight), but on a number basis they are a major constituent ( 86% by count). Ultrafine particles can be generated by a variety of urban/industrial processes, although some specific emitters are recognized as major sources of ultrafines (e.g. diesel vehicles). Toxicological studies suggest that ultrafines have the potential to reach both the upper and lower respiratory tract and to produce adverse health effects. It has been shown that ultrafine particles produce inflammatory effects in the lung that may be the result of oxidative stress. In this study we have utilized a new portable ultrafine particle counter to measure the concentrations of ultrafine particles in numerous environments. *Author to whom correspondence should be addressed. e-mail: abrahamj@upstate.edu MATERIALS AND METHODS A P-Trak condensation particle counter (TSI model no. 8525) was used to assess the number concentration of ultrafine particulate material (UFPM) in various environmental situations. This portable instrument grows UFPM in a chamber containing supersaturated alcohol vapor and subsequently counts them using a laser. Concentrations are measured from 0 to 500000 particles/cm 3 for particles in the size range 0.02 >1.0 µm. Data logging at intervals as short as 1 s facilitates observation of rapid fluxes in UFPM concentrations. This instrument does not measure particle size or chemical composition. Cumulative sampling duration was >200 h, and peak, average and cumulative exposures were examined. RESULTS We operated the P-Trak as a mobile and personal sampler under a variety of exposure conditions. Indoor counts ranged from zero at the outlet of a HEPA filter unit to several hundred particles/cm 3 in the home at baseline (Figs 1 and 2). Counts in the 406

Filtration and particle number concentration 407 Fig. 1. Effect of a HEPA filtration unit in a residential home bedroom. Fig. 3. Point source UFPM, decay and toaster UFPM dispersion. Fig. 2. Kitchen cooking effects on UFPM concentration. A typical sampling run. (1) 7:38 a.m., 1300 early level; move sampler by stove vent, level to 5000 (= outdoor); turn on stove burner (electric ring). (2) Note variation up to max 500000 when sampler moved up and down to breathing zone level before exhaust fan turned on. (3) Level to 6000 2000 on counter top; 7:47 a.m., counter top 22 000. (4) 7:55 a.m., out of kitchen to hallway to upstairs, 1700; back to kitchen, 25000 by counter top. (5) Up to 35000 and more above stove with exhaust fan on; 8:09 a.m., turned off exhaust fan, meter at breathing level up to 500000+. (6) Levels on counter 100000+, exhaust fan on, fumes spread; levels by exhaust fan <100000. (7) To counter top, 8:12 a.m., 30000; 8:20 a.m., counter; back to stove, vent off; hallway, living room, kitchen, 18000. (8) Outside 8:28 a.m.; into car 8:30 a.m.; 3400 inside car, then up to 5000 as equilibrates with outside air. home increased as doors were opened and were generally related to influx of outdoor air, where baselines of from 2000 to >10000 particles/cm 3 were observed. Cooking activities such as toasting caused concentrations to exceed the maximum detectable (500000 particles/cm 3 ); the results clearly demonstrate dispersion of the particles throughout the home (having forced air continuous ventilation) and the time course of clearance (Figs 2 and 3). Re-entrainment of UFPM from the exhaust of a well-ventilated ceramics kiln (electric) was detected and corrected (Fig. 4a). In addition, polycarbonate filter samples from the kiln exhaust were examined by scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS) (Fig. 4b), which revealed few ultrafine particles within the resolution limits of the SEM (>100 nm). However, aggregates of UFPM consistent with origin from the ceramics and glaze materials were identified, as well as fine sulfates, as seen in the ambient air. In a mobile environment inside a passenger vehicle (usually with the windows closed), there was rapid penetration of UFPM from outdoors and passing diesel vehicles (school buses and trucks) resulted in a rise from baseline up to >500000 particles/cm 3 (Fig. 5a and b). Note a sharp peak at the end of the sampling shown in Fig. 5b, as the P-Trak was carried past a small area set aside for smokers, near the entrance to the building. A summary of UFPM data from the first 67 sample collections (indoors and outdoors) is presented in Fig. 6a and b. In addition to the average data (Fig. 6a), an index of cumulative exposure is presented, calculated by multiplying the average UFPM number concentration by the duration (min) of each sample (Fig. 6b). Nearly continuous sampling (except for the time required to change batteries and recharge the alcohol chamber) during two round trips from Syracuse to New York and back using the same route ( 900 km round trip) revealed large variations in UFPM counts, mostly associated with diesel truck traffic immediately ahead of the passenger car and with generally heavy stop-and-go urban traffic (see Fig. 7a c). The average particle concentration over the 12 13 h for the second trip (not shown) was remarkably similar to that for the first trip (Table 1). Prolonged exposures to concentrations >100000 particles/cm 3 commonly occur in traffic behind or near diesel vehicles and persistent levels on highways increase with general traffic volume. Acute upper respiratory symptoms (headache, nasal/sinus congestion and rhinitis) were noted by both driver and passenger in the car at very high exposure levels (>150000 particles/cm 3 ). The sensory recognition of these symptoms occurred within <1 min of the sharp increases associated with diesel traffic.

408 J. L. Abraham, G. Siwinski and A. Hunt Table 1. Summary UFPM data from three segments of a round trip from Syracuse to New York and back Trip A B C Sampling duration Hours 3:42 2:59 6:52 Minutes 222 179 412 Start time 7:39 11:22 14:40 Stop time 11:22 14:21 21:32 Average particles/cm 3 28145 31779 29891 Cumulative particles/cm 3 min 6248190 5688441 12315092 Maximum particles/cm 3 158000 128600 190200 Min particles/cm 3 23870 4320 6204 Fig. 4. (a) Re-entrainment of UFPM from kiln exhaust. (b) Examples of particles in kiln exhaust; 30 min sample. Aluminum silicate aggregate, sulfates (ambient) and zirconium silicate. DISCUSSION There is scant data on particle numbers in indoor environments. Abraham (1998a) reported direct SEM counting of fine PM on membrane filters from indoor environments and the effects of use of a HEPA filter system. He counted particles limited by the resolution of SEM to >100 nm and sampled over 24 48 h. Our tests of UFPMs used the same rooms and HEPA system as he did, but counted particles >20 nm with the TSI P-Trak system, sampled at 1 s intervals. Most ( 80%) of the particles counted in his SEM study were carbonaceous, with sulfates the next most prevalent particle ( 17%). Abraham demonstrated a signifi-

Filtration and particle number concentration 409 cant 62% reduction (from 85.5 to 32.5 particles/cm 3 ) with use of the HEPA filter system. Our studies of UFPMs, with a much finer time resolution than is possible with SEM sampling by membrane filters, confirmed the reduction in particle concentration with HEPA filtration, operating in the same rooms studied by Abraham. Furthermore, by instantaneous monitoring of sources of air from ventilation ductwork and from the outflow of the HEPA filter unit (0 particles/cm 3 ) it was clear that in a real world situation the measured PM concentration was an equilibrium between incoming air and filtration activity. In a second study Abraham (1998b) used membrane filter sampling and SEM/EDS analysis to count and analyze sub-micrometer PM indoors and outdoors and with personal sampling. Particles >100 nm were analyzed. Total PM concentrations ranged up to 500/cm 3 and indoor concentrations clearly paralleled those outdoors. Our results with UFPMs, as expected, show higher number concentrations than the SEM filter counting methodology. Similar trends for indoor/outdoor particle concentrations are shown. Other than indoor combustion sources, the major determinant of indoor UFP concentration is clearly the infiltration of outdoor air. Abraham (1998b) also demonstrated compositional differences between indoor and outdoor sulfate fine particles, with more sulfur-only (most likely ammonium sulfates) or sodium sulfate particles outdoors and more potassium-rich sulfates indoors. Based on our observations on the high concentrations of UFPMs generated by indoor combustion sources, it Fig. 5. (a) Sampling UFPM in a mobile environment. (1) Following 50 ft behind school bus; (2) bus coasting down hill; (3) accelerating up hill; (4) pass bus; (5) at school parking lot; (6) as same bus approaches school parking lot; (7) into village; (8) onto street with light traffic; (9) onto I-481 south (light traffic); (10) onto I-81 north (no trucks in sight); (11) downtown exit (smell of diesel exhaust on Adams St.); (12) in laboratory at university. (b) Morning commute and environmental tobacco smoke. Fig. 6. (a) Average ultrafine particle concentration in 67 tests (>128 h). (b) Cumulative ultrafine particle exposures in 67 tests.

410 J. L. Abraham, G. Siwinski and A. Hunt Fig. 7. (a) Long distance UFPM exposure inside car: 13 h+ round trip, Syracuse to New York and back. (b) Syracuse to New York: UFPM exposure inside car. Note the prolonged very high UFPM levels related to variable traffic conditions in the city and on the highway. Longer time averaging does not reveal these. (c) UFPM inside car in the vicinity of New York. appears likely that the source of the K-rich sulfates is from combustion of K-rich materials such as foods, candles, etc. Whether K-containing UFPMs aggregate with sulfates from outdoor sources or are generated as a single entity remains to be determined. Dennekamp et al. (2001) measured UFPM and NO x in simulated kitchens, using a TSI 3934 scanning mobility particle sizer and a 3022A condensation particle counter. Their measurements were more detailed than those we report and limited to a single non-mobile controlled laboratory room, but comparisons on reported UFPM number concentrations are worth noting. The time resolution of their measurements was 2.5 min, with averaging over 5 min, whereas ours was 1 s. They compared gas versus electric ring cookers, a grill and an oven in a 70 m 3 room with the windows closed and no mechanical ventilation. Our measurements were in a real home environment with a forced air ventilation system and exhaust ventilation in operation at times. Their table 2 presents the maximum 5 min concentrations above background (their number concentrations are presented for the size range 10 500 nm, our results are not size resolved but are for UFPM >20 nm). As we tested only electric rings, only those results will be compared. They observed peak concentrations (averages, UFPM/cm 3 ) of: one ring, 94000; four rings, 111000 (no increase when pan heated to boil water); grill only, 77000; toast, 134000. Our results show much higher short-term peaks (>500000 UFPM/cm 3 ) for similar cooking activities. Observed decay rates for UFPMs in the closed unventilated laboratory was 30 min for a 50% loss. Coagulation of the particles was the most likely reason. Dennekamp et al. have discussed the importance of outside concentrations and of measuring and modeling individual (personal) exposures. Our studies provide a measurement methodology and some data enabling direct measures of personal exposures to UFPMs. In our real world ventilated room ( 5 5 3 m) the time for a 50% loss of UFPM from a point source (lighted match) was 20 30 min. Wallace (2000) measured PM in an occupied town house and Abt et al. (2000) characterized indoor particle sources: both found toasting (among other activities) contributed to indoor PM. Neither of these studies however measured UFPMs. Dennekamp et al. (2001) stated: Although no experimental studies of human exposure to indoor UFPs have been undertaken, the concentrations found indoors are as high as those found outdoors during episodes of high air pollution, when people have been shown to demonstrate health effects (Peters et al., 1997). Both our studies and those of Dennekamp et al. (2002) present initial data expanding the available database of information on UFPM exposures. This type of sensitive and portable instrumentation should be highly useful in studies of UFPM in mobile and personal micro-environments. Acknowledgements This work was supported by the SUNY Upstate Medical University Foundation and by the Department of Pathology. REFERENCES Abraham ME. (1998a) Microanalysis of indoor aerosols and the impact of a compact HEPA filter system. Indoor Air; 9: 33 40. Abraham ME. (1998b) Physico-chemical characterization of submicrometer indoor/outdoor aerosols. In PM 2.5 : a fine particle standard, Vol. 2. pp. 862 75. Abt E, Suh HH, Allen G, Koutrakis P. (2000) Characterization of indoor particle sources: a study conducted in the metropolitan Boston area. Environ Health Perspect; 108: 35 44.

Filtration and particle number concentration 411 Dennekamp M, Howarth S, Dick CA, Cherrie JW, Donaldson K, Seaton A. (2001) Ultrafine particles and nitrogen oxides generated by gas and electric cooking. Occup Environ Med; 58: 511 6. Dennekamp M, Mehenni OH, Cherrie JW, Seaton A. (2002) Exposure to ultrafine particles and PM 2.5 in different microenvironments. Ann Occup Hyg; 46 (suppl. 1): 412 4. Peters A, Wichmann HE, Tuch T, Heinrich J, Heyder J. (1997) Respiratory effects are associated with the number of ultrafine particles. Am J Respir Crit Care Med; 155: 1376 83. Wallace L. (2000) Real-time monitoring of particles, PAH, and CO in an occupied townhouse. Appl Occup Environ Hyg; 15: 39 47.