SIERRA MODEL 12 X 24 SPECIFICATIONS

Similar documents
DUGOUT MODEL (4 POST) 10 x 24 SPECIFICATIONS

COOK HOUSE SHELTER TENDER BID SHEET

STRUCTURAL STEEL FRAMING

Product Guide Specification DIVISION SPECIALTIES MANUFACTURERS OF PROTECTIVE COVERS

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

Specifications for FL-100 Soffit Panel

603 Summit Avenue, Suite 102 Greensboro, N.C Voice/FAX (336)

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

SECTION STRUCTURAL STEEL

SECTION PRE-ENGINEERED EXTRUDED ALUMINUM DECKING WALKWAY COVERS SPECIFICATION

SPECIFICATIONS Section Gable Walkway Covers

Architectural Roof & Wall Products Guide Specifications MANUFACTURER KLOECKNER METALS KALAELOA BLVD, KAPOLEI, HI 96707,

SECTION STRUCTURAL METAL FRAMING

SECTION COMPOSITE METAL DECKING

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

SECTION COMPOSITE METAL DECKING

PRE-ENGINEERED METAL BUILDING SYSTEM

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

A. Drawings and general provisions of the Contract, including General Conditions Specification Sections, apply to this section.

TECHNICAL SPECIFICATIONS 2019

COLQUITT COUNTY BOARD OF COMMISSIONERS 101 East Central Avenue

SPECIFICATIONS Section Cantilevered Walkway Cover

SECTION AWNINGS

02800 SHADE STRUCTURES

STANDARD SPECIFICATION FOR ALUMINUM FRAMING FOR RAILROAD PASSENGER SHELTERS

CS-100 Guide Specifications

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION METAL ROOF AND SOFFIT PANELS

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

SECTION PREFABRICATED PIPE BRIDGE(s)

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION PRE-ENGINEERED METAL BUILDING

ARCHITECTURAL SPECIFICATION

SECTION METAL ATHLETIC LOCKERS

SECTION METAL ATHLETIC LOCKERS

SECTION STEEL DECKING

SECTION METAL EQUIPMENT LOCKERS

SECTION METAL DECKING. A. Extent of metal decking is indicated on Plans, including basic layout for the following type of deck required:

DL-200. Specifications

DIVISION 5 METALS SECTION STRUCTURAL STEEL

SECTION STRUCTURAL STEEL

SSL-175. Specifications

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

SECTION DECORATIVE METAL FENCES AND GATES

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

NRM-7000 Guide Specifications

SECTION DSA PRE-ENGINEERED FABRIC SHADE STRUCTURES

1.02 SYSTEM DESCRIPTION

UC Denver Guidelines and Design Standards SECTION STRUCTURAL METAL FRAMING

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

Architectural Roof and Wall Products Guide Specifications


SECTION METAL BUILDING SYSTEMS

SECTION PRE - ENGINEERED METAL BUILDING MATERIALS

Architectural Roof and Wall Products Guide Specifications

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

PROJECT: 4/30/14 DATE: REVISIONS: 6/10/14 7/28/14 11/3/14 11/12/14 11/14/14 OF 6

Architectural Roof Products Guide Specifications

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

1. High bay shelving units, fabrication and installation including leveling.

Architectural Roof Products Guide Specifications

SECTION PRE-ENGINEERED MEMBRANE STRUCTURE

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

Guide Specification SDP 200

SECTION 2 DIVISION 05 METALS

SECTION EXTERIOR SUN SHADES

SECTION MISCELLANEOUS METALS THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION MISCELLANEOUS AND ORNAMENTAL IRON

SECTION ORNAMENTAL WELDED STEEL FENCING

238T Aluminum Standing Seam Metal Roof System (SSMRS)

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

2. Clarification: The notice to proceed construction period of 60 days will begin after the Contractor receives all materials and equipment.

Division MEDICAL EQUIPMENT SUPPORT SYSTEMS PART 1 GENERAL

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

Dugout Covers Specifications

SECTION CANOPIES. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

D I V I S I O N 05: M E T A L S

SECTION PRE-ENGINEERED METAL BUILDING SYSTEM (FOR OFFICE AREA)

SECTION STAINLESS STEEL WALL PANELS

ARCHED METAL FRAMED SKYLIGHTS EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING

SECTION METAL BUILDING SYSTEMS

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

1.02 SYSTEM DESCRIPTION

WARDLAW AHU-2 REPLACEMENT

SECTION CLIMBING WALLS

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION DECORATIVE METAL RAILINGS

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

SECTION 716 SIGN MATERIALS SCOPE

SECTION MISCELLANEOUS METALS

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

WATERTOWN REGIONAL AIRPORT T-HANGAR SPECIFICATIONS 8 UNIT MODEL LK42

SECTION ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS

FUM10-4-DB_8EV-E1 Y638 PROJECT NAME: HARRIS PARK Y638 PROJECT LOCATION: LEAWOOD, KS DRAWING NOTES DESIGN CRITERIA: SEE CALCS DRAWING LIST

Transcription:

SIERRA MODEL 12 X 24 SPECIFICATIONS Dimensions: Roof Dimensions 12-0 x 24-0 Column Dimensions (center to center) 9-0 x 21-0 Minimum Clearance 8-0 Shed Roof 1:12 pitch Square Feet Under Roof 288 Columns shall be 6 x 6 steel tube, minimum.120 wall thickness. All beams shall be structural steel tube sized according to engineering. All bolts shall be A-325 or A-307 and hidden at all connections. Roofing shall be 24 gauge HR-36 steel pre-cut and pre-finished with ribs running with the slope of the roof. Trim shall be 24 gauge pre-finished to match roofing. Open or welded C channel, I beams, S or Z purlins or angle iron shall not be allowed. 11875 E. Berry Dr., Dewey, AZ 86327 Ph: (928) 775-3307 Fax: (928) 772-0858 info@classicrecreation.com www.classicrecreation.com

STANDARD SPECIFICATIONS w/ PRIME PAINTED FRAME GENERAL: 1. All structures shall be designed and fabricated to the UBC or IBC (Latest Edition) with standard load designs of 20# per S.F. minimum live load, 90 mph wind load and the applicable zone for seismic loads. 2. All members shall be designed according to the American Institute of Steel Construction (AISC) specifications and the American Iron and Steel Institute (AISI) specifications for cold-formed members. 3. All fabrication welds shall be in strict accordance with the structural welding code of the American Welding Society (AWS) specifications. All structural welds shall be in compliance with the requirements of Pre-qualified welded joints. All welding shall conform to ASTM A-233 series E-70XX electrodes - low hydrogen. Field welding shall not be required. 4. The shade structure manufacturer shall submit structural calculations after award of bid, sealed by a registered engineer in the state in which the structure is to be erected for review and approval by the approving agency. 5. Manufacturer qualifications: The manufacturer (or company) shall have been in continuous operation as a single source business a minimum of 5 years, specializing in the fabrication of tubular steel shade structures, bus stops and kiosks. Shade structures, bus stops & kiosk fabrication shall be the manufacturer s primary business. The manufacturing company shall have fabricated similar structures to that which is specified. Job shop companies do not qualify as a single source business. Individual experience with other similar companies does not apply. Manufacturer shall be a City of Los Angeles Approved Fabricator in good standing. 6. Submittals: All non-specified manufacturers shall submit complete shop drawings indicating type, size & gauge of material used, with detailed connections to the specifying agency or design firm at least 10 days prior to bid opening for review and written preapproval. All bids submitted without prior approval will be rejected. FOOTINGS & COLUMNS: 1. Footings shall be structurally engineered by the structure manufacturer to meet local codes and site conditions. (Sample footing drawings shall be made available to the contractor or owner from the manufacturer). Anchor bolts for surface mounted structures shall be supplied by the owner / contractor. Columns shall be ASTM 500 grade B. Concrete footing rebar (if required) shall be ASTM A-615 grade 40 #4 bars & smaller, grade 60 #5 bars & larger. Concrete shall be 5 sack mix Portland cement. Maximum slump shall not exceed 4. Compressive strength: 2500 psi @ 28 days.

FRAME MEMBERS: 1. All frame members shall be one piece structural steel tube with a minimum.120 (1/8 ) wall thickness, sized according to engineering. All frame members shall be bolted together with bolts totally concealed. Compression rings shall be fabricated from structural steel tube or flat plate steel and shall have all connections concealed from view. All tubing for frame members shall be ASTM 500 grade B. Beam end plates shall be ASTM A36 fy=36,000 psi UNO. All steel members are manufactured from over 95% recycled material. Bolts shall be A 325 s unless noted otherwise. I beams, Angle iron, C, Z or S purlins or beams, open or closed, shall not be allowed. ROOFING: 1. All roofing shall be AEP Span, Inc. 24 gauge Zincalume / Galvalume coated steel panels. HR-36 panels, (ICBO #ER-2757), shall be 36 wide with 1½ high ribs @ 7.2 o.c. All roofing shall be pre-finished with PVF2 (Polyvinylidene Fluoride) Kynar 500. All roof panels shall be pre-cut with ribs running with the slope of the roof. Roof shall be manufactured from over 98% recycled material. Fascia trim shall be 1½ J channel, 24 gauge Zincalume / Galvalume coated and pre-finished to match the roof color. Screws & rivets shall match roof color. No exceptions will be allowed. PAINT: 1. All frame members shall be factory prime painted with Sherwin Williams Kem 400 quick drying primer. Gloss: 60-80 units. Volume solids: 25± 2%. Viscosity: 35-45 seconds #3 Zahn Cup & 60-75 seconds #4 Ford Cup. Recommended film thickness: Mils Wet 4.5-5.5, Mils Dry 1.0-1.25. Spreading Rate @ 1 mil dft: 400 s.f. / gal. Two coats of a high quality, industrial grade, gloss enamel finish coat, compatible with Sherwin Williams Kem 400 primer, shall be furnished and applied in the field with a professional spray gun by the contractor or installer after the frame is erected. ERECTION: 1. Manufacturer shall supply complete layout and detail plans with installation instructions or the structure. The structure shall be erected in a work-man-like manner with framing, roofing and trim installed according to the manufacturer s installation instructions. Care shall be taken to avoid damaging the structure during installation. WARRANTY: 1. Manufacturer shall warranty the structure to be free from defects in material and workman-ship for a period of (5) five years from date of acceptance by owner. Warranty does not include damage from theft, fire, vandalism or acts of God. Manufacturer shall repair or replace structure components of like kind at his option, to match existing material and workmanship. NOTE: Engineering specifications take precedence over drawings if differences occur.