WIREMOLD Furniture Feed Style Poke-Thru Devices

Similar documents
F E A T U R E S & B E N E F I T S

WIREMOLD Pedestal Style Poke-Thru Devices

Pedestal Style Poke-Thru Devices from Wiremold/ Legrand

The RFB11 and RFB9 Series Floor

RC9 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R3 Updated April 2005

RC4 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R2 Updated April 2005

RC7 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R2 Updated April 2005

Evolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

WALKER FLOOR BOXES STILL LOOKING AT FLOOR BOXES IN THE SAME OLD WAY?

Evolution Series. 6" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

FLOOR FLOOR AND ANY VISION. FOR ANY WIREMOLD FLOOR BOXES. designed to be better.

FLOOR AND ANY VISION. FOR ANY FLOOR. designed to be better.

WIREMOLD Flush Style Poke-Thru Devices

Abuilding s Wire Management System may be able to

WIREMOLD Evolution Series Floor Boxes

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

Floor Box Assembly. Features. Dimensions and Weight. Descriptions. Catalog Number

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

FPBTCBK D/C Al FLGD CVR. Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information

Flush Service Floor Boxes

Introducing the next generation in innovative surface raceway systems. The new 4000 Designer Series Aluminum

WIREMOLD Trenchduct Feeder Systems

FPT4 SERIES POKE-THROUGHS INSTALLATION INSTRUCTIONS

Raceway Solutions TM. Conventional Underfloor Duct. Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System

Plastic Floor Box. Wiring Device-Kellems

For large capacity, easy installation and

IMPORTANT - PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING. SAVE THESE INSTRUCTIONS FOR REFERENCE AND ADDITIONAL WORK REQUIRED AFTER CONCRETE POUR.

ROBERTSON "3 + 1" SLAB-ON-GRADE SINGLE LEVEL RACEWAY SYSTEM (Revised July 2000)

Youngstown State University

MONO-SYSTEMS, INC. UNIQUE CABLE DISTRIBUTION SOLUTIONS

FloorBoxes. f r o m T h o m a s & B e t t s

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0528 Pathways. Page 1 of 6

SECTION INTERIOR COMMUNICATION PATHWAYS

AMTC412 Wiremold Amtc-412 TPP Blank Alum. Features Made in USA. Material, Color, and Finish. Dimensions and Weight.

SECTION OUTLET, PULL, AND JUNCTION BOXES

8461C 4SQ, 1"RSD Rndopnw/Ers CVR

QTY 7/374 8/346 11/375 12/348 17/298 18/324 19/ / /472 24/473 3 QTY

(3) 1/2 INCH CONDUIT BOTTOM, (2) 3/4 INCH CONDUIT BOTTOM, (8) 1 INCH CONDUIT SIDES Box

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

TW Series THRU-WALL BARRIER Cable/Conduit Sealing Device

SECTION CONDUIT AND BOXES

Also available in Premium Finishes See submittal SUB for Premium Finishes

Product Specifications MRI Trench Duct

PRODUCT GUIDE. Connectivity with flexibility.

Electrical Metallic Tubing (EMT) Fittings

LIVE WORK PLAY LOBBY TO ROOFTOP SOLUTIONS FOR MIXED-USE BUILDINGS. designed to be better.

Student Services & Classroom Addition

Big 52 cubic inch capacity. S3-52-W 3 Gang Old Work Box shown with Divider Plate, LVDIV-1

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Steel Square Box, Height 4 Inch; Width 4 Inch; Depth 1-1/2 Inch; Capacity 21 Cu Inch; 17 Knockout(S); Knockout Location (5) Bottom, (12) Side

Wall studs. Wall Studs

Kaf-Tech Product Specification

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

DISCONTINUED CFL. Specifications. Compact Floodlights revision 11/13/14 kl_cfl_spec.pdf. Fixture Options: Approvals: Job: Fixture Catalog number:

Electrical Metallic Tubing (EMT) Fittings

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

1. Hangers and supports for electrical equipment and systems.

Raceway and Boxes for Electrical Systems Page 1 of 7

Trench Duct Class Catalog 5230CT9601R10/08

CONTENTS. B. System Design and Performance Requirements

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

SECTION PATIENT BED SERVICE WALLS

MESH FLOOR HEATING SYSTEMS INSTALLATION INSTRUCTIONS

2. Fittings shall be threaded and finished similar to conduit. Threadless fittings shall not be used.

PROJ. NO SECTION WIRING DEVICES

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS. A. ANSI C Electrical Rigid Steel Conduit, Zinc Coated.

CUSTOM PRODUCTS & SERVICES, INC. PH: FAX: WEBSITE:

Tate Access Floors, Inc. WC5000 Air Seal Access Floor Panel Cornerlock Understructure

ELECTRICAL SECTION 2

SECTION LIGHTING. A. Section Basic Electrical Materials and Methods

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

American Metal Specialties, Inc.

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved

ON-FLOOR WIREWAY INSTALLATION GUIDE

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Red Dot. Rigid Fittings. Table of Contents

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

fischer Test Report Fixing Tests for Bison Hollow Core Slabs

PRE-INSTALLATION GUIDE

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

Tate Access Floors, Inc. All Steel 1000 Access Floor Panel 600 mm Bolted Stringer Understructure System

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).

CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING

SECTION ELECTRICAL SYSTEM RACEWAY and BOXES

FLOOR AND AREA DRAINS

`bfifkd=c^k=prmmloq=molar`qp

H-Body Sealants Guide

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Industrial Thermocouples

Transcription:

WIREMOLD Furniture Feed Style Poke-Thru Devices Bring Power & Communication Services to Modular Furniture Systems Protection from water, dirt, and debris. Furniture Feed Style Poke-Thru Devices are an excellent solution for feeding power and communication services to modular furniture systems in an open space, above grade floor environment. Every Wiremold Poke-Thru Device comes with built-in TopGuard protection, an industry-leading design that meets and exceeds UL scrub water exclusion requirements for tile and carpet floors. TopGuard protection prevents water, dirt, or debris from entering the power and communication compartments through the service head or floor fittings. All Wiremold Furniture Feed Style Poke- Thru Devices can be installed on tile, carpet, or wood covered floors and are an excellent solution for both new or retrofit construction. Typical applications include commercial office buildings, financial institutions, and government facilities. RC7AFFTC Series 4FFATC Series RC9AFFTC Series RC9AM2TC Series FEATURES & BENEFITS n 4FFATC Flush Style Furniture Feed Series provides one 3/4" opening for power and one 1 1/4" opening for communication cabling. Provides largest dual service capacity for furniture feed applications in the industry. UL Listed for both power and communication furniture feed applications. n RC9AM2 Flush Style Furniture Feed Series provides a combination 1 1/4" and 2" trade size conduit opening in cover. UL Listed for both power and communication furniture feed applications. n RC9AM2 Flush Style Furniture Feed Series accepts up to 36 UTP cables. Reduces overall project costs by eliminating the need for additional poke-thru devices in high capacity, modular furniture applications. n RC9AFFTC Series provides hexagonal housing with six openings for power. Permits communication and power cables to be conduit-protected when passed through the unit. n RC7AFFTC Flush Style Furniture Feed Series provides one 3/4" and two 1/2" trade size conduit openings in cover. Eliminates the cost of a second poke-thru device to accommodate power and communication services. n Step-on-it installation. Quick and easy installation without the need for additional fasteners or the need for a second installer. n Fire rated for up to 2-hour rated floors. Maintains the fire classification of the floor. n Communication connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point-of-use. n TopGuard Protection. Integral design component that prevents water, dirt and debris from entering power and communication compartments. Whenever you see the TopGuard protection icon on any Wiremold product, you ll know it meets and exceeds UL scrub water exclusion requirements for tile and carpet floors. n Suitable for use in air handling plenums in accordance with Sec. 300-22 (C) of the National Electrical Code. n UL Listed and UL Fire Classified to U.S. and Canadian safety standards for tile and terrazzo. Includes the new UL requirements under UL514A and UL 514C for the scrub water exclusion test for carpet and wood covered floors. ED1216R8 Updated January 2016 For latest specs visit www.legrand.us/wiremold

Furniture Feed Style Poke-Thru Device Specifications 3" Diameter Hole POKE-THRU SERIES RC7AFFTC Series RC7AM2TC Series RC9FFTC Series RC9AM2TC Series HOLE SIZE Minimum: 3 1/16 " (78mm) Maximum: 3 1/8" (79mm) Minimum: 3 " (76mm) Maximum: 3 1/8" (79mm) Minimum: 3 " (76mm) Maximum: 3 1/8" (79mm) Minimum: 3 " (76mm) Maximum: 3 1/8" (79mm) UL FIRE CLASSIFICATION UL SCRUBWATER PROTECTION CAPACITY MAXIMUM COPPER FILL POWER* COMMUNICATIONS* TopGuard TopGuard TopGuard 2 Gangs Two (2) 1/2" & one (1) 3/4" trade size Screw Plug Openings (10) #12 AWG (7) Cat 6A/Channel.004 Sq. in. (2.58 sq. mm) 2 Gangs Two (2) 1/2" & one (1) 3/4" trade size Screw Plug Openings (20) #12 AWG (32) Cat 6A/Channel.004 Sq. in. (2.58 sq. mm) 2 Gangs Hexagonal Service Head with one (1) 1/2" trade size Conduit & five (5) Comm Openings (11) #12 AWG (20) Cat 6A/Channel.01600 Sq. in. (10.324 sq. mm) TopGuard 2 Gangs One (1) 1 1/4" Concentric Screw Plug (20) #12 AWG (32) Cat 6A/Channel.01600 Sq. in. (10.324 sq. mm) COVER SIZE COVER COLORS COVER CONSTRUCTION Die-Cast Die-Cast Die-Cast Die-Cast CONDUIT/STEM DIAMETER FLOOR COVERING THICKNESS One (1) 3/4" & two (2) 1/2" trade size Conduit One (1) 2" trade size Conduit One (1) 3/4" & two (2) 1/2" trade size One (1) 2" trade size Conduit 4" Diameter Hole POKE-THRU SERIES HOLE SIZE UL FIRE CLASSIFICATION 4FFATC Series Minimum: 4" (102mm) Maximum: 4 1/8" (105mm) * The above maximum copper fill values are the maximum amount of copper to maintain fire classification and are for each individual power and communication compartments. Do not add values together for any one compartment. UL SCRUBWATER PROTECTION CAPACITY MAXIMUM COPPER FILL POWER* COMMUNICATIONS* TopGuard 2 Gangs One (1) 3/4" & one (1) 1 1/4" trade size Screw Plug Openings (16) #12 AWG or (10) #10 AWG (22) Cat 6A/Channel.004 Sq. in. (2.58 sq. mm) COVER SIZE COVER COLORS COVER CONSTRUCTION 7 1/2" (191mm) Die-Cast CONDUIT/STEM DIAMETER FLOOR COVERING THICKNESS One (1) 3/4" & one (1) 1 1/4" trade size Conduit Download this product s PEP ecopasport environmental product declaration at www.legrand.us/resources-and-downloads. This declaration conforms with ISO 14025 and 14040 and is in alignment with EN 15804. 2

Furniture Feed Style Poke-Thru Device Specifications Copper Cross Section: The copper cross-sectional area determines the amount of wire fill capacity in a poke-thru device. Unlike other wire and cable management systems that utilize wire fill capacity, a poke-thru device is UL tested under fire conditions to determine the maximum amount of copper conductors that will pass through a poke-thru device, while maintaining the fire-rating of the concrete slab. All Walker Flush Style Devices are UL Classified to U.S. and Canadian safety standards (see complete marking on product) to accommodate at a maximum rating as follows: 4FFATC SERIES Maximum Allowable Copper Cross-Sectional Area: 4FFATC Power Compartment Only =.08192 sq. in. (52.851 mm 2 ) 4FFATC Communication Compartment Only =.072 sq.in. (46.452 mm 2 ) NOTE: The 4FFATC Series requires a 4" (102mm) cored hole. (American made core bit having an outside diameter of 4 1/16" (103mm)) RC7AFFTC SERIES Maximum Allowable Copper Cross-Sectional Area: RC7AFFTC Power Compartment Only =.05214 sq. in. (33.64mm 2 ) RC7AFFTC Each Communication Compartment Only =.05000 sq. in. (32.26mm 2 ) NOTE: The RC7AFFTC Series requires a 3" (76mm) cored hole. (American made core bit having an outside diameter of 3 1/16" (78mm).) RC9AFFTC SERIES Maximum Allowable Copper Cross-Sectional Area: RC9AFFTC Power Compartment Only =.05726 sq. in. (36.94mm 2 ) RC9AFFTC Each Communication Compartment Only =.06425 sq. in. (41.45mm 2 ) NOTE: The RC9AFFTC Series requires a 3" (76mm) cored hole. (American made core bit having an outside diameter of 3 1/16" (78mm).) RC9AM2TC SERIES Maximum Allowable Copper Cross-Sectional Area: RC9AM2TC when power cables are used =.09216 sq. in. (59.46mm 2 ) RC9AM2TC when communication cables are used =.09216 sq. in. (59.46mm 2 ) NOTE: The RC9AM2TC Series requires a 3" (76mm) cored hole. (American made core bit having an outside diameter of 3 1/16" (78mm).) Copper Cross Sectional Area of Commonly Used Conductors Size Solid #24.00032 sq. in. (.206mm 2 ) #22.00050 sq. in. (.322mm 2 ) #14.00323 sq. in. (2.083mm 2 ) #12.00512 sq. in. (3.303mm 2 ) #10.00815 sq. in. (5.258mm 2 ) #8.01296 sq. in. (8.361mm 2 ) NOTE: Use above values for solid or stranded conductors. IMPORTANT! The above maximum copper cross sectional area values are for each individual power and communication compartment. DO NOT add values together for any one compartment. Floor Coverings: The poke-thru device is fire rated for carpet and wood covered floors, tile floor coverings up to 3/4" (19.1mm) maximum thickness, and linoleum floor coverings up to a maximum of 1/8" (3.2mm) thickness. For other floor coverings not listed above, consult factory. CAUTION: These devices meet all UL scrub water requirements, but are not suitable for wet or damp locations, or other areas subject to saturation with water or other liquids such as commercial kitchens. CAUTION! Core bits vary in size from manufacturer to manufacturer: Use a 3" (76mm) American made core bit having an outside diameter of 3 1/16" (78mm). Minimum hole diameter 3 1/16" (78mm). Use a 4" (102mm) American made core bit having an outside diameter of 4 1/16" (103mm). Minimum hole diameter 4 1/16" (103mm). Concrete Thickness Min/Max: 1-HOUR RATED FLOOR 2 1/4" (57mm) min over top of deck (or 3" (76mm) thick reinforced concrete slab) to a maximum of 7 1/2" (191mm). 2-HOUR RATED FLOOR 3 1/4" (83mm) min over top of deck (or 4" (102mm) thick reinforced concrete slab) to a maximum of 7 1/2" (191mm). 3

4" HOLE SIZE POKE-THRU DEVICES F AV3STC 4FFATC Poke-Thru Series Ordering Information Insert Stem with Disposable Plate Use with 4FFCTC Series covers to form a complete 4FFCTCGY Finish Flange and Conduit 4FFCTCBK Adapter Assembly Complete 4FFCTCAL with one 3/4" and one 1 1/4" 4FFCTCBS trade size conduit adapters and closure plugs. Colors available in painted black (BK), gray (GY), forged brush aluminum (AL), and brass (BS). Use with the AV3STC Insert to form a complete 7 1/2" (191mm) Catalog Number Explanation 4FFATCAL 4 FF A TC AL Indicates Unit is Designates Unit Assembled Unit Identifies that Indicates Finish only for use in a is for Furniture (A) or Cover (C) Unit is Approved 4" core hole Feed Application for Tile and Carpet Floors 4FFATCGY Flush Furniture Feed 4FFATCBK Poke-Thru Assembly 4FFATCAL Complete with one-piece finish 4FFATCBS flange and conduit assembly. Conduit assembly consists of one 3/4" trade size conduit and one 1 1/4" trade size conduit. Finish cover flange provided with one 3/4" trade size screw plug opening and one 1 1/4" trade size screw plug opening. Colors available in painted gray (GY), painted black 7 1/2" (BK), brushed aluminum (AL), and (191mm) brass (BS). 16 15/16" (430mm) NOTE: Assembled with scrub water gasket. For use on ABPLUG4 Abandonment Plug Assembly 7 1/2" Complete plug assembly for (191mm) abandoning an open 4" (102mm) cored-hole. Assembly includes intumescent fire-stop material to maintain the fire-classification of the floor, integral retainer ring to prevent the unit from pulling up 3 7/8" through the floor, and a black (98mm) die-cast aluminum cover. Hole Size Chart Hole Size Hole Size Minimum Maximum 4FFATC 4" (102mm) 4 1/8" (105mm) AV3STC 4" (102mm) 4 1/8" (105mm) ABPLUG4 4" (102mm) 4 1/8" (105mm) 4FFCTC 4" (102mm) 4 1/8" (105mm) NOTE: Assembled with scrub water gasket. For use on NOTE: To abandon 4FFATC Series, disconnect conduit adapters and install closure plugs. NOTE: See page 6 for specifications. 4

3 1/16" HOLE SIZE POKE-THRU DEVICES F RC7STC Insert Stem with Disposable Plate Use with RC7CFF Series covers to form a complete 16 1/2" (419mm) RC7AFFTC Poke-Thru Series Ordering Information RC7CFFTCGY Finish Flange and Conduit RC7CFFTCBK Adapter Assembly Complete RC7CFFTCAL with one 3/4" and two 1/2" RC7CFFTCBS trade size conduit adapters and closure plugs. Colors available in painted black (BK), gray (GY), forged brushed aluminum (AL), and brass (BS). Use with the RC7STC Insert to form a complete Catalog Number Explanation RC7AFFTCAL RC7 A FF TC AL Identifies Identifies Designates Unit Identifies Identifies Poke-Thru Assembled Is for that Unit is Color of Series Unit (A) or Furniture Approved for Finish Cover (C) Feed Applications Tile and Flange Carpet Floors RC7AFFTCGY Flush Furniture Feed RC7AFFTCBK Poke-Thru Assembly RC7AFFTCAL Complete with one-piece finish RC7AFFTCBS flange and conduit assembly with one 3/4" and two 1/2" trade size conduit adapters and closure plugs. Colors available in painted aluminum, black (BK), gray (GY), forged brush aluminum (AL), and brass (BS). 16 1/2" (419mm) NOTE: Not designed to work with bare concrete NOTE: Assembled with scrub water gasket. For use on or terrazzo floors. NOTE: Minimum floor covering thickness 1/8" (3.2mm). COM50 Communication Adapter COM75 For two 1/2" trade size conduit connections (COM50). For two 3/4" trade size conduit connections (COM75). NOTE: No additional capacity with COM75. ABPLUG3 Abandonment Plug Assembly Complete plug assembly for abandoning an open 3" (76mm) cored-hole. Assembly includes intumescent fire-stop material to maintain the fire-classification of the floor, integral retainer ring to prevent the unit from pulling up through the floor, and a black die-cast aluminum cover. NOTE: Assembled with scrub water gasket. For use on 3 3/16" (97mm) NOTE: Not designed to work with bare concrete NOTE: To abandon RC7TFFTC Series, disconnect conduit adapters and install closure plugs. NOTE: See page 6 for specifications. Hole Size Chart Hole Size Hole Size Minimum Maximum RC7AFFTC 3 1/16" (78mm) 3 1/8" (79mm) RC7STC 3 1/16" (78mm) 3 1/8" (79mm) ABPLUG3 3 1/16" (78mm) 3 1/8" (79mm) RC7CFFTC 3 1/16" (78mm) 3 1/8" (79mm) 5

3 1/16" HOLE SIZE POKE-THRU DEVICES F RC9FFS RC9AFFTC Poke-Thru Series Ordering Information Insert Stem with Disposable Plate Furniture feed insert with one 1 1/4" and one 1/2" trade size conduit to feed power and communication services. Use with RC9CFF Series covers to form a complete RCAPFFTCBK Abandonment Plate Used to abandon fitting by removing hexagonal housing and placing plate inside the carpet flange. Insert stem must remain in the cored hole. FFD-P 3/4" (19.1mm) Threaded Drop-in Hub Used to make conduit connections to the service head. RC9CFFTCGY Finish Flange and Service Head Assembly Comes complete with gray carpet flange, gray hexagonal housing, five rubber grommets, and one 3/4" trade size threaded drop-in hub. The service head includes scrub water gasket. Use with RC9FFS Insert to form a complete TG-1 Drop-in Rubber Grommet for Pass-Through Cabling Set of two grommets (one grommet shown). RC9AFFTCGY RC9AFFTCBK 14 7/16" (367mm) Assembled Furniture Feed Unit Complete with hexagonal service head. Service head has one 3/4" trade size threaded conduit hub and five rubber grommets. The service head includes scrub water gasket. Unit is supplied with one 1 1/4" trade size conduit stem and one 1/2" trade size conduit stem to feed power and communication services. Available with a gray housing and carpet flange. ABPLUG3 Abandonment Plug Assembly Complete plug assembly for abandoning an open 3" (76mm) cored-hole. Assembly includes intumescent fire-stop material to maintain the fire-classification of the floor, integral retainer ring to prevent the unit from pulling up through the floor, and a black die-cast aluminum cover. 3 3/16" (97mm) NOTE: Service head is not to be used as a junction box. All power connections must be made in a junction box below (not supplied). NOTE: See page 6 for specifications. 6

3 1/16" HOLE SIZE POKE-THRU DEVICES F RC9AM2STC Insert Assembly with Disposable Plate Use with RC9CM2TC Series cover to complete installation. 10" (254mm) RC9AM2TC Poke-Thru Series Ordering Information RC9CM2TCGY Furniture Feed Poke-Thru RC9CM2TCBK Cover Assembly Complete RC9CM2TCAL with combination 1 1/4" and 2" trade size threaded conduit openings and closure plugs. Must be used with a conduit connector (not included) at the adapter assembly plate to maintain fire classification. Finish flange/cover assembly available in painted gray (GY), black (BK) and brushed aluminum (AL). RC9AM2TCGY Furniture Feed Poke-Thru RC9AM2TCBK Assembled Unit Complete RC9AM2TCAL with combination 1 1/4" and 2" trade size threaded conduit openings and closure plugs. Must be used with a conduit connector (not included) at the adapter assembly plate to maintain fire classification. Finish flange/cover assembly available in painted gray (GY), black (BK) and brushed aluminum (AL). RC7AM2TCGY RC7AM2TCBK RC7AM2TCAL 10" (254mm) NOTE: Assembled with scrub water gasket. For use on Furniture Feed Poke-Thru Assembled Unit 2" trade size conduit stem, complete with one 3/4" trade size conduit and two 1/2" trade size adapters and closure plugs. Finish flange/cover assembly available in painted gray (GY), black (BK), and brushed aluminum (AL). RC7CFFTCGY RC7CFFTCBK RC7CFFTCAL NOTE: Assembled with scrub water gasket. For use on Furniture Feed Poke-Thru Cover Assembly Complete with one 3/4" trade size conduit and two 1/2" trade size adapters and closure plugs. Colors available in painted gray (GY), black (BK), and brushed aluminum (AL). Use with RC9AM2STC. Insert stem to form a complete poke-thru assembly RCAPFFTCBK 10 1/4" (260mm) NOTE: Assembled with scrub water gasket. For use on Abandonment Plate Available in black (BK). NOTE: See page 6 for specifications. NOTE: Assembled with scrub water gasket. For use on ABPLUG3 Abandonment Plug Assembly Complete plug assembly for abandoning an open 3" (76mm) cored-hole. Assembly includes intumescent fire-stop material to maintain the fire-classification of the floor, integral retainer ring to prevent the unit from pulling up through the floor, and a black 3 3/16" die-cast aluminum cover. (97mm) 7

Flush Poke-Thru Series Specifications (continued) Tile, Terrazzo, Linoleum, or Carpet Scrub Water Gasket Sealtite Connector (Not Supplied) Trim Flange for Carpet or Tile Scrub Water Gasket Concrete Slab Concrete Slab 1 1/4" Trade Size EMT Conduit 5 3/4" (146mm) Long Communication Cables Retaining Flange 1/2" Trade Size EMT Conduit 8 3/4" (222mm) Long Junction Box (Not Supplied) 3/4" Trade Size EMT Conduit 1 1/4" Trade Size EMT Conduit Retaining Flange Trim Flange for Carpet or Tile Trim Flange for Carpet or Tile Concrete Slab Scrub Water Gasket Intumescent Material Retaining Flange 3/4" Trade Size EMT Conduit Concrete Slab Scrub Water Gasket Retaining Flange COM50 (Optional) Provides Two 1/2" Trade Size Threaded Openings 2" (51mm) x 6" (152mm) EMT Conduit Junction Box 24.5 cu in. (401ml) NOTE: The material that is used in Wiremold poke-thru devices is not listed under the directory for Fire Stopping Material because the poke-thru device is UL Classified as Outlet Boxes and Fittings Classified For Fire Resistance (CEYY). The pass/fail criteria comes from UL263. The pass criteria is that the poke-thru unit cannot exceed 325 F. above ambient before the concrete slab (or deck) reaches this same temperature. Some poke-thru devices are tested for 2 hours while others are tested for 4 hours. The intumescent material has never been tested as a fire-stopping material as a stand-alone device. This material is designed to work as a unit with the entire poke-thru device. ED1216R8 Updated January 2016 For latest specs visit www.legrand.us/wiremold Copyright 2013 Legrand All Rights Reserved Electrical Wiring Systems 60 Woodlawn Street West Hartford, CT 06110 Phone: 1.877.BY.LEGRAND (295-3472) www.legrand.us 570 Applewood Crescent Vaughan, Ontario L4K 4B4 Phone:905.738.9195 www.legrand.ca