TRANSPORT II " 10.5" MOUNTING POSTS FENCE LINE POST. Classic gate shown GATE OPENING CANTILEVER GATE SAFETY WARNING

Similar documents
TRANSPORT LINK CHAIN LINK CANTILEVER GATES

PASSPORT IS ROLLER GUIDE POST FENCE LINE GATE OPENING ROLL GATE SAFETY WARNING

These FenceTrac kits are designed for Tongue & Groove Type Wood and Vinyl, Bamboo or Welded Wire

AEGIS II XTREME 2 & 3-RAIL OPTIONS 4" AIR-SPACE

BULWARK BOLLARDS M30 & M50

ORNAMENTAL STEEL FENCE

Pueblo Water Resources

MONTAGE WELDED RESIDENTIAL ORNAMENTAL FENCE

HIGH SECURITY WELDED WIRE MESH FENCE

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

MONTAGE II HEAVY INDUSTRIAL MONTAGE PLUS COMMERCIAL

MONTEREY PENINSULA WATER MANAGEMENT DISTRICT ADDENDUM NO. 1 TO CONTRACT DOCUMENTS. For Construction Of BACKFLUSH BASIN EXPANSION PROJECT

HIGH SECURITY STEEL PALISADE FENCING

STALWART OPTIMA. SYSTEM REQUIRES ASSEMBLY Refer to construction specification & tables within this section for recommended post spacing

SECTION DECORATIVE METAL FENCES AND GATES

SECTION DECORATIVE METAL FENCES AND GATES

ECHELON II. Echelon II INDUSTRIAL ORNAMENTAL ALUMINUM FENCE NOTE: PANELS DO NOT COME PRE-ASSEMBLED. CURVED PICKET STYLES Span 2-1/2 3

SECTION DECORATIVE METAL FENCES AND GATES

Addendum No. 2. Item No. 3 New/Revised Drawings A. Add the attached 8 ½ x 11" drawing ESK-1 dated (revised noted), as a part of this addendum

Ultra Aluminum Fence, Rail & Gate Specifications

SPECIFICATIONS. Section Ornamental Fences and Gates

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION HIGH SECURITY WELDED WIRE ARCHITECTURAL FENCE SYSTEM

SECTION ORNAMENTAL WELDED STEEL FENCING

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

Aegis Ornamental Steel

AMEGO FENCE SYSTEM ENTER PROJECT NAME HERE 12/2011

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

ITEM 555 CHAIN LINK FENCING

Aegis Ornamental Steel

ECHELON PLUS ALUMINUM ORNAMENTAL FENCING

SECTION CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCES AND GATES

SECTION FENCING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

A. Atlantic Railing Series with Mushroom Top and Square Pickets

Residential Commercial Industrial

III. TECHNICAL SPECIFICATIONS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

INDUSTRIAL ORNAMENTAL ALUMINUM FENCE INSTITUTIONS MUNICIPAL PARKS & RECREATION SCHOOLS FENCE PRODUCTS AMERISTARFENCE.

SECTION 2831 ITEM F-162 CHAIN-LINK FENCES

Please acknowledge receipt of this Addendum No. 01 on the Bid Schedule submitted with your sealed Bid

A D D E N D U M N O. 1 LITTLE MISSOURI SPRING FENCING PROJECT PLEASANT VIEW, UTAH

ANTI RAM SECURITY CHAIN LINK FENCE - 4, MPH SECTION

METAL FABRICATION..1 General Conditions and Division 1 shall govern Work of this section.

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Trex Commercial Products page Metal Railing

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN LINK FENCING

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION CHAIN LINK FENCES

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECTION 1043 FENCE MATERIAL

A. ASTM A121 Specification for Metallic-Coated Carbon Steel Barbed Wire. B. ASTM A392 Specification for Zinc-Coated Steel Chain-Link Fence Fabric

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

Aluminum Fences of Distinction

SECTION ROOF ACCESSORIES

SPECIFICATIONS: Architectural Aluminum Railings

SECTION ACCORDION FOLDING PARTITIONS

SECTION DECORATIVE METAL RAILINGS

A. Product Data shall be provided for each type of product indicated.

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

SECTION EXTERIOR SUN SHADES

PROPOSAL FOR WROUGHT IRON PERIMETER FENCE WITH GATE TO CITY OF POMONA

SECTION STEEL WINDOWS UL Labeled Fire-Rated Horizontal Slider (900) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

SPECIFICATION FOR PERMANENT BEAM GRANDSTAND WITH INTERLOCK WELDED DECK SYSTEM

SECTION ALUMINUM HANDRAIL SYSTEMS

ROLLING RACK. Simple Security

CONTENTS SALES POLICY LITERATURE SAMPLES INSTALLATION DVDs

SECTION Coiling Counter Shutters

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

Automated Cantilevered Aluminum Sliding Gate

SECTION CHAIN LINK FENCES AND GATES

SECTION Coiling Counter Shutters

Aluminum Fences of Distinction

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION SHOWER AND DRESSING COMPARTMENTS

SECTION MISCELLANEOUS METALS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION CHAIN LINK FENCES AND GATES (PARK)

A-Series Aluminum Gantry Crane

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

GLASSWALL SPECIFICATIONS

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

SECTION SECTIONAL OVERHEAD DOORS

STATE OF NORTH CAROLINA N DEPARTMENT OF ADMINISTRATION October 24, 2012 PURCHASE AND CONTRACT DIVISION M July 31, 2009

CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS DOCUMENT 00085B ADDENDUM ADDENDUM NO. 1

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

1. Seismic Loads: Reference structural drawings.

Transcription:

TRANSPORT ESTATE TRANSPORT IS TRANSPORT LINK ADAPTRACK 2"sq x.25" UPRIGHTS & DIAGONAL BRACES 1"sq x.125" PICKETS GATE TRACKS PRE-DRILLED FOR LEFT OR RIGHT OPENINGS FENCE LINE POST 13.8125" 10.5" MOUNTING POSTS POST 8" FENCE LINE FENCE POST B A 4', 5', 6', 7'& 8' S C Classic gate shown GATE OPENING VARIES A B C ISO VIEW ISO VIEW FRONT VIEW SIDE VIEW TOP VIEW CANTILEVER GATE SAFETY WARNING Ornamental Cantilever Gates are supplied with rolls of 2" mesh safety screening in sufficient quantities to cover the entire gate (including overhang) and an equal portion of fence parallel to the gate in the open position up to a height of over 6' from ground elevation. This screening must be included when the TransPort Gate is assembled at the job site. Additionally, all of the safety requirements of ASTM F2200 must be met during installation. Failure to incorporate the safety mesh or follow ASTM F2200 safety requirements during gate assembly and installation will cause rejection of the entire gate system any time an attempt is made to attach the gate to an automatic gate operator. Ameristar assumes no responsibility for gate installations that fail to utilize the materials provided or meet the applicable safety standards. Refer to construction specification & tables within this section for more details. TO PLACE YOUR ORDER CALL 888-333-3422 VISIT AMERISTARFENCE.COM 8.1

ADAPTRACK TRANSPORT LINK TRANSPORT IS TRANSPORT ESTATE CANTILEVER GATES GATE HARDWARE & POST NOT INCLUDED HORIZONTAL STABILIZING ARM INCLUDED FOR OPENINGS OVER 24' ASSEMBLY REQUIRED 4' 5' 6' OPENING LENGTH ITEM NUMBER WEIGHT PICKET QTY 6' - 8' 144.5" 2T 04808S 223 lbs 21 8' - 10' 182.5" 2T 04810S 272 lbs 27 10' - 12' 211" 2T 04812S 324 lbs 31 12' - 14' 249" 2T 04814S 372 lbs 37 14' - 16' 287" 2T 04816S 418 lbs 42 16' - 18' 325" 2T 04818S 466 lbs 48 18' - 20' 372.5" 2T 04820S 548 lbs 55 20' - 22' 401" 2T 04822S 591 lbs 59 22' - 24' 429.5" 2T 04824S 623 lbs 63 24' - 27' 496" 2T 04827S 735 lbs 73 27' - 30' 534" 2T 04830S 782 lbs 79 6' - 8' 144.5" 2T 06008S 241 lbs 21 8' - 10' 182.5" 2T 06010S 292 lbs 27 10' - 12' 211" 2T 06012S 354 lbs 31 12' - 14' 249" 2T 06014S 372 lbs 37 14' - 16' 287" 2T 06016S 452 lbs 42 16' - 18' 325" 2T 06018S 503 lbs 48 18' - 20' 372.5" 2T 06020S 595 lbs 55 20' - 22' 401" 2T 06022S 639 lbs 59 22' - 24' 429.5" 2T 06024S 674 lbs 63 24' - 27' 496" 2T 06027S 796 lbs 73 27' - 30' 534" 2T 06030S 847 lbs 79 6' - 8' 144.5" 2T 07208S 260 lbs 21 8' - 10' 182.5" 2T 07210S 313 lbs 27 10' - 12' 211" 2T 07212S 384 lbs 31 12' - 14' 249" 2T 07214S 437 lbs 37 14' - 16' 287" 2T 07216S 487 lbs 42 16' - 18' 325" 2T 07218S 540 lbs 48 18' - 20' 372.5" 2T 07220S 643 lbs 55 20' - 22' 401" 2T 07222S 689 lbs 59 22' - 24' 429.5" 2T 07224S 725 lbs 63 24' - 27' 496" 2T 07227S 860 lbs 73 27' - 30' 534" 2T 07230S 912 lbs 79 7' & 8' S ON NEXT PAGE CLASSIC MAJESTIC GENESIS Note: All TransPort gates over 24' opening include a horizontal stabilizer arm kit. 8.2 TO PLACE YOUR ORDER CALL 888-333-3422 VISIT AMERISTARFENCE.COM

TRANSPORT ESTATE TRANSPORT IS TRANSPORT LINK ADAPTRACK CANTILEVER GATES GATE HARDWARE & POST NOT INCLUDED HORIZONTAL STABILIZING ARM INCLUDED FOR OPENINGS OVER 24' ASSEMBLY REQUIRED 7' 8' OPENING LENGTH ITEM NUMBER WEIGHT PICKET QTY 6' - 8' 144.5" 2T 08408S 278 lbs 21 8' - 10' 182.5" 2T 08410S 334 lbs 27 10' - 12' 211" 2T 08412S 415 lbs 31 12' - 14' 249" 2T 08414S 470 lbs 37 14' - 16' 287" 2T 08416S 522 lbs 42 16' - 18' 325" 2T 08418S 578 lbs 48 18' - 20' 372.5" 2T 08420S 692 lbs 55 20' - 22' 401" 2T 08422S 740 lbs 59 22' - 24' 429.5" 2T 08424S 777 lbs 63 24' - 27' 496" 2T 08427S 924 lbs 73 27' - 30' 534" 2T 08430S 979 lbs 79 6' - 8' 144.5" 2T 09608S 297 lbs 21 8' - 10' 182.5" 2T 09610S 356 lbs 27 10' - 12' 211" 2T 09612S 446 lbs 31 12' - 14' 249" 2T 09614S 504 lbs 37 14' - 16' 287" 2T 09616S 558 lbs 42 16' - 18' 325" 2T 09618S 617 lbs 48 18' - 20' 372.5" 2T 09620S 741 lbs 55 20' - 22' 401" 2T 09622S 791 lbs 59 22' - 24' 429.5" 2T 09624S 830 lbs 63 24' - 27' 496" 2T 09627S 989 lbs 73 27' - 30' 534" 2T 09630S 1047 lbs 79 = FENCE STYLES AVAILABLE C = Classic M = Majestic G = Genesis I = Invincible = COLOR OPTIONS AVAILABLE B = Black N = Bronze W = White S = Sand CLASSIC MAJESTIC GENESIS INVINCIBLE Note: All TransPort gates over 24' opening include a horizontal stabilizer arm kit. TO PLACE YOUR ORDER CALL 888-333-3422 VISIT AMERISTARFENCE.COM 8.3

ADAPTRACK TRANSPORT LINK TRANSPORT IS TRANSPORT ESTATE GATE POSTS & POST CAPS STEEL POSTS 4"sq. x 11ga. 6"sq. x.1875 wall POST LENGTH ITEM NUMBER WEIGHT 6' P 40072 39 lbs 7' P 40084 47 lbs 8' P 40096 54 lbs 9' P 40108 61 lbs 10' P 40120 67 lbs 11' P 40132 74 lbs 12' P 40144 81 lbs 13' P 40156 87 lbs 14' P 40168 94 lbs 15' P 40180 101 lbs 16' P 40192 108 lbs 18' P 40216 114 lbs 20' P 40240 126 lbs 24' P 40288 162 lbs 7' P 60084 102 lbs 8' P 60096 116 lbs 9' P 60108 131 lbs 10' P 60120 145 lbs 11' P 60132 160 lbs 12' P 60144 174 lbs 13' P 60156 189 lbs 14' P 60168 203 lbs 15' P 60180 218 lbs 16' P 60192 232 lbs = COLOR OPTIONS AVAILABLE B = Black N = Bronze W = White S = Sand NOTE: In locations subject to freezing temperatures, where posts are grouted into core-drilled holes, a.25" diameter hole should be drilled into the post approximately.5" above the elevation to allow for drainage of ground water build-up. The drilled hole must be wiped clean and be dry prior to applying Ameristar zinc primer and color finish. STANDARD FLAT CAP Steel CAP SIZE ITEM NUMBER WEIGHT 4"sq. A 509.4 lbs 6"sq. A 515.8 lbs 8.4 TO PLACE YOUR ORDER CALL 888-333-3422 VISIT AMERISTARFENCE.COM

TRANSPORT ESTATE TRANSPORT IS TRANSPORT LINK ADAPTRACK CANTILEVER GATE HARDWARE 4" sq. x 11 ga. MINIMUM POST SIZE REQUIRED FOR CANTILEVER GATE INSTALLATION DESCRIPTION ITEM NUMBER BOX QTY WEIGHT 4" sq. Post Gate Kit TGKODN1 1 80 6" sq. Post Gate Kit TGKOD-6N1 1 90 Kits include: (4) Truck Assemblies / 6-wheel (4) Truck Brackets / U-Bolts 4" or 6" sq. per kit size (2) Cantilever Gate Latch / Yolk & Receiver (2) Gate Stops DESCRIPTION ITEM NUMBER BOX QTY WEIGHT 4" sq. Post Bi-Parting Gate Kit TGKODB 1 80 Kits include: (8) Truck Assemblies / 6-wheel (8) Truck Brackets / U-Bolts 4" sq. per kit size (1) Gate Latch (4) Gate Stops TRUCK ASSEMBLY TRUCK BRACKET TO PLACE YOUR ORDER CALL 888-333-3422 VISIT AMERISTARFENCE.COM 8.5

ADAPTRACK TRANSPORT LINK TRANSPORT IS TRANSPORT ESTATE CONSTRUCTION SPECIFICATION 32 31 00 ORNAMENTAL CANTILEVER GATE SYSTEM PART 1 - GENERAL 1.01 WORK INCLUDED The contractor shall provide all labor, materials and appurtenances necessary for installation of the industrial ornamental cantilever gate system defined herein at (specify project site). 1.02 RELATED WORK Section - Earthwork Section - Concrete 1.03 SYSTEM DESCRIPTION The manufacturer shall supply a total industrial ornamental cantilever gate system of the Ameristar TransPort II (specify Classic, Majestic, Genesis or Invincible ) design. The system shall include all components (i.e., tracks, uprights, bracing, pickets, hardware, fittings, and fasteners) required. 1.04 QUALITY ASSURANCE The contractor shall provide laborers and supervisors who are thoroughly familiar with the type of construction involved and materials and techniques specified. 1.05 REFERENCES ASTM A653/A653M Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy Coated (Galvannealed) by the Hot-Dip Process ASTM B117 Practice for Operating Salt-Spray (Fog) Apparatus ASTM B221 Aluminum and Aluminum Alloy Extruded Bars, Shapes and Tubes ASTM D523 Test Method for Specular Gloss ASTM D714 Test Method for Evaluating Degree of Blistering in Paint ASTM D822 Practice for Conducting Tests on Paint and Related Coatings and Materials using Filtered Open-Flame Carbon-Arc Light and Water Exposure Apparatus ASTM D1654 Test Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments ASTM D2244 Test Method for Calculation of Color Differences from Instrumentally Measured Color Coordinates ASTM D2794 Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact) ASTM D3359 Test Method for Measuring Adhesion by Tape Test 1.06 SUBMITTAL The manufacturer's submittal package shall be provided prior to installation. 1.07 PRODUCT HANDLING AND STORAGE Upon receipt at the job site, all materials shall be checked to ensure that no damages occurred during shipping or handling. Materials shall be stored in such a manner to ensure proper ventilation and drainage, and to protect against damage, weather, vandalism and theft. PART 2 - MATERIALS 2.01 MANUFACTURER All industrial ornamental aluminum cantilever gates shall conform to the Ameristar TransPort II gate system, (specify Classic, Majestic, Genesis, or Invincible) design, manufactured by Ameristar Fence Products, Inc., in Tulsa, Oklahoma. The project gate schedule shall include the following additional information for each cantilever gate included in the project scope: (specify nominal opening size in feet) opening, (specific nominal height in feet) height, (specify direction of gate travel to the open position, right or left, viewing from outside fence line looking in) gate travel direction. 2.02 MATERIAL A. The materials used for cantilever gate framing (uprights & diagonal bracing) shall be manufactured from ASTM B221 aluminum (designation 6063-T-6) with yield strength of 25,000 PSI, a tensile strength of 30,000 PSI and a standard mill finish. The TransPort enclosed tracks shall be manufactured from ASTM B221 aluminum (designation 6063-T-6) with a yield strength of 25,000 PSI, a tensile strength of 30,000 PSI and a standard mill finish. B. Material for pickets shall be 1" square x 1/8" wall aluminum pickets. Picket on center spacing shall not exceed 5". Pickets shall be securely fastened to face of top and bottom enclosed track extrusions. C. Material for gate uprights and diagonal bracing shall be 2" square x ¼" wall aluminum. The cross-sectional shape of the top and bottom enclosed-track shall confirm to the manufacturers Fast-Trak design with as a single extrusion consisting of a 2" x 5" channeled support with integrated 2" x 2" enclosed-track raceway. D. Steel material for fence posts shall be galvanized prior to forming in accordance with the requirements of ASTM A653/A653M, with minimum yield strength of 45,000 psi (310 MPa). The steel shall be hot-dip galvanized to meet the requirements of ASTM A653/A653M with a minimum zinc coating weight of 0.90 oz/ft 2 (276 g/m 2 ), Coating Designation G-90. Material for gate support posts shall be 4" square x 11 Ga. tubing. E. Suspension Rollers for top and bottom tracks shall be used at each support post to track connection. Each truck assembly shall be capable of being adjusted vertically via threaded rod for fine-tune adjustment. Truck assembly shall 8.6 TO PLACE YOUR ORDER CALL 888-333-3422 VISIT AMERISTARFENCE.COM

TRANSPORT ESTATE TRANSPORT IS TRANSPORT LINK ADAPTRACK CONSTRUCTION SPECIFICATION 32 31 00 ORNAMENTAL CANTILEVER GATE SYSTEM be constructed in a way so that the primary housing for the truck rollers shall pivot via ball-bearing connection to threaded rod. 2.03 FABRICATION A. Gate frame uprights and diagonal bracing shall be prefabricated and pre-punched to accept frame fasteners. Enclosed track shall be pre-punched to accept gate uprights. Pickets shall be precut to specified length and predrilled to accept picket to track fasteners. Posts shall be precut to specified lengths. B. Top and bottom enclosed track extrusions shall be mechanically fastened to vertical gate uprights and intermediate supports, as required by assembly instructions. Diagonal bracing shall be mechanically fastened to vertical gate uprights and intermediate supports, as required by assembly instructions. Pickets shall be mechanically fastened to top and bottom enclosed track, as required by assembly instructions. C. The manufactured gate components shall be subjected to the Ameristar thermal stratification coating process (high-temperature, in-line, multi-stage, and multi-layer) including, as a minimum, a six-stage pretreatment/wash and an electrostatic spray application of a polyester finish. The topcoat shall be a no-mar TGIC polyester powder coat finish with a minimum thickness of 2 mils (0.0508mm). The color shall be (specify Black, Bronze, White, or Desert Sand). The stratification-coated framework shall be capable of meeting the performance requirements for each quality characteristic shown in Table 1. PART 3 - EXECUTION 3.01 PREPARATION All new installation shall be laid out by the contractor in accordance with the construction plans. 3.02 GATE INSTALLATION A. Cantilever support posts shall be set in concrete footers having a minimum depth of 48" (Note: In some cases, local restrictions of freezing weather conditions may require a greater depth). The Earthwork and Concrete sections of this specification shall govern material requirements for the concrete footer. Posts setting by other methods such as plated posts or grouted core-drilled footers are permissible only if shown by engineering analysis to be sufficient in strength for the intended application. B. Gate to be installed per manufacturers gate installation instructions. Gate shall be installed in compliance with ASTM F2200 standards. 3.03 GATE INSTALLATION MAINTENANCE When cutting/drilling posts adhere to the following steps to seal the exposed steel surfaces; 1) Remove all metal shavings from cut area. 2) Apply zinc-rich primer to thoroughly cover cut edge and/or drilled hole; let dry. 3) Apply 2 coats of custom finish paint matching fence color. Failure to seal exposed surfaces per steps 1-3 above will negate warranty. Ameristar spray cans or paint pens shall be used to prime and finish exposed surfaces; it is recommended that paint pens be used to prevent overspray. Use of non-ameristar parts or components will negate the manufactures warranty. 3.04 GATE INSTALLATION Gate posts shall be spaced according to the manufacturers drawings, dependent on clear opening. The manufacturers gate drawings shall identify the necessary gate hardware required for the application. Gate hardware shall be provided by the manufacture of the gate and shall be installed per manufacturer s recommendations. 3.05 CLEANING The contractor shall clean the jobsite of excess materials; posthole excavations shall be scattered uniformly away from posts. TABLE 1 COATING PERFORMANCE REQUIREMENTS QUALITY CHARACTERISTICS ASTM TEST METHOD PERFORMANCE REQUIREMENTS ADHESION D3359 METHOD B Adhesion (retention of coating) over 90% of test area (tape and knife kit test). CORROSION RESISTANCE B117, D714, D1654 Corrosion resistance over 1,000 hours (scribed per D1654; failure mode is accumulation of 1/8" coating loss from scribe or medium #8 blisters) IMPACT RESISTANCE D2794 Impact resistance over 60" lb. (forward impact using 0.625" ball). WEATHERING RESISTANCE D822 D2244, D523 (60o method) Weathering resistance over 1,000 hours (failure mode is 60% loss of gloss or color variance of more than 3 delta-e color units). TO PLACE YOUR ORDER CALL 888-333-3422 VISIT AMERISTARFENCE.COM 8.7

ADAPTRACK TRANSPORT LINK TRANSPORT IS TRANSPORT ESTATE 8.8 TO PLACE YOUR ORDER CALL 888-333-3422 VISIT AMERISTARFENCE.COM