SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

Similar documents
ACOUSTICAL WALL TREATMENT 09840

SECTION ACOUSTICAL WALL TREATMENT (CEMENTITIOUS WOOD FIBER WALL PANELS)

Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3. Tel Fax Web

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)

SECTION (09800) - Suspended Acoustic Baffles. This Section is based on TECHLITE Accent Linear Ceiling Baffles.

SECTION (SOLID/ENGINEERED BAMBOO-EXTERIOR GRADE PRODUCTS)

5GLOBAL. specification guide summary PART 1 GENERAL

FABRICOIL BASIC January 10, 2006

SECTION SOUND-ABSORPTIVE PANELS

DiSorb Diffuser Product Specifications Section Sound Diffuser-Absorber for Ceilings and Walls (DiSorb Diffuser-Absorber)

APPLICABLE UNDER SECTIONS: SOLAR ENERGY HEATING EQUIPMENT SOLAR HEATING COLLECTORS METAL WALL PANELS

SECTION WEATHERSTRIPPING & SEALS (THRESHOLDS AND RAMP THRESHOLDS)

Specifier Note: Retain material(s) below to conform to project requirements.

Section Domestic Water Piping (Hot and Cold Water Potable Water Distribution)

SECTION CEMENTITIOUS ROOF DECK (CEMENTITIOUS WOOD FIBER PLANK)

SECTION SONEX Acoustical Wall Treatment

Dricon FRT Wood Specification

SECTION METAL WALL PANELS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

THERMAL INSULATION

SECTION ACOUSTICAL CEILINGS

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

PRODUCT SPECIFICATIONS

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER

SECTION ACOUSTICAL PANEL CEILINGS

Division 9: Section RESILIENT ATHLETIC SURFACING (Regupol AktivLok Recycled Rubber)

POLYCAST Trench Drain Systems

Sample Specification

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

SECTION SOUND-ABSORPTIVE PANELS

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Regupol AktivPro RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER MOLDED TILES

Sample Specifications

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

NatureWood Construction Product Specification Guide

SECTION METAL WALL PANELS

HIR 1 ACOUSTICAL, IMPACT RESISTANT, TACKABLE WALL PANEL SPECIFICATION

Doc

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

SECTION STAINLESS STEEL FLEXIBLE CABLE MESH. Show hidden Specifier Notes for best results

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

PIPING SPECIALTIES 15120

Hospitals Soundproofing. Hospital Soundproofing & Soundproofing Solutions

Section Wood Veneer Ceiling Tiles Micro Perforated

LAMINATED VENEER LUMBER

Section Wood Veneer Ceiling Planks Linear

SECTION EXTERIOR SUN SHADES

Geometrik Manufacturing Inc.

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

Section SoundPly LR M25 Acoustic Ceiling Panels

TRUMAN STATE UNIVERSITY OPHELIA PARRISH FINE ARTS CENTER ACOUSTICAL RENOVATIONS

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ

ACOUSTICAL WALL TREATMENT SECTION 09840

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

Section SoundPly RF M25 Acoustic Wall Panels

UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

Product Guide Specification Pliteq GenieMat RST-02, RST-05, RST-10, RST-12, RST-15

Sample Specifications

SECTION WALL AND DOOR PROTECTION

CONCRETE BALUSTRADE SYSTEM

Guide Specifications Section Wood Ceiling Coffers

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

Section Wood Grille Ceiling Panels

Ecore Athletic Elevate Roster Interlocking Carpet Tile GUIDE SPECIFICATIONS Ecore

LINEAR METAL CEILINGS Section

SECTION DOOR HARDWARE (DOOR BOTTOMS)

SECTION FOAMED-IN-PLACE INSULATION

SECTION METAL WALL PANELS

Product Guide Specification Pliteq GenieMat FF06, GenieMat FF10, GenieMat FF17, GenieMat FF25, GenieMat FF50, GenieMat FF75

Expansion Joint Covers

SECTION COMPOSITE CORE ACOUSTICAL PANEL CEILINGS. Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3

Pinnacle 2 Carpet Tile GUIDE SPECIFICATIONS Ecore

SECTION ACCORDION FOLDING PARTITIONS

Ceiling Tiles C200B - Specification

Accella Polyurethane Systems, LLC

1. ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers-Tension.

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SPECIFICATION GUIDELINE

1. Amarco Products Athletic Recycled Rubber Sports Flooring Rolls and Interlocking Tiles 2. Adhesives

Office Soundproofing. Office Soundproofing & Soundproofing Solutions

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

Phenolic Exterior Wall Cladding

Acrylitex Tilt UP Primer Guide Specification Revised August 1, 2008

Vinyl Rx GUIDE SPECIFICATIONS Ecore Commercial

SPECIFICATION GUIDELINE

Specifier Note: Coordinate the following Article with Section Protecting Installed Construction.

EXTERIOR PLANK SERIES SPECIFICATION DATA

Expansion Joint Covers (079513)

Construction Standards PAGE

CSI Exceed PART 1.0 GENERAL. plae.us SUMMARY 1.2 REFERENCES

SECTION ACOUSTICAL CEILINGS

SECTION ACOUSTICAL PANEL CEILINGS

Transcription:

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS PART 1 GENERAL 1.01 SUMMARY Specifier Note: Revise paragraphs below to suit project requirements. A. Section Includes: Custom fabricated acoustical baffles and clouds Specifier Note: Article below may be omitted when specifying manufacturer s proprietary products and recommended installation. Retain Reference Article when specifying products and installation by an industry reference standard. If retained, list standard(s) referenced in this section. Indicate issuing authority name, acronym, standard designation and title. Establish policy for indicating edition date of standard referenced. Conditions of the Contract or Division 1 References Section may establish the edition date of standards. This article does not require compliance with standard, but is merely a listing of references used. Article below should list only those industry standards referenced in this section. 1.02 REFERENCES A. ASTM International: 1. ASTM C423 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method. 2. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials. 3. ASTM E795 Standard Practices for Mounting Test Specimens During Sound Absorption Tests. Specifier Note: Article below should be restricted to statements describing design or performance requirements and functional (not dimensional) tolerances of a complete system. Omit descriptions to composite and operational properties to extent necessary to link multiple components of a system and to interface with other systems. 1.03 SYSTEM DESCRIPTION A. Performance Requirements: 1. Surface Burning Characteristics (ASTM E84): a. Flamespread: 25, maximum. b. Smoke Developed: 450, maximum. Specifier Note: Article below includes submittal of relevant data to be furnished by Contractor before, during or after construction. Coordinate this article with Architect s and Contractor s duties and responsibilities in Conditions of the Contract and Division 1 Submittal Procedures Section. 1.04 SUBMITTALS A. General: Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedures Section. B. Product Data: Submit product data sheet, for specified products. C. Shop Drawings: Submit shop drawings showing layout, edge profiles and baffle / cloud components, including suspension method, accessories, finish colors and textures. D. Samples: Submit selection and verification samples of finishes, colors and textures. E. Test Reports: Certified test reports showing compliance with specified performance requirements. 1. Standard Systems: Submit certified copies of previous test reports substantiating performance of system in lieu of retesting. Specifier Note: Article below should include prerequisites, standards, limitations and criteria that establish an overall level of quality for products and workmanship for this section. Coordinate article below with Division 1 Quality Assurance Section. 1.05 QUALITY ASSURANCE Specifier Note: Paragraph below should list obligations for compliance with specific code requirements particular to this section. General statements to comply with a particular code are typically addressed in Conditions of the Contract and Division 1 Regulatory Requirements Section. Repetitive statements should be avoided. A. Regulatory Requirements and Approvals: [Specify applicable requirements of regulatory agencies.].

1. [Code agency name]. a. [Report or approval number]. Specifier Note: Article below should include special and unique requirements. Coordinate article below with Division 1 Product Requirements Section. 1.06 DELIVERY, STORAGE & HANDLING A. General: Comply with Division 1 Product Requirements Section. B. Delivery: Deliver materials in manufacturer s original, unopened, undamaged containers with identification labels intact. C. Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperature and humidity conditions. Environmental conditions required for storage are the same as for installation, see 1.07 A, Project Conditions. 1.07 PROJECT CONDITIONS A. Environmental Requirements: Do not install baffles or clouds until wet work, such as concrete and plastering, is complete; the building is enclosed; and the temperature and relative humidity are stabilized at 60-80 degrees F (16-27 degrees C) and 40% to 50%, respectively. PART 2 PRODUCTS Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance characteristics, material standards and descriptions as applicable. Use of such phrases as or equal or or approved equal or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal and regulatory) and assignment of responsibility for determining or equal products. 2.01 ACOUSTICAL BAFFLES/ CLOUDS Specifier Note: Paragraph below is an addition to CSI SectionFormat. Retain or delete paragraph below per project requirements and specifier s practice. A. Manufacturer: Noise Control USA. Specifier Note: Edit Paragraph below to suit project requirements. If substitutions are permitted, edit text below. Add text to refer to Division 1 Project Requirements (Product Substitutions Procedures) Section. B. Substitutions: No substitutions permitted. Specifier Note: Paragraphs below list proprietary acoustical baffles/ clouds offered by Noise Control USA. Select baffle or cloud type(s) appropriate to project. Baffles and Clouds are custom fabricated. Consult manufacturer regarding product options. Select product characteristics required; delete characteristics not required. Refer to manufacturer s technical product information. 2.02 MANUFACTURED UNITS A. PAB Baffles: 1. Thickness shall be 1 ¾ inches 2. Size: As indicated on drawings up to a maximum 48 inch (1219 mm) x 96 inch (2438 mm) 3. Core: 1 ½ inch thick, 3 pcf density fiberglass with an extruded PVC frame 4. Edge Detail: Rounded pencil 5. Facing: [100% Polyester fabric, FR701 style 2100 by Guilford of Maine] [Factory approved customer selected fabric] a. Color: [As selected from panel manufacturers stocked range of colors] [As selected from fabric manufacturers full range of colors] 6. Sound Absorption (ASTM C423) : Sabins per square foot of baffle minimum- 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz.26.62 1.23 1.81 1.9 1.95 Testing of baffles in a typical vertically suspended layout 7. Mounting: Suspension wire, cable, or chain attached to the Zinc plated steel eye screws at the top of each B. KB 803 Baffles 1. Thickness: shall be 1 ½ inches 2. Size: As indicated on drawings up to a maximum 48 inch (1219 mm) x 96 inch (2438 mm)

3. Core: 1 ½ inch thick, 3 pcf density fiberglass 4. Facing: Baffles shall be heat sealed in a fire retardant 3 mil minimum and 4 mil maximum vinyl film a. Color: As selected from panel manufacturer s standard vinyl s. 5. Sound Absorption (ASTM C423): Sabins per square foot of baffle minimum- 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz.25.74 1.49 1.80 1.53.98 Testing of baffles in a typical vertically suspended layout 6. Mounting: Suspension wire, cable, or other approved hanging mechanism attached to plated brass eyelets which are part of the C. Wave Baffles Type SE 1. Baffles shall be nominal 2 thick 2. Size: As shown in drawings up to a maximum 4 ft. wide and 30 ft. long 3. Core shall be 2 thick fiberglass, 1.5 pcf density 4. Facing: [1.5 ounce sewn ripstop sailcloth] [Webcore Vinyl] All edges face wrapped and stitched. Suspension eyelets across each 4 ft. side as required. Specifier Note: Webcore Vinyl recommended for natatorium/ indoor pool applications. a. Color: As selected from the manufacturer s standard range of FR, fire rated materials. 5. Sound Absorption (ASTM C423, J Mounting): Sabins per square foot of baffle to meet the following minimums in each frequency band 125Hz 250Hz 500Hz 1000Hz 2000Hz.46.80 1.26 1.47 1.25 Testing of baffles in a typical horizontally suspended catenary position. Type E400 mounting is not acceptable. 6. Mounting: Wire, cable, or other approved hanging mechanism attached to brass plated eyelets. Specifier Note: For corrosive environments, specify stainless steel eyelets. D. Wave Baffle Type HB 1. Baffles shall be a nominal 1-1/2 inch thick fiberglass insulation blanket fully encapsulated in a [solid] [perforated] vinyl covering which is heat sealed on the edges. Vinyl shall be no less than 2.5 mils thick. Specifier Note: Other insulation thicknesses are available. Our standard of 1-1/2 inch thick insulation is based on economy and performance which is primarily the result of the positioning of the sound absorptive baffles and to a much lesser degree the insulation thickness. 2. Size: As shown on drawings up to a maximum 4 ft. wide and 30 ft. long 3. Color: As selected from the manufacturer s standard range of FR, fire rated materials. 4. Suspension on the ends of each baffle (4 ft. maximum width) shall be through a mounting bracket which is [a solid wood spreader board covered in vinyl (Standard)] [an aluminum spreader bar] the full width of the 5. Sound Absorption (ASTM C423, JMounting) Sabins per square foot of baffle to meet the following minimums in each frequency band 125Hz 250Hz 500Hz 1000Hz 2000Hz.51.56.93 1.12 1.08 (Perforated vinyl one side).49.67 1.05 1.33.98 (Solid vinyl) Testing of baffles must be in a typical horizontally suspended catenary position replicating a ceiling/roof installation. Type E400 mounting is not acceptable. 6. Mounting: Wire, cable, or other approved hanging mechanism attached through the mounting bracket. 7. Vertically hung baffles, as shown on the drawings, will be suspended through attachment at a top mounting bracket on one end of the baffle or through grommets designed to carry the baffle weight without tearing or pulling out.

E. Hard Side Baffles 1. Thickness shall be [1inch (25.4 mm)] [2 inches (51 mm)] [4 inches (102)] 2. Size: As indicated on the drawings up to a maximum 48 inch (1219 mm) x 120 inch (3048 mm) 3. Core: 2 layers of 6-7 pcf density fiberglass bonded for the required thickness. 4. Edge Detail: [Square] [Round] [Mitered] [Beveled] [Pencil] hardened with non-resin, Class A hardening solution. 5. Facing: 100% polyester fabric, FR 701 Style 2100 by Guilford of Maine [Factory approved customer selected fabric] a. Color: [As selected from panel manufacturer s stocked range of colors] [As selected from fabric manufacturer s full range of colors]. 6. Sound Absorption (ASTM C423): Noise Reduction Coefficient as follows: a. 1 (25.4 mm) Panel: 0.80, minimum b. 2 (51 mm) Panel: 1.00, minimum c. 4 (102 mm) Panel: 1.10, minimum Baffle panels tested with an A mounting (flush) to hard surface. Suspension from ceiling will increase sound absorption. 7. Mounting: Suspension wire, cable, or chain attached to the Zinc plated steel eye screws at the top of each F. Hard Side Cloud Acoustical Panels 1. Thickness: [ 1 inch (25.4 mm)] [ 2 inch (51mm)] 2. Size as indicated on the drawings up to a maximum 48 inch (1219 mm) x 120 inch (3048 mm) cloud panel. 3. Core: [ 1 inch (25.4) m] [ 2 inches (51mm)] thick fiberglass, 6-7 pcf density 4. Edge Detail: [Square] [Round] [Mitered] [Beveled] [Pencil] edges hardened with a non-resin, Class A hardening solution. 5. Facing: [100% polyester fabric, FR 701 Style 2100 by Guilford of Maine] [Factory approved customer selected fabric]. a. Color: [As selected from panel manufacturer s stocked range of colors] [As selected from fabric manufacturer s full range of colors]. 6. Sound Absorption (ASTM C423): Noise Reduction Coefficient as follows: a. 1 inch (25.4 mm) Panel: 0.80, minimum. b. 2 inches (51 mm) Panel: 1.00, minimum. Cloud panels tested with an A mounting (flush) to hard surface. Suspension below ceiling will increase sound absorption. 7. Mounting: Suspend cloud panels using wire, cable or other acceptable mechanism attached to eye screws on the back unfaced side of the cloud panels. G. Applique Cloud Acoustical Panels 1. Thickness: [1 ½ inches (38 mm)] [2 ½ inches (64 mm)] 2. Size: As indicated on the drawings up to a maximum 48 inch (1219 mm) x 96 inch (2438 mm) cloud panel. 3. Core: [1 inch (25.4 mm)] [2 inches(51mm)] thick fiberglass, 3 pcf density with an extruded aluminum frame 4. Edge Detail: Pencil 5. Facing: [100% Polyester fabric, FR701 style 2100 by Guilford of Maine] [ Factory approved customer selected fabric] a. Color: [As selected from manufacturers stocked range of colors] [As selected from manufacturers full range of colors] 6. Sound Absorption (ASTM C423): Noise Reduction Coefficient of.85 minimum for a 1 ½ inch (38 mm) panel. Cloud panel tested with an A mounting (flush) to hard surface. Suspension from the ceiling will increase sound absorption. 7. Mounting: Suspend cloud panels using wire, cable, or other acceptable mechanism attached to clips on the panel frame. PART 3 EXECUTION Specifier Note: Paragraph below is an addition to CSI Section Format and a supplement to specifications. Retain or delete paragraph below per project requirements and specifier s practice.

3.01 MANUFACTURER S INSTRUCTIONS A. Compliance: Comply with manufacturer s product data, including product technical bulletins, product catalog installation instructions and product carton instructions for installation. 3.02 EXAMINATION A. Site Verification of Conditions: Verify that the supporting structure for suspension of acoustical baffles or clouds previously installed under other sections, is acceptable for product installation in accordance with manufacturer s instructions. 3.03 CLEANING 1. Do not install baffles or clouds until unsatisfactory conditions are corrected. A. Follow manufacturer s instructions for cleaning baffles or clouds soiled during installation. Replace baffles or clouds that cannot be cleaned to as new condition. B. Keep site free from accumulation of waste and debris. END OF SECTION