TESTING DATA. Decades Of Proven Performance gerkin.com

Similar documents
58F ALUMINUM FIXED WINDOW gerkin.com

VINYL SINGLE HUNG WINDOW

COLORS CW40/CW60/CW90 FEATURES ONLINE INFORMATION

COLORS LC-45/LC-50 FEATURES ONLINE INFORMATION

Gerkin COMFORT SERIES CONTENTS

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

Architectural Manual

Architectural Manual

CertainTeed BRIGHTIDEAS DESIGN AND BUILD THE DISTINCTIVE HOMES THAT SELL WITH NEW CASTLE XT WINDOWS AND DOORS.

TheVistaSeries. by AMSCO Windows. amscowindows.com

Milgard Windows & Doors. Training Module Building Codes and Ratings

Section Aluminum Windows (4500 Series Specifications)

The Alternative to Storefront. Gerkin Model 58F

Section Aluminum Windows (2700 Model Specifications)

Empire Series Windows

Marvin Commercial Solutions

Introducing our new high-performance thermal curtain wall, windows, entrances and storefronts. thermal

SECTION VINYL (PVC) WINDOWS

Section Aluminum Windows (M-85 Series Specifications)

Section Aluminum Windows (2700 Model Specifications)

Section Aluminum Windows (M950/M950B Series Specifications)

Veka Evolutions Commercial Window Program

TheArtisanSeries. by AMSCO Windows. amscowindows.com

Aluminum Windows and Doors

Masters Grande Series Windows with a Masterful Blend of Style, Design & Energy Efficiency

THERMALLY BROKEN ALUMINUM SERIES

Engineered Specifically for New Construction Applications

Replacement Window Buyers Guide

Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications)

GT6200 SERIES DATA SHEET

Richlin 500 Casement. Hayfield Window & Door HAYFIELD, MN 55940

AMBASSADOR. Yellow Dog Window S E R I E S. Visit our website at

SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW

Georgian Window Series

SERIES 8510 AW-PG85-FW FIXED WINDOW

KOLBE W INDQUEST S ERIES. See the Difference Quality Makes

SERIES 2100 CW-PG60-FW FIXED WINDOW

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: CUSTOM VINYL PRODUCTS, LLC

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: MGM INDUSTRIES. SERIES/MODEL: 4600 Double Hung

4600 Series Specifications (Section 08520)

SERIES /8 HORIZONTAL SLIDING WINDOW (CW30)

Impact-Resistant Windows and Doors. impact-resistant package

WD66 The Standard Wood Framed Folding System

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

HomeMaker3 Windows and Doors

Remodeling & Replacement Windows and Doors

New Construction Windows and Doors

VINYL PRODUCTS CATALOG

... N e w C o n s t r u c t i o n V i n y l C a t a l o g

A Natural Fit. REPLACEMENT SERIES HIGH PERFORMANCE, LOW MAINTENANCE. ECOLOGY

/SIM BuyLine 1599

Series B450 Guide Specification

BUILT AROUND YOU ENERGY-EFFICIENT SOLUTIONS

LEED v4 Credit Guidance for Andersen Products LEED for Building Design and Construction: Homes and Multifamily Midrise

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: MGM INDUSTRIES. SERIES/MODEL: 4600 Picture Window

BC Energy Efficiency Act - Regulatory Proposal for Window and Door Products

Crestline. Fiberglass Clad Wood Windows

Glossary. 4 P age. Air Chambers Small honeycomb spaces within the sash and frame extrusions that help to insulate and strengthen the window.

HUNG & SLIDING WINDOWS ALUMINUM WINDOWS

WD66 The Standard Wood Framed Folding System

SECTION ALL ULTREX DOUBLE HUNG WINDOW

PRODUCT SPECIFICATION UNITIZED CURTAIN WALL THERMALLY BROKEN ALUMINUM AWNING/ FIXED WINDOW

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Condensation on Indoor Glass Surface

Brussels Window. Good Windows. Windows. Objectives. Why Good Windows? Windows. Need to control. Learn. Functions: Same as wall - plus.

Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: DRAFT

Series SX45 Horizontal Slider Series FX45 Fixed 4 1/2" High Performance Thermal, Architectural Grade Windows

e n v i r o n m e n t

Imperial Series Vinyl Windows & Patio Doors

commercial advantages

SERIES 8700 VINYL REPLACEMENT WINDOWS

Milgard Quiet Line Series Vinyl Windows 3-Part Specification

Series 890-I Equa-Vu Heavy Commercial Projected Window

B-Pro safeguard, Inc.

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

PROJECTED & CASEMENT WINDOWS ALUMINUM WINDOWS

Exceed Your Expectations Today And Well Into the Future.

Beauty and Elegance Without the Maintenance.

california energy contractors, inc.

SERIES 5100 AW-PG100-FW FIXED WINDOW

VINYL CLASSICS NORTHERN CLASSICS

Series 510-I Thermal Heavy Commercial Projected Window

BAINBRIDGE LUXURY EDITION BEAUTY EFFICIENCY SECURITY DURABILITY

Residential windows and doors

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

Residential windows and doors

Multi-Cavity Insulating Glass Units

All Seasons Door and Window, Inc. SIMULATION PERFORMANCE & SOLAR HEAT GAIN REPORT. V700 Vertical Slider Double Hung NCTL

energywall e windows + patio

SECTION SERIES 200 DOUBLE-HUNG VINYL WINDOWS

I N D E X. GENERAL Inline Fiberglass Ltd: A Company Profile 1 Fiberglass Windows in Architecture 2 Characteristics of Fiberglass 3

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: TUBELITE, INC.

CTB Commercial Aluminum Window

Selecting Energy Efficient Replacement Windows in Florida

Replacement Windows and Doors that fit by

The Aluminum Framed Monumental Folding/Paired Panel System

Transcription:

Decades Of Proven Performance Our primary focus has been to manufacture energy saving window and door products. Throughout our history, we have established our selves as an innovator in the design and manufacturing capability of insulated windows and doors. We go to great lengths to make sure our Rhino Series Aluminum window and door products are the best they can be. Our products are tested by independent laboratories to ensure quality and performance. Our windows and doors are rated and certified by The American Architectural Manufacturers Association (AAMA) and the National Fenestration Rating Council (NFRC).

5045 HORIZONTAL SLIDER TEST RESULTS 5900 SINGLE HUNG TEST RESULTS U-Value w/loé3/argon.37 Solar Heat Gain Coefficient 2.24 Visible Transmittance 3.54 Condensation Resistance 45 U-Value Air Only*.42 U-Value w/loé 3 /Argon.38 Visible Transmittance.53 Condensation Resistance 48 U-Value Air Only*.43 Test Window 120 x 64 ) 1 Indoor/Outdoor Sound Transmission Sound Tranmission LC-PG45-HS.04 cfm/sq.ft. 6.90 psf 67.5 psf AAMA Rating A440-08 Test Window 108 x 60 (X0X) Sound Tranmission (w/ 1/4 LAM X 1/8 A) 31 28 w/ 1/4 LAM X 1/8 A 31 w/ 1/4 LAM X 1/8 A LC-PG50.06 cfm/sq.ft. 7.50 psf 75.0 psf AAMA Rating A440-08 Test Window 54 x 90 LC-PG50-H.03 cfm/sq.ft. 7.50 psf 75.0 psf U-Value w/loé 3 /Argon.38 Visible Transmittance.53 Condensation Resistance 48 Sound Tranmission (w/ 1/4 LAM X 1/8 A) 31 U-Value Air Only*.44 Thermal Values are 5/8 IGU w/ 1/8 366/Argon/ 1/8 Clear - No Muntins

5100 AWNING TEST RESULTS 5200 HOPPER TEST RESULTS U-Value w/loé 3 /Argon.49 Condensation Resistance 37 U-Value Air Only*.52 U-Value w/loé 3 /Argon.48 Condensation Resistance 39 U-Value Air Only*.51 Test Window 49 x 72 Vert. 2-Lite CW-PG60-AP.01 cfm/sq.ft. 9.00 psf 90.0 psf Sound Tranmission (w/ 1/4 LAM X 1/8 A) 36 Test Window 49 x 72 Vert. 2-Lite CW-PG60-AP.01 cfm/sq.ft. 9.00 psf 90.0 psf Sound Tranmission (w/ 1/4 LAM X 1/8 A) 36 Test Window 61 x 68 Vert. 2-Lite Sound Tranmission (w/ 1/4 LAM X 1/8 A) 36 CW-PG55-AP.01 cfm/sq.ft. Test Window 61 x 68 Vert. 2-Lite Sound Tranmission (w/ 1/4 LAM X 1/8 A) 36 CW-PG55-AP.01 cfm/sq.ft.

5300 CASEMENT TEST RESULTS 5800 DOUBLE HUNG TEST RESULTS U-Value w/loé 3 /Argon.48 Condensation Resistance 39 U-Value Air Only*.51 U-Value w/loé 3 /Argon.45 Visible Transmittance.46 Condensation Resistance 43 U-Value Air Only*.48 Test Window 105 x 72 CW-PG40-C.01 cfm/sq.ft. 9.00 psf 60.0 psf U-Value w/loé 3 /Argon.49 Condensation Resistance 38 Sound Tranmission (w/ 1/4 LAM X 1/8 A) 36 U-Value Air Only*.51 Test Window 93 x 60 CW-PG60-C.01 cfm/sq.ft. 9.0 psf 90.0 psf Sound Tranmission (w/ 1/4 LAM X 1/8 A) 36 Test Window 60 x 99 Indoor/Outdoor Sound Transmission Sound Tranmission (w/ 1/4 LAM X 1/8 A) Test Window 60 x 99 Indoor/Outdoor Sound Transmission Sound Tranmission (w/ 1/4 LAM X 1/8 A) LC-PG55-H.03 cfm/sq.ft. LC-PG55-H.03 cfm/sq.ft. Test Window 69 x 48 CW-PG90-C.01 cfm/sq.ft. 12.00 psf 135.0 psf Sound Tranmission (w/ 1/4 LAM X 1/8 A) 36

5400 PATIO DOOR TEST RESULTS 5500 FIXED TEST RESULTS U-Value w/loé 3 /Argon.37 1.32 2 Solar Heat Gain Coefficient.23 Visible Transmittance.53 Condensation Resistance 43 Test Window 5400 96x96 LC-PG40.06 cfm/sq.ft. 6.0 psf Sound Tranmission (w/ 1/4 LAM X 1/8 A) 34 Test Window 5400 72x80 LC-PG45.06 cfm/sq.ft. 6.9 psf U-Value w/loé3/argon.37 1.32 2 Solar Heat Gain Coefficient.23 Sound Tranmission (w/ 1/4 LAM X 1/8 A) 34 U-Value w/loé 3 /Argon.34 Visible Transmittance.55 Condensation Resistance 46 U-Value Air Only*.38 Test Window 72 x 72 and 48 X 96 CW-PG80-FW <.01 cfm/sq.ft. 12.00 psf 120.0 psf Indoor/Outdoor Sound Transmission 25 Sound Tranmission (w/ 1/4 LAM X 1/8 A) 33 AAMA Rating 1 w/loé 366 2 w/loé 366 and i89 Gerkin has tested a 96 x 96 and a 72 x 80 2-Lite door which meets AAMA rated Gold Label certification.

58F FIXED TEST RESULTS 58F FIXED TEST RESULTS U-Value w/loé 3 /Argon.33 Visible Transmittance.56 Condensation Resistance 59 U-Value Air Only*.37 Test Window 95 x 120 2-Lite With Stacking Mainframe Indoor/Outdoor Sound Transmission 27 Sound Transmission (w/ 1/4 LAM X 1/8 A) 34 Test Window 95 x 120 2-Lite With Stacking Mainframe Indoor/Outdoor Sound Transmission 27 Sound Transmission (w/ 1/4 LAM X 1/8 A) 34 CW-PG35-FW 0.01 cfm/sq.ft 0.02 cfm/sq.ft 52.5 psf LC-PG50-FW 0.01 cfm/sq.ft 0.02 cfm/sq.ft 75.0 psf Test Window 178 x 99 3-Lite With Stacking True Muntin Indoor/Outdoor Sound Transmission 27 Sound Transmission (w/ 1/4 LAM X 1/8 A) 34 Test Window 178 x 99 3-Lite With Stacking True Muntin Indoor/Outdoor Sound Transmission 27 Sound Transmission (w/ 1/4 LAM X 1/8 A) 34 LC-PG40-FW <.01 cfm/sq. ft..01 cfm/sq. ft. 60.0 psf LC-PG50-FW <.01 cfm/sq. ft..01 cfm/sq. ft. 75.0 psf U-Value/SHGC/VT/CRF Tested to NFRC 100/200/500 (With 1 Insulated Glass Unit With 1/8 366 And 1/8 Clear) Test Window 178 x 99 3-Lite With Stacking True Muntin Indoor/Outdoor Sound Transmission 27 Sound Transmission (w/ 1/4 LAM X 1/8 A) 34 CW-PG45-FW <.01 cfm/sq. ft..01 cfm/sq. ft. 67.5 psf