Converting slurry tailings facilities to filtered dry stacks a case history. John Lupo Newmont Mining Corporation Marcelo Mussé - Consultant

Similar documents
Filter-Pressed Dry Stacking: Design Considerations Based on Practical Experience

BAP or BAT? A review of some dramatic changes in tailings management in the recent past and potential changes in the future

Integrated Mine Waste Storage Concept, Krumovgrad Gold Project, Bulgaria

Material properties of Tailings from Swedish mines

Technical Memorandum. Minneapolis, MN Hibbing, MN Duluth, MN Ann Arbor, MI Jefferson City, MO

Muskeg River Mine Dedicated Disposal Area (DDA) Plan for In-pit Cell 1

Code No: RR Set No. 1

MOUNT POLLEY MINING CORPORATION MOUNT POLLEY MINE TAILINGS STORAGE FACILITY

Tailings dam raise with reinforced walls

Civil and Geotechnical Engineering

MOUNT POLLEY MINING CORPORATION MOUNT POLLEY MINE DESIGN OF THE TAILINGS STORAGE FACILITY TO ULTIMATE ELEVATION (REF. NO.

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

Mining Technology and Sustainable Development. Water and the Environment

SRK Consulting Sukulu Phosphate Project Scoping Report. 6 Tailings Dams Introduction Tailings behaviour...

Hydraulic performance of permanent heap leach with intermediate drainage system

Oil sands tailings dewatering can it be done?

2018 TAILINGS AND MINE WASTE CONFERENCE ALTERNATIVE APPROACHES TO MANAGEMENT FACILITIES AND CLOSURE OF TAILINGS STORAGE

LABORATORY EVALUATION OF CO-MIXED TAILINGS WASTE ROCK AND SLAG FOR THE CONSTRUCTION OF BARRIER COVER SYSTEMS AT COPPER CLIFF

Modified Centreline Construction of Tailings Embankn1ents

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 9/17/18)

Karara Iron Ore TSF design considerations for a unique large scale dry stack facility

Pore-Water Pressure Definition for a Levee Stability Analysis

Transient Seepage Analyses of Soil-Cement Uplift Pressures During Reservoir Drawdown

Tailings Storage and Heap Leaching in a Combined Facility A First for the Mining Industry

Tailings Facility Risk, Resilience, and Robustness

ASSESSMENT OF PASTE ROCK AS A COVER MATERIAL IN MINE RECLAMATION AT THE CANADIAN MALARTIC MINE

Dry Stacking Operation at Pogo Mine, Alaska June 12, Sumitomo Metal Mining Pogo LLC

Dirk J.A. van Zyl, Ph.D., P.Eng. P.E. Tailings and Mine Rock Management

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin

Design of Zinc Tailings Storage Facility

Redi Rock Specification and Installation Manual

LIFE Project Number LIFE03 ENV/GR/ Layman s Report

Thickened Tailings Deposition for Closure

Islamic University of Gaza Faculty of Engineering Civil Engineering Department Soil Mechanics Lab ECIV 3151 Final Exam 2016/2017

Importance of tailings properties for closure

SECTION MECHANICALLY STABILIZED EARTH RETAINING WALLS

Geotechnical behaviour of spent ore impacts of metallurgical factors

Understanding of foundation conditions, water balance adequacy and filter adequacy at the closed Nickel Plate tailings impoundment near Hedley, BC

C-R-S: PID: Reviewer: Date:

APPENDIX A.4A: Tailings Management Facility Construction Material Alternatives

A Framework for improving the ability to understand and predict the performance of heap leach piles

PRACTICAL COURSE III CLASSIFICATION & COMPACTION. Res. Assist. İREM KALIPCILAR

Design of the Eldorado Gold Efemçukuru Filtered Tailings Facility

0 Issued for Information RSG/ JAL/ JCP/

Geotechnical properties of zinc/lead mine tailings from Tara Mines, Ireland

Brooks/Cole Thomson LearningiM. Fundamentals of Geotechnical Engineering. Braja M. Das. California State University, Sacramento

2012 Soil Mechanics I and Exercises Final Examination

Licensing International Engineers into the Profession (LIEP)

Dewatered Tailings Management ARD Aspects. Todd Martin, P.Eng., P.Geo. AMEC Vancouver

Surface Disposal of Past Tailings at the Bulyanhulu Gold Mine, Tanzania

COMPACTED CLAY LINERS

0 Issued for Information JAJ/ JCP/ JCP/

CHAPTER 13 STRIP MINE RECLAMATION AND SOLID WASTE LANDFILL

Fly Ash Reservoir II Dam Initial Safety Factor Assessment. Cardinal Power Plant Brilliant, Ohio S&ME Project No A

Comparative Evaluation of Thickened versus Slurry Tailings Surface Disposal D. Johnson Golder Associates Ltd., Canada R. Moghaddam Golder Associates

Innovative Methods for Site Access and Insitu Testing of Impounded Ash Materials

In-pit tailings disposal at Langer Heinrich TSFs in a unique hydrogeological setting

B M CIVIL ENGINEERS 17/10/2016. CLIENT: Summit Group. JOB DESCRIPTION: Provide limited site investigation & site classification for the allotment.

CBC Aids WVDEP with Fresh Water Reservoir - Chief Logan State Park

Tailings Storage Facility Conceptual Closure Plan Alternatives Assessment

Report of CCR Rule Stability Analyses AEP Clifty Creek Power Plant Boiler Slag Pond Dam and Landfill Runoff Collection Pond

Factors affecting health of Ash Dyke and Preventive Measures. Kukreti RC Chowdhury Ujjwal Naresh D N

Enviable water recovery in a desert environment a case study

SITE INVESTIGATION. Foundation Engineering

Soil Compaction. Chapter (6) Instructor : Dr. Jehad Hamad

B M CIVIL ENGINEERS 19/10/2016. CLIENT: Summit Group. JOB DESCRIPTION: Provide limited site investigation & site classification for the allotment.

2.1 Backfill - General

June 30, 2015 Project No.: C Mr. Kent Christensen, P.Eng. General Manager Huckleberry Mines Limited PO Box 3000 Houston BC, V0J 1Z0

Stability problems of tailings dams

Mount Polley Mining Corporation IMPERIAL METALS CORPORATION

NICO Tailings and Mine Rock Co-disposal Facility (CDF) Design Concept

A Study on Seepage Through Earthen Dams By Using Analytical Methods 1 D.Ashok Kumar, 2 A. Mohan

Advances in Design of Landfills Over CCR Ponds and Landfills

Conceptual model for estimating water recovery in tailings impoundments

Atterberg limits Clay A Clay B. Liquid limit 44 % 55% Plastic limit 29% 35% Natural water content 30% 50%

Dewatering Fly Ash for Remediation: Two Approaches

Important Role of Filters in Hydraulic Soil Structures Hamid Fallah Apr. 19, 2013

GROUND IMPROVEMENT SITE INVESTIGATON

Assessment of Water Removal from Oil Sands Tailings by Evaporation and Under-drainage, and the Impact on Tailings Consolidation

Preview of LEAME Computer Software

Chapter 6. Soil Compaction

D5 Management of tailings and water storage facilities

D5 Management of tailings and water storage facilities

Construction of Embankment with Ground Improvement at By Pass of NH 34. Dilbag Singh Construction Head Transport Vertical HCC Ltd.

Design, Construction and Operation of a Large Centerline Tailing Storage Facility with High Rate of Rise

CHAPTER 5 CONCLUSIONS

VERTI-BLOCK - DESIGN MANUAL

SECTION SOILS REPORT

Study of the behavior of materials with fines content in heap leaching processes

OIL SANDS TAILINGS TECHNOLOGY: UNDERSTANDING THE IMPACT TO RECLAMATION. Melinda Mamer, P.Eng

TENCATE MIRAFI RSi MULTIFUNCTIONAL WOVEN GEOTEXTILES

(Refer Slide Time: 04:08)

Improvement Of Sandy Soil Properties By Using Bentonite

Dry Stacking of Cycloned Tailings

Cofra. CDC compaction. Cofra. Building worldwide on our strength

Ground Improvement of Titanium Dioxide Waste Spoils and Compressible Organics with In-Situ Mixing with Portland Cement and Surcharging

Independent Expert Engineering Investigation and Review Panel. Report on Mount Polley Tailings Storage Facility Breach. Appendix G: Water Balance

Expert Solution in BUILD ON US GEOTECHNICAL AND CIVIL ENGINEERING CONTRACTORS

Geoenvironmental impact assessment of a landfill for solid chemical wastes

Geotechnical design verification and performance assessment of tailings storage facilities

Transcription:

Converting slurry tailings facilities to filtered dry stacks a case history John Lupo Newmont Mining Corporation Marcelo Mussé - Consultant

Objectives General discussion on the geotechnical issues. Case history on a successful conversion. Lessons learned. Recommendations.

Purpose Water management Critical issue Consumption (mining industry) Efficient use Greater interest in using filtered dry stack tailings.

Filtered Dry Stack Tailings Lowest amount of water consumption. Generally easier to handle and often can be stacked, thereby reducing storage space requirements, construction costs and, often, permitting costs. Often can support concurrent reclamation. Can have high up-front capital cost and operating costs. These costs need to be offset by the value of water in a cost-benefit analysis.

Existing Slurry Impoundments Existing slurry tailings impoundments often targeted for filtered tailings storage: May reduce overall capital cost (no or limited construction required for storage) Impoundment area already permitted Real-estate for construction of a new facility often not available However slurry impoundments are designed with a different intent that can complicate conversion.

Conversion Considerations Slurry impoundments generally designed for no or limited access into the impoundment. Access and tracking with heavy equipment a requirement for placement and stacking of filtered tails. The ability to access and track over the slurried tailings surface is a function of the tailings mechanical and hydraulic properties, drainage conditions within the impoundment, depositional history/management and time.

Impoundment Characterisation Prior to considering conversion, some level of characterisation (geotechnical, hydrogeologic, and geochemical) must be done. The level of characterisation is dependent on the site conditions, tailings properties, impoundment design basis and uncertainty. Characterisation could range from very extensive to minor.

Some Important Bits.. Conversion from slurry to filtered dry stack changes the geotechnical, hydraulic and geochemical environment within the impoundment. For example: Air flow will now occur within the tailings mass Stacking tailings introduces new failure mechanisms not considered in original design or risk assessment While filtered tailings are generally unsaturated, local zones of saturation will develop.. Are these changes and risk well understood and are they acceptable for the short and long-term performance of the facility?

Case Study

Background 1 of 2 3 ktonne/ day operation in Mexico, in operation for several years. Existing slurry tailings impoundment, fully lined (HDPE) to minimize seepage and water loss. Robust main containment embankment constructed of engineer fill. Deposition by spigotting with some cycloning. Tailings facility nearing maximum capacity.

Background 2 of 2 Limited real-estate near the operation for expanding the existing tailings impoundment. Alternative sites not viable (both from cost and permit time schedule basis). Dwindling water supply.

View of slurried tailings impoundment, looking upstream toward main containment embankment Slurried tailings deposition by spigotting and cycloning Reclaim pool Old tailings storage cell

Characterisation Work Geochemical characterisation completed by others. No geochemical issues identified. Geotechnical: Borings and test pits (limited due to soft beach and availability of equipment). Laboratory: particle size distribution, moisture-density, and shear strength. Process: Bench scale vacuum and mechanical filtration tests.

Tailings Grain Size PSD shows 65 to 70 percent passing 0.075 mm

A Few Points on Shear Strength. Shear strength testing is not a one program fits all. The program should be tailored toward the anticipated loading of each distinct project. In addition, shear strength is just one component of the design approach. What is as important as shear strength is the stress path and volume behavior of the material (e.g. dilatant versus contractive behavior).

For this project. The main containment embankment is a very robust design and stability under the worst loading conditions was not an issue. No additional shear testing (beyond the original work) was conducted on these materials In-place tailings in variable states of density, so individual tests may have little meaning. Another approach would be needed.

Filtered Tailings Filtered tailings would be produced at a more uniform density and moisture content. Consolidated drained tests conducted at the maximum dry density and optimum moisture content. These tests showed a positive volume change with shear, indicating dilatant behavior (phi = 33 degrees and zero cohesion).

Drained vs Undrained Why test the filtered tailings under drained conditions and not undrained? Observations from site suggest that the tailings are well draining, even with 65-70% fines. Given the low processing rate and desire to maintain a low stacking height, development of saturation and excess pore pressures in stack unlikely. Out-of-spec tailings (e.g. wet or near saturated tailings) from filter plant would not be placed in stack, per the design.

Filtration Tests Description Cake dry density (kg/m3) Cake moisture content (% by weight) Mechanical press 1,715 14 to 16 % Vacuum belt 1,498 21 to 25% Note: Moisture-Density tests indicate the filtered tailings have maximum dry density of 1,756 kg/m3 and an optimum moisture content of 12% by weight.

Filtered Tailings Exit filter presses at or near the maximum dry density (Standard Proctor). Moisture content a few points above optimum. Filtration produces a material that is preconsolidated, dense state. Reflected in shear as dilatant behavior. Important for liquefaction and seismic stability evaluations.

Design Concept

Schematic of Facility Prior to Conversion 3H:1V Slope HDPE Liner Reclaim Pool Slime Tailings 8 m crest 3H:1V Slope Sandy Tailings Main Containment Embankment

Schematic of Converted Facility Place out-of-spec tailings basin formed by filtered tailings and natural ground. Design dry stack with maximum 2m lifts to minimise loading and potential for bearing failure. Filtered tailings compacted to maximum dry density and at optimum moisture content. Rock drainage layer placed to assist in drainage and stability. Construct a 3 m thick platform providing a 10 m setback to stabilise toe of dry stack to provide stability and confinement. Filtered Tailings Dry Stack Slime Tailings HDPE Liner Placement of filtered tailings over soft slimes could result in local bearing failure. Adopt an observational approach to material placement. Sandy Tailings Main Containment Embankment

Filtered Tailings Lift Concept Extraction wells provided to help reduce phreatic surface within impoundment.

Concept The design concept relies on the ability to stack filtered tailings over the existing slurried tailings surface. As part of the conversion, the area nearest the main embankment needs to be drained and dried to the extent possible. On site experience indicated that the dried beach nearest the embankment could be trafficked by 40t trucks.

Test Fill Although observations suggested that the dried surface could be trafficked, there was uncertainty on the bearing capacity under a fill. Test fill was used to test the concept that the variable tailings could support a modest load from fill. Test fill: 30 m x 50 m by 5 m thick fill placed and compacted. Test fill showed some local signs of displacement (mud wave), but overall was stable.

View of Platform Construction

View of Filtered Dry Stack Tailings 4 Years Later Inactive tailings impoundment now covered by filtered tailings Old slimes and out-of-spec material area Location of old reclaim pool Compacted filtered tailings Main embankment Uncompacted filtered tailings

Conclusions The filtered dry stack concept presented has worked well for over 4 years. Facility was converted to dry stacking without an interruption of the operation. The facility is being constructed following the original design concept with some minor changes (lesson learned). Water levels within the impoundment have dropped consistently and no longer causing issues with material placement.

Lessons Learned 1 of 2 Safety is the number one issue. A safety plan with daily safety briefings were used to maintain a high level of diligence within the work force. Not everything goes to plan, a key issue was getting as much water off the surface as soon as possible to allow some surface drying to occur. In a few areas, this was not achieved. As a result, some local bearing failures did develop. The remediation for these areas included placing a thicker rock drainage layer over the surface to help support the placement of tailings.

Lessons Learned 2 of 2 The success of this conversion is due primarily to having a high level of construction quality assurance on-site, full time. This level of observation help minimise issues that may have compromised the performance of the facility as well as increase the safety of the workers on the facility.

THANKS