Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze) Removable Nylon Screens w/ aluminum frame (in white or brown) Drawing: 1 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x 16 (6x6)
FOUNDATION DIMENSIONS SIZE & DIMENSIONS N M Q Q Key: Based on hipped roof type 16' x 16' A: Height, Overall 185" B: Height, Grade/peak 165" C: Height, Entrance 80 1/4" D: Height, Top of Cross Rail 34" E: Width, Door Entrance 38" F: Width, Interior (long side) 187" G: Width, Interior (short side) 187" H: Height of Wall Panel 101" Foundation Key: M: Width, Point to Point 202 1/2" N: Width, Flat to Flat 202 1/2" Q: Spread, Post Centers 48" A B F G H E C D Drawing: 2 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x 16 (6x6)
DITMAR BEAM 'TOP VIEW 6x6 Post (4 9/16 x 4 9/16 ) Post Tenon ( 3 1/2 high) Post Groove ( 1 3/16 x 1 9/16 ) WALL PANEL, POST & DITMAR BEAM CONSTRUCTION 2 X 6 (1 1/2 x 5 1/2) 2x6 ( 5 1/4 ) 11 1/2" 2 X 3 2 X 6 (1 1/2 x 5 1/2) Panel Thickness 1 1/2 (incl. removable nylon screens w/ aluminum frame in brown or white) 5/8 HOLE for 5 5/8 x 1/2 SS ROD 2 X 6 (1 1/2 x 5 1/2) 2x6 ( 5 1/4 ) 6" Structural Screws 47 1/4" 100 3/4" (not incl. threshold) 6 X 6 ( 4 9/16 sq.) Tempered Glass (2) 4" Screws (hole 3 on left & 2 on right side) to fasten post & panel 2x6 ( 5 1/4 ) 24 1/2" Threshold THRESHOLD Spline (insert into bottom of panel) 3/4 3 45 3/4" Drawing: 3 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x16 (6x6)
2x6 ( 5 1/4 ) DOUBLE DOOR CONSTRUCTION 11 1/2" 2x6 ( 4 1/2 ) Strap Hinges (3/4 offset) and pintels (1 1/4 offset) from wrought steel w/black powder coating (top & bottom length 18 middle length 12 ) 80 1/2" Entrance opening (not incl. threshold) 2x6 ( 5 1/4 ) Entry Key Lock Set (brass plated) available in dark bronze or bright brass (2) 4" Screws (hole 3 on left & 2 on right panel side) Slide Bolt ( solid bright brass) mounted on the inside on top & bottom of left door THRESHOLD 3/4 2x6 ( 4 1/2 ) 19 1/2" 38 1/4" 45 3/4" Threshold 3 Drawing: 4 of 9 Created by: Andrea Beringer Date: May 2013 Model: Cabana Hip Roof
Electrical Light Fixture (max. 500W) Grooved Riser Additional Options: Outlet posts (dual) Fan Control post (fan/light) Channel Posts (for custom wiring) 14-2 UF/B with ground Hidden Wire through Channeled Post Electric Outlet w/switch & receptacle (GFI) Note: For concrete slab use conduit through void (see slab instructions) Drawing: 5 of 9 Created by: Andrea Beringer Date: May 2013 Model: CABANA
THE CUPOLA IS CONNECTED WITH STAINLESS STEEL SCREW FROM THE UNDER SIDE OF THE ROOF LATH. CEDAR SHINGLE OR 16 OZ. COPPER 30" ROOF CONSTRUCTION 26" 2X6 TOP SOFFIT 9" #10 X 2" SCREWS (4 PER LATH) 5/4" X 4" ROOF LATH 1 3/4 SPACING 2X6 HIP JOIST 5/4" X 7/16" STAINLESS STEEL STAPLES 2X6 CENTER JOIST 2X6 SUPPORT JOIST 160 5" SHINGLE REVEAL 122 1 1/2 X 4 1/2 FACIA BOARD 107 Drawing: 6 of 9 Created by: Andrea Beringer Date: May 2013 Model: Cabana Hip Roof
ROOF / POST / DITMAR BEAM CONNECTION ROOF LATH 2X6 HIP JOIST 5/8 HOLE for 5 5/8 x 1/2 SS ROD 2X6 TOP SOFFIT HIP-ROOF ATTACHMENT (6x6Constr.) 6 1/2 T/G CEDAR (slide into groove on the bottom of facial pc. & ditmar beam) 2X4 FACIA BOARD 2X6 DITMAR BEAM 5 1/2 HIP JOIST DITMAR BEAM 4 1/4 FACIA BOARD 6 1/2 T/G 1/2 4 x 5/8 HOLES APPROX. 20 APART FOR 1/2 SS RODS 6x6 POST WALL PANEL STYLE TENON 3 1/2 high POST GROOVE 1 3/16 deep 1 9/16 wide ROOF SYSTEM RIDGED TRIANGULAR MODULES CONNECT TO FORM A CONIC ROOF SYSTEM. THE COMPRESSION RING IS INTEGRAL TO THE CONIC DESIGN AND ALLOWS RESULTANT FORCES TO BE PERPENDICULAR TO GRADE. Drawing: 7 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x16 (6x6)
2" DIAMETER HOLE 4" DEEP 202 1/2 SLAB DIMENSIONS ANCHORING HARDWARE DIMENSIONS 3 Anchor Pin 202 1/2 48" 6 long ( 3 1/2 into Hydrolytic Grout 2 1/2 inside post ) 6 SS Angled Anchor 1/8 thick, 1 1/2 wide, with 1/2 Bend 48" POST ANCHORING ON CONCRETE SLAB Post Base 4 9/16 x 4 9/16 3 Anchor Pin SS Angle Anchor Tab 3 1/2" Reveal Electrical Post: Pre-wired post has to be placed at power feed! 2 Core Drill Void CONCRETE SLAB Drawing: 8 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x16 (6x6)
Specifications for the CABINET models (8 x 12, 12 x 12, 12 x 16 & 16 x 16 ) Part 1 General 1.1 Scope. The contractor shall furnish and install a wooden gazebo as shown on plans and herein specified as supplied by Vixen Hill Mfg. Co. Inc., of Elverson, PA 19520. Part 2 Product 2.1 Wood Materials. For CABINET Grade shall be fabricated from Air-Dried, #1 old growth & rot resistant western red cedar. All wood shall be grain selected during in-house milling for best application and safe use. 2.2 Roofing System. Shingles shall be of or equal to #1 perfection clear heart cedar and per the following specifications 5X, 16" long, 1/2" thick, tapered. Roof lath shall be of no less than net finished size 1x3 with a 5 spacing. Roof sections shall be mostly pre-assembled and completely pre-cut, and joints between roof sections shall be self-sealing to preclude capping. Caulk is recommended to be used at the roof joist. 2.3 Surface Finish. All wood members shall be surfaced four sides. Surfaces displaying planer skips or saw marks after dressing shall be limited to less than 25% of shown faces. Hand contact edges may be rounded, chamfered, or edge-shaped free of splinters and smooth to the touch. All exposed surfaces shall be prepared for maximum acceptance of oil-based finishes (optional with additional cost). 2.4 Hardware. All assembly & Anchoring hardware shall be provided. Concealed Roto-Locks are built into the wall panel. The threaded rods for the panel capping pieces are of galvanized steel with stainless steel cap nuts & washers and of a finish type to conceal all threads. All hardware in ground contact shall be of stainless steel for CABINET grade. No nails shall be required or provided. The strap hinges for the door(s) are mode from zinc-plated & powder-coated steel with a flat and smooth finish. 2.5 Electrical. Standard for CABINET grade. The pre-wired post provides 110V electrical service through wire (14-2 UF/B with ground).the post has an electrical box with (GFI) receptacle and light switch. The light fixture is screwed inside the cupola for up to 500W strength. Wires shall be hidden within the component parts through grooved roof section and channeled post. All electrical components shall be UL approved. 2.6 Connections & Anchoring. Factory module construction shall include pocket joints and stainless steel threaded fasteners. On-site interconnection of modules shall be achieved using threaded rods and stainless or brass cap nuts and washers. Anchoring shall be concealed and appropriate to the surface mounting material. The larger modules require 1/3 of the shingles to be applied after the roof modules are joint together, as well as other minor carpentry work. 2.7 Engineering. Design of connections and materials used shall be such as to adhere to structural requirements of major building codes. Drawings and representative engineering shall be available from the manufacturer for the purpose of permits or architectural review. Part 3 Execution 3.1 Prefabrication. All component parts shall be pre-assembled to the fullest extent possible, to preclude any on-site drilling, cutting, filling, nailing or sanding. All prefabrication fasteners shall be hidden from view or channeled and stripped with matching wood where visible. 3.2 Installation. The gazebo kit shall be supplied with all necessary hardware, shop drawings and complete instructions to provide for efficient on-site assembly. Some Carpentry Skills required, call us for assistance and/or installation service. Drawing: 8 of 9 Created by: Andrea Beringer Date: May 2013 Model: CA