Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Similar documents
Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION NON-STRUCTURAL METAL FRAMING

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

SECTION TIMBER FLOATS

NatureScape. 3 Thermally Broken 2 Non-thermal

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

Flextray - Accessories

The better way to build TM. Installation Manual NAILBASE PANELS

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECTION METAL ATHLETIC LOCKERS

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION DETENTION WINDOW SCREENS. 1. Detention screens for interior and exterior installations at exterior windows in existing buildings.

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

SECTION METAL EQUIPMENT LOCKERS

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change.

1 3 4 Tie Rod Aluminum Swing Entrance Doors

PATHWAYS FOR COMMUNICATIONS SYSTEMS

Trex Commercial Products page Metal Railing

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION CHAIN LINK FENCING

SECTION ALUMINUM HANDRAIL SYSTEMS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

SECTION TOILET PARTITIONS. A. Section Structural Steel: Supports for ceiling hung compartments.

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

Division 11 - Equipment Section 11401

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION SUPPORTS AND ANCHORS

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

Suggested Materials and Tools:

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION ORNAMENTAL WELDED STEEL FENCING

Preassembled steel stairs with concrete-filled treads.

SECTION METAL ATHLETIC LOCKERS

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science

C.R. LAURENCE CO., INC. Intelli-Track SPS. Phase One - Installation Instructions

SECTION CHAIN LINK FENCES AND GATES (PARK)

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

SECTION DECORATIVE METAL AND GLASS RAILING

DETENTION / SECURITY WINDOWS SECTION 08660

Homeowners complain about having too much storage space about as often as they do about having an overabundance of cash. It just doesn't happen.

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

Interior Hangers. Application

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

Detailed Deck Building

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

HOTEL SPECIFICATION SECTION 08100

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

POST FRAME BUILDING STANDARDS

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

University Apartments on Brooklyn PROJECT MANUAL

A. Access doors and frames are part of an access door and frame allowance.

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

10155 Toilet Compartments

RULON LINEAR OPEN SUSPENDED WOOD CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

Building permits are not required for patios made of concrete or pavers on grade.

Section 5 Panels & Accessories

KS SERIES - VERTICAL INSTALLATION

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

Rytec Corporation One Cedar Parkway Jackson, WI GO-RYTEC (262)

Sheet Metal Flashing and Trim

SECTION PLATE CONNECTED WOOD TRUSSES

SPECIFICATIONS...02-M3 TECHNICAL DATA...03-M3 TYPICAL DETAILS...04-M3 and 05-M3

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION DIRECTORIES

SECTION SECTIONAL OVERHEAD DOORS

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

Daytona Beach Pier Building Renovation Jun 2010

FitTech UP166F CHEST PRESS (FOOTING) UP166I CHEST PREES (IN GROUND) UP166S CHEST PRESS (SURFACE)

SECTION STANDPIPE AND HOSE SYSTEMS

HALLOWELL FORT KNOX Modular Utility Storage and Workbench System Specifications

Series - 1

SECTION DECORATIVE METAL FENCES AND GATES

SECTION OVERHEAD COILING SHUTTERS

SECTION 1043 FENCE MATERIAL

Transcription:

Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze) Removable Nylon Screens w/ aluminum frame (in white or brown) Drawing: 1 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x 16 (6x6)

FOUNDATION DIMENSIONS SIZE & DIMENSIONS N M Q Q Key: Based on hipped roof type 16' x 16' A: Height, Overall 185" B: Height, Grade/peak 165" C: Height, Entrance 80 1/4" D: Height, Top of Cross Rail 34" E: Width, Door Entrance 38" F: Width, Interior (long side) 187" G: Width, Interior (short side) 187" H: Height of Wall Panel 101" Foundation Key: M: Width, Point to Point 202 1/2" N: Width, Flat to Flat 202 1/2" Q: Spread, Post Centers 48" A B F G H E C D Drawing: 2 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x 16 (6x6)

DITMAR BEAM 'TOP VIEW 6x6 Post (4 9/16 x 4 9/16 ) Post Tenon ( 3 1/2 high) Post Groove ( 1 3/16 x 1 9/16 ) WALL PANEL, POST & DITMAR BEAM CONSTRUCTION 2 X 6 (1 1/2 x 5 1/2) 2x6 ( 5 1/4 ) 11 1/2" 2 X 3 2 X 6 (1 1/2 x 5 1/2) Panel Thickness 1 1/2 (incl. removable nylon screens w/ aluminum frame in brown or white) 5/8 HOLE for 5 5/8 x 1/2 SS ROD 2 X 6 (1 1/2 x 5 1/2) 2x6 ( 5 1/4 ) 6" Structural Screws 47 1/4" 100 3/4" (not incl. threshold) 6 X 6 ( 4 9/16 sq.) Tempered Glass (2) 4" Screws (hole 3 on left & 2 on right side) to fasten post & panel 2x6 ( 5 1/4 ) 24 1/2" Threshold THRESHOLD Spline (insert into bottom of panel) 3/4 3 45 3/4" Drawing: 3 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x16 (6x6)

2x6 ( 5 1/4 ) DOUBLE DOOR CONSTRUCTION 11 1/2" 2x6 ( 4 1/2 ) Strap Hinges (3/4 offset) and pintels (1 1/4 offset) from wrought steel w/black powder coating (top & bottom length 18 middle length 12 ) 80 1/2" Entrance opening (not incl. threshold) 2x6 ( 5 1/4 ) Entry Key Lock Set (brass plated) available in dark bronze or bright brass (2) 4" Screws (hole 3 on left & 2 on right panel side) Slide Bolt ( solid bright brass) mounted on the inside on top & bottom of left door THRESHOLD 3/4 2x6 ( 4 1/2 ) 19 1/2" 38 1/4" 45 3/4" Threshold 3 Drawing: 4 of 9 Created by: Andrea Beringer Date: May 2013 Model: Cabana Hip Roof

Electrical Light Fixture (max. 500W) Grooved Riser Additional Options: Outlet posts (dual) Fan Control post (fan/light) Channel Posts (for custom wiring) 14-2 UF/B with ground Hidden Wire through Channeled Post Electric Outlet w/switch & receptacle (GFI) Note: For concrete slab use conduit through void (see slab instructions) Drawing: 5 of 9 Created by: Andrea Beringer Date: May 2013 Model: CABANA

THE CUPOLA IS CONNECTED WITH STAINLESS STEEL SCREW FROM THE UNDER SIDE OF THE ROOF LATH. CEDAR SHINGLE OR 16 OZ. COPPER 30" ROOF CONSTRUCTION 26" 2X6 TOP SOFFIT 9" #10 X 2" SCREWS (4 PER LATH) 5/4" X 4" ROOF LATH 1 3/4 SPACING 2X6 HIP JOIST 5/4" X 7/16" STAINLESS STEEL STAPLES 2X6 CENTER JOIST 2X6 SUPPORT JOIST 160 5" SHINGLE REVEAL 122 1 1/2 X 4 1/2 FACIA BOARD 107 Drawing: 6 of 9 Created by: Andrea Beringer Date: May 2013 Model: Cabana Hip Roof

ROOF / POST / DITMAR BEAM CONNECTION ROOF LATH 2X6 HIP JOIST 5/8 HOLE for 5 5/8 x 1/2 SS ROD 2X6 TOP SOFFIT HIP-ROOF ATTACHMENT (6x6Constr.) 6 1/2 T/G CEDAR (slide into groove on the bottom of facial pc. & ditmar beam) 2X4 FACIA BOARD 2X6 DITMAR BEAM 5 1/2 HIP JOIST DITMAR BEAM 4 1/4 FACIA BOARD 6 1/2 T/G 1/2 4 x 5/8 HOLES APPROX. 20 APART FOR 1/2 SS RODS 6x6 POST WALL PANEL STYLE TENON 3 1/2 high POST GROOVE 1 3/16 deep 1 9/16 wide ROOF SYSTEM RIDGED TRIANGULAR MODULES CONNECT TO FORM A CONIC ROOF SYSTEM. THE COMPRESSION RING IS INTEGRAL TO THE CONIC DESIGN AND ALLOWS RESULTANT FORCES TO BE PERPENDICULAR TO GRADE. Drawing: 7 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x16 (6x6)

2" DIAMETER HOLE 4" DEEP 202 1/2 SLAB DIMENSIONS ANCHORING HARDWARE DIMENSIONS 3 Anchor Pin 202 1/2 48" 6 long ( 3 1/2 into Hydrolytic Grout 2 1/2 inside post ) 6 SS Angled Anchor 1/8 thick, 1 1/2 wide, with 1/2 Bend 48" POST ANCHORING ON CONCRETE SLAB Post Base 4 9/16 x 4 9/16 3 Anchor Pin SS Angle Anchor Tab 3 1/2" Reveal Electrical Post: Pre-wired post has to be placed at power feed! 2 Core Drill Void CONCRETE SLAB Drawing: 8 of 9 Created by: Andrea Beringer Date: May 2013 Model: 16 x16 (6x6)

Specifications for the CABINET models (8 x 12, 12 x 12, 12 x 16 & 16 x 16 ) Part 1 General 1.1 Scope. The contractor shall furnish and install a wooden gazebo as shown on plans and herein specified as supplied by Vixen Hill Mfg. Co. Inc., of Elverson, PA 19520. Part 2 Product 2.1 Wood Materials. For CABINET Grade shall be fabricated from Air-Dried, #1 old growth & rot resistant western red cedar. All wood shall be grain selected during in-house milling for best application and safe use. 2.2 Roofing System. Shingles shall be of or equal to #1 perfection clear heart cedar and per the following specifications 5X, 16" long, 1/2" thick, tapered. Roof lath shall be of no less than net finished size 1x3 with a 5 spacing. Roof sections shall be mostly pre-assembled and completely pre-cut, and joints between roof sections shall be self-sealing to preclude capping. Caulk is recommended to be used at the roof joist. 2.3 Surface Finish. All wood members shall be surfaced four sides. Surfaces displaying planer skips or saw marks after dressing shall be limited to less than 25% of shown faces. Hand contact edges may be rounded, chamfered, or edge-shaped free of splinters and smooth to the touch. All exposed surfaces shall be prepared for maximum acceptance of oil-based finishes (optional with additional cost). 2.4 Hardware. All assembly & Anchoring hardware shall be provided. Concealed Roto-Locks are built into the wall panel. The threaded rods for the panel capping pieces are of galvanized steel with stainless steel cap nuts & washers and of a finish type to conceal all threads. All hardware in ground contact shall be of stainless steel for CABINET grade. No nails shall be required or provided. The strap hinges for the door(s) are mode from zinc-plated & powder-coated steel with a flat and smooth finish. 2.5 Electrical. Standard for CABINET grade. The pre-wired post provides 110V electrical service through wire (14-2 UF/B with ground).the post has an electrical box with (GFI) receptacle and light switch. The light fixture is screwed inside the cupola for up to 500W strength. Wires shall be hidden within the component parts through grooved roof section and channeled post. All electrical components shall be UL approved. 2.6 Connections & Anchoring. Factory module construction shall include pocket joints and stainless steel threaded fasteners. On-site interconnection of modules shall be achieved using threaded rods and stainless or brass cap nuts and washers. Anchoring shall be concealed and appropriate to the surface mounting material. The larger modules require 1/3 of the shingles to be applied after the roof modules are joint together, as well as other minor carpentry work. 2.7 Engineering. Design of connections and materials used shall be such as to adhere to structural requirements of major building codes. Drawings and representative engineering shall be available from the manufacturer for the purpose of permits or architectural review. Part 3 Execution 3.1 Prefabrication. All component parts shall be pre-assembled to the fullest extent possible, to preclude any on-site drilling, cutting, filling, nailing or sanding. All prefabrication fasteners shall be hidden from view or channeled and stripped with matching wood where visible. 3.2 Installation. The gazebo kit shall be supplied with all necessary hardware, shop drawings and complete instructions to provide for efficient on-site assembly. Some Carpentry Skills required, call us for assistance and/or installation service. Drawing: 8 of 9 Created by: Andrea Beringer Date: May 2013 Model: CA