CABANA BEACH CLUB ARCHITECT JAA ARCHITECTURE 2716 ST. JOHNS AVE JACKSONVILLE, FLORIDA (904) CONTACTS: JOHN ALLMAND JASON TANKERSLEY

Similar documents
5. Project Construction Cost (Provide cost for new construction, the addition or the alteration): $ Estimated Project Budget is $125,000.

2. Does not require, involve or include any additions to, or repair or modification of, the existing foundation.

School Construction Authority Architecture & Engineering

IR 11B-10 SCOPING AND PATH OF TRAVEL UPGRADE REQUIREMENTS FOR FACILITY ALTERATION, ADDITION A ND STRUCTURAL REPAIR PROJECTS

ACCESSIBILITY CHECKLIST

Accessibility Update: Requirements for Existing Buildings (2 hours)

Access Upgrade Compliance Package (For Existing Commercial Buildings only)

Americans with Disabilities Act Accessibility Survey

ADA Standards for Accessible Designs: 6 PDH Course# ADA106. EZpdh.com All Rights Reserved

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

Site Accessibility Survey & Transition Plan

Alterations, disproportionality, and the 20% rule

PRESCRIPTIVE COMPLIANCE METHOD

Florida Accessibility Code for Building Construction

Successful Restaurant. Accessibility. Accessibility. Did you sign in? Best Practices. Copyright Materials. Course Description

SUPPLEMENTAL ACCESSIBILITY NO. 5 PLAN REVIEW CHECKLIST

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

Commercial Remodel Permit

Plan Check No. A. ELEVATORS

BUILDING BLOCKS DRAFT

PRESCRIPTIVE COMPLIANCE METHOD

CTC to BCAC IBC/ADA Coordination/ IEBC 3-2, 4-1 thru 4-8a, 7-1 thru 7-3, 8-1, 12-1, 14-1 and 15-1

2015 IBC Accessible Means of Egress

SINGLE FAMILY REGULATIONS UNDERSTORY AREAS ORDINANCE NO.

Design Aid for Barrier-Free Accessibility in Existing Buildings

Florida Accessibility Code for Building Construction

A minimum of 25% of any money spent upgrading areas of primary function shall be devoted to ADA upgrades. Existing non-compliant areas include:

CHAPTER 1: APPLICATION AND ADMINISTRATION

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

The Building Codes A.R.E. Building Design and Construction Exam Prep

700 E. Johnson St. Madison, WI A0.1 MIXED USE BUILDING. 700 E. Johnson St. Madison, WI VICINTY MAP SCALE: NONE DRAWING INDEX GENERAL NOTES

Waiver# 187-R0. Requirements to be Waived.

CHAPTER 62B-34 GENERAL PERMITS FOR ACTIVITIES SEAWARD OF THE COASTAL CONSTRUCTION CONTROL LINE

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

Building Code 8 th Edition

ADA Standards for Accessibility. Glenn Hill

B-2 COMMUNITY COMMERCIAL BUSINESS DISTRICT. Uses allowed in the B-2 Community Commercial Business District are subject to the following conditions:

2015 International Existing Building Code Overview Based on the International Existing Building Code (IEBC )

HALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE

CHAPTER 34 EXISTING BUILDINGS

2007 Title 24 Accessibility Code Updates and ADA Issues

PLANNING BOARD HEARING Miami Shores Village Town Hall Council Chambers NE 2 nd Avenue Miami Shores Hearing Date April 24, 2014

Storm Damage Repair Requirements

HOUSING CONVERSION Guidelines for the conversion of a house to commercial use.

2015 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

COMMERCIAL BUILDING HANDBOOK 2015 International Building Code (IBC)

CITY OF DANA POINT WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS

PERMIT APPLICATION REQUIREMENTS NEW SINGLE FAMILY DWELLING

ARTICLE III. TECHNICAL CODES AND OTHER CONSTRUCTION STANDARDS* Sec Adoption of the Florida Building Code and Countywide Amendments.

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

2015 IBC Exit Systems

Showing Only Sections Changed 6 th Edition FBC (2017) from 5 th Edition FBC (2015) [changes shown with underline and strike-through]

STATE UNIVERSITY CONSTRUCTION FUND

DISABLED ACCESS UPGRADE COMPLIANCE CHECKLIST PACKAGE (For Existing Buildings only)

Save the Places that Matter. Build Community. Live Better. Building Code Officials Are Part of Your Revitalization Team

PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST

MONTEREY COUNTY PLANNING & BUILDING INSPECTION DEPARTMENT st AVENUE MARINA, CA (831) FAX: (831)

CHAPTER 34 EXISTING STRUCTURES. Note: Chapter 34 is entirely Seattle amendments to the International Building Code and is not underlined.

CTC Meeting #28 September 16-17, 2013 IBC Coordination with ADAAG

OREGON STATE UNIVERSITY Memorial Union Access Improvement Study. October 21, 2013

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS ICC

2012 TAS. Did you sign-in? Atelier. the first year. Course Description. Latest with TDLR. Learning Objectives TAS The First Year April 2013

NEW HAMPSHIRE CODE OF ADMINISTRATIVE RULES

NYC Department of Education

Adult Family Home Inspections

City of San Pablo Community Development Department Building Inspection Division Plan Review & Permit Requirements

ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

9th Edition Residential Volume with MA Amendments - Flood Standards Only DRAFT. 9th Edition Massachusetts Residential Code Requirements in Floodplains

Access Update Newsletter

Administrative Changes

COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS

NYC Department of Education

Elevation Certificate Checklist

SUPPLEMENTAL ACCESSIBILITY NO. 4 PLAN REVIEW CHECKLIST

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

Request for a Waiver From the Requirements of Vertical Accessibility From the FACBC

Minimum Requirements for Residential Occupancy Codes and FAQs

BUILDING PERMIT APPLICATION

COLUMBIA COUNTY LAND DEVELOPMENT SERVICES COURTHOUSE ST. HELENS, OREGON PHONE (503) CODE SUMMARY REQUIREMENTS

Exterior Elevated Elements Inspection Guidelines

SIDEWALK & RAILING REPLACEMENT BOARD OF ED BUILDING

Flood Resistant Provisions in the 6 th Edition Florida Building Code (2017)

International Building Code 2009

City Commission Workshop

1530 Grizzly Peak Blvd. Lot 598

The following information is required when submitting a building permit application:

Chapter 11. Dwelling Units and Sleeping Units

NYC Department of Education

Facilities Feasibility Study Frederick Douglass HS Condition Assessment

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

PLANS REVIEW CRITERIA - COMMERCIAL BUILDINGS

NYC Department of Education

INTERNATIONAL EXISTING BUILDING CODE

Commercial and Residential Projects (after appropriate Board approvals have been made if necessary):

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

ARTICLE 987. PD 987. PD 987 was established by Ordinance No , passed by the Dallas City Council on June 14, (Ord.

Transcription:

CABANA BEACH CLUB OF THE SAWGRASS MARRIOTT HOTEL 609 PONTE VEDRA BLVD, PONTE VEDRA BEACH, ST. JOHNS COUNTY, FLORIDA 32082 ADA WAIVER ON VERTICAL ACCESSIBILITY FOR AN EXISTING BEACHSIDE RESTAURANT OWNER WATERMARK CAPTIAL PARTNERS, LLC 272 E DEERPATH RD, SUITE 320 LAKE FOREST, ILLINOIS 60045 (847) 582.9984 CONTACTS: GEORGE GUDGEON LORCAN DREW CLIENT CABANA BEACH CLUB via SAWGRASS MARRIOTT HOTEL 619 PONTE VEDRA BLVD PONTE VEDRA BEACH, FLORIDA 32082 (904) 285.7777 CONTACT: TOM AYRES CONSTRUCTION MANAGEMENT THE JOHN HARDY GROUP 6085 BARFIELD RD NE, SUITE 200 SANDY SPRINGS, GEORGIA 30328 (404) 256.8805 CONTACT: NATHAN ASSAY ARCHITECT JAA ARCHITECTURE 2716 ST. JOHNS AVE JACKSONVILLE, FLORIDA 32205 (904) 379.5108 CONTACTS: JOHN ALLMAND JASON TANKERSLEY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

TABLE OF CONTENTS INTRODUCTION...3-4 OPENING STATEMENT...5 ARGUEMENT A - STATEMENT & SECTION... 6 ARGUEMENT A - SITE PLAN... 7 ARGUEMENT A - SCOPE OF WORK & COST...8-9 ARGUEMENT A - SUMMARY... 10 ARGUEMENT B - STATEMENT & SECTION... 11 ARGUEMENT B - SITE PLAN... 12 ARGUEMENT B - SCOPE OF WORK & COST...13-14 ARGUEMENT B - SUMMARY... 15 CLOING STATEMENT...16 INDEX, CODE REFERENCES, EXHIBIT LIST... 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

INTRODUCTION The existing Cabana Beach Club building is located seaward of the Coastal Construction Control Line (CCCL) in Ponte Vedra Beach, Florida, south of Corona Road on Ponte Vedra Blvd. The building s lowest point elevation seaward of the CCCL is + 12.48 NAVD and the site is in the flood plain VE 13. At the time of construction (1987), the 100-year storm surge (wave crest design) was + 11.9 NAVD; the new and current elevation of + 14.9 NAVD was established and accepted by St. Johns County with the understanding of having considered for a site specific determination of final elevation in lieu of the +16.2 NAVD for R-14 zone for St. Johns County. If any new construction is permitted within 5 years of one another and add s up to 50% of construction cost, the existing building would have to be raised up to the new wave crest design of + 14.9 NAVD, a minimum of + 2.42 FT. With the site located seaward of the CCCL, any new and large structural items requiring foundations would be required to use piles of nearly 30 (+14.9 storm surge + -14.9 = 29.8 ). With any new design and construction adjacent to the seashore and on/near the dunes, the approach is urged to be as least invasive as possible. Therefore, the overall design and construction regarding the existing Cabana Beach Club is needed to be low impact to the site and surrounding environment. YEAR BUILT...1987 VICINITY MAP PROJECT LOCATION OCCUPANCY TYPE / LOAD... A-2 ASSEMBLY (RESTAURANT) / 168 BUILDING STORIES / HEIGHT...2 / 39-9-1/4 BUILDING AREA... 6,900 SF 1ST FLOOR... 3,491 SF 2ND FLOOR... 3,409 SF BUILDING CONTRUCTION TYPE...V-B BUILDING RISK CATEGORY...II FLOOD ZONE...VE 13 WIND SPEED CATEGORY...130 MPH SURFACE ROUGHNESS...D EXPOSURE CATEGORY...D *All information above per Florida Building Code 5th Edition (2014) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

INTRODUCTION Existing on-site observation photographs below: VIEW FROM NORTHEAST AT SIDE YARD LOOKING SOUTH AT 2ND FLOOR INTERIOR SEATING LOOKING SOUTHWEST ON SOUTHEAST ELEVATIONAT 2ND FLOOR BALCONY LOOKING EAST AT 1ST FLOOR INTERIOR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

OPENING STATEMENT The following arguments are in response to the local jurisdiction (St. Johns County) requiring an existing restaurant that is seaward of the Coastal Construction Control Line (CCCL) [FBC 2014 3109] to be recognized as new construction and to comply with the requirements of Vertical Accessibility [FAC 2012 201.1 Vertical Accessibility] in that the building is to house an attached elevator [FAC 2012 206.6 Vertical Accessibility] although a Platform lift is permitted to be used in New Construction and in an Existing Building or Facility [FAC 2012 206.7]. Code References Florida Building Code, Accessibillity 2012 206.6 Elevators Elevators provided for passengers shall comply with 407. Where multiple elevators are provided, each elevator shall comply with 407. EXCEPTIONS: 1. In a building or facility permitted to use the exceptions to 206.2.3 or permitted by 206.7 to use a platform lift, elevators complying with 408 shall be permitted. 2. Elevators complying with 408 or 409 shall be permitted in multi-story residential dwelling units. Florida Building Code, Accessibillity 2012 206.7 Platform Lifts Platform lifts shall comply with 410. Platform lifts shall be permitted as a component of an accessible route in new construction in accordance with 206.7. Platform lifts shall be permitted as a component of an accessible route in an existing building or facility. Florida Building Code, Accessibillity 2012 3109 Structures Seaward of a Coastal Construction Control Line 3109.1 Scope. The provisions of Section 3109 shall ensure that structures located seaward of the coastal construction control line are designed to resist the predicted forces associated with a 100-year storm event and shall apply to the following (Exception 3 not included as N/A): 1. All habitable structures which extend wholly or partially seaward of a coastal construction control line (CCCL) or 50-foot (15.3 m) setback line. 2. Substantial improvement of or additions to existing habitable structures. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT A It is understood that a mandatory requirement placed by St. Johns County to provide an full service passenger elevator will incur hardship through disproportionate cost. The proposed alteration has an allocated $188,050 for the elevator, shaft, exterior finish, and deck extension compared to the overall $546,350 for other alterations within the scope of the project, that include other items needed for the opening of the exterior needed to accomplish the proposed work, is a difference of 34.42%. This difference in cost complies with the definition of disproportionate cost [FAC 202.4.1 Disproportionate Cost] The following items would be added into the cost of the elevator, beginning to end: 1 1) The elevator will require substantial foundations due to it s location seaward of the CCCL, having to use approximately 30-0 structural piles as explained previously in the Introduction (slide 3). 2) Even with a low-profile elevator, a shallow pit will be needed for the installation. This pit will be a minimum of 3-0 and, according to it s location on site at + 12.8 NAVD (southwest facade adjacent to entry stairs) which would place the finished floor of the pit at approximately +9.8 NAVD. This new elevation would be a 5.1 difference from the new 100-year storm surge. By having a pit at this location and low of an elevation, the building and it s elevator would be at risk of a maintenance-heavy accessible route which could impede the occupants per Advisory FAC 2012 407.1 and respective Federal Laws. 3) Due to the location of the required elevator, limited by FAC 206.3 and proximity to circulation paths, being seward of the CCCL, the excavation of the permeable surface, equipment needed for installation, and envrionmental impact of the construction process altogether, will have a negative impact on a delicate sight. Currently, beach and site erosion measures are being or have been completed in repairing the damage succumbed by Hurricane Matthew in 2016. 4) Lastly, the age of the building and condition due to it s proximity to the saltwater and sea air would need to be greatly altered beyond 50%/substantial completion as to trigger a near full demo of the structure in order for the elevator to be used to its maximum potential. If a new elevator were to be installed, it would outlast the building in terms of condition. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT A - SITE PLAN FLOOD ZONE VE13:14 BUILDING LOW POINT BUILDING SECTION CABANA BEACH CLUB ELEVATOR LOCATION CCCL n PONTE VEDRA BOULEVARD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT A SCOPE OF WORK WITH ASSOCIATED COST Total Elevator-related Associated Cost $ 188,050 Total Remaining Associated Cost $ 358,300 Total Cost $ 546,350 Total Elevator-related Associated Cost / Total Cost = Cost Ratio 188,050 / 546,350 = 34.42% If Ratio is greater than 50%, the building would be viewed as undergoing substantial completion and have to comply w/ new construction in regards to the storm surge height requirements enforced and recognized by Florida DEP and St. Johns County. Second Floor 1* New deck extension 2* New door at previous window opening 3* New detached Elevator Shaft w/ Roof 4 Roof repair 5 New exterior lighting 6 Existing deck repair 7* New wall opening at previous window locations 8 New entry stair replacement 9 New handrail replacement 10 New awning replacement 4 If Ratio is greater than 20%, the elevator would be recognized as undergoing Disproportionate Cost to the Extent of the Application and therefore would not be required to provide the vertical accessible item. First Floor 11* New deck extension support 12* New door at previous window opening 13* New detached Elevator Shaft w/ Elevator 14* Removal of pavers for deck extension support 15* Relocation of existing downspout 16 New exterior lighting 17 Replacement of pavers 18* New wall opening at previous window locations 19* Removal of three (3) palm trees 20 New ADA unisex restroom * = vertical accessible item-related scope 8 19* 19* 3* 7* 1* 11* 11* 19* 2* 14* 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT A SUPPORTIVE DRAWINGS FROM EXHIBIT A PLAN - FIRST FLOOR SOUTHWEST ELEVATION PLAN - SECOND FLOOR SOUTHWEST SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT A The items brought forth represented by Arguement A reinforce the need to have the FLorida ADA requirements for Vertical Accessibility to be waived due to hardships brought on by disproportionate costs to the scope of work to be performed. Code References Florida Building Code, Accessibillity 2012 202.4.1 Disproportionate Cost Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when the cost exceeds 20% of the cost of the alteration to the primary function area. Costs that may be counted as expenditures required to provide an accessible path of travel may include: (i) costs associated with providing an accessible entrance and an accessible route to the altered area; (ii) costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls; (iii) costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY); iv) costs associated with relocating an inaccessible drinking fountain. Florida Building Code, Accessibillity 2012 206.3 Location Accessible routes shall coincide with or be located in the same area as general circulation paths. Where circulation paths are interior, required accessible routes shall also be interior. Florida Building Code, Accessibillity 2012 Advisory 407.1 Elevators General The ADA and other Federal civil rights laws require that accessible features be maintained in working order so that they are accessible to and usable by those people they are intended to benefit. Building owners should note that the ASME Safety Code for Elevators and Escalators requires routine maintenance and inspections. Isolated or temporary interruptions in service due to maintenance or repairs may be unavoidable; however, failure to take prompt action to effect repairs could constitute a violation of Federal laws and these requirements. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT B It is understood that a Platform Lift is acceptable as an item to be used [per Platform Lifts 206.7] to fulfill the requirements of Vertical Accessibility 201.1. The following items are a response to use a Lift in lieu of an Elevator: 1) A shallow pit will be needed for the installation of any standard passenger elevator. This pit will be a minimum of 3-0 and, according to it s location on site at + 12.8 NAVD (southwest facade adjacent to entry stairs) which would place the finished floor of the pit at approximately +9.8 NAVD. This new elevation would be a 5.1 difference from the new 100-year storm surge. By having a pit at this location and low of an elevation, the building and it s elevator would be at risk of a maintenance-heavy accessible route which could impede the occupants per Advisory FAC 2012 407.1 and respective Federal Laws. 2) The lift can be customized with little extra cost to provide a 90 entry/exit while such requests for an elevator increases significantly. This 90 entry/exit is so that the deck would not have to extend further and wrap around the lift shaft thus not having to terminate into the existing glazing and host exterior wall. 3) An equipment room would not be needed due to less electrical and mechanical items required for operation. 3) Lastly, the age of the building and condition due to it s proximity to the saltwater and sea air would need to be greatly altered beyond 50%/substantial completion as to trigger a near full demo of the structure in order for the elevator to be used to its maximum potential. If a new platform lift were to be installed, it would be less intrusive on the installation due to its size. And, in the event of removal due to the age of the building, the removal of the lift would be less involved and have less impact than that of an elevator. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT B - SITE PLAN FLOOD ZONE VE-13:14 BUILDING LOW POINT BUILDING SECTION CABANA BEACH CLUB PLATFORM LIFT LOCATION CCCL n PONTE VEDRA BOULEVARD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT B SCOPE OF WORK WITH ASSOCIATED COST Second Floor 1* New deck extension 2* New door at previous window opening 3* New detached Platform Lift Shaft w/ Roof 4 Roof repair 5 New exterior lighting 6 Existing deck repair 7* New wall opening at previous window locations 8 New entry stair replacement 9 New handrail replacement 10 New awning replacement Total Lift-related Associated Cost $ 135,000 Total Remaining Associated Cost $ 358,300 Total Cost $ 495,300 Total Elevator-related Associated Cost / Total Cost = Cost Ratio 135,000 / 495,300 = 27.26 % 4 If Ratio is greater than 50%, the building would be viewed as undergoing substantial completion and have to comply w/ new construction in regards to the storm surge height requirements enforced and recognized by Florida DEP and St. Johns County. If Ratio is greater than 20%, the platform lift would be recognized as undergoing Disproportionate Cost to the Extent of the Application and therefore would not be required to provide the vertical accessible item. First Floor 11* New deck extension support 12* New door at previous window opening 13* New detached Platform Lift Shaft w/ Lift 14* Removal of pavers for deck extension support 15* Relocation of existing downspout 16 New exterior lighting 17 Replacement of pavers 18* New wall opening at previous window locations 19* Removal of three (3) palm trees 20 New ADA unisex restroom 8 1* 3,13* 11* 2* 10 * = vertical accessible item-related scope 19* 19* 19* 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT B SUPPORTIVE DRAWINGS FROM EXHIBIT B PLAN - FIRST FLOOR SOUTHWEST ELEVATION PLAN - SECOND FLOOR SOUTHWEST SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

ARGUEMENT B The items brought forth represented by Arguement B reinforce the need to allow a platform lift to be used in lieu of an elevator as enforced by the local jurisdiction per their interpretation of the Florida Building Code, Accessibility (2012). Any new work in providing vertical accessibility by means of a platform lift will be recognized to the Extent of the Application [FAC 202.3.2] Code References Florida Building Code, Accessibillity 202.3.2 Extent of Application. An alteration of an existing element, space, or area of a building or facility shall not impose a requirement for accessibility greater than required for new construction. Florida Building Code, Accessibillity 202.4 Alterations Affecting Primary Function Areas In addition to the requirements of 202.3, an alteration that affects or could affect the usability of or access to an area containing a primary function shall be made so as to ensure that, to the maximum extent feasible, the path of travel to the altered area, including the rest rooms, telephones, and drinking fountains serving the altered area, are readily accessible to nd usable by individuals with disabilities, unless such alterations are disproportionate to the overall alterations in terms of cost pursuant to 202.4.1. Florida Building Code, Accessibillity Advisory 202.4 Alterations Affecting Primary Function Areas (Continued) Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 of the code, apply to the path of travel upgrades required by 202.4. Florida requirements may be waived down to the ADA Standards requirements. Florida Building Code, Accessibillity 2012 202.4.1 Disproportionate Cost Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when the cost exceeds 20% of the cost of the alteration to the primary function area. Costs that may be counted as expenditures required to provide an accessible path of travel may include: (i) costs associated with providing an accessible entrance and an accessible route to the altered area; (ii) costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls; (iii) costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY); iv) costs associated with relocating an inaccessible drinking fountain. Florida Building Code, Accessibillity 2012 202.4.2 Accessible Features in the Event of Disproportionality When the cost of alterations necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall be made accessible to the extent that it can be made accessible without incurring disproportionate costs. In choosing which accessible elements to provide, priority should be given to those elements that will provide the greatest access, in the following order: (i) an accessible entrance; (ii) an accessible route to the altered area; (iii) at least one accessible restroom for each sex or a single unisex restroom; (iv) accessible telephones; (v) accessible drinking fountains; and (vi) when possible, additional accessible elements such as parking, storage, and alarms. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

CLOSING STATEMENT After extensive due diligence in the area of whether an elevator is required to be used in the current case of an existing seaside restaurant, seaward of the Coastal Construction Control Line (CCCL), built in 1987, we have found that we are not required due to the following discoveries: Scenario 1 In the event that the committee recognizes that both vertical accessible items (elevator and platform lift) are to be of Disproportionate Cost [FAC 204.2.1,2] compared to that of the remaining scope of work to be performed unrelated to these respective items, an elevator, platform lift, or any similar vertical accessible item with disporportionate costs would not be required for permit in St. Johns County, Florida. Scenario 2 In the event that the committee recognizes that an elevator is under Disproportionate Cost [FAC 204.2.1,2] and would go beyond the Extent of Application [FAC 203.2.3], a platform lift would be an acceptable use for vertical accessibility in lieu of an elevator. It is understood that the Florida requirements may be waived down to the ADA Standards requirements. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

EXHIBIT LIST EXHIBIT LIST EXHIBIT A... DRAWINGS w/ ELEVATOR EXHIBIT B... DRAWINGS w/ PLATFORM LIFT EXHIBIT C... ST. JOHNS COUNTY WATER SURGE CERTIFICATE LETTER EXHIBIT D... DRAWINGS w/ SITE PLAN W/ DEP SURVEY EXHIBIT E...ELEVATOR QUOTES EXHIBIT F...PLATFORM LIFT QUOTES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17