MICRO-INVERTER PIGRID W MICRO GRID TIED INVERTER 208, 220, 230, 240VAC

Similar documents
C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

TallSlateTM Grandee Installation Manual

Table of contents. 1. Introduction

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

MD Power Supply -48Vdc +Bias Tee

OptoLum MegaLine RGBW Luminaire

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ CBC] RESPONSE:

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Reference Information:

Ground Fault Protection. Medium Voltage Artificial Neutrals

2200-Lb. Semi-Electric Stacker OWNER S MANUAL

Installation and Operation Manual

User Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

HotSwap MBP Maintenance Bypass

Tindo Karra. Installation and Specifications Manual. Introduction

SelfCheck System R-Series. Site Planning Guide

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

DJ Switch 10F V2 ORDERCODE 50365

IEC Installation Guide for SERAPHIM Photovoltaic Module

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

INSTALLATION PROCEDURE

Agilent 16048D Test Leads

a-si/μcsi Tandem Module Installation Manual Macsun Solar Energy Technology Co., Limited Applied to MS-SDXX

64C Amplification Block. Instruction Manual

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

1 29SEP03 ALL General update with miscellaneous changes in entire document.

Adjustable Fused Power Supply

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Photovoltaic System Inspector Job Task Analysis Guide April 2017

SoliTek PV Modules INSTALLATION MANUAL

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710

SPORTSBEAMS 1500 LED USER MANUAL SPORTSBEAMS LIGHTING, INC. v.1.0

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

ENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL250A USER MANUAL DEALER:

Agilent 16047D Test Fixture

CITY & COUNTY OF DENVER COMMUNITY PLANNING & DEVELOPMENT BUILDING PERMIT POLICY

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

Carbon Canister Vapor Polisher

DIVISION 16. Electrical Specifications

CONTRACTOR S PERMIT APPLICATION for Residential PV Installation with e-inspection CA Health and Safety Code Section V p2s

General Safety Information

MANUAL ENGLISH. Ordercode: D3423/D3423W. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Agilent 16034E Test Fixture

Operation & Service Manual METTLER TOLEDO PFA220. Operation & Service Manual

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

XPI SERIES GRID SOLAR POWER SYSTEM

Objectives and Task Analysis for the Installer of Grid Connect Photovoltaic System

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

Quick-release pins swing the rack open from left to right to simplify installing and maintaining your equipment.

NY State Unified Solar Permit

DRUM-GRAB INSTRUCTION MANUAL

Pad and Pad/Transformer Modules

PHOTOVOLTAIC (PV) SUBMITTAL REQUIREMENTS

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

Small Scale Solar Permit Application

Permitting and Inspecting PV Systems. PV Codes and Standards 101. Photovoltaic System Basics

COOPER POWER SERIES. 200 A 15 KV, 25 KV and 35 KV class insulated protective cap installation instructions. Loadbreak Apparatus Connectors MN650035EN

Dynatronics Parallel Bars

BBL-4 FORK-MOUNTED BULK BAG LIFTER USE AND MAINTENANCE MANUAL

Bulletin Grounding and bonding of solar photovoltaic systems Rules , , , and

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

Saphyr System Safety Guide for Saphyr P/N 60325

WARNING ELECTRIC PALLET TRUCK EPT Revised A company dedicated to solving ergonomic and material handling problems since 1955.

Precision Automatic Vacuum Control (PAVC+)

Operation and Maintenance Manual

Building and Safety Division Public Information

NY State Unified Solar Permit

Model E100 Gauss Meter

YINGLI SOLAR TWINMAX MODULES Installation and User Manual

Installation. Basic Rack Power Distribution Units AP9560 AP9561

INSTRUCTION MANUAL WARNING: BEFORE USING THE MACHINE READ THE INSTRUCTION MANUAL CAREFULLY!

OPERATION MANUAL. A220 Arc Welding Machine. Serial Number: Where Purchase: Date of purchased:

DUST FREE ACTIVE Total Home Air Purification

NY State Unified Solar Permit

WITH THE TITLE 24. replacement. story. stories, etc. R disconnects. to, PV. unit and any. supporting frame. conditions. greater than the main

SECTION LOW-VOLTAGE TRANSFORMERS

Sby SR Instruments, Inc.

92831 TEL: (714) FAX:

2200 lb. Semi-Electric Stacker

RB088LAM150TF Schottky Barrier Diode

Agilent 7696A Sample Prep WorkBench

LITTLETON ELECTRIC LIGHT DEPARTMENT 39 AYER ROAD LITTLETON, MA (M) (F)

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

2016 V1 SERAPHIM ECLIPSE PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG

Address of Installation Building Permit #

P1902 Installation Manual

Thermoelectric Cooler

Basementsaver BP1 & BP2 Battery Backup Sump Pumps Installation

Operation and Service Manual

A. Section includes busway and fittings including plug-in units.

Dual Port isolated USB Charger

Transcription:

MICRO-INVERTER PIGRID250 250W MICRO GRID TIED INVERTER 208, 220, 230, 240V TECHNICAL MANUAL

CONTENTS INTRODUCTION ------------------------------------------------------------------------------ 3 SAFETY ------------------------------------------------------------------------------------------ 4 SYMBOL ILLUSTRATION -------------------------------------------------------------- 4 INSTALLATION WARNINGS ----------------------------------------------------------- 4 PREPARE FOR INSTALLING ------------------------------------------------------------- 6 TRANSPORTION AND INSPECTION ------------------------------------------------ 6 CHECK INSTALLATION ENVIRONMENT ---------------------------------------- 8 INSTALLATION POSITION ------------------------------------------------------------- 8 CHOOSE CABLE ---------------------------------------------------------------------- 9 MOUNTING AND WIRING ---------------------------------------------------------------- 10 INSTALLATION DIAGRAM ----------------------------------------------------------- 10 ASSEMBLY INSTRUCTIONS ---------------------------------------------------------- 13 Step 1. Wire Cable -------------------------------------------------------------------- 13 Step 2. Install Micro-inverter ------------------------------------------------------------ 13 Step 3. Grounding the System ----------------------------------------------------------- 14 Step 4. Fasten Cable ------------------------------------------------------------------ 15 Step 5. Connect Cable of Micro-inverter ------------------------------------------ 15 Step 6. Protecting Unused Ends --------------------------------------------------------- 17 Step 7. Connecting -TRUNK Cables to a Junction Box ------------------------- 17 Step 8. Drawing System Map ------------------------------------------------------------ 19 Step 9. Install Photovoltaic Modules --------------------------------------------------- 19 MAINTENANCE GUIDE ------------------------------------------------------------------- 21 ROUTINE MAINTENANCE ------------------------------------------------------------ 21 STORAGE AND DISMANTLING ----------------------------------------------------- 22 APPENDIX ------------------------------------------------------------------------------------- 23 TECHNICAL DATA ----------------------------------------------------------------------- 23 EFFICIENCY CURVES ------------------------------------------------------------------ 25 TEMPLATE FOR MAP OF MICRO-INVERTER INSTALLATION ---------- 26 Warranty Instructions ------------------------------------------------------------------------ 29

INTRODUCTION Thank you for using PIGRID250 Micro-Inverter! This Micro-Inverter system is the world s most technologically advanced inverter system with high efficiency, flexibility, safety and reliability for use in utility-interactive applications. This system is composed of a group of Micro-inverters that convert direct current () into alternating current () and feeds it into the electric grid. Different from systems that photovoltaic modules are subdivided into strings and controlled by one or several inverters, this system is built for the incorporation of a Micro-inverter for each photovoltaic module. Each Micro-inverter works independently of the others to guarantee maximum power of each photovoltaic module. This setup enables direct control over the production of a single photovoltaic module, consequently improving the flexibility and reliability of the system. This manual contains important instructions for the PIGRID250 Micro-inverter and must be read in its entirety before installing or commissioning the equipment. For safety, only qualified technician, who has received training or has demonstrated skills should install and maintain this Micro-inverter under the guide of this document. PIGRID250 is a 250W maximum Grid Tied Micro-inverter, and is designed to operate on 208Vac, 220Vac, 230Vac or 240Vac split phase grid connections. This document applies only to the inverter model listed in Table 1 below: Table 1 Output Power 250W Model Number PIGRID250 For technical assistance or to find out where to buy this or related products you may contact AIMS Power via email sales@aimscorp.net or Techsupport@aimscorp.net or call us at (775)359-6703.

SAFETY IMPORTANT SAFETY INSTRUCTIONS! PLEASE SAVE THESE INSTRUCTIONS IN A SAFE PLE! SYMBOL ILLUSTRATION The safety symbols used in this manual are list below and illustrated in detail. Symbol Usage Indicates a hazardous situation that can result in deadly electric shock hazards, other serious physical injury, or fire hazards. Indicates directions which must be fully understood and followed in its entirety in order to avoid potential safety hazards including equipment damage or personal injury. This points out that the described operation must not be carried out. The reader should stop, use caution and fully understand the operations explained before proceeding. INSTALLATION WARNINGS The PIGRID250 Micro-inverter is designed and tested according to international safety requirements (UL 1741/IEEE 1547). However, certain safety precautions must be taken when installing and operating this inverter. The installer must read and follow all instructions, cautions and warnings in this installation manual

All operations including transport, installation, start-up and maintenance, must be carried out by qualified, trained personnel. Before installation, check the unit to ensure absence of any transport or handling damage, which could affect insulation integrity or safety clearances. Choose installation location carefully and adhere to specified cooling requirements. Unauthorized removal of necessary protections, improper use, incorrect installation and operation may lead to serious safety and shock hazards or equipment damage. Before connecting the Micro-inverter to the power distribution grid, contact the local power distribution grid company to get appropriate approvals. This connection must be made only by qualified technical personnel. It is the responsibility of the installer to provide external disconnect switches and Overcurrent Protection Devices (OCPD). AIMS Power DOES NOT provide output overcurrent protection. To reduce the risk of fire, connect only to a circuit with 20A maximum branch circuit overcurrent protection in accordance with the National Electric Code (ANSI/NFPA 70) The output (neutral) is not bonded to ground. Only one photovoltaic module can be connected to the input of the inverter. Do not connect batteries or other sources of power supply. The inverter can be used only if all the technical characteristics are observed and applied. Do not install the equipment in adverse environment conditions such as flammable, explosive, corrosive, extreme high or low temperature, or extreme humidity. Do not use the equipment when the safety devices do not work or are disabled. Use personal protective equipment, including gloves and eye protection when working. Inform the manufacturer about non-standard installation conditions. Do not use the equipment if any operating anomalies are found. Avoid temporary repairs. All repairs should be carried out using only qualified spare parts, which must be installed in accordance with their intended use and by a licensed

contractor or authorized AIMS Power service representative. Liabilities arising from commercial components are delegated to their respective manufacturers. Anytime the inverter has been disconnected from the power network, use extreme caution as some components can retain charge sufficient to create a shock hazard. Prior to touching any part of the inverter use care to ensure surfaces and equipment are at touch safe temperatures and voltage potentials before proceeding. AIMS Power accepts No liability for damage from incorrect or careless operation PREPARE FOR INSTALLING TRANSPORTION AND INSPECTION AIMS Power packages and protects individual components using suitable means to make the transport and subsequent handling easier. Transportation of the equipment, especially by road, must be carried out by suitable ways for protecting the components (in particular, the electronic components) from violent, shocks, humidity, vibration, etc. Please dispose of the packaging materials in an appropriate way to avoid unforeseen injury. It is the customer s responsibility to examine the condition of the components transported. Once receiving the Micro-inverter, it is necessary to check the container for any external damage and verify receipt of all items. Call AIMS Power, the Shipper or the carrier immediately if damage or shortage is detected. If inspection reveals damage to the inverter, contact the supplier, or authorized distributor for a repair/return determination and instructions regarding the process. Table 2 lists components for use with PIGRID250,

Table 2 Code trunk spool_41inches_50plugs Description cable (4conducotors) 10AWG Plug inches 41 trunk spool_67inches_32plugs cable (4conducotors) 10AWG Plug inches 67 trunk spool_81inches_27plugs cable (4conducotors) 10AWG Plug inches 81 trunk plug cap Insulated cap for cable connectors trunk end cap End cap for 10 AWG cable trunk unlock tool Tool for releasing connectors

CHECK INSTALLATION ENVIRONMENT Installation of the equipment is carried out based on the system design and the place in which the equipment is installed. The installation must be carried out with the equipment disconnected from the grid (power disconnect switch open) and with the photovoltaic modules shaded or isolated. See Appendix: Technical Data to check the environmental parameters to be observed (degree of protection, temperature, humidity, altitude, etc.) To avoid unwanted power de-rating due to an increase in the internal temperature of the inverter, do not expose it to direct sunlight. To avoid overheating, always make sure the flow of air around the inverter is not blocked. Do not install in places where gasses or flammable substances may be present. Avoid electromagnetic interference that can compromise the correct operation of electronic equipment. INSTALLATION POSITION When choosing the position of installation, comply with the following conditions: Install only on structures specifically conceived for photovoltaic modules (supplied by installation technicians). Install Micro-inverter underneath the photovoltaic modules so that they work in the shade. If this condition cannot be met, the inverter could undergo de-rating.

PV Module Micro Inverter Fig.1. Installation position of Micro-inverter CHOOSE CABLE The cable is shipped on a reel with the connectors pre-mounted. The available spacing between connectors is: 41, 67, and 81. The installer is responsible for choosing the cable model with the correct spacing on the basis of the orientation (shown below) and type of photovoltaic modules. Observe the certification documents concerning the maximum number of Micro- inverters permitted for installation at each cable section! Table 3 Cable Items Photovoltaic Modules Orientation Illustration -TRUNK Spool 41 Inches 50 Plugs 60 Cells

-TRUNK Spool 41 Inches 50 Plugs 72 Cells -TRUNK Spool 67 Inches 32 Plugs 60 Cells -TRUNK Spool 81 Inches 27 Plugs 72 Cells * Note: The -TRUNK SPOOL may contain a number of connectors indicated by the number of plugs in the part number. The installer may cut the cable to the length needed for the specific installation. MOUNTING AND WIRING INSTALLATION DIAGRAM System Schematic Diagram

Red: L1 Black: L2 White: Neutral Green: Ground PV Model Micro Inverter Cable Distribution Panel Junction Box Fig.2. 208Vac three phase Red: L1 Black: L2 White: Neutral Green: Ground PV Model Micro Inverter Distribution Panel Junction Box Cable Fig.3. 220Vac, 230Vac, 240Vac split phase

Assembly Diagram Trunk End Cap PV Module Bracket Micro Inverter Trunk Cable Plug Junction Box Cables From PV Module Fig.4. Assembly Illustration

ASSEMBLY INSTRUCTIONS Step 1. Wire Cable Wire the cable along the frame structure of photovoltaic modules. Bracket Trunk Cable Plug Fig.5. Wiring the cable Ensure that the cable matches the installation conditions, particularly in regards to the number of the modules and their orientation. The number of the Micro-inverters should not exceed the maximum number permitted for installation. Step 2. Install Micro-inverter Mark the approximate center of each photovoltaic module on the frame and install the Micro-inverter with the logo side facing downwards. Ensure that the Micro-inverter does not block the stiffening braces of the photovoltaic modules and the connector can easily reach the connector on the cable.

The Micro-inverter must be under the module, out of long-term exposure to direct sunlight or rain. Step 3. Grounding the System The system must be grounded according to local laws. The inverter can typically be earth grounded using the connector clamp secured to the chassis and an adequately-sized conductor. Equipment grounding conductor coupling all of the MICRO inverters: The conductor must have a minimum cross section of 6 AWG(4.11mm) Fig.6. Typical Grounding Incorrect grounding may cause physical injury, death or equipment malfunction and increase electromagnetic interference. Make sure that grounding conductors are adequately sized as required by safety regulations.

Step 4. Fasten Cable Fasten the cable to the frame with cable ties or tie wraps. Each connector is provided with two slots for ideal fastening. If using nylon or materials that may decompose in sun light or over time, it is strongly recommended to inspect on occasion. Fig.7. Fasten Cable Step 5. Connect Cable of Micro-inverter Remove the temporary cap and then connect the cable of the Micro-inverters to the -TRUNK cable connectors. The connectors are coupled correctly when two clicks are heard.

Trunk Unlock Tool Trunk Cable Temporary Plug Cap Micro Inverter Drop Cable Fig.8. Connect Cable of Micro-inverter The -TRUNK UNLOCK TOOL must be used for the disconnection of the connector from the MICRO inverter or for the removal of the -TRUNK PLUG CAP from the connectors on the TRUNK cable. Protect any unused -TRUNK cable connectors by fitting the -TRUNK PLUG CAP on them to keep them watertight. The temporary caps are only fitted for shipping and provide no seal whatsoever! Trunk Plug Cap Trunk Cable Temporary Plug Cap Fig.9. Unused Connectors

Step 6. Protecting Unused Ends The unused ends of the -TRUNK cable must be terminated with the proper end. Fit the appropriate -TRUNK END CAP on the unused ends of the -TRUNK cable. Trunk End Cap Fig.9. Unused Ends Step 7. Connecting -TRUNK Cables to a Junction Box Connect the -TRUNK cables coming from the MICRO inverters to a junction box. Close the junction box after the wiring is complete. Ensure that the seal is tight. Fig.10. Junction Box To prevent electrical hazards, all the connection operations must be carried out with the equipment disconnected from the grid. All the external connections to the insulated junction box (caps, adapters, etc.) should be made with securely-sealed AIMS Power components.

AIMS Power cables from the Micro-inverters have four conductors with different colors to identify the function of each conductor: Table 4 Code trunk spool_41inches_50plugs Description cable (4conducotors) 10AWG Black: L2 White: Neutral Plug inches 41 Red: L1 Green: Ground trunk spool_67inches_32plugs cable (4conducotors) 10AWG Plug inches 67 trunk spool_81inches_27plugs cable (4conducotors) 10AWG Plug inches 81 Pay special attention and ensure not to reverse the phase (load lines) with the neutral! The installation technician is responsible for selecting a junction box with the appropriate dimensions and insulation. The installation technician is responsible for selecting a cable running between the junction box and the load distribution panel with the appropriate length and cross section.

Step 8. Drawing System Map Draw a map of the system, affixing the extra label that comes attached to each inverter, on the appropriate position on the diagram (found in the Appendix of this manual). Customer Information: Please affix the extra label that comes from each inverter, on the appropriate position on this diagram. 1 2 3 4 5 A B C D E Fig.11. System Map Step 9. Install Photovoltaic Modules Install the photovoltaic modules, and connect the cables of the modules to the corresponding input side of the Micro-inverter.

Cable From PV Module Cable From Micro Inverter Fig.12. Connect Cables The recommended installation requires keeping the Micro-inverters underneath the photovoltaic modules, so that the Micro-inverters can operate in the shade. Direct sunlight may cause damage to the Micro-inverters and will at minimum de-rate the performance. Each module must be connected to the Micro-inverters with a cable having a length of less than 3m.

MAINTENANCE GUIDE ROUTINE MAINTENANCE Only authorized personnel are allowed to carry out the maintenance operations and are responsible to report any anomalies. Always use personal protective equipment when working on or around power equipment. During normal operation, check that the environmental and logistical conditions are correct. Make sure that the conditions have not changed over time and that the equipment is not exposed to adverse weather conditions and has not been covered with foreign bodies such as filth or vegetation. DO NOT use the equipment if any problems are found, and restore to normal conditions after the fault has been removed. Conduct an annual inspection on various components, and clean the equipment with a vacuum cleaner or special brushes. Do not hose down the inverters directly. Do not attempt to dismantle the Micro-inverter or make any internal repairs! In order to preserve the integrity of safety and insulation, the Micro-inverters are not designed to allow internal repairs! The output wiring harness ( drop cable on the Micro- inverter) cannot be replaced. If the cord is damaged the equipment should be scrapped. Maintenance operations must be carried out with the equipment disconnected from the grid (power switch open) and the photovoltaic modules obscured or isolated, unless otherwise indicated.

For cleaning, DO NOT use rags made of filamentary material or corrosive products that may corrode parts of the equipment or generate electrostatic charges. Avoid temporary repairs. All repairs should be carried out using only genuine spare parts. STORAGE AND DISMANTLING If the equipment is not used immediately or is stored for long periods, check that it is correctly packed. The equipment must be stored in well-ventilated indoor areas that do not have characteristics that might damage the components of the equipment. Perform a complete inspection when restarting your system after a long period of being unused. Please dispose of the equipment properly after scrapping, as it is potentially harmful to the environment, in accordance with the regulations in force in the country of installation.

APPENDIX TECHNICAL DATA Model Input data() Recommended PV module power (STC) range (W) PIGRID250 200~310 MPPT voltage range (V) 27~48 Operating voltage range (V) 16~60 Maximum input voltage (V) 60 Maximum input current (A) 10 Maximum input source back feed current to input source (A) -36 Output Data () Rated output power (W) 250 Rated output current (A) 1.04 Nominal output voltage/range (V) 240/211-264 1 Nominal frequency/range (Hz) 60/57-60.5 1 Power factor >0.99 Output current harmonic distortion <3% Maximum output overcurrent protection (A) 20 Maximum Units per 20A Branch 14 Maximum output fault current (ac) and duration 66.67 Apk, 2.13 ms of duration, 11.22 Arms

Utility interconnection voltage and frequency trip limits and trip times See Note 1 below. Trip limit and trip time accuracy Voltage: +/- 1% Frequency: +/- 0.1 Hz Alternate Trip Time +/- 50 ms Efficiency Peak inverter efficiency 96.5% CEC weighted efficiency 96.0% Nominal MPPT efficiency 99.9% Mechanical Data Ambient temperature range ( ) -40 ~ +65 Operating temperature range ( ) -40 ~ +85 Dimensions (W H D mm) 165 183 28 Weight (kg) 1.5 Enclosure rating Cooling NEMA6 Natural convection Features Communication Warranty Wireless Standard,15years Option, 20/25 years extended 1 Voltage and frequency ranges can be extended beyond nominal if required by the utility

Efficiency, % Notes: Utility Interconnection Voltage and Frequency Trip Limits and Trip Times: Voltage and frequency limits for utility Interaction Condition Simulated utility source Voltage (V) Frequency (Hz) Maximum time (sec) (cycles) at 60 Hz a before cessation of current to the simulated utility A < 0.50 V nor Rated 0.16 B 0.50 V nor V < 0.88 V nor Rated 0.16-5 C 1.10 V nor < V < 1.20 V nor Rated 0.16-5 D 1.20 V nor V Rated 0.16 E Rated f > 60.5 0.16 F Rated f < (59.8-57.0) (adjustable set point) 0.16-300 seconds (adjustable) EFFICIENCY CURVES 100 95 90 CEC Efficiency = 96.5% 85 80 75 27 Vdc 37 Vdc 48 Vdc 70 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of Rated Output Power

TEMPLATE FOR MAP OF MICRO-INVERTER INSTALLATION Customer Information: Please affix the extra label that comes from each inverter, on the appropriate position on this diagram. 1 2 3 4 5 A B C D E

Red: L1 Black: L2 White: Neutral Green: Ground PV Model Micro Inverter Cable Distribution Panel Junction Box 208Vac three phase

Red: L1 Black: L2 White: Neutral Green: Ground PV Model Micro Inverter Distribution Panel Junction Box Cable 240Vac split phase

Warranty Instructions: This product is designed using the most modern digital technology and under very strict quality control and testing guide lines. If however you feel this product is not performing as it should, please contact us: techsupport@aimscorp.net or (775)359-6703 We will do our best to resolve your concerns. If the product needs repair or replacement, make sure to keep your receipt/invoice, as that will need to be sent back along with the package and RA# prepaid to AIMS. You have a full 1 year from date of purchase warranty. This warranty is valid world wide with the exception that freight and duty charges incurred outside the contiguous 48 United States will be prepaid by customer. Except as provided above, AIMS makes no warranty of any kind, express or implied, including without limitation the implied warranties of merchantability and fitness for a particular purpose. In no event shall AIMS be liable for indirect, special or consequential damages. This warranty only applies to AIMS Power branded products. All other name brand products are warranted by and according to their respective manufacturer. Please do not attempt to return non-aims Power branded products to AIMS Power. For additional products such as: - Modified sine wave inverters - Pure sine wave inverters - Low Frequency Inverters - Solar Charge Controllers - Micro Grid Tied Inverters - Inverter Chargers and Automatic transfer switches - Converters - and - - Custom cut cables - Batteries - Solar Panels & Racks Please visit our web site: www.aimscorp.net To find out where to buy any of our products, you may also e-mail: (775)359-6703. sales@aimscorp.net or call