fig. 1, 2 Esslingen, Germany: FESTO AG, 1,330 m² gross collector area for cooling and heating

Similar documents
Technical Guide to Solar Thermal. Better World Energy. How to harness the sun s energy and create hot water with a Solar Thermal System

CPC EVACUATED TUBE COLLECTOR SYSTEMS FOR PROCESS HEAT UP TO 160 C

Guidance page for practical work 1: modeling of a thermodynamic solar plant

SorTech package solution description

Renewable Energy. to heat your home. thermia.com

SOLAR COOLING WITH SMALL SIZE CHILLER: STATE OF THE ART

HIGH PERFORMANCE SOLAR THERMAL SOLUTIONS

UNIT FOUR SOLAR COLLECTORS

use Solar thermal for hot water production DESIGN APPROACHES

Solar Boiler Concept for Concentrating Solar Power Plants. Ulrich Hueck, Dr.-Ing. Co-Founder

S O L A R C O OL I N G F O R A S U S T A I N A B L E EN E R G Y F U T U R E MARA MORBIN ITALY

Lecture 4: Solar Thermal Heat Utilization

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

use Solar thermal for hot water production

BASIC EUROPEAN GLAZED COLLECTORS & SOLAR DOMESTIC

Solar Air-Conditioning Systems in small - medium scale applications

Solar Heating in Commercial Buildings

Solar Cooling Technologies for Southern Climates - A System Comparison

Innovative Systems for Solar Air Conditioning of Buildings

Physics 100 Lecture 19. Solar Thermal Energy April 9, 2018

Solar Thermal Market & support schemes in Germany. German Solar Industry Association (BSW-Solar)

Siemens Solar Energy. Buenos Aires, November 2011 By Rolf Schumacher R2 Siemens AG All rights reserved

Dimensioning a small-sized PTC solar field for heating and cooling of a hotel in Almería (Spain)

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

Components of building integrated solar collectors

MEASUREMENTS AND BENCHMARK OF PV-T COLLECTORS ACCORDING TO EN12975 AND DEVELOPMENT OF A STANDARDIZED MEASUREMENT PROCEDURE

Camel Solar brings you some of the most advanced solar thermal systems available on the market today through innovation, research and development.

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Solar Thermal. [Strategy]

HEATING SYSTEM RETURN TEMPERATURE EFFECT ON HEAT PUMP PERFORMANCE

Solar Thermal Systems for Buildings

COMPLETE TEST FACILITY FOR SOLAR THERMAL COLLECTORS AND SYSTEMS

Tasks of the planner

Solar Energy Technologies

Solar-Thermal Feasibility Study Farm #5 Boutique Winery

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Thermal Analysis of Solar Flat Plate Collector

FLATE Hillsborough Community College - Brandon (813)

Int. J. Energy Technology and Policy, Vol. 3, Nos. 1/2,

Description and Visual Representation of Most Promising Markets

Advanced Storage Concepts for Solar Combisystems

Available online at ScienceDirect. Energy Procedia 49 (2014 ) SolarPACES 2013

Solar thermal heating systems in European Union

Section 5. Renewable Energy Sources Solar and Wind. What Do You See? Think About It. Investigate. Learning Outcomes

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

Digging Deeper SOLAR ENERGY. Forms of Solar Energy

Solar Thermal. The sun is but a morning star. Henry David Thoreau

Solar Cooling for Southern Climates, Double Effect Absorption Chillers with High Concentrating Collectors Versus Standard Single Effect Systems

Investigation of a Solar active glass facade

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

DEVELOPMENT OF A SOLAR COLLECTOR/SOLAR WATER HEATING SYSTEM TEST CENTER IN IRAN

Exergy analysis of a flat plate solar collector

SUPERB CLIMATE SOLUTION WITH A PROVEN RECORD

Solar Calculations for the Raseiniai District Heating Plant

Funded by. EU GCC CLEAN ENERGY NETWORK II Join us: Contact us:

Potentials of the new design concepts of district heating and cooling toward integration with renewable energy sources

BY HARNESSING THE POWER OF THE SUN WE ARE ABLE TO PRODUCE HOT WATER AND ELECTRICITY FROM AN INEXHAUSTIBLE SOURCE WITHOUT ADDING TO THE CARBON LEVELS

Thermodynamic Simulation of an Advanced Hybrid Solar-Gas Seawater Desalination System

Continental J. Engineering Sciences 6 (1): 24-30, 2011 Wilolud Journals, 2011 ` Printed in Nigeria

Colorado Energy Masters: Solar Energy. Kurt M. Jones County Extension Director Chaffee County

Comfort Cooling Application Using Fixed Focus Solar Parabolic Dish Concentrator Integrated with Double Effect Vapor Absorption Machine

FIRST LARGE-SCALE SOLAR SEASONAL BOREHOLE THERMAL ENERGY STORAGE IN CANADA

Performance of a Solar Heating System with Photovoltaic Thermal Hybrid Collectors and Heat Pump

Australian Solar Cooling Interest Group (ausscig) Conference DHW/COOLING HYBRID STRATEGY FOR SOLAR COOLING:

REPORT ON THE BENEFITS OF ICE- BASED THERMAL STORAGE FOR DISTRICT COOLING IN THE UAE MARKETS

ACTIVE SOLAR SYSTEMS

Effect of Distance between Double Glazing on the Performance of a Solar Thermal Collector Control

Green Building Handbook for South Africa Chapter: Energy Generation Luke Osburn CSIR Built Environment

Activity 2.2.3A Heat Loss and Gain (Revised)

Solar Flat Plate Thermal Collector

Solar Thermal Systems- A reliable technology for Green Buildings

RESEARCH OF SOLAR WATER HEATERS MODEL

Study of Performance of Solar Photovoltaic Thermal Collector at Different Temperatures

Solar process heat for sustainable automobile manufacturing

Solar Energy Today s Clean Energy Choice

Modeling and analyzing solar cooling systems in Polysun

Feasibilty of Wind-Solar Hybrid System for Cleveland, Ohio, USA

New Technologies and Opportunities for Solar Thermal Applications

Experimental Research and Performance Analysis of a Solar-Powered. Air-conditioning System in a Green Building

SOLAR THERMAL IT S HOT AGAIN! Solar Water Heating and Solar Thermal Energy Solutions

DESIGN AND EXPERIMENT OF PARABOLIC TROUGH COLLECTOR WITH NORTH-SOUTH ORIENTATION

Energy efficiency of a solar domestic hot water system

Reference System, Germany Solar combi system for DHW* preparation and space heating

Solar absorber coatings

ENGINEERING DESIGN GUIDE UNITHERM...

Although electricity is efficient at heating water it is expensive and not available everywhere.

Contributions of Solar Thermal to Energy Efficiency in the Tourism Sector

A Review of Solar Collectors in Solar Thermal Applications

Product catalogue A25s. Solar Cooling systems

Performance Evaluation of Solar Parabolic Trough for Cloths Laundry application

Renewables. Vacuum Tube Solar Systems. Solar Energy to the Power of

Figure 1: Uncovered and covered PVT collectors

Customized Absorption Heat Pumps for Utilization of Low-Grade Heat Sources

Reminder: Solar and Terrestrial Radiation

Product catalogue A25s. Solar Cooling systems

Renewable energy from the sun Daikin solar thermal systems for the installer

Large Scale Solar Thermal Systems Design Handbook

Unit 7 Overview of Solar Thermal Applications

Reminder: Solar and Terrestrial Radiation

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

Transcription:

The Key For Optimizing Large-Scale Solar-Thermal Systems is Combining Parabolic Mirrors, Evacuated Tube Collectors and H2O Rolf Meissner and Stefan Abrecht 1. Abstracts After nearly 2 years of research and development, as well as the practical experience gained through the installation of more than 3, systems using the AquaSystem principle (pure water as the heat transfer fluid), it is evident that utilizing Concentrating Parabolic Compound (CPC) Mirrors with Evacuated Tube Collectors (ETC) in the construction of large scale solar thermal systems produces superior results. High temperature collectors increase the efficiency factor, allow an all-season application and are the key for effective heat storage. 2. Some actual examples Paradigma, a German high-tech company specializing in solar thermal systems, engineers large scale solar systems designed to be integrated into conventional hydronic heating and domestic hot water systems. Since 26 more than 5 installations have been commissioned, including the project for FESTO. The FESTO system is the largest solar cooling system in the world, installed with 1,33 m² (14,363 sq. ft.) of Paradigm s CPC-ETC collectors. This solar field delivers heat to an adsorption chiller, cooling 27, m² (291,6 sq. ft.) of office space in summer. Since the existing hydronic network is so large, the interface was accomplished without a heat exchanger, requiring only a simple buffer storage tank of 17 m³ volume (4,49 gallons) (fig. 1, 2, 3). fig. 1, 2 Esslingen, Germany: FESTO AG, 1,33 m² gross collector area for cooling and heating The collector field does not contain any de-aerators, valves or other devices in the outdoor area. While the final design is quite simple, the calculations for self-filling and self-de-aerating require complex mathematical thermal hydraulic calculations. solar applicationcooling at 75-95 C (167 23 ºF) heating at 5-7 C (122 158 ºF) collector gross area 1,33 m² (14,363 sq ft) volume flow 3 m³/h (7,925 gal hr) storage tank 17 m³ (4,49 gal) peak power 1.2 MW (4.1 Mio BTU/hour) max. continual power.65 MW (2.2 Mio BTU/h) guaranteed yield 5 MWh (1.71 Billion BTU) p. annum electrical energy req. 2.5 MWh (8.53 Million BTU) p. annum fig. 3 FESTO, hydraulic scheme, source (HfT-Stuttgart, FESTO AG)

This system was delivered with a performance guarantee from Paradigma and the energy delivered to-date exceeds forecast. On sunny winter days nearly 4.3 MWh of power are delivered to the tank at temperatures greater than 8 C (176 ºF) (fig. 4). The collector output during this time is 3.2 kwh per square meter gross collector area an outstanding result for a day in February. fig. 4 FESTO AG, temperatures and energy yield on February 24th 28 In other installations an additional storage tank was expendable because the hydraulic system was able to absorb the solar energy as it was generated. This is often the case in industrial systems since the volume of water in the existing hydronic system is large enough to readily absorb the solar input. As a prototype a solar thermal system for a large sauna bath was installed like an additional boiler (fig 5, 6). The solar heat is directly fed into the existing heating network (fig. 7). fig. 5, 6 Grafschaft, sauna bath, 98 m² collector area, support of a heating network solar application all-season support of an existing heating network at about 65 C (149 ºF) collector area 98 m² gross (1,55 sq ft) storage tank none guaranteed yield about 5 MWh (.17 Billion BTU) or 5 kwh/m² respectively per annum electrical energy req. 38 kwh (1.3 Mio BTU) per annum fig. 7 direct supply of hydraulic networks The sauna bath installation proves that a direct feed hydraulic principle can be applied to district heating networks. In the near future we believe connecting solar fields to district heating systems will be common practice, resulting in benefits to communities, the environment and the solar industry. Many standard large scale solar systems are running without complication. Predictable performance, no downtime and low maintenance are common characteristics. The key design feature that allows trouble free operations is water using water as the solar collector heat transfer fluid removes most of the complications for transferring heat downstream of the collector field. Commercial buildings,

condominiums, hospitals, schools and gyms, hotels, restaurants, and industrial operations are all benefiting from the Aqua Principle (fig. 8). fig. 8 large-scale solar-thermal systems for domestic hot water and space heating 3. History At the end of the 199 s the prospects for expanding the application of cost effective solar thermal collectors was not promising. Flat plate collectors achieved high stagnation temperatures, but their efficiency at temperature of 6 to 15 C (14 to 32 ºF) was not promising. In addition, the problem of stagnating glycol-filled collectors is accentuated at higher temperatures. The primary design effort at this time was focused on preventing stagnation, which was critical. A standard solution was to use a huge storage tank, which partially solved the problem of stagnating collectors, but greatly reduced the cost effectiveness of the installation. Paradigma has been involved in solar research and development since 1988, and launched an innovative flat plate design many years ago. In 1997 Paradigma forged a new path and turned to vacuum tube technology. Paradigma s superior design and focus on quality has been widely accepted, evidenced by its more than 5 % market-share of ETC in Europe. Paradigma is a vertically integrated manufacturer, having control over every production process, from molten glass to forming of highprecision CPC mirrors; cutting, forming and brazing of internal pipe works, assembly and final quality test. The double wall vacuum tube system results in minimal heat losses and is key to applying Paradigma s patented frost protection technology. Paradigma is the first and only company that has overcome the problems associated with using water in year-round pressurized solar systems. With high-efficiency collectors and sophisticated feeding algorithm, the solar system can be protected from freezing in a cost effective way. 4. The heat transfer medium water In 23 Paradigma introduced the AquaSystem, which uses water as the heat exchange medium. Because of the low heat losses of the CPC vacuum tube collectors, only a small amount of energy, about 2 to 4 % of the yearly solar energy gain, is required for frost protection. In most cases this is stored solar energy that is not needed for domestic hot water requirements. Achieving frost protection by returning a small amount of unutilized solar hot water was a major advancement to existing solar technology and resulted in the award of the German Federal Award Bundespreis 26. The market has fully embraced the AquaSystem, as more than 35, systems are now installed. The advantages of the AquaSystem over conventional solar collector systems are numerous. The operation with water - allows easy, direct connection to the in-house heating network, - requires less equipment such as heat exchangers, de-aerators, valves, pumps and controllers, - is the precondition for the use of efficient, small, single coil storage tanks,

- eliminates the high costs for antifreeze and the associated running costs, - considerably reduces the cost and time for installation, commissioning and repairs, - ensures a long operating life with almost constant performance, - removes all risks associated with thermal stagnation and - minimizes maintenance costs and downtime. Using state-of-art CPC vacuum tube collectors ensures a maximum harvest of solar energy and a system that has a long operating life and is virtually maintenance free. Unfortunately, full recognition of the significant benefits of water compared to glycol has yet to be fully incorporated in the technical standards. Chapter 7 of DIN EN 12975 is related to power performance and was published without consideration between the physical differences of these two fluids. At an operating temperature of 4 C (14 ºF) glycol has only 88 % of the heat capacity, 62 % of the heat conductivity, 75 % of the heat-transfer coefficient, up to 3.85 times higher pressure losses and 3.8 times the viscosity of water. In addition, a water-glycol heat exchange requires up to 3 times the heat exchanger area than a water-water heat exchange to get the same number of transfer units. And the higher the temperatures are, the wider the performance differences. These large differences are also ignored in solar simulations programs, ratings issued by independent testing agencies, dollar-based tax rebate programs, technical training programs and marketing literature of those companies whose products are tested and rated with water, but installed using glycol. 5. Function control and system monitoring Germany has the largest solar market in Europe. It also is well know for the high level of training and skill of its craftsmen. But a recent market study concluded that as many as twenty-five percent of solar systems installed in Germany were not working as designed. It is easy to understand how this could occur if it is known that almost all these systems were conventional glycol system with boiler back-up heat. If the system doesn t freeze and there is hot water at the faucet, there is no suspicion of a problem. However, installations without antifreeze must be error-free. The Paradigma AquaSystem is equipped with a solar controller that has sophisticated and reliable diagnosis software which constantly monitors the system. If the system does not perform the way it was designed, an acoustic alarm will call attention to the deficiency. 6. The storage of solar thermal heat Having a clear understanding of the temperature stratifications in storage tanks is critical in optimizing the design of the solar system. This knowledge will impact the number of collectors, the size of the tank, the temperature coming from the collector, and piping arrangements. Our principal concept is to avoid large storage tanks for domestic hot water applications. Using set-point control logic, high temperature water is delivered into the top of the tank in small bursts or buckets. Supplying hot water from the collector in this fashion results in higher stratification layers in the tank. Domestic water is drawn from the top of the tank, and after mixing, the quantity of hot water at the facet can exceed that provided by tanks twice the size. Stagnation is a normal operating condition in water systems. If the domestic water tank and / or the heating buffer tank are heat saturated, the collector water will steam off without incident, condensing into the domestic water coil or expansion tank. During the stagnation period, the system cannot be activated until the collector cools and water is pushed back into the collector from the expansion tank. In most cases stagnation will occur late in the day and since the storage tanks are at heat capacity, the homeowner experiences no loss of solar performance. In the near future, restarting Paradigma Aqua Systems from thermal standstill will be standard. This will allow the utilization of the storage capacity of collector field, which holds.5 kwh per m² collector area and represents about 1/1 of the annual energy harvest in a residential system. A solar collector system that can be restarted from standstill at any time promises a much higher annual energy harvest and will allow for a reduction in collector field sizes and water storage tank sizes.

7. The power performance of several solar-thermal collectors The thermal efficiency factor is also known as the collector efficiency factor, represented as η(x). It is the percentage of the energy provided by the sun that the collector can convert to heat water. It can be easily calculated at any operating point from the three performance variables issued after the Solar Keymark Tests. Those performance variables are: conversion factor η, loss coefficient factor a1, and loss coefficient factor a2. Since the efficiency of a collector moves in a non-linear way to changes in insolation level (G s in watts / m²), ambient temperature (T u ) and average (T inlet + T outlet / 2) manifold water temperature (T k ), these variables must also be known. So the formula to calculate the thermal efficiency of a solar collector is: G = Gs η(x) = Gs {η (a 1 x/gs) (a 2 x²/gs) where x = (T k - T u ) / G s } The characteristic curves in the following diagram are based on gross collector area, since installations are planned, paid for and subsidized on this basis. Global irradiation (direct + diffuse): 4 W/m² 127 BTU / (ft² h) collector power in Watt/m² gross area 3 25 2 15 1 5 5 86 122 158 194 23 266 32 338 374 41 1 <Tu>= 1 C 3 5 7 Delta T = <Tk> - <Tu> C P C vacuum tubes, optimum heat pipe vacuum tubes double glazed flat plate average flat plate 9 mean process temperature <Tk> in F 11 13 15 17 19 21 mean process temperature <Tk> in C C P C vacuum tubes 9 8 7 6 5 4 3 2 1 Q'_collector in BTU / (ft²h) gross area vacuum tubes, direct flo wing thro ugh large-scale flat plate swimming poo l abso rber fig. 9 Heat power performance of collectors at an irradiation of 4 W/m² The graft in figure 9 assumes an ambient temperature T u of 1 C (5 ºF) and irradiation G s of 4 W/m². The other factors that determine the slope of the graph are based on the three performance variables from the SolarKey Mark test. The x-axis is the average water temperature (it approximately corresponds with the process temperature) based on an ambient temperature of 1 C (5 ºF). The diagram demonstrates that when flow rate temperatures are between 35 to 5 C (95 to 122 ºF) all flat plate collectors drop under 15 W/m² (48 BTU/ft²h), while existing CPC vacuum tube collectors deliver this power at 9 C (194 ºF). The green broken line represents a theoretical CPC vacuum tube collector that could be manufactured based on state of the art methods. fig. 1 irradiation time in hours with different specific power at the German reference site Wurzburg If there is no temperature difference T, every collector achieves its individual maximal efficiency factor η. The hotter the collector, the higher the T, but the efficiency factor decreases. The higher the heat loss, the sooner the efficiency factor reaches zero with rising collector temperatures. However, the efficiency factor decreases faster with weaker irradiation G s levels. Thus collector sellers try to present their efficiency factor using irradiation levels of 8 W/m² to 1 W/m². These are unrealistic anywhere on the globe. Wurzburg, Germany gets only 11 % of the irradiation with 8 W/m² or more, and 13 % with less than 2 W/m²

(fig. 1). The yearly average of 397 W/m² ignores the range below 1 W/m² because it is completely irrelevant for flat plate collectors and brings only about 5 % of the yearly energy harvest for tube collectors. Otherwise the average would be even lower. Applying solar thermal energy to drive solar power electric generators is promising technology. However, transforming thermal energy into mechanical energy changes the efficiency calculation. The thermal efficiency factor measures how much heat is transferred from solar energy but says nothing about the part that could be used in a heat engine. The second law of thermodynamics and the Carnot principle puts a fundamental limit on the thermal efficiency of heat engines. The Carnot factor for a collector is: < TK > < TU > < TK > 1K η C = =. < TK > + 273 K < TK > + 273K <T K > mean collector or process temperature <T U > mean ambient outdoor temperature with <T U > = 1 C (5 ºF) 273 K (= 491 F) distance between Celsius scale and absolute zero in degree Kelvin 4 W/m² (127 BTU/ft²h) irradiation level,45,4 ηc = (<Tk>-<Tu>) / (<Tk>+273 K),35,3,25,2,15,1,5, 1 35 6 85 11 135 16 185 21 <Tu> Mean process temperature <Tk> in C Delta T = <Tk> - <Tu> fig. 11 The Carnot factor η c η c is the percentage of heat that could be transferred into power or electricity. It is about 4 % with 2 C process temperature. So even after de-rating a solar thermal system for the affect of the Carnot principle, the system efficiency matches that of current photovoltaic systems. It is easy to imagine a thermal solar system providing the energy to heat water and provide electricity. The thermal collector efficiency factor multiplied by the Carnot factor and the mean global irradiation G s results in the thermodynamic collector performance P L value depending on the process temperature <T K >. The performance value weights the achievable heat performance of a collector concerning the universal thermodynamic usability. P = η with G S = 4 W/m² (127 BTU/ft²h). L G S η C heat power performance x Carnot factor 5 45 4 35 3 25 2 15 1 5 Globl irradiation: Gs = 4 W/m² CPC vacuum tubes, optimum CPC vacuum tubes heat pipe vacuum tubes vacuum tubes, direct flow ing through double glazing flat plate large-scale flat plate average flat plate sw imming pool absorber 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 <Tu> Mean process temperature <Tk> in C Delta T = <Tk> - <Tu> fig. 12 thermodynamic efficiency or collector performance P L at an irradiation of 4 W/m² (127 BTU/ft²h) All performance value characteristics start at zero. Heat at the level of the mean ambient temperature is useless. Collectors with high η have the steepest slope. Collectors with the best thermal characteristics have the longest slope. Sometime the decrease of the collector efficiency factor will outweigh the increase of the thermodynamic efficiency factor with every collector. At the

characteristic collector temperature T C you get a maximum performance. Then the performance value decreases and reaches zero exactly together with the thermal efficiency factor because the thermal gain decreases with increasingly higher temperatures. A collector reaches its performance maximum at the characteristic collector temperature T C and a different T C results at different irradiation levels. Every collector can be used at lower temperatures than its T C, but it makes no sense to use collectors in applications that need higher temperatures than their specific T C. For example, in a domestic hot water application that must exceed 65 º C (149 ºF) to meet the anti-legionella bacteria standard, a flat plate collector would not be appropriate. The characteristic collector temperature depends on the location. The black line at 4 W/m² represents Wurzburg, Germany, this is representative of the main population centres of Europe and the North America. Mean irradiation up to 6 W/m² is possible in the Mediterranean area, up to 65 W/m² in California, up to 7 W/m² in Australia and India and even up to 75 W/m² in the Middle East. characteristic collector temperature Tc in C 16 14 12 1 8 6 4 2 2 4 6 8 Gloobal irradiation in W/m² CPC vacuum tubes, optimum CPC vacuum tubes heat pipe vacuum tubes vacuum tubes, direct flow ing through double glazing flat plate large-scale flat plate average flat plate sw imming pool absorber fig. 13 characteristic temperatures as a function of irradiation for collectors 8. The collector gain and the cardinal point The optimal orientation of a collector - south, tilted according to the latitude - is often not possible. Roof slope, building orientation and obstructions will many times prevent optimal orientation. CPC vacuum tube collectors can compensate for an unfavourable orientation with the smallest additional collector area. In an extreme case with east orientation, flat plate collectors need 9 % more area while CPC vacuum tube collectors need 4 % more. In addition, CPC collectors have higher efficiency factors at lower irradiation levels, which is common on unfavourable roof orientations. 9. Concerning the advantages of higher temperatures 9.1. General remarks In general, solar energy can be more effectively applied the higher the water temperature. Higher temperatures allow for a wider range of applications and expand the heat storage capacity of tanks. Solar cooling and thermal power generators only work with high temperatures. It is easy and cost effective to reduce water temperatures with mixing valves. On a cost per delivered kilowatt basis, CPC ETC collectors are competitive with low temperature collectors. The labour cost component per installed collector is similar for all types of collectors, but the labour cost per installed kilowatt is lower for high temperature collectors. 9.2. High collector temperatures increase the efficiency factor of the installation: If the solar system is considered the primary source of heat, conventional backup heating is avoided only if the solar outlet temperature remains above the boiler low limit point. Boiler efficiency factors are at their lowest point outside of the heating season, so every boiler cycle avoided by solar heat results in savings exponentially higher than heating season boiler cycles. If a 85% efficient oil boiler with an internal water volume of 6 l (16 gal) has to heat the system water from 2 to 7 C (68 to 158 ºF) before it can heat 15 l (4 gal) of hot water in the tank by 5 C (41 ºF), then only 16 % of the consumed fossil fuel is used for domestic water heating. Only when solar collector systems deliver water at temperatures which eliminate the need to start the boiler, will every solar kilowatt-hour save 6.25 kilowatt-hours of fossil energy.

On an annual basis, standby losses of hydronic heating systems can be as great as the annual solar energy harvest. The only way to allow backup heating systems to go dormant for extended time periods is to delivery high temperature solar water into domestic water storage or heating buffer tanks. Low temperature collectors or systems utilizing delta-t-controllers which prevent high temperatures, can never realize the benefits of backup heating systems going dormant for extended periods. Permanently high collector temperatures result in large temperature differences, which decrease the volume flow demand. This has a direct effect on the amount of electrical pump energy and pump running time. Electric energy can be cut in half by using high temperature methods. 9.3. High collector temperatures increase the storage capacity: If the temperature in the storage tank is equal to the temperature of water desired at the faucet, then the amount of usable hot water is equal to the water volume in the tank. The amount of usable hot water is greatly expanded by allowing the storage temperature to increase over the design use temperature. The tank volume is effectively enlarged by storing water higher than consumption temperatures. Consider a heating circuit with a 6 C (14 ºF) supply and a 5 C (122 ºF) return and a solar buffer tank at 9 C (194 ºF). For every litre at 9 C, 4 litres (1 gal) of water at 6 C can be fed into the heating network. A low temperature collector needs 3 times the tank volume to yield the same heat energy at 7 C (158 ºF). If the heat from the buffer tank is used through a heat exchanger (glycol system), the usable energy will be even smaller. Of course storing water at higher than consumption temperatures can result in much smaller tanks being able to deliver the same amount of hot water. It is possible for high temperature water tanks to be half the size and deliver the same amount of hot water at the faucet. 9.4. High collector temperatures allow an all-season application and provide confidence with which one can plan Every planner and user is interested in an efficient all-season application of the solar collector system. The performance of low temperature collectors drops considerably with falling outside temperatures. In winter or when the weather is not optimal, CPC collectors continue to perform at high levels. The technology is here today to utilize a single solar field for multiple purposes: domestic hot water, space heating, space cooling, or electric generation. The possibility to combine applications and realize a full solar harvest over twelve months can only be accomplished when water is store at its highest thermodynamic value. 1. Summarization Double wall evacuated tube collectors with compound parabolic mirrors have the highest thermal efficiency and achieve excellent performance in a wide range of environmental conditions. Using water as a heat transfer medium has positive cost benefits, simplifies designs, and allows direct integration into existing heating or cooling systems. Having an understanding of thermodynamic principles and thermal efficiency formulas is necessary to calculate and compare the performance of different collector designs. There are numerous advantages to harvesting solar energy at the highest possible water temperature. Design flexibility, potential to do solar cooling, thermal electric generating, and use of smaller tanks are some benefits of using the hottest water possible. Being able to hot start stagnate solar fields allows the utilization of the storage capacity of collector fields. A solar collector system that can be restarted from standstill at any time promises a much higher annual energy harvest and will allow for a reduction in collector field sizes and water storage tank sizes.

The authors Rolf Meissner, PhD, is a physicist and has worked for the German solar trendsetter company PARADIGMA since 199, as a product manager and development engineer for controllers, storage tanks and concepts for large-scale solar collector systems. In 26 he founded the department specializing in solar-thermal large-scale installations and process heat. Stefan Abrecht, M. Sc. in mechanical engineering, developed all Paradigma flat plate and vacuum tube collectors during the last 2 years as well as the collectors from the Paradigma subsidy company RitterSolar. He was also founder and first CEO of the German-Chinese joint-venture Linuo Paradigma. Paradigma Energie- und Umwelttechnik GmbH & Co. KG