Unit Commitment of Generator Sets During Dynamic Positioning Operation Based on Consequence Simulation

Similar documents
Methods for Reducing Frequency and Voltage Variations on DP Vessels

On the Development of a Classification Guide for the Dynamic Positioning (DP) System

Redundancy and Criticality Assessment (RCA) System Applied in Deep Water Operations

Control of a Microgrid in Islanded Mode

Autonomous vessels: Sensors, estimation and control

NavDP4000 Series Dynamic Positioning Systems

SECURITY ASPECTS OF MULTI AREA ECONOMIC DISPATCH WITH RENEWABLE ENERGY AND HVDC TIE LINES.

A Dynamic Framework for Real time and Regulation Markets for Smart Grids

IECRE OPERATIONAL DOCUMENT

ENHANCED SYSTEM VERIFICATION (ESV)

Economic Selection of Generators for a Wind Farm

RESEARCH ON THE VIRTUAL SYNCHRONOUS GENERATOR CONTROL STRATEGY OF GRID-CONNECTED PERMANENT-MAGNET DIRECT-DRIVEN WIND POWER SYSTEM

Closed Bus Tie Systems Why to operate a DP vessel in closed bus tie configuration? Global Maritime 2013

A Practical Approach to Managing DP Operations

INTEGRATED ELECTRIFICATION SOLUTION FOR REMOTE ISLANDS BASED ON WIND-PV HYBRID SYSTEM

Task 39: Hydrogen in Maritime Transport

Demand Dispatch and Probabilistic Wind Power Forecasting in Unit Commitment and Economic Dispatch: A Case Study of Illinois

Wind-Solar-Hydel Cogeneration Systems in Remote Areas

The HSF-Arcos research project

Fuzzy Logic Controller Based Maximum Power Point Tracking for PV panel using Boost Converter

Impact of Power Management Strategies on Micro-Grid Dynamic Performance

Wind Farms 1. Wind Farms

2016 Probabilistic Assessment. December 5, 2016 Southwest Power Pool

CERTS Microgrids. Tom Jahns Professor, University of Wisconsin-Madison. LPPC Rates Roundtable May 21, 2013

Load Frequency Control for Hybrid Microgrid using Battery Storage System

Hybrid Wind-Diesel Generation System

Fuel Cost Optimization of an Islanded Microgrid Considering Environmental Impact

NOWIcob A tool for reducing the maintenance costs of offshore wind farms

Inlet geometry effect of wave energy conversion system

Investigating Power System Primary and Secondary Reserve Interaction under High Wind Power Penetration Using Frequency Response Model

ENABLING FREQUENCY AND VOLTAGE REGULATION IN MICROGRIDS USING WIND POWER PLANTS

MECHANICS OF DRILLSTRINGS AND MARINE RISERS DON W. DAREING ASME PRESS

Artificial Neural Network Approach for Under Frequency Load Shedding

EMTP Modeling of Cogeneration System for Transient Stability Analysis

Information Document Protection System Information ID# R

Reference: Photovoltaic Systems, p. 229

Reliability Assessment of Wind-Diesel Hybrid System

RE<C: Brayton System Performance Summary

To Study the Adequacy Assessment of Chitradurga distribution substation using MCS

MULTIDIMENSIONAL OPTIMAL DROOP CONTROL FOR WIND RESOURCES IN DC MICROGRIDS

Modeling of the Dynamic Behavior of the Island Power System of Cyprus

Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25, 2012

Testability of Dynamic

4»IEEE POWER SYSTEMS .*ISK ASSESSMENT OF. Models, Methods, and Applications. Wiley. Ph.D., Fellow, IfE, CAE, EIC SECOND EDITION

Frequency Deviation Mitigate for Renewable Energy Power System in MATLAB Simulation

INTELLIGENT CONTROL SOLUTIONS FOR STEAM POWER PLANTS TO BALANCE THE FLUCTUATION OF WIND ENERGY

Control Steam Turbine Combined Cycle Power Plant Based on Soft Computing

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN

WIND TURBINES IN WEAK GRIDS CONSTRAINTS AND SOLUTIONS. J O G Tande and K Uhlen. SINTEF Energy Research, Norway SUMMARY

ISSN Vol.07,Issue.16, November-2015, Pages:

Modeling Smart Microgrids for the Developing World with Probabilistic Supply and Demand Inputs

Fuzzy Pitch Angle Control of Wind Hybrid Turbine

Impact of capacity value of renewable energy resources on RAPS system energy management

Seismic Response of a Typical Fixed Jacket-Type Offshore Platform (SPD1) under Sea Waves

Microgrid Energy Management System Using Fuzzy Logic Control

Active Power Control of Photovoltaic Power Systems

Approaches to a greener DP vessel

System Verification Helps Validate Complex Integrated Systems. American Bureau of Shipping (ABS) RELIABILITY SESSION.

Microgrids and Integration of Clean Energy

MONTE CARLO SIMULATION FOR THE SEISMIC RESPONSE ANALYSIS OF ELECTRIC POWER SYSTEM IN TAIWAN

Easy Grid Analysis Method for a central observing and controlling system in the low voltage grid for E-Mobility and Renewable Integration

PowrSym4. A Presentation by. Operation Simulation Associates, Inc. February, 2012

Electric Power Systems An Overview. Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas

STANDARD FOR CLASSIFICATION OF WIND TURBINE INSTALLATION UNITS

WIND ENERGY GENERATION

CONTINUOUS POWER-TIE CONFIGURATION

OPTIMIZATION OF STEEL CATENARY RISERS USING BIO- INSPIRED ALGORITHMS

MODELLING THE AIR/FLUE-GAS CIRCUIT OF A THERMOELECTRIC POWER PLANT UNIT

ISF Institute of Research and Education (IIRE)

NavDP4000 Series Dynamic Positioning Systems

Seismic-Resistant Switchboards Conforming to New Regulatory Standards Concerning Commercial Nuclear Reactors

HC900 Hybrid Controller When you need more than just discrete control

A study for an optimization of a hybrid renewable energy system as a part of decentralized power supply

DISTRIBUTED GENERATION AND POWER QUALITY

Resource allocation and load-shedding policies based on Markov decision processes for renewable energy generation and storage

Rules for Classification of Wind Turbine Installation Units

Reliable Power in the Offshore Drilling Industry

Modelling of a CHP System with Electrical and Thermal Storage

Statistical Scheduling of Economic Dispatch and Energy Reserves of Hybrid Power Systems with High Renewable Energy Penetration

Calculation of system index - Basic idea. Load model Alternative 2. Thermal power station model. Equivalent load. Example 6.8:

Grid Code Compliance. For India S.Balasubramoniam, Senior Consultant. 08 September September 2017 SAFER, SMARTER, GREENER

CHAPTER 5 EMISSION AND ECONOMIC DISPATCH PROBLEMS

Principles of modeling large wind parks

World Scientific Research Journal (WSRJ) ISSN: Research on Intelligent Microgrid and its Reliable Grid Connection

The strongest link. Captive power plant-smelter interface for increased power plant efficiency. Reprint from ABB Review 4/2007

A Probabilistic Security Criterion for Determination of Power Transfer Limits in a Deregulated Environment

Lecture Notes in Energy 5

DYNAMIC MODELLING AND SIMULATION OF A SIX WHEEL AUTOMATIC GUIDED VEHICLE

Fatigue crack growth for monopiles

System Integrity Protection Schemes Increasing operational security and system capacity

ANAFAS is a short-circuit calculation

1.818J/2.65J/3.564J/10.391J/11.371J/22.811J/ESD166J SUSTAINABLE ENERGY

Security Evaluation in Power Systems in Presence of Wind Generation using MCS

A Robust Optimization Model for Optimal Design of Hybrid Renewable Energy Systems

Key Technologies and Requirements for Connecting Micro-grid to Power System

Variation of Reliability Indices with Generation Techniques Applied.

Shipboard Electrical Power

Yachts. Closer to perfection.

Steady-State and Dynamic Study of Photovoltaic (PV) System in University of New Haven: Towards to a Green and Secure Campus

Calculation and Compensation of PCC Voltage Variation Using a Grid Connected Inverter of a Wind Turbine in a Weak Grid

Transcription:

Unit Commitment of Generator Sets During Dynamic Positioning Operation Based on Consequence Simulation Torstein I. Bø Tor Arne Johansen Eirik Mathiesen Center for Autonomous Marine Operations and Systems, Department of Engineering Cybernetics, Norwegian University of Science and Technology, 7491 Trondheim, Norway (e-mail: torstein.bo@itk.ntnu.no, tor.arne.johansen@itk.ntnu.no). Kongsberg Maritime AS, 3616 Kongsberg, Norway (e-mail: eirik.mathiesen@kongsberg.com) Abstract: For vessels with dynamic positioning system, diesel-electric propulsion is often used. At all time the vessel should be able to withstand any single point failure without loss of position. This paper studies the use of simulation of worst-case failure to decide which configurations of the power plant are sufficient for the current operation. The loss of position due to reduced power to the thrusters is simulated and compared with the safety requirements. This method gives both a practical approach to implement the safety requirement and information which can be used as a decision support system or for automatic start and stop of generator sets. The operational cost is also optimized by using the results from the simulations. 1. INTRODUCTION During the last decades diesel-electric propulsion has become industry standard for some types of vessels such as drilling rigs and offshore service vessels. With diesel electric propulsion, the generator sets (diesel engine connected with a generator) produce electrical power and this power is then used by the electrical propulsion units to produce thrust. The power is also used by other consumers, such as drilling drives and hotel loads. This system is highly flexible since generator sets can be started and stopped as the need for power changes, hence the diesel engines can run more efficiently. Dynamic positioning system (DP) is used to keep a vessel at a fixed position and/or heading. For vessels with dynamic positioning systems of equipment class 2 or 3, there is a requirement that any single point failure should not propagate to a loss of position (International Maritime Organization, 1994). This is mainly handled by using redundant systems, which make sure that if one subsystem fails, another subsystem is ready to take over the function or the remaining fault-free subsystems provide sufficient capacity. The number of diesel engines is important for the redundancy of diesel electric systems. The plant must be ready for any failures, such as sudden disconnection of a generator or short circuit in a switchboard. However, the highest efficiency of a typical diesel engine is achieved when it delivers 8 % of its rated power. Other problems do also arise when the utilization is low, such as soothing, extra maintenance due to extra running hours, and The authors of this paper are a part of Design to verification of control systems for safe and energy efficient vessels with hybrid power plants (D2V) and are funded by the Research Council of Norway, Kongsberg Maritime, and Det Norske Veritas (DNV). some NO X reduction systems are inefficient at low temperature (Realfsen, 29). It is therefore desired to use as few engines as possible to avoid low-load problems, but enough to still be safe. The unit commitment problem is to commit the correct units, such that the operational cost is as small as possible given the prediction of the load. The load demand of onshore power generation is very predictable and the number of generators is large (Radan, 28). A method for selecting the correct units must therefore be used, as testing all combinations is too expensive to calculate. However, for marine power plants are the number of units small, but the loads can be unpredictable. A disconnection of a generator will also give much larger impact, since the number of units is small. The focus for unit commitment of onshore power generation has mainly been to establish an efficient method to find the optimal solution, given the large set of possible solutions. A normal procedure is to use priority tables, this is a table listing the sequence in which the generators should be started (Lowery, 1966). This list can be made by simply ordering the generators by efficiency. Other approaches using optimization theory are also suggested, by among Lowery (1966); Dillon et al. (1978); Juste et al. (1999); Senjyu and Shimabukuro (23). Diesel-wind power stations on island have some of the same challenges as marine power plants. The wind speed is random, which gives a varying power production from the wind turbines and this must be compensated by the diesel generators. Contaxis and Kabouris (1991) present a method for unit commitment where ARMA models are used to predict the power generation from wind turbines. In Dokopoulos and Saramourtsis (1996), Monte Carlo simulations are used to make sure that the plant is able to

withstand faults of generators; however, the prediction of load and wind is assumed to be perfect. On marine vessels, generators are committed manually or automatically by load dependent start and stop tables (Ådnanes, 23). This is a priority table, with time and power limits for when a new generator should be started or stopped. This means that a new generator will be started if the power demand goes above a certain limit for some time. Conversely, a generator is stopped if power demand drops below another limit for a certain timespan. Radan et al. (25) optimizes the load dependent start tables with respect to fuel consumption and constrained by the safety requirement that a disconnection of a generator should not lead to blackout. Radan et al. (26) suggest algorithms to optimize the load dependent start and stop tables, based on the probability for each operational mode of the vessel. A challenge is that the safety requirement changes with different operational modes. For example, for a diving vessel safety is much more important during diving operation than during transit. Some vessels have different start/stop tables for each mode and also a minimum number of generator sets for some modes, to handle the changing requirements. Some operators choose to increase the safety margin by committing additional generator sets. The reason may be that the operator does not have enough information so that they could trust the suggestion given by the auto start/stop table. Consequence analysis is already required in DP operation with high safety requirements (Det Norske Veritas, 211). This analysis calculates if the mean thruster force and moment can be achieved after any single failure. This is a static analysis and among the typical fault cases are loss of one switchboard and loss of one engine room. The analysis will also detect a need of starting additional generator sets. 1.1 Main Contribution This article proposes a new method for unit commitment of generator sets for DP vessels. The method uses simulations to check which configurations satisfy the safety requirements. The operational cost of each configuration is then evaluated and the configuration with the lowest cost is selected. The method is a practical approach which is highly configurable with respect to different plants, safety requirements, and operational modes. The method can also be used as a decision support system by presenting the results from the simulations to the operator. 2. CONSEQUENCE BASED UNIT COMMITMENT The idea of the controller is that simulations of failure scenarios are used to check which configurations satisfy the operational requirements. This is done by simulating the response of the vessel for each configuration in the event of the worst-case failure. Then the operational cost is evaluated for each configuration. At last, the configuration which is safe and has the lowest operational cost is suggested as the best configuration. Smarter strategies for selecting test configurations can also be used, if the number CB1 DG1 CB2 DG2 CB3 DG3 CB4 BT1 BT2 BT3 BT4 DG4 DG5 Fig. 1. Single line diagram of case power plant. of configurations is large and it is too expensive to test all configurations. The load can be unpredictable; therefore a conservative load may be used in the simulation to make sure that the fault cases include the worst load-case. It is also possible to simulate multiple load cases, such that a broader span of uncertainties can be included without making the solution too conservative. Note that the optimization of operational cost should be done using the most probable prediction, and not the worst-case failure prediction. 3. CASE STUDY: DP IN STATIC CONDITIONS The D2V Case A is used in the case study. This is a drilling ship with six 9.1 MW generator sets. The vessel is simulated in DP with constant ocean current and wind forces. Only the position in surge is simulated; however, the controller can be extended to include any degree of freedom. The power plant is shown in Figure 1, it consists of three switchboards which are connected in a ring. Two generator sets are attached to each switchboard. The bus tie breakers are closed in this case study. The power consumed by the vessel is separated in two parts: DP loads: a load dependent on the thruster force. Non-DP loads: a constant load, which may include drilling and hotel loads. The non-dp loads are prioritized above the DP loads in this case setup. The DP loads will therefore be reduced first and then the non-dp loads. This priority is relevant for operation where non-dp loads are most important, this is the case for cruise vessels and drilling vessels with active heave compensators. The method also allows other priorities, such as reducing non-dp loads before DP loads. The safety requirement is that the surge position of the vessel should stay within ±5 m. 4. MODEL The DP controller is modeled as a PID controller which is saturated by the power available signal, and backcalculation is used as an anti-wind-up method. The power available signal is used to avoid blackout by limiting the amount of power used by the consumers. The power consumed by the thrusters is assumed to be given by (Johansen et al., 24): P DP = K T 2P T DP 3/2 (1) where T DP is the thruster force and K T 2P is a constant depending on the thrusters. The model for the vessel is made from the Marine Systems Simulator (Perez and Fossen, 29). The model is reduced CB5 CB6 DG6

to only include motion in surge to simplify the example case. The equation for motion in surge is therefore: mẍ = c(ẋ u c ) + T DP T wind, (2) where m is the added mass and rigid body mass of the vessel in surge, c is the linear damping coefficient, u c is the velocity of the ocean current, T DP is the thrust from DP, and T wind is the wind force. The governors of the generator sets are running in droop, with identical droop curves except when a new generator is connected and ramped in. This will make sure that the generator produces the same amount of power in per unit. The fuel consumption of each diesel engine is modeled using a Willans approximation (Guzzella and Onder, 21): F C = a + a 1 t m + a 2 t 2 m, (3) where F C is the fuel consumption, a i are constants, and t m is the mechanical torque out of the diesel engine. The typical fault which will be considered is a short circuit of one of the three switchboards. The chain of events after the short circuit is as follows: (1) At the fault time the bus tie breakers connected to the failing switchboard are opened, while all other bus tie breakers are kept closed. (2) After 2 milliseconds, the power available is reduced. The load is reduced such that each generator produces the same power as before the fault. In this study, the power will be reduced first by DP and secondly by non-dp loads. (3) The power available is then increased as a ramp with slope of 5 percent per second, up to the maximum allowed overload (11 %). (4) A new generator set is connected 45 seconds after the fault and with zero delivered power. (5) The power available and the delivered power from the new generator are ramped up with a slope of 5 percent per second. Remark 1. The power reduction is normally done by the thruster drives and other consumers and not by the DP, since the DP is too slow. However, the result of reducing the power available in this study versus demanding reduction of the load directly to the drives in a real vessel, gives the same response. The fault is modeled by disconnecting Switchboard 1. In Table 1 the configurations of interest are listed. There are also many other possible configurations, but these are chosen such that they all have a unique number of generator sets connected after the fault and the minimum amount of generator sets connected before the fault. Table 1. Number of generator sets connected to each switchboard (swbd) for each configuration. Configuration Swbd 1 Swbd 2 Swbd 3 1 1 1 2 1 1 1 3 2 2 1 4 2 2 2 In this study, only the total fuel consumption of the plant is used as cost function. It is calculated as the sum of the fuel consumption of each generator set, given by equation (3). However, it would be easy to include other cost functions, such as operational cost and startup/shutdown cost. Parameters used in the simulations are given in Appendix A. 5. SIMULATIONS 5.1 Case 1: Calm weather, high load In this case the ocean current is.1 m/s, the wind force is set to be equal the force of the current, and the power consumption from non-dp loads is set to 18 MW. The case is used to illustrate a situation where loss of power to non-dp loads is acceptable, and the weather is calm. In Figure 2 and 3 results from the simulation of the case are shown. The simulations correspond to Configuration 1 to 3. With Configuration 1, non-dp loads are reduced with 33 % until the stand-by generator set is connected and ramped up. The vessel will also drift-off 1.7 m. This configuration can therefore only be selected if this is allowed; however, the fuel consumption is reduced with 2 % compared with Configuration 2. Similarly, the fuel consumption is reduced with 8 % and extra running hours of two generator sets are avoided if Configuration 2 is chosen instead of Configuration 3. 5.2 Strong drift force, lower non-dp load In this case the current is set to 1.4 m/s, and non-dp loads to 1.4 MW. Results from this case are presented in Figure 4 and 5. It is sufficient to run with three generator sets, by choosing the optimal configuration the fuel consumption is reduced with 4 %. 6. DISCUSSION The focus of this article has been to use simulation of faults to evaluate if a configuration is sufficient. This can be used as a decision support system, for the operator to select the best configuration. However, to be an alternative to load dependent start and stop tables, a method for taking the decision to start or stop a generator must be added to the implementation. It is assumed that both power consumption from non-dp loads and environmental forces are constant. This is a good approximation as long as the weather is not too bad, since DP should only take care of drift forces. However, the power usage from drilling and other consumption can vary, for example can electrical heave compensators give large peaks for every wave crest. A method for establishing a worst-case simulation must also be made, for varying environmental forces and power consumption. There are safety requirements other than position for some vessels. For example, it may be hard to synchronize additional generator sets to the switchboard if the frequency is varying due to high load variations. It could therefore be required that enough generator sets are connected to obtain small variations of the frequency. For other vessels,

25 2 15 1 5 Number of engines: 2 3 24 18 12 6 6 5 4 3 2 1..3.6.9 1.2 1.5 Number of engines: 2..3.6.9.12.15.18..4.8.12.16 Power Available Power Total Power consumed by DP Power consumed by drilling Fig. 2. Power consumption from simulation of fault for Case 1 with different configuration of the power plant. the position may be less important, while the angles of the risers are important. However, this method can include such safety requirements by including relevant subsystems in the model. This method can be used with new upcoming technologies, such as DC-grid and battery packages. The model must however be adjusted to the actual system. Similarly, other types of blackout prevention can be used if that is desired. One of the largest benefits of this approach is that the results from the simulations can be presented to the operator such that an informed decision can be made. 7. CONCLUSION A decision support system for selecting a configuration of the power plant of a vessel is proposed. The system is based on simulations of worst-case failures; this is used to check which configurations are satisfying the safety Fig. 3. Vessel position from simulation of fault for Case 1 with different configuration of the power plant. requirements. A drilling ship in DP operation is used as a case plant to illustrate how the method works. The results from the simulations show that between 2 and 8 % fuel can be saved, in addition to fewer running hours, by choosing the optimal configuration compared with a less optimal configuration. REFERENCES Contaxis, G.C. and Kabouris, J. (1991). Short term scheduling in a wind/diesel autonomous energy system. IEEE Transactions on Power Systems, 6(3), 1161 1167. Det Norske Veritas (211). Rules for Classification of Ships. Dillon, T.S., Edwin, K.W., Kochs, H.D., and Taud, R.J. (1978). Integer programming approach to the problem of optimal unit commitment with probabilistic reserve determination. IEEE Transactions on Power Apparatus and Systems, PAS-97(6), 2154 2166. Dokopoulos, P.S. and Saramourtsis, A.C. (1996). Prediction and Evaluation of the Performance of Wind- Diesel Energy Systems. IEEE Transactions on Energy Conversion, 11(2), 385 393. Guzzella, L. and Onder, C.H. (21). Introduction to Modeling and Control of Internal Combustion Engine

3 24 18 12 6 6 5 4 3 2 1 Power Available Power Total Power consumed by DP Power consumed by drilling Fig. 4. Power consumption from simulation of fault for Case 2 with different configuration of the power plant...3.6.9 1.2 1.5..2.4.6.8 1. Systems. Springer Berlin Heidelberg, Berlin, Heidelberg, second edition. International Maritime Organization (1994). Guidelines for Vessels with Dynamic Positioning Systems. Maritime Safety Committee (MSC) Circular 645. Johansen, T.A., Fossen, T.I., and Berge, S.P. (24). Constrained Nonlinear Control Allocation With Singularity Avoidance Using Sequential Quadratic Programming. IEEE Transactions on Control Systems Technology, 12(1), 211 216. Juste, K.A., Kita, H., Tanaka, E., and Hasegawa, J. (1999). An evolutionary programming solution to the unit commitment problem. IEEE Transactions on Power Systems, 14(4), 1452 1459. Lowery, P.G. (1966). Generating unit commitment by dynamic programming. IEEE Transactions on Power Apparatus and Systems, PAS-85(5), 422 426. Perez, T. and Fossen, T.I. (29). A Matlab Toolbox for Parametric Identification of Radiation-Force Models of Ships and Offshore Structures. Modeling, Identification and Control: A Norwegian Research Bulletin, 3(1), 1 15. Radan, D. (28). Integrated control of marine electrical power systems. Doctoral thesis, monograph, Norwegian University of Science and Technology. Radan, D., Johansen, T.A., Sørensen, A.J., and Ådnanes, A.K. (25). Optimization of Load Dependent Start Tables in Marine Power Management Systems with Blackout Prevention. WSEAS Transactions on Circuits and Systems, 4(12), 1861 1866. Radan, D., Sørensen, A.J., Johansen, T.A., and Adnanes, A.K. (26). Probability based generator commitment optimization in ship power system design. WSEAS Transactions on Systems, 5(8), 191 196. Realfsen, B. (29). Reducing NOx Emission in DP2 and DP3 Operations. In Dynamic Positionong Conference. Senjyu, T. and Shimabukuro, K. (23). A fast technique for unit commitment problem by extended priority list. IEEE Transactions on Power Systems, 18(2), 882 888. Ådnanes, A.K. (23). Maritime Electrical Installations and Diesel Electric Propulsion. Oslo, Norway. Appendix A. SIMULATION PARAMETERS Parameter Value Mass + Added mass in surge 43.74 1 6 kg Linear damping 437.4 kns/m K T 2P.74 W/N 3/2 a.159 a 1.1558 a 2.255 Fig. 5. Vessel position from simulation of fault for Case 2 with different configuration of the power plant.