WOOD FLOORING WOOD FLOORING

Similar documents
TILE TILE

UPHOLSTERED WALL SYSTEM UPHOLSTERED WALL SYSTEM

SECTION INTERIOR STONE INTERIOR STONE

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

1. Division 09 Section "Rough Carpentry."

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

CARPET CARPET

End of Addendum No. 3

SECTION (06415) - PLASTIC COUNTERTOPS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION WOOD STRIP FLOORING

Kolorines Glass Mosaic Tiles Project Specification

EXECUTION REQUIREMENTS

ALL DIMENSIONS FROM FINISHED FACE OF PARTITION TO FINISHED FACE OF PARTITION UNLESS OTHERWISE NOTED.

GUIDE SPECIFICATION

GUIDE SPECIFICATION

SECTION FOUNTAINS

D. Maintenance data for resilient floor tile to include in Operating and Maintenance Manual specified in Division 1.

SECTION GYPSUM BOARD ASSEMBLIES

Student Services & Classroom Addition

B. Store products in dry spaces protected from the weather, with ambient temperatures maintained between 50 and 90 deg F (10 and 32 deg C).

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

SECTION RESILIENT TILE FLOORING. A. Section includes vinyl composition floor tile and accessories indicated and as specified.

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

Geometrik Manufacturing Inc.

DIVISION 6 SOLID SURFACE FABRICATIONS SECTION 06650

SECTION ARCHITECTURAL SPECIFICATIONS FOR INDOOR WOOD ATHLETIC FLOORING

SECTION NEW WOOD WINDOWS. 1. Section Wood Window Restoration. 2. Section Painting.

SECTION RESILIENT ATHLETIC SURFACING. B. Related Sections: Section(s) related to this section include:

SECTION RESINOUS FLOORING

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Framed Decorative Panel Systems

WorthingtonUrethane Millwork Architectural Guide Specifications

Action QuickCourt R Modular Athletic Flooring

BuildingName The Description of the Project P DOCUMENTS

SECTION STRUCTURAL REINFORCED POLYMER COMPOSITE PEDESTRIAN BRIDGE DECK

SECTION CONCRETE FORMWORK AND ACCESSORIES

Construction Standards PAGE

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

SECTION IMPACT RESISTANT WALL PROTECTION

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

SECTION RESILIENT SHEET FLOORING

DIVISION VIII - DOORS AND WINDOWS

A. Access doors and frames are part of an access door and frame allowance.

Melton Classics, Inc. Architectural Urethane TM SIMULATED WOOD TRIM SECTION 06455

Corium Brick Rainscreen System Specifications

Student Services & Classroom Addition

SECTION (09620) - RESILIENT ATHLETIC FLOORING

SECTION TILE CARPETING

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Glenlake Modular Railing System

SECTION CERAMIC and QUARRY TILE

SECTION RESILIENT BASE AND ACCESSORIES

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System

Section SoundPly RF M25 Acoustic Wall Panels

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

A. Meet at Project site <insert number> days before starting installation.

Key Features. Glass Locker Series GL5000. ¼ inch tempered glass doors with soft closing hinges. Back-painted glass can be matched to any Pantone color

SECTION ROUGH CARPENTRY. B. AWPA (American Wood Preservers Association) Book of Standards. C. WCLIB (West Coast Lumber Inspection Bureau)

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

SECTION BRICK FLOORING

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Monaco tm Modular Railing System

SECTION DOOR HARDWARE

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

TerraClad TM General Specifications

Marlite Guide Specification 2/24/2017 Surface Systems - MAP375 System SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

SECTION METAL WALL PANELS

EPOXY TERRAZZO 1 REV. 8/02

ARCHITECTURAL GUIDE SPECIFICATIONS

SECTION RESILIENT TILE FLOORING

SECTION EXTERIOR GRILLS AND SCREENS

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

SECTION RESILIENT FLOORING ACCESSORIES

SUBSTITUTION REQUEST (After the Bidding/Negotiating Phase)

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

COMPOSITESIDING

***************************************************************** ** NOTE TO SPECIFIER **

DIMENSIONAL LETTER SIGNAGE

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

First Class Building Products, Inc.

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION EXPANSION CONTROL

Section SoundPly LR M25 Acoustic Ceiling Panels

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

SECTION WOOD FLOORING SYSTEM

Trex Commercial Products page Decorative Metal Railing

DIVISION 03 CONCRETE SPECIFICATION : FORMS AND FORMWORK

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

SECTION TERRAZZO FLOOR TILE

SECTION MORTAR

SECTION STAINLESS STEEL WALL PANELS

SECTION QUARRY TILE

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION EXPANSION CONTROL

A. The work under this section consists of furnishing and installing gauge steel framing and bracing as indicated on the drawings and as specified.

Transcription:

09550 - WOOD FLOORING 09550-1 PART ONE: GENERAL 1.1 Description WOOD FLOORING 1.1.1 Work in this Section, as shown or specified, shall be provided by the Interior Contractor and shall be in accordance with the requirements of the Contract Documents. 1.1.2 Work in this section includes all labor, materials, equipment, and services necessary to complete the Wood Flooring as shown on the drawings and specified herein, including, but not limited to, the following: a. Moisture protection above substrate. b. Furnishing, cutting, fabricating, delivery, and setting of all Wood Flooring, molding and/or base. c. Substructure as required by manufacturer. d. All fastening devices and accessories necessary for complete installation. e. Shop Drawings and samples for work of this Section. 1.1.3 Related work in other sections: a. Interior Stone Section 04401. b. Stone Flooring Section 09600. c. Millwork Section 06410. d. Finish Carpentry Section 06200. e. Carpet Section 09680. 1.2 Submittals 1.2.1 All submittals shall be made according to Section

09550 - WOOD FLOORING 09550-2 01300 and as specified herein. 1.2.2 Submit the following to the Consultant for approval prior to construction and fabrication. a. Shop Drawings, indicating fabrication and then installation methods, to include plans at not less than 1/2" = 1'-0" (or 1:20) scale and details at not less than 3" = 1'-0" (1:5) scale. Indicate required field dimensions, materials, finishes, substructure, all fastening devices and accessory items. Include coordination details for related and adjoining work. b. Two (2) sample panels, approximately 18" x 18" (450 x 450 mm), mounted on hardboard back-up of each species of wood, cut, pattern and finish specified. Samples shall be representative of the expected range of variation in wood and finish. Samples shall be fire retardant treated wood where such has been specified. c. Two (2) samples of each trim and base in finish specified. Each shall be full member width and thickness and approximately 18" (450 mm) long. 1.3 Documentation 1.3.1. The drawings and specifications are an outline of the criteria and performance requirements of the work. The requirements shown by the details are intended to establish basic dimensions and profiles of members. Within these parameters, the Interior Contractor is responsible for the design and engineering of the floor and support system, including whatever modifications or additions may be required to meet the specified requirements and maintain the visual design concept. 1.3.2 It is recognized that the design details do not cover every condition. It is intended that any conditions not detailed shall be developed through the Interior Contractor's Shop drawings in compliance with performance criteria, as indicated for detailed areas and stipulated in these specifications.

09550 - WOOD FLOORING 09550-3 1.4 Quality Assurance 1.4.1 All Wood Flooring and trim shall be installed using experienced, skilled workmen to the highest standard of workmanship. The finished appearance of the floor shall be free from warping, swelling, cracking, or any other defects due to faulty workmanship. 1.4.2 All work and materials shall conform to the drawings and specifications; any changes or deviations in materials or methods must be approved by the Consultant. 1.4.3 Materials used in fabrication of this work shall be new and the best grade obtainable of their respective types. 1.4.4 Obtain flooring materials from only Manufacturers who will, when requested, send a qualified technical representative to the project site to advise the Installer of proper installation procedures. 1.4.5 The Interior Contractor shall be responsible for taking accurate job site measurements for all dimensions related to the Work. 1.4.6 The Interior Contractor shall examine all conditions pertaining to the installation of Wood Flooring and shall provide all coordination as required to achieve the proper and timely completion of the installation. 1.4.7 The Interior Contractor will not change brands of materials during the course of the Work, unless approved by Consultant. 1.5 Codes and Standards 1.5.1 Wood floor and substructure shall meet requirements of, and all work shall be performed in accordance with, the applicable local and state Building Codes, or the requirements of this Specification, whichever are more stringent. Comply with all laws, ordinances, rules and regulations and orders of any public authority having jurisdiction over this part of the work.

09550 - WOOD FLOORING 09550-4 1.5.2 Interior Contractor shall be responsible for securing approval when required from the State Fire Marshall on all materials to be used. A letter from the Fire Marshall's office shall be sent to the Owner indicating such approval where required. 1.5.3 Wood Flooring and installation system shall conform to, but not be limited to the following codes and standards: a. Architectural Woodwork Institute (A.W.I.) b. American National Standards Institute (ANSI) c. American Society for Testing and Materials (A.S.T.M.) 1.6 Product Handling 1.6.1 Use all means necessary to protect the materials of this Section before, during and after installation and to protect the work and materials of all other trades. 1.6.2 In the event of damage, immediately make all repairs and replacements needed to the approval of the Consultant and at no additional cost to the Owner. 1.7 Guarantee 1.7.1 Interior Contractor shall provide a written guarantee stating that the Wood Flooring has been installed in accordance with all Manufacturer's recommendations and directions. Unless stated otherwise in these Specifications, guarantee shall also state that all work is in accord with drawings and Specifications, as amended by any changes thereto authorized by the Consultant, free from defects in materials and workmanship for a period of five (5) years from the date of acceptance of the work by the Owner. Interior Contractor shall agree to repair or replace defective materials and workmanship during the guarantee period at no additional cost to the Owner. PART TWO: PRODUCTS 2.1 Products

09550 - WOOD FLOORING 09550-5 2.1.1 Wood Flooring shall be in the wood species, cut, pattern and finish as shown by the Manufacturers and the drawings and specified herein, or an approved equal (See Section 0100). 2.1.2 Substructure of Wood Flooring shall be constructed of materials and methods as recommended by Wood Floor Manufacturer. 2.1.3 Trim, base and accessories shall be provided as required for complete installation as specified herein, on drawings, and as recommended by Manufacturer. PART THREE: EXECUTION 3.1 Inspection 3.1.1 It is the responsibility of the Interior Contractor to see that the floor surface is properly prepared to receive Wood Flooring as specified. 3.1.2 Review installation procedures and coordination with other work, and with other Subcontractors whose work will be affected by the Wood Flooring. 3.1.3 Advise General Contractor of requirements relating to his placement of any inserts which are to be used for anchoring and supporting Wood Flooring. 3.2 Conditions of Surfaces 3.2.1 Allowable variations in substrate levels shall be as recommended by Flooring Manufacturer or as follows, whichever is more stringent: a. Floors: Plus/minus 1/8" (3 mm) in 10'-0" (3 M) distance and 1/4" (6 mm) total maximum variation from levels shown. 3.2.2 Grind or fill concrete and masonry substrates as required to comply with allowable variations. 3.3 Preparation

09550 - WOOD FLOORING 09550-6 3.3.1 Treat each concrete substrate as may be required to remove curing compounds or other substances that would interfere with proper installation of Wood Floor. Clean substrate of all traces of such treatment. 3.3.2 Perform moisture tests on concrete slabs to determine that concrete surfaces are sufficiently cured and are ready to receive installation. 3.3.3 Provide moisture protection above substrate as recommended by Wood Flooring Manufacturer. 3.4 Allowable Tolerances 3.4.1 Allowable variations in finished work: Do not exceed the following deviations from level and plumb, and from elevations, locations, slopes and alignment shown. a. Floors: 1/8" (3 mm) in 10'-0" (3 M) run, any direction; 1/32" (1 mm) offset at any location. 3.5 Installation 3.5.1 Install Wood Floor only after all masonry, plastering, tile, marble and terrazzo work has been completed and permanent heating system is operating. Moisture content of concrete slabs, building air temperature and relative humidity must be maintained within limits recommended by Wood Flooring Manufacturer. 3.5.2 The construction and preparation of the subfloors shall be in strict accordance with the Manufacturer's recommendations. The installation procedure of the Wood Floors to be laid thereon shall conform in all respects to the laying instructions of the Manufacturer. Extend Wood Floor into toe spaces, door reveals, and into closets and similar openings. 3.5.3 Maintain reference markers, holes, or openings that are in place or plainly marked for future cutting by repeating on the finished floor as marked in the subfloor. Use non-permanent marking devices. 3.5.4 Unless otherwise specified, lay flooring from center marks established with principle walls, discounting

09550 - WOOD FLOORING 09550-7 minor off-sets, so that pattern of Wood Floor is centered in room. Lay wood floor pattern square to room axis, unless otherwise shown on drawings or specifications. 3.5.5 All trim and bases provided as required for complete installation herein shall be installed according to Manufacturer's recommendations. 3.5.6 Finishing shall be in accordance with the approved finish samples and in accordance to Manufacturer's instructions. 3.6 Cleaning and Protection 3.6.1 Unless otherwise specified, upon completion the floors shall be cleaned, waxed, buffed and polished using materials as recommended by the Manufacturer. 3.6.2 After installation and cleaning, protect Wood Floor from stain, damage subsequent construction activities. 3.6.3 Protect all Wood Floors from other material that will cause stain. 3.6.4 At completion of construction work, remove all temporary protection from the work of this Section. 3.6.5 Examine all work and repair all damage. Clean soiled or stained surfaces. In the event damage is irreparable or soiled or stained surface cannot be cleaned, then remove and replace such items at not additional cost. END OF SECTION