RESILIENT FLOORING: Select Step Wood

Similar documents
RESILIENT FLOORING: Hot and Heavy - Secoya

UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

CONDUCTIVE RESILIENT FLOORING

Section RESILIENT TILE FLOORING INCLUDING VINYL COMPOSITION TILE

CONDUCTIVE RESILIENT FLOORING

Section RESILIENT TILE FLOORING INCLUDING SOLID VINYL FLOOR TILE

Section STATIC DISSIPATIVE RESILIENT FLOORING

Section RESILIENT TILE FLOORING INCLUDING ECONATURALS RUBBER FLOOR TILE

Section RESILIENT SAFE-T VINYL SHEET FLOORING

LINOLEUM SHEET FLOORING

RESILIENT PHOTOLUMINESCENT STAIR TREADS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION RESILIENT TILE FLOORING. A. Section includes vinyl composition floor tile and accessories indicated and as specified.

RESILIENT ECO NATURALS, DEFIANT, AND PHOTOLUMINESCENT STAIR TREADS

Ecore Athletic Elevate BOUNCE 2 GUIDE SPECIFICATIONS Ecore

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

CSI Exceed PART 1.0 GENERAL. plae.us SUMMARY 1.2 REFERENCES

ECOfit Rolls GUIDE SPECIFICATIONS ECORE Commercial Flooring

RESILIENT ACCESSORIES

Performance Rolls GUIDE SPECIFICATIONS Manufactured in the U.S.A. by:

Division 9 Resilient Athletic Flooring

ARCHITECTURAL GUIDE SPECIFICATIONS

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

1.02 RELATED REQUIREMENTS NOTE:

1.02 RELATED REQUIREMENTS NOTE:

SECTION RESILIENT TILE FLOORING

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

ARDEX GUIDE SPECIFICATION ARDEX GPS GENERAL PATCH & SKIMCOAT Trowelable underlayment

FOREST RX / TERRAIN RX GUIDE SPECIFICATIONS ECORE COMMERCIAL FLOORING

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

1. Amarco Products Athletic Recycled Rubber Sports Flooring Rolls and Interlocking Tiles 2. Adhesives

SECTION TERRAZZO FLOOR TILE

Powerdek Fleck. SECTION Resilient Athletic Flooring

SECTION Resilient Athletic Flooring

Training Ground with Nike Grind RubberX GUIDE SPECIFICATIONS Ecore

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs.

MARATHON & MARATHON PLUS RUBBER TILE

ECOfit Rolls GUIDE SPECIFICATIONS Ecore Commercial Flooring

SECTION (09620) - RESILIENT ATHLETIC FLOORING

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

Control XT SECTION Resilient Athletic Flooring

Installation Instructions Vinyl Glue Down Flooring - Pro

Fastrack Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Centaur

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

Ecore Athletic Stacked Performance Collection Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Ecore

LVP GLUE DOWN INSTALLATION GUIDE PAGE 1 of 6

ARDEX GUIDE SPECIFICATION ARDEX FEATHER FINISH Self-Drying, Cement-Based Finish Underlayment

Vinyl Rx GUIDE SPECIFICATIONS Ecore Commercial

Pinnacle 2 Carpet Tile GUIDE SPECIFICATIONS Ecore

RESILIENT RUBBER STAIR TREADS WITH RISER

ARDEX GUIDE SPECIFICATION ARDEX SD-M Designer Floor Finish

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

SECTION Resilient Athletic Flooring

American Guild Vinyl Flooring - Steadcrest Collection Installation Instructions

Installation Guide LVP Glue Down

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Products

SECTION RESINOUS FLOORING

KOSTER AMERICAN CORPORATION

ARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors

1.1 DESCRIPTION OF WORK A. Provide new resilient flooring and base where noted on drawings.

SECTION RESILIENT STAIR TREADS CSI 3-PART SHORT-FORM GUIDE SPECIFICATION USE FOR OUTLINE OR DD SPECIFICATION ISSUES. EDIT TO SUIT PROJECT

SECTION RESILIENT FLOORING ACCESSORIES

SECTION WOOD STRIP FLOORING

SECTION SUBSURFACE PREPARATION FOR FLOOR FINISHES

GUIDE SPECIFICATION

LOOSE LAY INSTALLATION GUIDE PAGE 1 of 6

IVC US. Light Commercial Installation Guide - Sheet Vinyl. Leading the Way

D. Maintenance data for resilient floor tile to include in Operating and Maintenance Manual specified in Division 1.

Tennant Company October North Lilac Drive Minneapolis, Minnesota Guide Specification

ARDEX GUIDE SPECIFICATION ARDEX K 60 ARDITEX A Rapid Setting Latex Smoothing and Leveling Compound

Advance NG (6mm) Technical Specification Sheet

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8

SECTION HYDRAULIC CEMENT UNDERLAYMENT

ECORE Athletic Stacked Ultimate Turf Rolls GUIDE SPECIFICATIONS ECORE International

SECTION Rubber Tile Flooring

Specification and Installation

Overall Thickness Wear Layer Thickness. Factory in. (2.0 mm) in. (2.0 mm) Diamond 10 Technology coatingcultured

GUIDE SPECIFICATION

A. Description of Work: Work of this section includes self leveling underlayment for interior finish flooring but is not limited to, the following:

PART 1 GENERAL RESILIENT SHEET FLOORING

MondoArmor (18mm) Technical Specification Sheet

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

CONNOR Control XT Page 1

822 In the Bluff Cover: 988 Sophisticate, 867 Sail Boat

Ecore Athletic Elevate Roster Interlocking Carpet Tile GUIDE SPECIFICATIONS Ecore

Kolorines Glass Mosaic Tiles Project Specification

Action Herculan TC Club Synthetic Tennis Surfacing System

ECOrx GUIDE SPECIFICATIONS Ecore

NEW HARMONI (3mm) Technical Specification Sheet

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

ARDEX GUIDE SPECIFICATION ARDEX K 521 Self-Leveling Concrete Topping with Aggregate Surface

A. Drawings and general provisions of the Contract apply to this Section including all documentation provided in RFP#

SECTION HYDRAULIC CEMENT UNDERLAYMENT

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX ARDIFLO Pump System Underlayments

CONNOR PowerDek Page 1

Sport Impact (10mm) Technical Specification Sheet

GUIDE SPECIFICATIONS IN CSI FORMAT: RESILIENT FLOORING

ARDEX GUIDE SPECIFICATION ARDEX K 22 F High Flow, Fiber Reinforced, Self-Leveling Underlayment

Transcription:

160 S. Industrial Blvd Calhoun, GA 30701 Section 096519 RESILIENT FLOORING: Select Step Wood This document is intended as a suggested guide for editing your architectural guide specification. Mohawk Group will not be held liable for damages arising out of the use of any information or specifications found in this document. Make sure you have the latest publication for this specification. Product selection and accuracy of all project specifications are the specifier s or designer s responsibility. PART 1 GENERAL INFORMATION 1.1 SECTION INCLUDES A. This section deals with resilient flooring found in the drawings and schedules of the contract that meet the requirements of this section. B. Related Documents: Drawings and general provisions of the contract apply to the work of this section. 1.2 RELATED SECTIONS Note to Specifier: Delete any sections below not relevant to this project and add others as required. A. Division 3 Concrete: not covered in this section. B. Division 6 Wood and plastic: not covered in this section. C. Division 7 Thermal and humidity protection: not covered in this section. D. Division 9 Other sections containing information related to floor finishes: not covered in this section. 1.3 REFERENCES (INDUSTRY STANDARDS) A. ASTM F 710: Practice for Preparing Concrete Floors to Receive Resilient Flooring. B. ASTM E 648: Test Method for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy C. ASTM E 662: Test Method for Specific Optical Density of Smoke Generated by Solid Materials. D. ASTM F 1869: Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride. E. ASTMF 1700: Standard Specification for Solid Vinyl Tile F. ASTM 2055: Standard Test Method for Determining Size and Squareness of Resilient Floor Tile by Dial Gauge Method G. ASTM F386: Standard Test Method for Thickness of Resilient Flooring Materials Having Flat Surfaces H. ASTM 2199: Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat I. ASTM 970: Standard Test for Static Load Limit J. ASTM 1914: Standard Test Method for Short-Term Indentation and Residual Indentation of Resilient Floor Covering K. ASTM D2047: Standard Test Method for Static Coefficient of Friction of Polish-Coated Floor Surfaces as Measured by the James Machine Page 1 of 5 6063-M (2016-3-21)

L. ASTM F925: Standard Test Method for Resistance to Chemicals of Resilient Flooring M. ASTM F137: Standard Test Method for Flexibility of Resilient Flooring Materials with Cylindrical Mandrel Apparatus N. ASTM F1515: Standard Test Method for Measuring Light Stability of Resilient Flooring by Color Change O. ASTM F1514: Standard Test Method for Measuring Heat Stability of Resilient Flooring by Color Change 1.4 SUBMITTALS A. Provide the product s Technical Specifications data sheet as well as all Installation and Maintenance Instructions. B. When required, supply floor drawings and installation plans. C. Supply a set of samples measuring at least 3 (7.5 cm) by 6 (15 cm) of the complete range of colors and finishes chosen for the project. D. When required, provide Mohawk Group s attestation, certified by an independent laboratory, confirming that the flooring complies with the fire standards of the following tests: 1. ASTM E 648; Critical Radiant Flux: 0.45 watts/cm 2 or more 2. ASTM E 662; Smoke Density: 450 or less E. Provide Mohawk Group s Warranty Certificate. 1.5 QUALITY ASSURANCE A. Installer Qualifications: Installer experienced in installation or application of systems similar in complexity to those required for this project, including specific requirements indicated. B. In accordance with the technical instructions in the Installation Instructions, use all the accessories recommended by Mohawk Group when installing its flooring. NOTE TO SPECIFIER: Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how you might specify a mock-up on a large project. C. Mock-up: Provide a mock-up for evaluation of surface preparation technique, application workmanship and requirements for expansion control. Do not proceed with remaining work until workmanship, color, sheen and finished appearance are approved by architect. D. Follow the instructions specified in the most recent version of Mohawk Group s Installation Instructions. 1.6 DELIVERY, HANDLING, STORAGE A. Deliver the flooring to the installation site in Mohawk Group s original packaging. Indicate the project name and handling instructions on the outside of the boxes. B. Advise the carrier of any damaged material and indicate it on the packing slip. C. Store materials in a flat in a dry, warm, ventilated and weather tight location. Protect flooring products from damage. D. Install the flooring after all other finishing work, including painting, have been completed. 1.7 PROJECT CONDITIONS A. Store the flooring inside, sheltered from extreme hot or cold temperatures. Place the material on a smooth level floor or where there is uniform solid support in a clean, dry well-ventilated area. Unstack the pallets. The long-term storage temperature must be maintained between 65 F (18 C) and 85 F (29 C). Protect adhesive and flooring material from freezing, extreme heat and direct sun exposure. B. Acclimatize the subfloor, all flooring material and adhesive for 48 hours before, during and after the installation by maintaining the room temperature between 65 F (18 C) and 85 F (29 C). The pallets should be unstacked 24 hours prior to use. Page 2 of 5 6063-M (2016-3-21)

C. Afterwards, maintain the room temperature between 55 F (13 C) and 90 F (32 C). Protect the material from direct sources of heat such as air vents and other types of heaters. D. Do not install on cement slabs unless they are thoroughly cleaned, level, structurally sound and free from paint, varnish, adhesive, oil, grease, solvent, sealer and curing compounds or other foreign substances that may adversely affect adhesion. PART 2 - PRODUCTS 2.1 MANUFACTURER A. COMPANY Mohawk Group 160 South Industrial Blvd. Calhoun, GA 30701 Telephone: 800-554-6637 Fax: 877-244-8054 Website: www.mohawkgroup.com B. Manufacturer must have a headquarters in the United States of America. C. Alternates shall be in the manufacturer s running line. No special runs, customs or special constructions will be accepted. 2.2 RESILIENT FLOORING DESCRIPTION A. Characteristics: 1. Luxury Vinyl Tile: Select Step Wood 2. Gauge: 3 mm (.118 in) 3. Colors and Sizes: 8 colors of 6 x 48 (152mm x 1219.2mm); 6 colors of 7.25 x 48 (184.2mm x 1219.2mm) 4. Wear layer: 20 mil (0.5mm) 5. Complies with ASTM F 1700, Class III, Type B (Embossed) 6. Refer to the product s Technical Specifications data sheet for detailed specifications. 7. Choose from any of the Mohawk Group s complete line of colors (indicate the item number). 8. All products are FloorScore certified. 9. This product is manufactured in a factory that has ISO 9002 and ISO 14001 certifications. 10. Product must be 100% virgin vinyl and contain at least 8% bio-base renewable material. 11. Product must have an enhanced urethane wear layer. 2.3 ADHESIVES A. Use of Mohawk Group s M700 Pressure Sensitive, M95.0 Acrylic or MS160 Spray adhesive is required. M700 covers 220-260 sf/gallon and M95.0 covers 175-225 sf/gallon when applied with the recommended notched trowel. MS160 covers 145-160 sf/22 oz can. 2.4 OTHER MATERIAL A. Subfloor repairs: Use a good-quality Portland-based patching compound modified with latex that has a minimal resistance to compression of 3,500 lbs/sq. in. (246 kg/cm 2 ) to fill, smooth or level subfloor imperfections. B. Self-levelling underlayment: Use a Portland-based self-levelling underlayment modified with a polymer that has a minimal resistance to compression of 3,500 lbs/sq. in. (246 kg/cm 2 ) Page 3 of 5 6063-M (2016-3-21)

PART 3 EXECUTION 3.1 SITE INSPECTION A. Examine the subfloor before installation to ensure that the surface is clean, dry, smooth, structurally sound and free from foreign substances that may adversely affect adhesion or cause discoloration. Furthermore, ensure that the subfloor is free of paint, varnish, adhesive, oil, grease, solvent and other foreign substances, including treatment compounds, sealers and curing compounds that may adversely affect adhesion or alter the appearance or durability of the vinyl flooring. B. Verify the surface to ensure there is no powder, scaling or mold. If there is, remove it with a mechanical sander and level with a good-quality cement-based Portland primer. C. Never remove residual or other adhesive with chemical adhesive removal products; their use will automatically void the Mohawk product warranty. D. Report and rectify all unsatisfactory conditions. Do not start flooring installation until all rectifications have been completed. 3.2 SUBFLOOR PREPARATION A. All subfloors should be smooth, flat and dust free with the tolerance not exceeding more than 1/8 in a 10 span. All subfloor and underlayment patching must be performed with a non-shrinking, water-resistant Portland cement patching compound. B. Mechanically remove all surface contaminants such as paint, oil, grease, varnish, adhesive as well as various other products such as treatment compounds. C. Measure the humidity and ph levels in the cement in compliance with the following standards before installation: 1. ASTM F 1869, Anhydrous Calcium Chloride test for moisture levels. The maximum allowable reading for M700 adhesive is 5 lbs/1,000 sq. ft./24 hours (2.26 kg/92.9 sq. m/24 hours). 2. ASTM F 2170, Relative Humidity (RH) test using in situ probes. The maximum allowable reading is: a. 85% RH for M700 Adhesive b. 95% RH for M95.0 Adhesive c. 93% RH for the MS160 Spray Adhesive 3. ASTM F 710, ph levels (test procedure 5.3.1). The readings should be between 8 and 9. The ASTM test frequency recommendation is 3 measures for the first 1,000 sq. ft. (92.9 sq. m) and one measure for each additional 1,000 sq. ft. (92.9 sq. m). D. Ensure Moisture, Relative Humidity and ph tests have all been conducted and measurements meet Mohawk Group s recommendations. E. In case of doubt, test the adhesion on the cement subfloor or other surface that will be covered by the flooring. Do the test using the specified flooring and recommended adhesive. 3.3 RESILIENT FLOORING INSTALLATION A. Install the flooring according to the latest version of Mohawk Group s Installation Instructions. Use the tools, adhesives, trowel types and procedures recommended in the instructions. B. Acclimatize the subfloor, all flooring material and adhesive for 48 hours before and during the installation by maintaining the room temperature between 65 F (18 C) and 85 F (29 C). Afterwards, maintain the temperature between 55 F (13 C) and 90 F (32 C). 3.4 CLEANING AND PROTECTION A. Remove all excess adhesive immediately after installation as recommended in Mohawk Group s Installation Instructions. Page 4 of 5 6063-M (2016-3-21)

B. Before allowing traffic after installation, consult and follow the recommendations in Mohawk Group s Installation Instructions. C. Following installation and cleanup, if the work of all other trades has not yet been completed, protect the flooring by laying sheets of non-staining brown Kraft paper, and then a layer of plywood sheets (rolls of nonstaining heavy cardboard material could also be used for protection). D. Follow the instructions in Mohawk Group s Maintenance Instructions when performing initial and regular maintenance procedures. END OF SECTION 096519 Please note that technical web site documents prevail. Page 5 of 5 6063-M (2016-3-21)