ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

Similar documents
ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

automatic regulation of mixture richness way to emission decrease is in standard equipment of CHP unit

INdoor MGM 200 Natural Gas - emissions NOx < 500 5%O2. Type Specifications Co-generation Unit with MAN Gas Engine

UFL Micro Biogas CHPs

TECHNICAL DETAILS INDOP220MB

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

WHAT S INSIDE 11 TECHNICAL INFORMATION 18 HYDRAULIC PRINCIPLE DRAWINGS 20 BUFFER VESSELS 23 TECHNICAL SUPPORT 23 DECLARATION OF COMPLIANCE

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

PowerBloc EG. Technical Information and Installation Manual Output range 43 to 532 kwe. Combined Heat and Power

UltraGas. Technical Data Output range 15 to 2000 kw. Condensing Gas Boiler /02-07/15 Subject to modifications

TOTEM. Cogeneration (CHP) Range. TECHNICAL SUBMITTAL TR r2. Highest total efficiency with modulating output and lowest NO X emissions available

b) General instructions and documents to be submitted by an interested company:

ABB MEASUREMENT & ANALYTICS DATA SHEET. SCK Sampling system for dry gas sampling at rotary cement kiln gas exit and calciner gas exit

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Combustion Laboratory Unit C492

Online data sheet MAC800 CUSTOMIZED ANALYZER SYSTEMS

EUROPE S LEADING CHP SPECIALIST. Dachs CHP RANGE GUIDE 2016

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

MODULATING CONDENSING BOILER WITH LOW NOX PREMIX BURNER FOR OUTDOOR INSTALLATION (IPX5D) OUTPUT RANGE from 99.5 to 920 kw in battery (115kW x8)

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

GET Turbine Generator

BUILDINGS & OFFICE SPACES INDUSTRIAL SOLUTIONS. Combined production of Heat and Power. Waste Heat Recovery Bottoming Cycle

Air Cooler Industry AC-MS Modular Systems

Largo & Allegro. Air Compressors. Largo & Allegro

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

2G. Product portfolio.

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

PRODUCT DESCRIPTION PARAMETERS

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

do more with less Mini-Cogeneration Your declaration of independance : generate your own power and heat efficiently

HITACHI Modular Chiller Solutions

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

Combustion Laboratory Unit C492

Thai-German Technology Conference Biogas CHP Solutions / exhaust gas heat recovery - GTP Solutions GmbH (D) Bangkok, Hotel Crowne Plaza

oil cleaner Electrostatic Product brochure

CONTINUOUS GAS POWER GENERATION

YANMAR s 35 kw Combined Heat and Power System.

Ion exchange Unit IXU 1/4 Series

A LTERNATIVE E NERGY D IVISION HIGH PERFORMANCE COGENERATION SYSTEMS FOR AGRICULTURE AND INDUSTRY

Renewable energies Concepts Heat exchanger solutions. Experts for energy recovery. We make waste-heat to your profit

Choose TOTEM, smart heat and power

Stack Parking Surface Mounted Stackers

Reducing running costs, whilst benefiting the environment and the future

madur GA21p-EN-v portable gas analyser

DRY COOLERS CERTIFY ALL DRY COOLERS

Hydraulic systems Quality without cutting corners

AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH

FLUIDISTOR GAS FLOWMETER GD 100 (EX)

Low Temperature Check. Automatic instrument for the determination for both TR TEST and BRITTLENESS POINT

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Gitie. A CHOICE SMARTER than solar systems. Trivalent integrated outdoor package

Report on thermal cooling system implementation and performance

CCR3 Controller - return temperature controller & temperature registration

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

PAHT C pumps ATEX PAHT C pump

Siemens gas engine portfolio siemens.com/engines

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

ELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Aqua-Recycling-Control 80B Plus

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

EuroFID Total Hydrocarbon Analyzer

Forward-looking and energy efficient Biomass heating

Compact flue gas analyser: testo 300 M-I

SOLAHART COMMERCIAL SOLAR WATER HEATING FLEXIBLE SOLUTIONS

Product range. Product range

General Plan OXYGEN SERVICE CONTAINER 2005 Version 1.02

TEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Servo-hydraulic Universal Testing Machine HUT Type B

Stationary Gas Analysis System Goliath for bio methane, landfill gas, sewage gas, mine gas and biogas

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

EQUIPMENT APPEARANCE. madur. portable gas analyser

FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS

QGO Oxygen Sensor. Building Technologies HVAC Products

DOSING SYSTEMS FOR SWIMMING POOLS

MCW 5-39 kw. Indoor monobloc unit. Water chillers and heat pumps MCW PLUS. Compact single circuit units. 242 galletti.

Model FDL 115 Safety drying chambers for limited quantities of solvent

Reliable, low-maintenance process heating

Nilan VPL Active heat recovery and cooling (air/air)

Spirax EasiHeat TM HTG (Steam Side Control) EN Heating System Compact Heat Transfer Solution

OIL-INJECTED ROTARY SCREW COMPRESSORS. G ( kw / hp) / G VSD ( kw / hp)

Heated FID OVF Portable THC/TVOC Analyzer

Pump down time for 5 l receiver

CONDENSING BOILERS EX3 & 6. Floor Standing Gas Fired. Condensing Boilers. Condensing 69kW 542kW. Cascading options up to 8,672kW

Air Cooler Industry OSCA / OSCAF 0-3

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

RHA TECNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

GLAC BD2. Lufttechnik. GEA Heat Exchangers / HVAC Systems

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics

PlastCoat PC 25/ PC 35

Transcription:

CHP Technical Data Sheet for T200 Natural Gas Containerised Cento Series Standard Features High performance electrical efficiency Fully modulating output 3 packages Open frame, Indoor Canopy, Outdoor Container Sophisticated web remote monitoring Bosch engine management The Cento series benefits from having Tedom s own built in-house high performance gas engines. Available to run on a variety of gas fuels. Multiple units can be run in synch, and high-end digital controllers make synchronising with the mains simple. Long service intervals 27 month warranty Standby power options Low noise options ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY 200 kwe 237 kwt 39.2 % 46.4 % 85.6 % shentongroup has the exclusive distributorship for Tedom products in the UK, Ireland and Channel Islands. We provide dedicated services for CHP projects, ranging from design assistance, through project management, to commissioning and long-life support. Tedom is a global CHP manufacturer with 600 employees. There are over 2,000 Tedom CHP units in service in over 35 countries worldwide.

Cento Series Features The TEDOM Cento series of CHP units are machines of medium outputs, using gas engines, which originate from automotive engines. They form the performance series within a range of outputs from 80 to 200 kw. The CHP unit s arrangement is in container design, which contains engine-generator set, complete heat installation, plus an exhaust silencer, and electric switchboard with power and control parts. It is intended for natural gas operation, and for outdoor installation. TEDOM CHP Unit Merits: Automatic air-fuel ratio control - this method of reducing emissions is in the standard supply of CHP unit. CHP units are fitted with BOSCH engine-management which optimises engine operation. CHP units form easily connect-able compact complex. By use of containerised enclosure, CHP units are characterized by low noise output and are protected against external conditions. Ability to adapt to different temperature gradients of heating systems. Due to modular conception of control system, the number of binary and analogue inlets for monitoring and controlling following devices can be extended easily. Basic signals for CHP unit control (external emergency stop, external start, etc) can be connected to the customer s terminal box. Units are functionally tested for operation in production plant. TEDOM CHP units are continuously innovated from the knowledge of previous projects. By decision of Notified Body 1015*, certificate E-30-01048-10 was issued, to confirm the compliance of the Cento series with the requirements of Directive 2009/142/EC (Government Regulation No. 22/2003 Coll.). TEDOM is also the holder of QMS and EMS Quality Management Certificates. In terms of tests performed on the control switchboard, the Electrotechnical Testing Institute (Certification Body No. 3018, accredited by Czech Accreditation Institute) granted certificate according to ČSN EN 45011. Amongst others, the product is also certified for Russia, Ukraine and White Russia. * Machinery Testing Institute, Brno, Czech Republic. Design Operation Fuel Basic Technical Data Nominal electric output 200 kw Maximum heat output 237 kw Load 50 75 100 % Heat output 142 193 237 kw Fuel input 282 400 510 kw Electrical efficiency 35.3 37.5 39.2 % Heat efficiency 50.4 48.1 46.4 % Total efficiency (fuel use) 85.7 85.6 85.6 % Fuel consumption 29.9 42.4 54.0 m 3 /h Basic technical data above is valid for standard conditions according to the Guarantee Conditions document. The minimum permanent electric output is 50% of nominal output. Gas consumption is expressed under standard conditions (15 C, 101,325 kpa). Emissions Emissions At 5% O 2 in exhaust gas CO NOx 650 mg/nm 3 500 mg/nm 3 With oxidative catalyst 300 mg/nm 3 500 mg/nm 3 Generator Source of electric energy is synchronous generator with basic parameters according to the following table: Cos 1.0 Efficiency in working point 95.7 % Voltage Frequency Containerised SP - synchronous, parallel with mains Natural gas 400 V 50 Hz TS_Cento T200_ZP_KON_F07 2

Engine CHP unit is driven by gas combustion engine TG 210 G5V TW 86, product of TEDOM. Number of cylinders 6 Arrangement of cylinders Bore stroke In Series 130 150 mm Displacement 11946 cm 3 Compression ratio 12 : 1 Speed Oil consumption normal / maximum Maximum output of engine TG 210 G5V TW 86_850; Revision E: 10.1.2013 Thermal System Illustrative Picture 1500 rpm 0.3 / 0.5 g/kwh 212.7 kw In terms of heat output extraction, the CHP unit s heat output is generated by the secondary circuit. The technological circuit s output is wasted in the cooling unit. Primary Circuit: This is the internal closed pressure circuit, which takes heat from engine water jacket and exhaust gases and passes it into the secondary circuit. If this circuit s thermal output cannot be removed in marginal modes of operation, this output or its part can be removed by cooling unit for emergency cooling, which can be also supplied. Heat output of circuit Maximum working pressure 237 kw 250 kpa Water volume in CHP unit circuit 280 dm 3 Technological Circuit: This is the filling mixture cooling circuit. The utilization level of the heat output from this circuit and its cooling both influence the attainment of basic technical data values. The technological circuit s heat output can be used in lowtemperature circuits (water-pre-heating, heating of water in swimming pools or other technologies). If it is not possible to use the heat, and the permanent nominal electrical output is required, it must be wasted in the outer cooling unit (water-air exchanger), which can be also supplied. The heating water to charge the hydraulic circuits must be treated, its composition must correspond to the Guarantee Conditions document. Heat carrier Water + Ethylene-glycol Ethylene glycol concentration 35 % Heat output of circuit Nominal coolant temperature at the inlet Nominal flow rate Maximum working pressure 16 kw 35 C 90 l/min 300 kpa Water volume in CHP unit circuit 50 dm 3 Secondary Circuit: This circuit is used to deliver the main heat output of the CHP unit to the heating system. Observance of the maximum permissible return water temperature is essential for troublefree operation of the unit. Parts of the secondary circuit located outdoors (interconnecting pipe) must be protected against freezing (insulation, temperature treatment etc). The circuit is not equipped with circulating pump. Heat carrier Heat output of circuit Water 237 kw Nominal water temperature inlet / outlet 70 / 90 C Temperature of return water min / max 40 / 70 C Nominal flow rate 174 l/min Maximum working pressure 600 kpa Water volume in CHP unit circuit 30 dm 3 Pressure loss at nominal flow rate 30 kpa Nominal temperature drop 20 C TS_Cento T200_ZP_KON_F07 3

Fuel, Gas Inlet Technical data mentioned in this specification is valid for natural gas with parameters given below: Heat value 34 MJ/m 3 Minimum methane number 80 Gas pressure Maximum pressure change under varying consumption 5-10 kpa 10 % Maximum gas temperature 30 C CHP units can be operated on natural gas, biogas, propane, landfill gas (the fuels can be further modified as agreed with the technical design department). The limit parameters of biogas and other fuels that limit their fitness for use are given in the Guarantee Conditions document. The CHP unit s gas route is constructed in conformity to TPG 811 01 and contains a set of two independent quick-closing electromagnetic valves to shut off the gas inlet when the CHP unit is turned off, gas pressure zero regulator and metal hose for connection to mixer. Gas filter is installed for biogas applications. Gas connection of suitable size with adequate accumulation volume is required for the correct operation of CHP unit, to avoid gas pressure decrease in distribution system at the moment of incremental gas off-take. This gas connection will be terminated by manual gas stop and fitted with a pressure gauge. Combustion & Ventilation Air The unusable heat (radiated from hot parts of the CHP unit) is removed from the container by forced air ventilation, which enters the unit by the fan in the inlet port on the container roof. Ventilation air leaves the container through the ceiling port in the opposite area. Both Inlet and outlet openings of the ventilation system are fitted with rain protection canopies and the air-conditioning flap with servo-drive. Part of the air inside the container is separated from ventilation air and used as combustion air. Electric heating elements are installed for temperature treatment of the container interior. These elements will allow temperature treatment during CHP unit shut-down in the heating season, to ensure the temperature inside the container doesn t fall below the minimum necessary to start the enginegenerator. Unusable heat removed by ventilation air 25 kw Quantity of combustion air 846 Nm 3 /h Quantity of ventilation air 7700 Nm 3 /h Outdoor air temperature min / max -20 / 35 C Exhaust Gas & Condensate Outlet Combustion products exit from the CHP unit through the outlet exhaust conduit connected to exhaust silencer s outlet flange. Exhaust silencer is placed on the container roof. Exhaust gases can be removed as required into suitable stack through an exhaust conduit, or can leave directly into atmosphere. The linked exhaust conduit (if used) must be inclined offward the CHP unit. Exhaust gas quantity 890 Nm 3 /h Exhaust gas temperature nominal / maximum Maximum back-pressure behind CHP unit flange Exhaust gas speed at outlet (DN 150) Lubricants 120 / 150 C 10 mbar 20.1 m/s Quantity of lubricating oil in engine 56 dm 3 Volume of replenishment oil tank 125 dm 3 Noise Parameters Noise parameters indicate the acoustic pressure level measured in free field conditions. Determination of measuring point and method of evaluation comply with ČSN 09 0862 and ČSN EN ISO 3746. CHP unit 10m from sound enclosure (1) 75 db(a) (1) Noise related to engine-generator set and cooling units in operation. (2) The noise may contain a tone component with a frequency of 75 Hz. Electrical Parameters Nominal voltage Nominal frequency 230 / 400 V 50 Hz Power factor 0.8L - 0.8C Nominal current at cos φ=0.8 Generator circuit breaker Short-circuit resistance of switchboard Contribution of the actual source to shortcircuit current Power switchboard protection closed / opened Control switchboard protection closed / opened Recommended superior circuit breaker Recommended connection cable** (length <50m, at temperature <35 C) 360 A NSX400F 3P 25 ka < 4.0 ka IP 31/00 IP 31/00 400 A NYY-J 3 240+120 ** The stated cables are for information only. A check calculation for temperature rise and voltage drop must be made according to the actual length, placement and type of cable (maximum allowed voltage drop is 10 V). TS_Cento T200_ZP_KON_F07 4

Switchboard Design The electrical part of the CHP unit is located in sheet-steel switchboard that includes both the power and control parts. Power Switchboard Contains: Generator circuit breaker, which protects generator and part of power line against over-current and short circuit. Generator contactor that is used as a switching component for synchronizing generator to mains. XV terminal for connecting the power cable. XG terminal for connecting the generator. Current measuring transformers. Control Switchboard Contains: Central part of the control system, and any extension modules. Protecting and switching components. Controlling components for maintenance purposes. 24VDC power supply. Terminals for connecting analogue sensors, binary switches, controlled devices, remote communication etc. Customer terminal box. Control System Control of the CHP unit is enabled by ProCon Sight control system, which allows fully automated operation. It is a multiprocessor modular system, consisting of the control unit, display unit and extension modules with analogue and binary inputs and outputs. Due to colour display with high resolution, plus the context and navigation buttons, the display unit provides easy access to all data about gen-set, monitored values, and time trends of these values. ProCon Sight display unit can communication in up to seven languages, one of which can be graphical (e.g. Chinese, Korean). Main Features of Display Unit: Large 8 colour TFT display with 800 600 pixel resolution. Easier and faster operation by using the context buttons. Permanently displayed status bar. Time history display of selected values - graphs. Clearer history display. Windows CE operating system. Measured Values The control system measures and evaluates following values: Electrical Values: 3 generator voltage 3 generator current 3 mains voltage Listed Electrical Values Are Used For: Evaluation of the mains parameters. Automatic synchronization of generator to mains. Calculations and evaluation of required electrical values. Technological Values: CHP unit is equipped with set of binary and analogue sensors that monitor all the necessary processes to optimize them. Optimization is performed by the relevant outputs in control of relevant applications. Operation Methods Local: By buttons located on the display unit. Remote (on request): By voltage-free contacts (external timer, superior control system etc.) According to the required power level or building consumption level. From local or remote PC. Via SMS messaging. Building Consumption Control (on request): The system obtains information on the building consumption from the converter which measures direction and size of the demand/supply from/to the mains. Required Power Control (on request): By analogue signal - e.g. 0/4-20mA Via data path - e.g. MODBUS-RTU protocol. TS_Cento T200_ZP_KON_F07 5

Gen-set Operation Monitoring From Local PC - Connection Possibilities: RS232 RS485 USB Amendments Due to our policy of continual improvement, we reserve the privilege to change this document and consequential documents without notice. From Remote PC - Connection Possibilities (on request): Analogue modem GSM modem Internet Via SMS Messaging (on request) Colour Design Engine, generator and internal parts of unit Container RAL 5015 (Blue) RAL 5013 (Blue) Dimensions & Weight Information Dimensions vary depending on optional extras included. Please see GA drawing for full details. Length Total / Transport Width Total / Transport Height Total / Transport Transport weight of CHP unit Transport weight of other parts Operational weight of entire CHP unit 5550 / 5000 mm 3000 / 2500 mm 6000 / 2700 mm 7540 Kg 1200 Kg 9285 Kg Additional Documents Dimensional drawing of CHP: Cento T160-T200 Containerised GA Drawing_ R1261. P&ID: Cento T160-T200 Containerised P&ID_S0489A. Generally binding source materials according to the Guarantee Conditions document. Delivery Range Standard: Complete CHP unit in container. Separate exhaust silencer. Out of Standard Range: Cooling unit for primary circuit emergency cooling. Oxidative catalyzer. Additional exhaust silencer. Condensate drain. Firestop automatic extinguishing system. Additional electrical refitting as required by customer - see Operation Methods section. TS_Cento T200_ZP_KON_F07 6